Ravil A. Usmanov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ravil A. Usmanov has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
V. P. Smirnov
Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow, Russia
11 shared publications- Gennadii Dmitrievich Liziakin
Physics Department, Technion-Israeli Institute of Technology , Haifa 3200003
10 shared publications - Andrey Gavrikov
Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow, Russia
9 shared publications - A. D. Melnikov
Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow, Russia
8 shared publications A. V. Gavrikov
JIHT RAS, Moscow, Russian Federation
8 shared publicationsV P Smirnov
Laboratory of Electrophysical and Plasma Devices, Joint Institute for High Temperature, Moscow 125412, Russia
7 shared publications
Latest Publications
- 10 November 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 140 (18)
Vacuum arc on a heated chromium cathode: Cathode spot dynamics and conditions for diffuse mode
Diffuse vacuum arc application requires the cathode conditions for stable operation in the diffuse mode to be determined. In this work, such conditions are established for a heated chromium cathode. At a discharge current of 30–40 A, the diffuse mode is sustained within a limited range of cathode temperatures of 1.8–2.0 kK. Outside this range, the discharge becomes non-stationary. Statistical analysis of cathode spot motion in these non-stationary modes reveals random displacements in the presence of an axial magnetic field of 10 mT. The diffusion coefficient of cathode spot motion is determined to be 0.7–3.3 cm2/s, which is consistent with values reported for vacuum arcs on cold cathodes.
- 10 November 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 140 (18)
Vacuum arc on a heated chromium cathode: Cathode spot dynamics and conditions for diffuse mode
Diffuse vacuum arc application requires the cathode conditions for stable operation in the diffuse mode to be determined. In this work, such conditions are established for a heated chromium cathode. At a discharge current of 30–40 A, the diffuse mode is sustained within a limited range of cathode temperatures of 1.8–2.0 kK. Outside this range, the discharge becomes non-stationary. Statistical analysis of cathode spot motion in these non-stationary modes reveals random displacements in the presence of an axial magnetic field of 10 mT. The diffusion coefficient of cathode spot motion is determined to be 0.7–3.3 cm2/s, which is consistent with values reported for vacuum arcs on cold cathodes.
- 14 September 2026
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 90 (9) , 1567-1573
Effect of External Axial Magnetic Field on Current–Voltage Characteristics of Diffuse Vacuum Arc
Diffuse vacuum arc is currently being investigated as a promising plasma source for the plasma separation method of spent nuclear fuel. In this work, current–voltage characteristics (CVC) of diffuse vacuum arcs with thermionic (Gd) and non-thermionic (Cr) cathodes in an external axial magnetic field were investigated. It was found that discharge with a Cr cathode demonstrates a linear CVC with a negative slope. For a thermionic Gd, non-monotonic CVCs were obtained. Moreover, in the set range of parameters (discharge current from 10 to 60 A, cathode temperature 1970 K, external magnetic field 20 mT), two types of CVCs with different voltages were found for the Gd cathode: non-monotonic and with a negative slope. This fact may indicate that various forms of diffuse vacuum arc may exist in the set parameter range. For the non-thermionic chrome, CVC stays linear and shows little dependence on the magnetic field. For the thermionic gadolinium, the effect of the magnetic field is more significant: differential resistance of positive-slope branches of the CVC increases by an order of magnitude with an increase in magnetic field from 0 to 30 mT. The latter fact may indicate the difference in current-transfer mechanisms for discharges with thermionic and non-thermionic cathodes.
- 14 September 2026
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 90 (9) , 1567-1573
Effect of External Axial Magnetic Field on Current–Voltage Characteristics of Diffuse Vacuum Arc
Diffuse vacuum arc is currently being investigated as a promising plasma source for the plasma separation method of spent nuclear fuel. In this work, current–voltage characteristics (CVC) of diffuse vacuum arcs with thermionic (Gd) and non-thermionic (Cr) cathodes in an external axial magnetic field were investigated. It was found that discharge with a Cr cathode demonstrates a linear CVC with a negative slope. For a thermionic Gd, non-monotonic CVCs were obtained. Moreover, in the set range of parameters (discharge current from 10 to 60 A, cathode temperature 1970 K, external magnetic field 20 mT), two types of CVCs with different voltages were found for the Gd cathode: non-monotonic and with a negative slope. This fact may indicate that various forms of diffuse vacuum arc may exist in the set parameter range. For the non-thermionic chrome, CVC stays linear and shows little dependence on the magnetic field. For the thermionic gadolinium, the effect of the magnetic field is more significant: differential resistance of positive-slope branches of the CVC increases by an order of magnitude with an increase in magnetic field from 0 to 30 mT. The latter fact may indicate the difference in current-transfer mechanisms for discharges with thermionic and non-thermionic cathodes.
- 14 September 2026
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 90 (9) , 1635-1641
Diagnostics of the Plasma Mass Separation Process in Configuration with Potential Well
A comprehensive diagnostics system for monitoring plasma mass separation process is described. With the help of the system the mass separation effect of a binary silver-lead mixture, simulating spent nuclear fuel components, in a crossed E × B field configuration with a potential well is successfully demonstrated. The mass separation effect was verified by three independent diagnostic methods: spatial distribution of silver and lead deposited on the collector, ion current analysis, and deposited mass measurement. The results hold significant promise for application in nuclear energy sector as a novel stage in spent nuclear fuel reprocessing.
- 14 September 2026
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 90 (9) , 1635-1641
Diagnostics of the Plasma Mass Separation Process in Configuration with Potential Well
A comprehensive diagnostics system for monitoring plasma mass separation process is described. With the help of the system the mass separation effect of a binary silver-lead mixture, simulating spent nuclear fuel components, in a crossed E × B field configuration with a potential well is successfully demonstrated. The mass separation effect was verified by three independent diagnostic methods: spatial distribution of silver and lead deposited on the collector, ion current analysis, and deposited mass measurement. The results hold significant promise for application in nuclear energy sector as a novel stage in spent nuclear fuel reprocessing.
- Open Access
- 1 March 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (3)
Experimental study of plasma potential in an asymmetric reflex discharge with thermionic cathode
This study presents an experimental methodology for generating an asymmetric distribution of plasma potential in a reflex discharge system with a thermionic cathode. Radial profiles of the plasma potential were measured using a thermionic probe under varying magnetic field strengths and gas pressures. The asymmetrization resulted in a nearly twofold increase in peak electric field intensity. A system of floating probes was employed to investigate perturbations and plasma instabilities arising in this configuration. Spectral analysis revealed two distinct oscillation frequencies, indicating the occurrence of a drift-type perturbation.
- 1 March 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (3)
Open AccessExperimental study of plasma potential in an asymmetric reflex discharge with thermionic cathode
This study presents an experimental methodology for generating an asymmetric distribution of plasma potential in a reflex discharge system with a thermionic cathode. Radial profiles of the plasma potential were measured using a thermionic probe under varying magnetic field strengths and gas pressures. The asymmetrization resulted in a nearly twofold increase in peak electric field intensity. A system of floating probes was employed to investigate perturbations and plasma instabilities arising in this configuration. Spectral analysis revealed two distinct oscillation frequencies, indicating the occurrence of a drift-type perturbation.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (3) , 1117-1125
Diffuse Vacuum Arc on Lead Cathode: Plasma Parameters and Mechanism of the Charge Transfer on the Nonthermionic Cathodes
This article presents a study of an arc discharge with a diffuse current attachment on a cathode made of lead. The arc current was in the range of 10–27 A, and an average current density on the cathode was about 10 A/cm2. The saturated vapor pressure of lead at the operating cathode temperature of ~1.4 kK is ~1 kPa, and the thermionic current density is $\sim\!\!1~\mu $ A/cm2. The spatial distributions of electric potential and the excitation temperature of atomic states were measured in the discharge gap. The existence of a negative anode potential drop was demonstrated. The ion energy and mean charge of heavy plasma particles were measured in the region behind the anode. A qualitative model of the cathode layer was considered, and its parameters were estimated. The hypothesis about the ion mechanism of charge transfer on the surface of the lead cathode was confirmed.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (3) , 1117-1125
Diffuse Vacuum Arc on Lead Cathode: Plasma Parameters and Mechanism of the Charge Transfer on the Nonthermionic Cathodes
This article presents a study of an arc discharge with a diffuse current attachment on a cathode made of lead. The arc current was in the range of 10–27 A, and an average current density on the cathode was about 10 A/cm2. The saturated vapor pressure of lead at the operating cathode temperature of ~1.4 kK is ~1 kPa, and the thermionic current density is $\sim\!\!1~\mu $ A/cm2. The spatial distributions of electric potential and the excitation temperature of atomic states were measured in the discharge gap. The existence of a negative anode potential drop was demonstrated. The ion energy and mean charge of heavy plasma particles were measured in the region behind the anode. A qualitative model of the cathode layer was considered, and its parameters were estimated. The hypothesis about the ion mechanism of charge transfer on the surface of the lead cathode was confirmed.
- 1 December 2025
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 89 (S2) , S218-S224
Transient Processes during the Initiation and Stabilization of a Diffuse Vacuum Arc Discharge on a Gadolinium Cathode
The processes on the cathode surface prior to the establishment of a diffuse mode of vacuum arc discharge on gadolinium cathode was investigated. Using high-speed video recordings and voltage waveforms, the breakdown process and the ejection of cathode material droplets were examined. The temporal dependences of cathode temperature and discharge voltage after breakdown were analyzed. Characteristic times for the transition to the steady-state diffuse discharge mode were determined. It was found that during breakdown and after, when discharge is unstable, droplets and voltage spikes can occur. Discharge stabilization can be achieved by increasing the cathode temperature, which leads to the transition to a mode with a voltage of about 5 V and the absence of voltage spikes and droplets. These results are significant for the development of a plasma source for the plasma separation of spent nuclear fuel.
- 1 December 2025
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 89 (S2) , S218-S224
Transient Processes during the Initiation and Stabilization of a Diffuse Vacuum Arc Discharge on a Gadolinium Cathode
The processes on the cathode surface prior to the establishment of a diffuse mode of vacuum arc discharge on gadolinium cathode was investigated. Using high-speed video recordings and voltage waveforms, the breakdown process and the ejection of cathode material droplets were examined. The temporal dependences of cathode temperature and discharge voltage after breakdown were analyzed. Characteristic times for the transition to the steady-state diffuse discharge mode were determined. It was found that during breakdown and after, when discharge is unstable, droplets and voltage spikes can occur. Discharge stabilization can be achieved by increasing the cathode temperature, which leads to the transition to a mode with a voltage of about 5 V and the absence of voltage spikes and droplets. These results are significant for the development of a plasma source for the plasma separation of spent nuclear fuel.
- 1 May 2025
- Published by Springer Nature in Atomic Energy
- Vol. 138 (1-2) , 54-60
Development and demonstration of basics for plasma reprocessing of spent nuclear fuel
- 1 May 2025
- Published by Springer Nature in Atomic Energy
- Vol. 138 (1-2) , 54-60
Development and demonstration of basics for plasma reprocessing of spent nuclear fuel
- 9 October 2024
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 45 (1) , 21-32
Influence of Mixed Cathode Emissivity on Generated Plasma Flow in Vacuum Arc with Heated Cathode
- 9 October 2024
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 45 (1) , 21-32
Influence of Mixed Cathode Emissivity on Generated Plasma Flow in Vacuum Arc with Heated Cathode
- 13 August 2024
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 60 (10) , 1677-1685
Enhanced CeO2 evaporation from refractory crucibles (Mo, Ta, W)
- 13 August 2024
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 60 (10) , 1677-1685
Enhanced CeO2 evaporation from refractory crucibles (Mo, Ta, W)
- 20 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (4) , 1101-1106
Parameters of the Ion Flux Generated in a Vacuum Arc With a Dielectric Cathode in the First Minutes After Breakdown
Stability is one of the key directions of optimization for plasma sources. This article deals with the parameters of the plasma flux generated in a vacuum arc with a dielectric cathode made of CeO $_{2}$ in the period after a breakdown when the cathode relaxes after the impact caused by the initiation of plasma. The dielectric nature of the cathode made the period of relaxation rather long. It was shown that the plasma flux during the relaxation of the cathode was characterized by intense oscillations of ion energies and differed in the ionic composition from stable arcing. Cerium ions Ce $^{++}$ represented about 30% of the generated flux in the first minutes of the arc operation. An interpretation is presented of the anomalies observed.
- 20 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (4) , 1101-1106
Parameters of the Ion Flux Generated in a Vacuum Arc With a Dielectric Cathode in the First Minutes After Breakdown
Stability is one of the key directions of optimization for plasma sources. This article deals with the parameters of the plasma flux generated in a vacuum arc with a dielectric cathode made of CeO $_{2}$ in the period after a breakdown when the cathode relaxes after the impact caused by the initiation of plasma. The dielectric nature of the cathode made the period of relaxation rather long. It was shown that the plasma flux during the relaxation of the cathode was characterized by intense oscillations of ion energies and differed in the ionic composition from stable arcing. Cerium ions Ce $^{++}$ represented about 30% of the generated flux in the first minutes of the arc operation. An interpretation is presented of the anomalies observed.