MCMatteo Cencini

Matteo Cencini

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Matteo Cencini has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Linking dielectric dispersion and age in brain tissues via water content-based Electric Properties Tomography

    by Sébastien Marmin, Alessandro Arduino, Matteo Cencini, Marta Lancione, Laura Biagi, Michela Tosetti, Luca Zilberti


  • Open Access

    Repeatability and reproducibility of joint T1-T2 transient-state relaxometry across multiple vendors and implementations at 3T in phantom and human brain

    by Marta Lancione, Matteo Cencini, Domenico Aquino, Cristina Baldoli, Maurizio Elia, Francesco Ghielmetti, Domenico Montanaro, Ilaria Neri, Anna Nigri, Rosa Pasquariello, et al.


  • Open Access

    Detection of pathological contrast enhancement with synthetic brain imaging from quantitative multiparametric MRI

    by Graziella Donatelli, Gianmichele Migaleddu, Matteo Cencini, Paolo Cecchi, Claudio D'AMelio, Luca Peretti, Guido Buonincontri, Michela Tosetti, Mauro Costagli, Mirco Cosottini

    Background and Purpose: We aimed to test whether synthetic T1‐weighted imaging derived from a post‐contrast Quantitative Transient‐state Imaging (QTI) acquisition enabled revealing pathological contrast enhancement in intracranial lesions.Methods: The analysis included 141 patients who underwent a 3 Tesla‐MRI brain exam with intravenous contrast media administration, with the post‐contrast acquisition protocol comprising a three‐dimensional fast spoiled gradient echo (FSPGR) sequence and a QTI acquisition. Synthetic T1‐weighted images were generated from QTI‐derived quantitative maps of relaxation times and proton density. Two neuroradiologists assessed synthetic and conventional post‐contrast T1‐weighted images for the presence and pattern of pathological contrast enhancement in intracranial lesions. Enhancement volumes were quantitatively compared.Results: Using conventional imaging as a reference, synthetic T1‐weighted imaging was 93% sensitive in revealing the presence of contrast enhancing lesions. The agreement for the presence/absence of contrast enhancement was almost perfect both between readers (k = 1 for both conventional and synthetic imaging) and between sequences (k = 0.98 for both readers). In 91% of lesions, synthetic T1‐weighted imaging showed the same pattern of contrast enhancement visible in conventional imaging. Differences in enhancement pattern in the remaining lesions can be due to the lower spatial resolution and the longer acquisition delay from contrast media administration of QTI compared to FSPGR. Overall, enhancement volumes appeared larger in synthetic imaging.Conclusions: QTI‐derived post‐contrast synthetic T1‐weighted imaging captures pathological contrast enhancement in most intracranial enhancing lesions. Further comparative studies employing quantitative imaging with higher spatial resolution is needed to support our data and explore possible future applications in clinical trials.


  • Open Access

    Magnetic resonance fingerprinting‐based myelin water fraction mapping for the assessment of white matter maturation and integrity in typical development and leukodystrophies

    by Marta Lancione, Matteo Cencini, Elena Scaffei, Emilio Cipriano, Guido Buonincontri, Rolf F. Schulte, Carolin M. Pirkl, Bianca Buchignani, Rosa Pasquariello, Raffaello Canapicchi, et al.

    A quantitative biomarker for myelination, such as myelin water fraction (MWF), would boost the understanding of normative and pathological neurodevelopment, improving patients' diagnosis and follow‐up. We quantified the fraction of a rapidly relaxing pool identified as MW using multicomponent three‐dimensional (3D) magnetic resonance fingerprinting (MRF) to evaluate white matter (WM) maturation in typically developing (TD) children and alterations in leukodystrophies (LDs). We acquired DTI and 3D MRF‐based R1, R2 and MWF data of 15 TD children and 17 LD patients (9 months–12.5 years old) at 1.5 T. We computed normative maturation curves in corpus callosum and corona radiata and performed WM tract profile analysis, comparing MWF with R1, R2 and fractional anisotropy (FA). Normative maturation curves demonstrated a steep increase for all tissue parameters in the first 3 years of age, followed by slower growth for MWF while R1, R2R2 and FA reached a plateau. Unlike FA, MWF values were similar for regions of interest (ROIs) with different degrees of axonal packing, suggesting independence from fiber bundle macro‐organization and higher myelin specificity. Tract profile analysis indicated a specific spatial pattern of myelination in the major fiber bundles, consistent across subjects. LD were better distinguished from TD by MWF rather than FA, showing reduced MWF with respect to age‐matched controls in both ROI‐based and tract analysis. In conclusion, MRF‐based MWF provides myelin‐specific WM maturation curves and is sensitive to alteration due to LDs, suggesting its potential as a biomarker for WM disorders. As MRF allows fast simultaneous acquisition of relaxometry and MWF, it can represent a valuable diagnostic tool to study and follow up developmental WM disorders in children.


  • Open Access

    Generating Synthetic Radiological Images with PySynthMRI: An Open-Source Cross-Platform Tool

    by Luca Peretti, Graziella Donatelli, Matteo Cencini, Paolo Cecchi, Guido Buonincontri, Mirco Cosottini, Michela Tosetti, Mauro Costagli

    Synthetic MR Imaging allows for the reconstruction of different image contrasts from a single acquisition, reducing scan times. Commercial products that implement synthetic MRI are used in research. They rely on vendor-specific acquisitions and do not include the possibility of using custom multiparametric imaging techniques. We introduce PySynthMRI, an open-source tool with a user-friendly interface that uses a set of input images to generate synthetic images with diverse radiological contrasts by varying representative parameters of the desired target sequence, including the echo time, repetition time and inversion time(s). PySynthMRI is written in Python 3.6, and it can be executed under Linux, Windows, or MacOS as a python script or an executable. The tool is free and open source and is developed while taking into consideration the possibility of software customization by the end user. PySynthMRI generates synthetic images by calculating the pixelwise signal intensity as a function of a set of input images (e.g., T1 and T2 maps) and simulated scanner parameters chosen by the user via a graphical interface. The distribution provides a set of default synthetic contrasts, including T1w gradient echo, T2w spin echo, FLAIR and Double Inversion Recovery. The synthetic images can be exported in DICOM or NiFTI format. PySynthMRI allows for the fast synthetization of differently weighted MR images based on quantitative maps. Specialists can use the provided signal models to retrospectively generate contrasts and add custom ones. The modular architecture of the tool can be exploited to add new features without impacting the codebase.


  • Open Access

    Learning residual motion correction for fast and robust 3D multiparametric MRI

    by Carolin M. Pirkl, Matteo Cencini, Jan W. Kurzawski, Diana Waldmannstetter, Hongwei Li, Anjany Sekuboyina, Sebastian Endt, Luca Peretti, Graziella Donatelli, Rosa Pasquariello, et al.


  • Pattern-Matching Unit for Medical Applications

    by Orlando Leombruni, Alberto Annovi, Paola Giannetti, Nicolo Vladi Biesuz, Chiara Roda, Milene Calvetti, Marco Piendibene, Luca Peretti, Matteo Cencini, Michela Tosetti, et al.

    We explore the application of concepts developed in High Energy Physics (HEP) in a field of high social impact, i.e. advanced medical data analysis. More specifically, we focus on shortening the reconstruction times of a multi-parametric quantitative Magnetic Resonance Imaging (MRI) technique: Magnetic Resonance Fingerprinting (MRF). This technique has the potential to replace multiple qualitative MRI acquisitions with a single reproducible measurement for increased sensitivity and efficiency of the examination. In MRF, a fast acquisition is followed by a pattern matching (PM) task, where signal responses are matched to entries from a dictionary of simulated, physically-feasible responses, yielding multiple tissue parameters simultaneously. Each voxel signal response in the volume is compared through scalar products with all dictionary entries to choose the best measurement reproduction. MRF is limited by the PM processing time, which scales exponentially with the dictionary dimensionality, i.e. with the number of tissue parameters to be reconstructed. In the context of HEP, we developed a powerful, compact, embedded system, optimized for extremely fast PM. This system executes real-time particle trajectory (track) reconstruction for online event selection in the HEP experiments, exploiting maximum parallelism and pipelining. Track reconstruction is executed in two steps. The Associative Memory (AM) ASIC first implements a PM algorithm by recognizing track candidates at low resolution. The second step, which is implemented into FPGAs (Field Programmable Gate Arrays), refines the AM output finding the track parameters at full resolution. We propose to use this system to achieve a faster reconstruction time in MRF. This paper proposes an adaptation of the HEP system for medical imaging and shows some preliminary results


  • Open Access

    Pattern-matching Unit for Medical Applications

    by O. Leombruni, A. Annovi, P. Giannetti, N. V. Biesuz, C. Roda, M. Piendibene, M. Calvetti, L. Peretti, M. Cencini, M. Tosetti, et al.

    We explore the application of concepts developed in High Energy Physics (HEP) for advanced medical data analysis. Our study case is a problem with high social impact: clinically-feasible Magnetic Resonance Fingerprinting (MRF). MRF is a new, quantitative, imaging technique that replaces multiple qualitative Magnetic Resonance Imaging (MRI) exams with a single, reproducible measurement for increased sensitivity and efficiency. A fast acquisition is followed by a pattern matching (PM) task, where signal responses are matched to entries from a dictionary of simulated, physically-feasible responses, yielding multiple tissue parameters simultaneously. Each pixel signal response in the volume is compared through scalar products with all dictionary entries to choose the best measurement reproduction. MRF is limited by the PM processing time, which scales exponentially with the dictionary dimensionality, i.e. with the number of tissue parameters to be reconstructed. We developed for HEP a powerful, compact, embedded system, optimized for extremely fast PM. This system executes real-time tracking for online event selection in the HEP experiments, exploiting maximum parallelism and pipelining. Track reconstruction is executed in two steps. The Associative Memory (AM) ASIC first implements a PM algorithm by recognizing track candidates at low resolution. The second step, which is implemented into FPGAs (Field Programmable Gate Arrays), refines the AM output finding the track parameters at full resolution. We propose to use this system to perform MRF, to achieve clinically reasonable reconstruction time. This paper proposes an adaptation of the HEP system for medical imaging and shows some preliminary results.

  • Retrospective rigid motion correction of three‐dimensional magnetic resonance fingerprinting of the human brain

    by Jan W. Kurzawski, Matteo Cencini, Luca Peretti, Pedro A. Gómez, Rolf F. Schulte, Graziella Donatelli, Mirco Cosottini, Paolo Cecchi, Mauro Costagli, Alessandra Retico, et al.

    Purpose: To obtain three‐dimensional (3D), quantitative and motion‐robust imaging with magnetic resonance fingerprinting (MRF).Methods: Our acquisition is based on a 3D spiral projection k‐space scheme. We compared different orderings of trajectory interleaves in terms of rigid motion‐correction robustness. In all tested orderings, we considered the whole dataset as a sum of 56 segments of 7‐s duration, acquired sequentially with the same flip angle schedule. We performed a separate image reconstruction for each segment, producing whole‐brain navigators that were aligned to the first segment using normalized correlation. The estimated rigid motion was used to correct the k‐space data, and the aligned data were matched with the dictionary to obtain motion‐corrected maps.Results: A significant improvement on the motion‐affected maps after motion correction is evident with the suppression of motion artifacts. Correlation with the motionless baseline improved by 20% on average for both T1 and T2 estimations after motion correction. In addition, the average motion‐induced quantification bias of 70 ms for T1 and 18 ms for T2 values was reduced to 12 ms and 6 ms, respectively, improving the reliability of quantitative estimations.Conclusion: We established a method that allows correcting 3D rigid motion on a 7‐s timescale during the reconstruction of MRF data using self‐navigators, improving the image quality and the quantification robustness.


  • An Aristotelian View on MR-Based Attenuation Correction (ARISTOMRAC): Combining the Four Elements

    by Matteo Cencini, Michela Tosetti, Guido Buonincontri

    MR-based attenuation correction (MRAC) is important for accurate quantification of the uptake of PET tracers in combined PET/MR scanners. However, current techniques for MRAC usually require multiple acquisitions or complex post-processing to discriminate the different tissues. Inspired by the ancient Greeks, who believed that matter was made of the combination of four elements (earth, water, air and fire), we formulated a multi-component Magnetic Resonance (MR) Fingerprinting framework, where every voxel was considered a weighted combination of four base elements: bone, water, air and fat. We named our approach Aristotelian MR based attenuation correction (ARISTOMRAC). We used a 3D radial acquisition scheme at 1.5T, acquiring a transient-state spoiled acquisition with variable flip angles and echo times (TE), with the shortest TEs being ultra-short echo times (UTE). We simulated a multi-tissue MR signal model using the Bloch equations and used dictionary matching to extract tissue fraction maps for bone water and fat, while air fractions were obtained by thresholding the UTE parts of our acquisitions at higher spatial resolution. Compared to previous methods for MR-based Attenuation Correction (MRAC), our approach used a full multi-component signal model, including multiple tissues per voxel. For this reason, rather than reconstructing high resolutions images, MR data can be acquired more efficiently, directly at the resolution needed for PET attenuation maps. The ARISTOMRAC method allows to accurately estimate the air, water, bone and fat fractions (Concordance Correlation Coefficient = 0.81/0.91/0.98 for bone, water and fat respectively). Attenuation maps could be obtained in the head and neck with a single 1-minute acquisition.