Oleg Orlov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oleg Orlov has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Alexey Sidorin
Dzhelepov Laboratory of Nuclear Problems, Joint Institute for Nuclear Research, Dubna 141980, Russia
3 shared publications - Anton Lomygin
National Research Tomsk Polytechnic University, Tomsk, Russia
3 shared publications - Dmitriy Krotkevich
Division for Experimental Physics, National Research Tomsk Polytechnic University, 634050 Tomsk, Russia
3 shared publications - Ekaterina N. Stepanova
Division for Experimental Physics, National Research Tomsk Polytechnic University, Tomsk 634050, Russia
3 shared publications - Igor' N. Meshkov
Joint Institute for Nuclear Research, Dubna, Russia
3 shared publications - Marat Kanalbekovich Eseev
Northern (Arctic) Federal University, Arkhangelsk, Russia
3 shared publications
Latest Publications
- 3 July 2024
- Published by Elsevier in Solid State Ionics
- Vol. 414, 116640
Study defects formation mechanism in La1-Ba MnO3 perovskite manganite by positron annihilation lifetime and Doppler broadening spectroscopy
- 3 July 2024
- Published by Elsevier in Solid State Ionics
- Vol. 414, 116640
Study defects formation mechanism in La1-Ba MnO3 perovskite manganite by positron annihilation lifetime and Doppler broadening spectroscopy
- 17 April 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (3)
Effects of high-temperature annealing on vacancy complexes and luminescence properties in multilayer periodic structures with elastically strained GeSiSn layers
Effects of postgrowth high-temperature annealing on vacancy complexes and photoluminescence (PL) from GeSiSn/Si multiple quantum wells (MQWs) are studied. The series of PL peaks related to the vacancy-tin complexes was observed for as-grown samples including different structures, such as GeSiSn/Si MQWs, multilayer periodic structure with GeSiSn quantum dots (QDs), GeSn cross-structures upon GeSiSn/Si MQWs, and thick GeSiSn layers. The PL band intensity is significantly reduced after annealing at 700 °C corresponding to the reduction in vacancy density, as demonstrated by the positron annihilation spectroscopy (PAS) data. Such annealing also results in the appearance of the PL signal related to the interband optical transitions in GeSiSn/Si MQWs. However, the high temperature could negatively impact the sharpness of heterointerfaces due to Sn diffusion, thus limiting the PL efficiency. To improve the luminescence properties of GeSiSn/Si structures, we proposed a two-stage technique combining both the annealing and subsequent treatment of samples in a hydrogen plasma at 200 °C. The plasma treatment significantly reduces the PL band of vacancy-related defects, whereas annealing at a moderate temperature of ∼600 °C prevents the blurring of heterointerfaces. As a result, we demonstrate an increase in the relative efficiency of interband PL of type II GeSiSn/Si MQW structures emitting in the range of 1.5–2 μm.
- 17 April 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (3)
Effects of high-temperature annealing on vacancy complexes and luminescence properties in multilayer periodic structures with elastically strained GeSiSn layers
Effects of postgrowth high-temperature annealing on vacancy complexes and photoluminescence (PL) from GeSiSn/Si multiple quantum wells (MQWs) are studied. The series of PL peaks related to the vacancy-tin complexes was observed for as-grown samples including different structures, such as GeSiSn/Si MQWs, multilayer periodic structure with GeSiSn quantum dots (QDs), GeSn cross-structures upon GeSiSn/Si MQWs, and thick GeSiSn layers. The PL band intensity is significantly reduced after annealing at 700 °C corresponding to the reduction in vacancy density, as demonstrated by the positron annihilation spectroscopy (PAS) data. Such annealing also results in the appearance of the PL signal related to the interband optical transitions in GeSiSn/Si MQWs. However, the high temperature could negatively impact the sharpness of heterointerfaces due to Sn diffusion, thus limiting the PL efficiency. To improve the luminescence properties of GeSiSn/Si structures, we proposed a two-stage technique combining both the annealing and subsequent treatment of samples in a hydrogen plasma at 200 °C. The plasma treatment significantly reduces the PL band of vacancy-related defects, whereas annealing at a moderate temperature of ∼600 °C prevents the blurring of heterointerfaces. As a result, we demonstrate an increase in the relative efficiency of interband PL of type II GeSiSn/Si MQW structures emitting in the range of 1.5–2 μm.
- Open Access
Hydrogen-Induced Microstructure Changes in Zr/Nb Nanoscale Multilayer Structures
Zr/Nb nanoscale multilayer coatings (NMCs) were studied after hydrogenation in a gaseous environment at 400 °C. The hydrogen distribution and content were determined by pressure and hydrogenation time. Increasing the pressure from 0.2 to 2 MPa resulted in different hydrogen distribution within the Zr/Nb NMCs, while the concentration remained constant at 0.0150 ± 0.0015 wt. %. The hydrogen concentration increased from 0.0165 ± 0.001 to 0.0370 ± 0.0015 wt. % when the hydrogenation time was extended from 1 to 7 h. The δ-ZrH hydride phase was formed in the Zr layers with Zr crystals reorienting towards the [100] direction. The Nb(110) diffraction reflex shifted towards smaller angles and the interplanar distance in the niobium layers increased, indicating significant lateral compressive stresses. Despite an increase in pressure, the nanohardness and Young’s modulus of the Zr/Nb NMCs remained stable. Increasing the hydrogen concentration to 0.0370 ± 0.0015 wt. % resulted in a 40% increase in nanohardness. At this concentration, the relative values of the Doppler broadening variable energy positron annihilation spectroscopy (S/S0) increased above the initial level, indicating an increase in excess free volume due to hydrogen-induced defects and changes. However, the predominant positron capture center remained intact. The Zr/Nb NMCs with hydrogen content ranging from 0.0150 ± 0.0015 to 0.0180 ± 0.001 wt. % exhibited a decrease in the free volume probed by positrons, as demonstrated by the Doppler broadening variable energy positron annihilation spectroscopy. This was evidenced by opposite changes in S and W (S↓W↑). The microstructural changes are attributed to defect annihilation during hydrogen accumulation near interfaces with the formation of hydrogen–vacancy clusters and hydrides.
Open AccessHydrogen-Induced Microstructure Changes in Zr/Nb Nanoscale Multilayer Structures
Zr/Nb nanoscale multilayer coatings (NMCs) were studied after hydrogenation in a gaseous environment at 400 °C. The hydrogen distribution and content were determined by pressure and hydrogenation time. Increasing the pressure from 0.2 to 2 MPa resulted in different hydrogen distribution within the Zr/Nb NMCs, while the concentration remained constant at 0.0150 ± 0.0015 wt. %. The hydrogen concentration increased from 0.0165 ± 0.001 to 0.0370 ± 0.0015 wt. % when the hydrogenation time was extended from 1 to 7 h. The δ-ZrH hydride phase was formed in the Zr layers with Zr crystals reorienting towards the [100] direction. The Nb(110) diffraction reflex shifted towards smaller angles and the interplanar distance in the niobium layers increased, indicating significant lateral compressive stresses. Despite an increase in pressure, the nanohardness and Young’s modulus of the Zr/Nb NMCs remained stable. Increasing the hydrogen concentration to 0.0370 ± 0.0015 wt. % resulted in a 40% increase in nanohardness. At this concentration, the relative values of the Doppler broadening variable energy positron annihilation spectroscopy (S/S0) increased above the initial level, indicating an increase in excess free volume due to hydrogen-induced defects and changes. However, the predominant positron capture center remained intact. The Zr/Nb NMCs with hydrogen content ranging from 0.0150 ± 0.0015 to 0.0180 ± 0.001 wt. % exhibited a decrease in the free volume probed by positrons, as demonstrated by the Doppler broadening variable energy positron annihilation spectroscopy. This was evidenced by opposite changes in S and W (S↓W↑). The microstructural changes are attributed to defect annihilation during hydrogen accumulation near interfaces with the formation of hydrogen–vacancy clusters and hydrides.
- Open Access
Effect of Proton Irradiation on Zr/Nb Nanoscale Multilayer Structure and Properties
The effect of proton irradiation on the structure, phase composition, defect state and nanohardness of Zr/Nb nanoscale multilayer coatings was investigated. Preservation of the Zr/Nb layered structure with 50 and 100 nm thick layers, was observed after irradiation with protons at 1720 keV energy and 3.4 × 1015, 8.6 × 1015 and 3.4 × 1016 ions/cm2 fluences, and the interfaces remained incoherent. In the Zr/Nb nanoscale multilayer coatings with individual layer thicknesses of 10 and 25 nm, there were insignificant fluctuations in interplanar distance, which were influenced by changes in irradiation fluence, and the interfaces were partially destroyed and became semicoherent. Changing irradiation fluence in the investigated ranges led to a decrease in the nanohardness of the Zr/Nb nanoscale multilayer coatings with individual layer thicknesses of 10–50 nm. Variable-energy positron Doppler broadening analysis revealed that these changes are primarily caused by peculiarities of the localization and accumulation of the embedded ions and do not cause a significant increase in the S-parameters of Zr/Nb nanoscale multilayer coatings with a layer thickness less than 100 nm.
Open AccessEffect of Proton Irradiation on Zr/Nb Nanoscale Multilayer Structure and Properties
The effect of proton irradiation on the structure, phase composition, defect state and nanohardness of Zr/Nb nanoscale multilayer coatings was investigated. Preservation of the Zr/Nb layered structure with 50 and 100 nm thick layers, was observed after irradiation with protons at 1720 keV energy and 3.4 × 1015, 8.6 × 1015 and 3.4 × 1016 ions/cm2 fluences, and the interfaces remained incoherent. In the Zr/Nb nanoscale multilayer coatings with individual layer thicknesses of 10 and 25 nm, there were insignificant fluctuations in interplanar distance, which were influenced by changes in irradiation fluence, and the interfaces were partially destroyed and became semicoherent. Changing irradiation fluence in the investigated ranges led to a decrease in the nanohardness of the Zr/Nb nanoscale multilayer coatings with individual layer thicknesses of 10–50 nm. Variable-energy positron Doppler broadening analysis revealed that these changes are primarily caused by peculiarities of the localization and accumulation of the embedded ions and do not cause a significant increase in the S-parameters of Zr/Nb nanoscale multilayer coatings with a layer thickness less than 100 nm.
- Open Access
The Microstructure of Zr/Nb Nanoscale Multilayer Coatings Irradiated with Helium Ions
The effect of helium ion irradiation on the microstructure and properties of composites based on Zr/Nb nanoscale multilayer coatings (NMCs) was studied. X-ray diffraction (XRD), transmission electron microscopy (TEM), and variable-energy Doppler broadening spectroscopy (DBS) were used for the in-depth analysis of defects in the irradiated NMCs. After irradiation of the Zr/Nb NMCs with helium ions at a 1017 ion/cm2 dose, the layered structure was generally retained, but the internal stresses in the layers were increased, which caused wave-like distortion in the ion deposition zone. The Zr/Nb NMCs with an individual layer thickness of 25 nm were characterized by the smallest microstress changes, but single blisters were formed in the near-surface region. The microstructure of the Zr/Nb NMCs with a layer thickness of 100 nm exhibited relatively smaller changes upon helium ion irradiation. The prevailing positron-trapping center was the reduced-electron-density area at the interfaces before and after irradiation of the Zr/Nb NMCs regardless of the layer thickness. However, the layer thickness affected the DBS parameter profiles depending on the positron energy, which was probably due to the different localization of implanted ions within the layers or at the interfaces.
Open AccessThe Microstructure of Zr/Nb Nanoscale Multilayer Coatings Irradiated with Helium Ions
The effect of helium ion irradiation on the microstructure and properties of composites based on Zr/Nb nanoscale multilayer coatings (NMCs) was studied. X-ray diffraction (XRD), transmission electron microscopy (TEM), and variable-energy Doppler broadening spectroscopy (DBS) were used for the in-depth analysis of defects in the irradiated NMCs. After irradiation of the Zr/Nb NMCs with helium ions at a 1017 ion/cm2 dose, the layered structure was generally retained, but the internal stresses in the layers were increased, which caused wave-like distortion in the ion deposition zone. The Zr/Nb NMCs with an individual layer thickness of 25 nm were characterized by the smallest microstress changes, but single blisters were formed in the near-surface region. The microstructure of the Zr/Nb NMCs with a layer thickness of 100 nm exhibited relatively smaller changes upon helium ion irradiation. The prevailing positron-trapping center was the reduced-electron-density area at the interfaces before and after irradiation of the Zr/Nb NMCs regardless of the layer thickness. However, the layer thickness affected the DBS parameter profiles depending on the positron energy, which was probably due to the different localization of implanted ions within the layers or at the interfaces.
- Open Access
Investigation of Nitrogen and Vacancy Defects in Synthetic Diamond Plates by Positron Annihilation Spectroscopy
Currently, diamonds are widely used in science and technology. However, the properties of diamonds due to their defects are not fully understood. In addition to optical methods, positron annihilation spectroscopy (PAS) can be successfully used to study defects in diamonds. Positrons are capable of detecting vacancies, and small and large clusters of vacancies induced by irradiation, by providing information about their size, concentration, and chemical environment. By mapping in the infrared (IR) range, it is possible to consider the admixture composition of the main inclusions of the whole plate. This article presents the results of a study of defects in synthetic diamond plates, one of which was irradiated by electrons. It presents data about the distribution of the defect concentration obtained by Infrared spectroscopy. PAS with a monochromatic positron beam can be used as a non-destructive technique of detecting defects (vacancy) distribution over the depth of diamond plates.
Open AccessInvestigation of Nitrogen and Vacancy Defects in Synthetic Diamond Plates by Positron Annihilation Spectroscopy
Currently, diamonds are widely used in science and technology. However, the properties of diamonds due to their defects are not fully understood. In addition to optical methods, positron annihilation spectroscopy (PAS) can be successfully used to study defects in diamonds. Positrons are capable of detecting vacancies, and small and large clusters of vacancies induced by irradiation, by providing information about their size, concentration, and chemical environment. By mapping in the infrared (IR) range, it is possible to consider the admixture composition of the main inclusions of the whole plate. This article presents the results of a study of defects in synthetic diamond plates, one of which was irradiated by electrons. It presents data about the distribution of the defect concentration obtained by Infrared spectroscopy. PAS with a monochromatic positron beam can be used as a non-destructive technique of detecting defects (vacancy) distribution over the depth of diamond plates.
- Open Access
- 21 November 2022
- Published by MDPI AG in Preprints.org
Investigation of Nitrogen and Vacancy Defects in Synthetic Diamond Plates by Positron Annihilation Spectroscopy
Nowadays, diamonds are widely used in science and technology. However, the properties of diamonds due to their defects are not fully understood. In addition to optical methods, positron annihilation spectroscopy (PAS) can be successfully used to study defects in diamonds. Positrons are capable of detecting vacancies, small and large clusters of vacancies induced by irradiation, by providing information about their size, concentration, and chemical environment. By mapping in the infrared (IR) range, it is possible to consider the admixture composition of the main inclusions of the whole plate. The article presents the results of the study of defects in synthetic diamond plates, one of which was irradiated by electrons. Presents data about the distribution of the defect concentration obtained by Infrared spectroscopy. PAS with a monochromatic positron beam can be used as a non-destructive technique of detecting defects (vacancy) distribution over the depth of diamond plates.
- 21 November 2022
- Published by MDPI AG in Preprints.org
Open AccessInvestigation of Nitrogen and Vacancy Defects in Synthetic Diamond Plates by Positron Annihilation Spectroscopy
Nowadays, diamonds are widely used in science and technology. However, the properties of diamonds due to their defects are not fully understood. In addition to optical methods, positron annihilation spectroscopy (PAS) can be successfully used to study defects in diamonds. Positrons are capable of detecting vacancies, small and large clusters of vacancies induced by irradiation, by providing information about their size, concentration, and chemical environment. By mapping in the infrared (IR) range, it is possible to consider the admixture composition of the main inclusions of the whole plate. The article presents the results of the study of defects in synthetic diamond plates, one of which was irradiated by electrons. Presents data about the distribution of the defect concentration obtained by Infrared spectroscopy. PAS with a monochromatic positron beam can be used as a non-destructive technique of detecting defects (vacancy) distribution over the depth of diamond plates.
- 20 December 2018
- Published by Pleiades Publishing Ltd in Physics of Particles and Nuclei Letters
- Vol. 15 (7) , 975-976
Measurement of Monochromatic Positron Lifetime in a Continuous Flux
A scheme and a setup for the formation of the continuous monochromatic positron flux with a controllable time of arrival at the target independent of the launch time within a limited time interval...
- 20 December 2018
- Published by Pleiades Publishing Ltd in Physics of Particles and Nuclei Letters
- Vol. 15 (7) , 975-976
Measurement of Monochromatic Positron Lifetime in a Continuous Flux
A scheme and a setup for the formation of the continuous monochromatic positron flux with a controllable time of arrival at the target independent of the launch time within a limited time interval...
- 1 September 2015
- Published by Pleiades Publishing Ltd in JETP Letters
- Vol. 102 (5) , 261-265
Mechanism of the accumulation of charged particles in a Penning–Malmberg–Surko trap with a rotating electric field
- 1 September 2015
- Published by Pleiades Publishing Ltd in JETP Letters
- Vol. 102 (5) , 261-265
Mechanism of the accumulation of charged particles in a Penning–Malmberg–Surko trap with a rotating electric field