Emma Olsson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Emma Olsson has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jonas Svensson
Finnish Meteorological Institute, Erik Palménin aukio 1, FI-00506, Helsinki, Finland
3 shared publications - Pernilla Peterson
Medical Radiation Physics, Department of Translational Medicine, Lund University, Skåne University Hospital, Malmö, Sweden
3 shared publications - Björn Lundin
Department of Radiology, University Hospital of Lund, Lund, Sweden
1 shared publication - Carl Johan Tiderius
Department of Orthopaedics Skane University Hospital, Lund University, Lund, Sweden
1 shared publication - Elin Folkesson
Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Orthopaedics, Clinical Epidemiology Unit, Lund, Sweden; Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Rheumatology and Molecular Skeletal Biology, Lund, Sweden
1 shared publication - Emelie Lind
Department of Medical Radiation Physics, Lund University, Barngatan 4, 22185, Lund, Sweden.
1 shared publication
Latest Publications
- 1 March 2019
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 27 (3) , 476-483
Ultra-high field magnetic resonance imaging parameter mapping in the posterior horn of ex vivo human menisci
- 1 March 2019
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 27 (3) , 476-483
Ultra-high field magnetic resonance imaging parameter mapping in the posterior horn of ex vivo human menisci
- 19 September 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (2) , 1044-1051
T2 relaxation time bias in gagCEST at 3T and 7T: comparison of saturation schemes
Purpose To characterize the effects of water T2 relaxation time in the glycosaminoglycan chemical exchange saturation transfer method (gagCEST) and compare them between 3T and 7T as well as between various saturation schemes. Methods Simulations and a phantom experiment were conducted at 3T and 7T in a range of water T2 values and GAG concentrations using various saturation schemes. For both simulations and MRI measurements, unsaturated signal as well as the saturated Z‐spectrum were generated, and the magnetization transfer ratio asymmetry at 1 parts per million was used as a measure of the gagCEST effect size. Results The simulations and phantom experiment results showed a clear GAG concentration and T2 dependence of the gagCEST effect size. Whereas the gagCEST effect size was much larger at 7T, the impact of the T2 bias was more pronounced at 3T. The saturation train length, duty cycle, and average B1 all had clear impact on both the gagCEST effect size and T2 bias. Conclusion The water T2 relaxation is important to consider in gagCEST, especially at 3T. The T2 differences can introduce a pronounced bias, which may obscure the gagCEST effect when using low duty cycles and long saturation trains.
- 19 September 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (2) , 1044-1051
T2 relaxation time bias in gagCEST at 3T and 7T: comparison of saturation schemes
Purpose To characterize the effects of water T2 relaxation time in the glycosaminoglycan chemical exchange saturation transfer method (gagCEST) and compare them between 3T and 7T as well as between various saturation schemes. Methods Simulations and a phantom experiment were conducted at 3T and 7T in a range of water T2 values and GAG concentrations using various saturation schemes. For both simulations and MRI measurements, unsaturated signal as well as the saturated Z‐spectrum were generated, and the magnetization transfer ratio asymmetry at 1 parts per million was used as a measure of the gagCEST effect size. Results The simulations and phantom experiment results showed a clear GAG concentration and T2 dependence of the gagCEST effect size. Whereas the gagCEST effect size was much larger at 7T, the impact of the T2 bias was more pronounced at 3T. The saturation train length, duty cycle, and average B1 all had clear impact on both the gagCEST effect size and T2 bias. Conclusion The water T2 relaxation is important to consider in gagCEST, especially at 3T. The T2 differences can introduce a pronounced bias, which may obscure the gagCEST effect when using low duty cycles and long saturation trains.
- Open Access
- 30 July 2018
- Published by Wiley in Radiology Research and Practice
- Vol. 2018, 1-13
MRI-Based Quantification of Magnetic Susceptibility in Gel Phantoms: Assessment of Measurement and Calculation Accuracy
The local magnetic field inside and around an object in a magnetic resonance imaging unit depends on the magnetic susceptibility of the object being magnetized, in combination with its geometry/orientation. Magnetic susceptibility can thus be exploited as a source of tissue contrast, and susceptibility imaging may also become a useful tool in contrast agent quantification and for assessment of venous oxygen saturation levels. In this study, the accuracy of an established procedure for quantitative susceptibility mapping (QSM) was investigated. Three gel phantoms were constructed with cylinders of varying susceptibility and geometry. Experimental results were compared with simulated and analytically calculated data. An expected linear relationship between estimated susceptibility and concentration of contrast agent was observed. Less accurate QSM-based susceptibility values were observed for cylindrical objects at angles, relative to the main magnetic field, that were close to or larger than the magic angle. Results generally improved for large objects/high spatial resolution and large volume coverage. For simulated phase maps, accurate susceptibility quantification by QSM was achieved also for more challenging geometries. The investigated QSM algorithm was generally robust to changes in measurement and calculation parameters, but experimental phase data of sufficient quality may be difficult to obtain in certain geometries.
- 30 July 2018
- Published by Wiley in Radiology Research and Practice
- Vol. 2018, 1-13
Open AccessMRI-Based Quantification of Magnetic Susceptibility in Gel Phantoms: Assessment of Measurement and Calculation Accuracy
The local magnetic field inside and around an object in a magnetic resonance imaging unit depends on the magnetic susceptibility of the object being magnetized, in combination with its geometry/orientation. Magnetic susceptibility can thus be exploited as a source of tissue contrast, and susceptibility imaging may also become a useful tool in contrast agent quantification and for assessment of venous oxygen saturation levels. In this study, the accuracy of an established procedure for quantitative susceptibility mapping (QSM) was investigated. Three gel phantoms were constructed with cylinders of varying susceptibility and geometry. Experimental results were compared with simulated and analytically calculated data. An expected linear relationship between estimated susceptibility and concentration of contrast agent was observed. Less accurate QSM-based susceptibility values were observed for cylindrical objects at angles, relative to the main magnetic field, that were close to or larger than the magic angle. Results generally improved for large objects/high spatial resolution and large volume coverage. For simulated phase maps, accurate susceptibility quantification by QSM was achieved also for more challenging geometries. The investigated QSM algorithm was generally robust to changes in measurement and calculation parameters, but experimental phase data of sufficient quality may be difficult to obtain in certain geometries.
- Open Access
- 16 May 2018
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 19 (1) , 1-11
Knee dGEMRIC at 7 T: comparison against 1.5 T and evaluation of T1-mapping methods
DGEMRIC (delayed Gadolinium Enhanced Magnetic Resonance Image of Cartilage) is a well-established technique for cartilage quality assessment in osteoarthritis at clinical field strengths. The method is robust, but requires injection of contrast agent and a cumbersome examination procedure. New non-contrast-agent-based techniques for cartilage quality assessment are currently being developed at 7 T. However, dGEMRIC remains an important reference technique during this development. The aim of this work was to compare T1 mapping for dGEMRIC at 7 T and 1.5 T, and to evaluate three T1-mapping methods at 7 T. The knee of 10 healthy volunteers and 9 patients with early signs of cartilage degradation were examined at 1.5 T and 7 T after a single (one) contrast agent injection (Gd-(DTPA)2−). Inversion recovery (IR) sequences were acquired at both field strengths, and at 7 T variable flip angle (VFA) and Look-Locker (LL) sequences were additionally acquired. T1 maps were calculated and average T1 values were estimated within superficial and deep regions-of-interest (ROIs) in the lateral and medial condyles, respectively. T1 values were 1.8 (1.4–2.3) times longer at 7 T. A strong correlation was detected between 1.5 T and 7 T T1 values (r = 0.80). For IR, an additional inversion time was required to avoid underestimation (bias±limits of agreement − 127 ± 234 ms) due to the longer T1 values at 7 T. Out of the two 3D sequences tested, LL resulted in more accurate and precise T1 estimation compared to VFA (average bias±limits of agreement LL: 12 ± 202 ms compared to VFA: 25 ± 622 ms). For both, B1 correction improved agreement to IR. With an adapted sampling scheme, dGEMRIC T1 mapping is feasible at 7 T and correlates well to 1.5 T. If 3D is to be used for T1 mapping of the knee at 7 T, LL is preferred and VFA is not recommended. For VFA and LL, B1 correction is necessary for accurate T1 estimation.
- 16 May 2018
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 19 (1) , 1-11
Open AccessKnee dGEMRIC at 7 T: comparison against 1.5 T and evaluation of T1-mapping methods
DGEMRIC (delayed Gadolinium Enhanced Magnetic Resonance Image of Cartilage) is a well-established technique for cartilage quality assessment in osteoarthritis at clinical field strengths. The method is robust, but requires injection of contrast agent and a cumbersome examination procedure. New non-contrast-agent-based techniques for cartilage quality assessment are currently being developed at 7 T. However, dGEMRIC remains an important reference technique during this development. The aim of this work was to compare T1 mapping for dGEMRIC at 7 T and 1.5 T, and to evaluate three T1-mapping methods at 7 T. The knee of 10 healthy volunteers and 9 patients with early signs of cartilage degradation were examined at 1.5 T and 7 T after a single (one) contrast agent injection (Gd-(DTPA)2−). Inversion recovery (IR) sequences were acquired at both field strengths, and at 7 T variable flip angle (VFA) and Look-Locker (LL) sequences were additionally acquired. T1 maps were calculated and average T1 values were estimated within superficial and deep regions-of-interest (ROIs) in the lateral and medial condyles, respectively. T1 values were 1.8 (1.4–2.3) times longer at 7 T. A strong correlation was detected between 1.5 T and 7 T T1 values (r = 0.80). For IR, an additional inversion time was required to avoid underestimation (bias±limits of agreement − 127 ± 234 ms) due to the longer T1 values at 7 T. Out of the two 3D sequences tested, LL resulted in more accurate and precise T1 estimation compared to VFA (average bias±limits of agreement LL: 12 ± 202 ms compared to VFA: 25 ± 622 ms). For both, B1 correction improved agreement to IR. With an adapted sampling scheme, dGEMRIC T1 mapping is feasible at 7 T and correlates well to 1.5 T. If 3D is to be used for T1 mapping of the knee at 7 T, LL is preferred and VFA is not recommended. For VFA and LL, B1 correction is necessary for accurate T1 estimation.