    DEVELOPMENT OF A TEST SAMPLE OF A SYSTEM FOR GENERATING AND SUPPLYING COMPRESSED AIR FOAM

    by A. Kodryk, O. Titenko, S. Vynohradov, S. Shakhov, D. Hryshchenko

    An effective fire extinguishing agent for class A fires is the compressed air foam formed in Compressed Air Foam Systems (СAFS). Such systems have become widespread in leading countries such as the USA, Germany, China, and others. It is worth noting that the technical parameters of CAFS (intensity and consumption of an aqueous solution of foaming agent/air), implemented in the practice of fire extinguishing in the form of industrial samples, are designed and manufactured in such a way as to ensure effective extinguishing of developed fires of a significant area. When using existing samples for obtaining compression foam, a problem arises, which lies in the limited possibilities of regulating the supply of compression foam (intensity and consumption of the aqueous solution of the foaming agent/air), under which it is possible to use it with modified additives when extinguishing laboratory fires of solid combustible materials, and the lack of a smooth regulation of its supply. As a result of the research, the authors proposed a compressed air foam system to study its properties with the content of modified additives when changing the composition of the liquid and air that make it up. The manufactured system has the following parameters: multiplicity of 4–20, working pressure of systems of 4–8 bar, smooth adjustment of the consumption of aqueous solution/foaming agent of 2–20 l/min, and smooth adjustment of gas fraction consumption of 8–450 l/min. In particular, it is possible to adjust the consumption of the aqueous solution of the foaming agent and air, to work in dependant and autonomous mode, to regulate the intensity of the foam supply using nozzles of different diameters, and to change the porosity of the porous body in the foam generator. Further, we developed a system for measuring the flow of aqueous solution and air, which is a hardware and software complex. The system allows saving the measurement results to a PC in the form of an Excel spreadsheet for further development of dependencies and simultaneously displaying the flow rate of the aqueous foaming agent solution and air on the display screen and PC in real-time. Keywords: compressed air foam, class A fires, compressed air foam systems, modified additives.


  • Open Access

    Influence of modified additives on the properties of compressed air foam

    by Stanislav Shakhov, Stanislav Vynohradov, Anatoly Kodryk, Oleksandr Titenko, Andrii Melnychenko, Dmytry Hryschenko, Evgen Grinchenko, Liudmyla Knaub

    The object of this study is the properties of compressed air foam with the use of modified additives: its drainage time and expansion ratio. The main properties of compressed air foam that affect the effectiveness of fire extinguishing are its drainage time and expansion ratio. At the same time, a number of authors have confirmed that the introduction of chemically modified additives into the composition of water fire extinguishing substances makes it possible to increase the effectiveness of fire extinguishing. The problem to be solved was to determine the influence of five modified additives (NH4)2HPO4, NH4H2PO4, (NH4)2СO3, K2CO3 and KCl in the concentration range of 1–5 % by mass on the expansion ratio and drainage time of the compressed air foam. The results showed that the content of additives (NH4)2HPO4, NH4H2PO4 and (NH4)2СO3 in the aqueous solution of the foaming agent does not affect its expansion ratio within the given limits. On the other hand, with K2CO3 and KCl additives, it was not possible to obtain compressed air foam with a expansion ratio of 5–20, that is, their inefficiency in compressed air foam was noted. The characteristic dependence of the effect of (NH4)2HPO4, NH4H2PO4 and (NH4)2СO3 additives on drainage time has been determined. The greatest drainage time is characteristic of the K≈20 generation mode. The highest recorded drainage time index was established for NH4H2PO4, namely 5.45 min; for (NH4)2HPO4 the drainage time was lower by 8 %; for (NH4)2СO3 the drainage time was lower by 20 %. At the same time, with the use of (NH4)2HPO4, NH4H2PO4 and (NH4)2СO3, it is characteristic to obtain a foam with lower drainage time compared to foam of a conventional composition. Thus, for foam with a expansion ratio of K≈20, the drainage time of foam with NH4H2PO4 is lower by 17 %, with (NH4)2HPO4 by 23 %, and with (NH4)2СO3 by 33 %. The effect of reducing the drainage time of the foam can have a decisive role in reducing its effectiveness when used for extinguishing flammable liquids due to the extinguishing mechanism but is not decisive for extinguishing solid substances. Therefore, the fire-extinguishing effectiveness of compressed air foam with modified additives during the extinguishing of solid combustible materials in comparison with the conventional CAF composition requires further study


  • Open Access

    Procedure for constructing a mathematical model to determine the time of the initial stage of fire evolution

    by Sergii Zhartovskyi, Olexander Titenko, Oksana Kyrychenko, Ievgen Tyshchenko, Roman Motrichuk, Valentyn Melnyk

    To develop appropriate measures and means of fire protection at facilities, it is relevant to form an idea of the phenomenology of the processes of the occurrence, evolution, and termination of combustion. This paper proposes procedures for building mathematical models of the energy component of those physicochemical processes that occur in wood under the influence of fire, which make it possible to determine the time from the beginning of such an impact to the onset of the phase of flame combustion. The adequacy of mathematical modeling was tested experimentally at a standardized installation for studying flame propagation over the surface of wood. The samples used for the reported theoretical and experimental studies were the specimens of unprotected wood made from 20-mm-thick pine sapwood with a density of 400‒550 kg/m3. The samples of fireproof wood (of the same variety, thickness, and density) were impregnated with a fire retardant based on diammonium phosphate and ammonium sulfate (at consumption of 168.2 g/m2 of dry fire-retardant components). The modeling employed the results from the experimental determining of the ignition temperature of unprotected and fire-proof wood, specifically: 235 °C – for unprotected wood, 410 °C – for fire-proof wood, respectively. The results of mathematical modeling and experimental studies confirm the possibility of significant lengthening of time from the onset of fire exposure to the ignition of fire load from wood when nitrogen-phosphorus impregnating agents are used for fire protection. Procedures of mathematical modeling have been proposed to build models for determining the cooling effect from the use of impregnating fire retardants to protect the wood on the prolongation of the stage of a fire start. Mathematical modeling data could be applied when making impregnating fire retardants


  • Open Access

    Визначення залежності характеристик компресійної піни

    by S. M. Shakhov, A. I. Kodryk, O. F. Nikulin, O. M. Titenko, S. A. Vinogradov, І. G. Stylyk

    Проведено теоретичне обґрунтування залежності експлуатаційних характеристик компресійної піни залежно від геометричних розмірів та однорідності бульбашок, що її утворюють. Введено поняття умовної відносної міцності бульбашки як величину відношення площі центрального поперечного перетину бульбашки до її маси бульбашки та наведено формули для його вирахування. Наведено експериментальні залежності експлуатаційних характеристик компресійної піни від геометричних розмірів та гомогенності міхурів, що її утворюють, що дає змогу створювати ефективні системи з утворення КП та здійснювати управління процесами піноутворення та пожежогасіння. Результати досліджень підтверджують, що величини діаметрів міхурів КП та їхня гомогенність, що характеризується полідисперсністю піни, визначають її кратність, яка визначає стійкість та адгезійні властивості піни. У разі збільшення кратності піни, полідисперсність зменшується, тобто гомогенність зростає. Доведено, що існує прямий зв'язок між експлуатаційними характеристиками компресійної піни, такими як: стійкість піни, адгезійна властивість піни, вогнегасна здатність піни та її геометричними характеристиками – розмірами бульбашок та їхня гомогенністю, при чому розміри міхурів та їх гомогенність (полідисперсність) є визначальними параметрами компресійної піни щодо її експлуатаційних характеристик. Технологічні рішення, спрямовані на зменшення розміру бульбашок піни та підвищення її однорідності призведуть до покращення експлуатаційних характеристик компресійної піни та її подальшого впровадження для підвищення ефективності гасіння лісних пожеж.


  • Open Access

    FUNCTIONAL PHYSICAL SCHEME OF THE INSTALLATION FOR THE GENERATION OF COMPRESSED AIR FOAM

    by The Ukrainian Civil Protection Research Institute, O.F. Nikulin, A.I. Kodrik, O.M. Titenko, S.A. Vinogradov, National University of Civil Defence of Ukraine, S.M. Shakhov