DKDavid Keohane

David Keohane

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David Keohane has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The SCARE Score: A Simplified Risk Score for Predicting Intraoperative Neuromonitoring Signal Loss in Pediatric Spinal Deformity Surgery

    by D.M. Moore, D. Keohane, S. Haffey, J. Noel, P. Kiely, P. O’KElly, D.P. Moore, J. Kennedy

    Background: Neurological injury remains one of the most serious complications during pediatric spinal deformity surgery. Intraoperative neuromonitoring (IONM) techniques applied to mitigate the risk of iatrogenic neurological injury allow real-time assessment of the patient’s neurological status. The purpose of this study was to determine which preoperative parameters are associated with IONM signal loss in pediatric spinal deformity surgery, with a view toward constructing an easy-to-use yet statistically robust risk-assessment score. The score should allow surgeons to predict which patients have increased odds of IONM signal loss. Methods: We conducted a retrospective analysis of prospectively collected data from a tertiary pediatric spinal deformity center, including 413 spinal deformity surgeries in 360 patients between 2020 and 2024. The extracted preoperative demographic data underwent univariate and multivariable analysis. Regression coefficients were then employed to construct a simplified clinical risk score, in which each independent predictor was assigned a weighted point value. Significance was defined as p < 0.05. Internal validation was performed with a 70/30 training/testing split and tenfold cross-validation. Results: Neuromonitoring signal loss occurred in 24% of patients. Following univariate and multivariable analysis, the final parsimonious SCARE model included Spinal Cord morphology, deformity Angular ratio, Revision surgery, and syndromic Etiology as independent predictors. Total risk scores range from 0 to 12 points and low risk was considered 0 to 5 points; moderate risk, 6 to 8 points, and high risk, ≥9 points. Observed IONM event rates in these groups were 3.3% to 14.1%, 18.4% to 29.7%, and 36.6% to 59.7%, respectively. The point-based risk score achieved an area under the receiver operating characteristic curve of ≈0.74 on the testing data. Conclusions: The SCARE score is a predictive, internally validated, simple, and memorizable preoperative tool for estimating the IONM signal loss risk in pediatric spinal deformity surgery. While further external validation is essential, we hope that it will aid surgical planning, inform perioperative discussions, and contribute to safer management of children with spinal deformities. Level of Evidence: Prognostic Level IV . See Instructions for Authors for a complete description of levels of evidence.

  • Open Access

    Systematic review of multivariable prognostic models for outcomes at least 30 days after hip fracture finds 18 mortality models but no nonmortality models warranting validation

    by Mary E. Walsh, Pia Kjær Kristensen, Thomas J. Hjelholt, Conor Hurson, Cathal Walsh, Helena Ferris, Geoff Crozier-Shaw, David Keohane, Ellen Geary, Amanda O'Halloran, et al.


  • A prospective review of Cauda Equina Syndrome referrals received by an on-call orthopaedic department at a major trauma unit

    by David Keohane, Niall P. McGoldrick, John F. Quinlan

    Introduction Cauda Equina Syndrome (CES) is one of the genuine orthopaedic emergencies. Diagnosis of acute CES is challenging and may be missed, resulting in considerable medicolegal claims. In Ireland, nearly €21 million in compensation has been paid out over a 10-year period due to the diagnosis being missed. As a result, defensive practices have resulted in an increased number of referrals for CES to the on-call orthopaedic service in a major trauma unit. Methods A prospective data-capturing exercise was carried out of all referrals for acute CES to the orthopaedic on-call department in a tertiary-level university-affiliated teaching hospital between August and November 2023. Qualitative data was captured including referral source, referring clinician grade, in-hours or out-of-hours referral, MRI on referral, red flags as identified by the referring team, red flags as identified by the orthopaedic team, and outcome. Results Forty referrals for CES were made over the duration of this audit. Seventeen (42.5%) referrals were made in-hours, and 23 (57.5%) were referred out-of-hours. Only five (12.5%) of these referrals had an MRI done at the time of the referral. No patients were transferred for an out-of-hours MRI to another hospital. Only five (12.5%) patients required surgical decompression—none of these patients required an out-of-hours emergent decompression. Conclusion There is a lack of understanding as to what exactly is being referred—resulting in a referral volume which is over ten times the expected number of CES cases being made to our unit. The lack of out-of-hours MRI access poses a significant concern for patient outcomes.


  • Hip fracture surgery within 36 hours reduces both 30-day and 1-year mortality rates

    by David Keohane, Colum Downey, Gerard A. Sheridan, Patrick O'KElly, John F. Quinlan


  • Open Access

    High rate of tibial debonding and failure in a popular knee replacement

    by David Keohane, Gerard A. Sheridan, Eric Masterson

    Aims: Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component. Methods: A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option). Results: Between 2013 and 2016, 352 NexGen TKAs were carried out on 331 patients. A total of 62 TKAs have been revised to date, giving an all-cause revision rate of 17.6% at a minimum of five years. Three of these revisions were due to infection. Overall, 59 of the revisions were performed for aseptic loosening (16.7%) of the tibial component. The tibial component was removed intraoperatively without instrumentation due to significant tibial debonding between the implant-cement interface. Conclusion: While overall, we believe that early aseptic loosening is multi-factorial in nature, the significantly high aseptic revision rate, as seen by an experienced fellowship-trained arthroplasty surgeon, has led us to believe that there is a fundamental issue with this NexGen implant design. Continued implant surveillance and rigorous review across all regions using this particular implant is warranted based on the concerning findings described here. Cite this article: Bone Jt Open 2022;3(6):495–501.


  • Repair of sternoclavicular joint ligament: a novel approach

    by David Keohane, David Morrissey

    Background Posterior sternoclavicular dislocations are common in younger patients and are frequently due to high energy sporting incidents. Aim We aim to demonstrate a novel technique that is safe and aims to provide good functional post-operative outcomes for patients with this injury. Methods This was a single-surgeon case series of four young patients from October 2017 to July 2019. The operative technique involved relocating the joint and holding it in situ with nylon suture tape. The tape was anchored in holes drilled in the sternum and passed through tunnels drilled into the medial clavicle. All of the patients were contacted retrospectively and a Nottingham Clavicle Score (NCS) was performed for each patient on a post-operative basis. Results No intra-operative or post-operative complications were noted. All of the patients demonstrated a significant improvement in their functional outcomes after the operation. The average NCS for the four patients was 82/100. Discussion There are a variety of techniques described in the literature to repair this ligament using either plates or tendon grafts. All of these techniques describe the drilling of anteroposterior holes in the manubrium and clavicle which run the intra-operative risk of perforating a major vessel. This paper is the first one to describe a technique which uses superior inferior holes which minimizes the risks, making the procedure safer for the patient. Conclusions We believe this novel technique is safer than the existing described techniques, and it does not compromise on functional outcomes.


  • Correction to: Assessing outcomes in hip fracture patients under the age of 60

    by David Keohane, Laith Al Azawi, Colum Downey, John F. Quinlan

  • Open Access

    Nontraumatic Tibial Polyethylene Insert Cone Fracture in Rotating-Platform Total Knee Arthroplasty

    by Cillian J. Keogh, David Keohane, James A. Harty, David Mulcahy


  • Assessing outcomes in hip fracture patients under the age of 60

    by David Keohane, Laith Al Azawi, Colum Downey, John F. Quinlan, Acolum Downey

    Background Hip fractures are a common and serious orthopaedic injury. The principle of treatment for hip fractures in the “non-elderly” patient is to preserve the native hip. There is limited published literature in this area. Aim The aim of this research is to review all of the “non-elderly” hip fracture patients to report on the demographics, fracture patterns, fixation types, and revisions. Methods This was a retrospective single-site review of all of the “non-elderly” patients who underwent operative management for hip fractures between 1999 and 2019. A manual review was done of all of the x-rays for the identified patients to confirm the fracture type and identify further surgeries. Results Three hundred and eighty-one patients were identified. The average age was 48.4 years old. Two hundred and thirty nine of them were intra-capsular, and 142 of them were extra-capsular fractures. Dynamic hip screw (DHS) was the most popular fixation method. In the recent decade of data, the number of hemi-arthroplasties remained consistent, but the number of total hip arthroplasties (THAs) performed increased sevenfold. Mean follow-up was 35 months. Forty-three (11%) patients required follow-up surgery. Non-union accounted for 56% of all revisions and avascular necrosis for 19%. THA was performed in 70% of all revisions. Conclusion DHS remains the most widely used fixation technique in an effort to preserve the native hip. The use of THA has increased and surpassed the usage of hemi-arthroplasty in recent times. A high proportion of these patients will go on to develop complications requiring secondary surgery; therefore, they all need long-term follow-up.


  • Polyethylene liner dissociation in a DePuy pinnacle cup with a manufacturer analysis of the failed component

    by David Keohane, Gerard A Sheridan, James Harty, Padhraig O'LOughlin

    A 74-year-old patient presented to the emergency department with acute atraumatic hip pain 9 years after her primary left total hip arthroplasty (THA). Plain radiographic imaging demonstrated lateralisation of the femoral head within the acetabular shell—indicating an issue with the polyethylene liner. The patient required revision of the acetabular component and the femoral head, as well as a new polyethylene liner. A detailed analysis of the components removed was performed by DePuy Synthes Engineering. Between 2009 and 2020, 8 publications have documented 52 cases of liner dissociation with the Pinnacle acetabular component and Marathon polyethylene liner. Various theories have been proposed in the literature as all of these components appear to fail in the same way, with shearing of the locking tabs in the polyethylene liner. In spite of a manufacturer analysis of the components, no root cause was identified as to why the polyethylene liner failed.