Zhenlu Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhenlu Yang has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Rongpin Wang
Department of Radiology, Guizhou Provincial People’s Hospital, Guiyang, China
3 shared publications - Liming Xia
Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Tao Ai
Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Ying Zhao
Department of Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, 210006, China
2 shared publications Zi Xu
Guizhou Province International Science and Technology Cooperation Base for Precision Imaging Diagnosis and Treatment, Key Laboratory of Advanced Medical Imaging and Intelligent Computing of Guizhou Province, Department of Radiology, Guizhou Provincial People’s Hospital, Guiyang, China
2 shared publicationsCaili Tang
Department of Radiology Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology Wuhan China
1 shared publication
Latest Publications
- Open Access
- 11 April 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
AES-SDM meta-analysis of spontaneous brain activity in cerebral small vessel disease
Cerebral small vessel disease (CSVD) is a major cause of vascular cognitive impairment and dementia, characterized by microvascular dysfunction and disrupt
- 11 April 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Open AccessAES-SDM meta-analysis of spontaneous brain activity in cerebral small vessel disease
Cerebral small vessel disease (CSVD) is a major cause of vascular cognitive impairment and dementia, characterized by microvascular dysfunction and disrupt
- 4 November 2024
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 7 (11) , 7133-7169
Recent Advances in Silica-Based Nanomaterials for Enhanced Tumor Imaging and Therapy
Cancer remains a formidable challenge, inflicting profound physical, psychological, and financial burdens on patients. In this context, silica-based nanomaterials have garnered significant attention for their potential in tumor imaging and therapy owing to their exceptional properties, such as biocompatibility, customizable porosity, and versatile functionalization capabilities. This review meticulously examines the latest advancements in the application of silica-based nanomaterials for tumor imaging and therapy. It underscores their potential in enhancing various cancer imaging modalities, including fluorescence imaging, magnetic resonance imaging, computed tomography, positron emission tomography, ultrasound imaging, and multimodal imaging approaches. Moreover, the review delves into their therapeutic efficacy in chemotherapy, radiotherapy, phototherapy, immunotherapy, gas therapy, sonodynamic therapy, chemodynamic therapy, starvation therapy, and gene therapy. Critical evaluations of the biosafety profiles and degradation pathways of these nanomaterials within biological environments are also presented. By discussing the current challenges and prospects, this review aims to provide a nuanced perspective on the clinical translation of silica-based nanomaterials, thereby highlighting their promise in revolutionizing cancer diagnostics, enabling real-time monitoring of therapeutic responses, and advancing personalized medicine.
- 4 November 2024
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 7 (11) , 7133-7169
Recent Advances in Silica-Based Nanomaterials for Enhanced Tumor Imaging and Therapy
Cancer remains a formidable challenge, inflicting profound physical, psychological, and financial burdens on patients. In this context, silica-based nanomaterials have garnered significant attention for their potential in tumor imaging and therapy owing to their exceptional properties, such as biocompatibility, customizable porosity, and versatile functionalization capabilities. This review meticulously examines the latest advancements in the application of silica-based nanomaterials for tumor imaging and therapy. It underscores their potential in enhancing various cancer imaging modalities, including fluorescence imaging, magnetic resonance imaging, computed tomography, positron emission tomography, ultrasound imaging, and multimodal imaging approaches. Moreover, the review delves into their therapeutic efficacy in chemotherapy, radiotherapy, phototherapy, immunotherapy, gas therapy, sonodynamic therapy, chemodynamic therapy, starvation therapy, and gene therapy. Critical evaluations of the biosafety profiles and degradation pathways of these nanomaterials within biological environments are also presented. By discussing the current challenges and prospects, this review aims to provide a nuanced perspective on the clinical translation of silica-based nanomaterials, thereby highlighting their promise in revolutionizing cancer diagnostics, enabling real-time monitoring of therapeutic responses, and advancing personalized medicine.
- 24 October 2024
- Published by Springer Nature in GeroScience
- Vol. 47 (2) , 2135-2148
An explainable machine learning estimated biological age based on morphological parameters of the spine
Accurately estimating biological age is beneficial for measuring aging and predicting risk. It is widely accepted that the prevalence of spine compression increases significantly with age. However, biological age based on vertebral morphological data is rarely reported. In this study, a total of 2,364 participants from the National Health and Nutrition Examination Survey were enrolled, and morphological parameters of the spine were collected from lateral radiographs scanned by dual energy X-ray absorptiometry. The biological age of the spine, called SpineAge, was calculated with the parameters by machine learning models. The SHapley Additive exPlanation was used for better interpreting each parameter's contribution. Besides, an Accelerated Aging Index (AAI) was defined as SpineAge minus chronological age and was used to quantify the accelerating aging degree of the spine. The results indicated that the SpineAge performed better than chronological age did in predicting 2-year and 5-year all-cause mortality. After adjusting all covariates, there was a significant association between AAI and all-cause mortality risk. Specifically, each 1-year increase in AAI was associated with a 25.9% increase in all-cause mortality risk (Hazards ratio, 1.259; 95% CI, 1.087–1.457; P < 0.001). Considering the first quartile of AAI as a reference, the mortality risks for the second, third, and fourth quartiles were 2.389 (95% CI, 1.064–5.364; P = 0.035), 5.911 (95% CI, 2.241–15.590; P < 0.001) and 22.925 (95% CI, 4.744–110.769; P < 0.001) times higher, respectively. Our study developed a novel and highly applicable biological-age predictor for predicting individualized long-term prognosis and facilitating personalized care. Graphical Abstract
- 24 October 2024
- Published by Springer Nature in GeroScience
- Vol. 47 (2) , 2135-2148
An explainable machine learning estimated biological age based on morphological parameters of the spine
Accurately estimating biological age is beneficial for measuring aging and predicting risk. It is widely accepted that the prevalence of spine compression increases significantly with age. However, biological age based on vertebral morphological data is rarely reported. In this study, a total of 2,364 participants from the National Health and Nutrition Examination Survey were enrolled, and morphological parameters of the spine were collected from lateral radiographs scanned by dual energy X-ray absorptiometry. The biological age of the spine, called SpineAge, was calculated with the parameters by machine learning models. The SHapley Additive exPlanation was used for better interpreting each parameter's contribution. Besides, an Accelerated Aging Index (AAI) was defined as SpineAge minus chronological age and was used to quantify the accelerating aging degree of the spine. The results indicated that the SpineAge performed better than chronological age did in predicting 2-year and 5-year all-cause mortality. After adjusting all covariates, there was a significant association between AAI and all-cause mortality risk. Specifically, each 1-year increase in AAI was associated with a 25.9% increase in all-cause mortality risk (Hazards ratio, 1.259; 95% CI, 1.087–1.457; P < 0.001). Considering the first quartile of AAI as a reference, the mortality risks for the second, third, and fourth quartiles were 2.389 (95% CI, 1.064–5.364; P = 0.035), 5.911 (95% CI, 2.241–15.590; P < 0.001) and 22.925 (95% CI, 4.744–110.769; P < 0.001) times higher, respectively. Our study developed a novel and highly applicable biological-age predictor for predicting individualized long-term prognosis and facilitating personalized care. Graphical Abstract
- Open Access
- 16 May 2024
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 5 (13) , 5482-5493
A graphene oxide-based sequential nanocatalyst for efficient tumor combination therapy
Graphene oxide (GO) is a versatile and promising nanomaterial, and it can mimic peroxidase-like activity to generate hydroxyl radicals to kill tumor cells. However, the low biocompatibility and catalytic efficiency limit its application in tumor treatment. Here, we constructed a sequential catalytic nanocatalyst based on GO to overcome its drawbacks and improve the therapeutic effect. GO nanosheets were coated onto periodic mesoporous organosilica (PMOs) and then glucose oxidase (GOD) was modified on the surface to create PMO@GO-GOD. The GO-wrapping of the PMOs could reduce the damage of the two-dimensional GO nanosheets in the cell membrane. The loaded GOD decomposed glucose into H2O2 to continually supply the catalytic substrate for GO and thus enhanced its catalytic performance. Meanwhile, effective photothermal therapy could be achieved by GO shells. The administration of PMO@GO-GOD resulted in a remarkable antitumor effect with no obvious systemic toxicity.
- 16 May 2024
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 5 (13) , 5482-5493
Open AccessA graphene oxide-based sequential nanocatalyst for efficient tumor combination therapy
Graphene oxide (GO) is a versatile and promising nanomaterial, and it can mimic peroxidase-like activity to generate hydroxyl radicals to kill tumor cells. However, the low biocompatibility and catalytic efficiency limit its application in tumor treatment. Here, we constructed a sequential catalytic nanocatalyst based on GO to overcome its drawbacks and improve the therapeutic effect. GO nanosheets were coated onto periodic mesoporous organosilica (PMOs) and then glucose oxidase (GOD) was modified on the surface to create PMO@GO-GOD. The GO-wrapping of the PMOs could reduce the damage of the two-dimensional GO nanosheets in the cell membrane. The loaded GOD decomposed glucose into H2O2 to continually supply the catalytic substrate for GO and thus enhanced its catalytic performance. Meanwhile, effective photothermal therapy could be achieved by GO shells. The administration of PMO@GO-GOD resulted in a remarkable antitumor effect with no obvious systemic toxicity.
- 3 February 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (3) , 963-974
Contrasts Between Diffusion‐Weighted Imaging and Dynamic Contrast‐Enhanced MR in Diagnosing Malignancies of Breast Nonmass Enhancement Lesions Based on Morphologic Assessment
Background: Nonmass enhancement (NME) breast lesions are considered to be the leading cause of unnecessary biopsies. Diffusion‐weighted imaging (DWI) or dynamic contrast‐enhanced (DCE) sequences are typically used to differentiate between benign and malignant NMEs. It is important to know which one is more effective and reliable.Purpose: To compare the diagnostic performance of DCE curves and DWI in discriminating benign and malignant NME lesions on the basis of morphologic characteristics assessment on contrast‐enhanced (CE)‐MRI images.Study Type: Retrospective.Subjects: A total of 180 patients with 184 lesions in the training cohort and 75 patients with 77 lesions in the validation cohort with pathological results.Field Strength/Sequence: A 3.0 T/multi‐b‐value DWI (b values = 0, 50, 1000, and 2000 sec/mm2) and time‐resolved angiography with stochastic trajectories and volume‐interpolated breath‐hold examination (TWIST‐VIBE) sequence.Assessment: In the training cohort, a diagnostic model for morphology based on the distribution and internal enhancement characteristics was first constructed. The apparent diffusion coefficient (ADC) model (ADC + morphology) and the time‐intensity curves (TIC) model (TIC + morphology) were then established using binary logistic regression with pathological results as the reference standard. Both models were compared for sensitivity, specificity, and area under the curve (AUC) in the training and the validation cohort.Statistical Tests: Receiver operating characteristic (ROC) curve analysis and two‐sample t‐tests/Mann–Whitney U‐test/Chi‐square test were performed. P < 0.05 was considered statistically significant.Results: For the TIC/ADC model in the training cohort, sensitivities were 0.924/0.814, specificities were 0.615/0.615, and AUCs were 0.811 (95%, 0.727, 0.894)/0.769 (95%, 0.681, 0.856). The AUC of the TIC‐ADC combined model was significantly higher than ADC model alone, while comparable with the TIC model (P = 0.494). In the validation cohort, the AUCs of TIC/ADC model were 0.799/0.635.Data Conclusion: Based on the morphologic analyses, the performance of the TIC model was found to be superior than the ADC model for differentiating between benign and malignant NME lesions.Evidence Level: 4.Technical Efficacy: Stage 2.
- 3 February 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (3) , 963-974
Contrasts Between Diffusion‐Weighted Imaging and Dynamic Contrast‐Enhanced MR in Diagnosing Malignancies of Breast Nonmass Enhancement Lesions Based on Morphologic Assessment
Background: Nonmass enhancement (NME) breast lesions are considered to be the leading cause of unnecessary biopsies. Diffusion‐weighted imaging (DWI) or dynamic contrast‐enhanced (DCE) sequences are typically used to differentiate between benign and malignant NMEs. It is important to know which one is more effective and reliable.Purpose: To compare the diagnostic performance of DCE curves and DWI in discriminating benign and malignant NME lesions on the basis of morphologic characteristics assessment on contrast‐enhanced (CE)‐MRI images.Study Type: Retrospective.Subjects: A total of 180 patients with 184 lesions in the training cohort and 75 patients with 77 lesions in the validation cohort with pathological results.Field Strength/Sequence: A 3.0 T/multi‐b‐value DWI (b values = 0, 50, 1000, and 2000 sec/mm2) and time‐resolved angiography with stochastic trajectories and volume‐interpolated breath‐hold examination (TWIST‐VIBE) sequence.Assessment: In the training cohort, a diagnostic model for morphology based on the distribution and internal enhancement characteristics was first constructed. The apparent diffusion coefficient (ADC) model (ADC + morphology) and the time‐intensity curves (TIC) model (TIC + morphology) were then established using binary logistic regression with pathological results as the reference standard. Both models were compared for sensitivity, specificity, and area under the curve (AUC) in the training and the validation cohort.Statistical Tests: Receiver operating characteristic (ROC) curve analysis and two‐sample t‐tests/Mann–Whitney U‐test/Chi‐square test were performed. P < 0.05 was considered statistically significant.Results: For the TIC/ADC model in the training cohort, sensitivities were 0.924/0.814, specificities were 0.615/0.615, and AUCs were 0.811 (95%, 0.727, 0.894)/0.769 (95%, 0.681, 0.856). The AUC of the TIC‐ADC combined model was significantly higher than ADC model alone, while comparable with the TIC model (P = 0.494). In the validation cohort, the AUCs of TIC/ADC model were 0.799/0.635.Data Conclusion: Based on the morphologic analyses, the performance of the TIC model was found to be superior than the ADC model for differentiating between benign and malignant NME lesions.Evidence Level: 4.Technical Efficacy: Stage 2.
- Top Cited Papers
- 1 August 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 296 (2) , E32-E40
Correlation of Chest CT and RT-PCR Testing for Coronavirus Disease 2019 (COVID-19) in China: A Report of 1014 Cases
Background Chest CT is used for diagnosis of 2019 novel coronavirus disease (COVID-19), as an important complement to the reverse-transcription polymerase chain reaction (RT-PCR) tests. Purpose To ...
- 1 August 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 296 (2) , E32-E40
Top Cited PapersCorrelation of Chest CT and RT-PCR Testing for Coronavirus Disease 2019 (COVID-19) in China: A Report of 1014 Cases
Background Chest CT is used for diagnosis of 2019 novel coronavirus disease (COVID-19), as an important complement to the reverse-transcription polymerase chain reaction (RT-PCR) tests. Purpose To ...
- 10 December 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (1) , 187-194
Sensitive, Real-Time, and In-Vivo Oxygen Monitoring for Photodynamic Therapy by Multifunctional Mesoporous Nanosensors
Real-time monitoring of oxygen consumption is beneficial to predict treatment response and optimize therapeutic protocols for photodynamic therapy (PDT). In this work, we first demonstrate that deformable hollow mesoporous organosilica nanoparticles (HMONs) can be used to load [(Ru(dpp)3)]Cl2 for detecting oxygen (denoted as HMON-[(Ru(dpp)3)]Cl2). This nanoprobe shows significantly improved biocompatibility and high cellular uptake. In-vitro eperiments demonstrate that the HMON-[(Ru(dpp)3)]Cl2 can sensitively detect oxygen changes between 1 %-20 %. On this basis, photosensitizer chlorin e6 (Ce6) and [(Ru(dpp)3)]Cl2 are simultaneously loaded in the HOMNs (denoted as HMON-Ce6-[(Ru(dpp)3)]Cl2) for real-time oxygen monitoring during photodynamic therapy. The HMON-Ce6-[(Ru(dpp)3)]Cl2 can reflects oxygen consumption in solution and cells in photodynamic therapy. Furthermore, the ability of HMON-Ce6-[(Ru(dpp)3)]Cl2 nanosensor to monitor oxygen changes is demonstrated in tumor-bearing nude mice.
- 10 December 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (1) , 187-194
Sensitive, Real-Time, and In-Vivo Oxygen Monitoring for Photodynamic Therapy by Multifunctional Mesoporous Nanosensors
Real-time monitoring of oxygen consumption is beneficial to predict treatment response and optimize therapeutic protocols for photodynamic therapy (PDT). In this work, we first demonstrate that deformable hollow mesoporous organosilica nanoparticles (HMONs) can be used to load [(Ru(dpp)3)]Cl2 for detecting oxygen (denoted as HMON-[(Ru(dpp)3)]Cl2). This nanoprobe shows significantly improved biocompatibility and high cellular uptake. In-vitro eperiments demonstrate that the HMON-[(Ru(dpp)3)]Cl2 can sensitively detect oxygen changes between 1 %-20 %. On this basis, photosensitizer chlorin e6 (Ce6) and [(Ru(dpp)3)]Cl2 are simultaneously loaded in the HOMNs (denoted as HMON-Ce6-[(Ru(dpp)3)]Cl2) for real-time oxygen monitoring during photodynamic therapy. The HMON-Ce6-[(Ru(dpp)3)]Cl2 can reflects oxygen consumption in solution and cells in photodynamic therapy. Furthermore, the ability of HMON-Ce6-[(Ru(dpp)3)]Cl2 nanosensor to monitor oxygen changes is demonstrated in tumor-bearing nude mice.