Ting Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ting Feng has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Jing Xu
National Institute of Parasitic Diseases, Chinese Center for Disease Control and Prevention (Chinese Center for Tropical Diseases Research), NHC Key Laboratory of Parasite and Vector Biology, WHO Collaborating Centre for Tropical Diseases, National Center for International Research on Tropical Diseases, Shanghai 200025, China
3 shared publications - Chao Lv
School of Global Health, Chinese Center for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
2 shared publications - Robert Bergquist
Geospatial Health, Ingerod, Brastad, Sweden
2 shared publications - Shan Lv
National Institute of Parasitic Diseases, Chinese Center for Disease Control and Prevention (Chinese Center for Tropical Diseases Research), Shanghai 200025, China
2 shared publications - Xiao-Nong Zhou
School of Global Health, Chinese Center for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, Shanghai, China
2 shared publications - Yinlong Li
National Institute of Parasitic Disease, Chinese Center for Disease Control and Prevention (Chinese Center for Tropical Disease Research), NHC Key Laboratory of Parasite and Vector Biology, WHO Collaborating Center for Tropical Disease, National Center for International Research on Tropical Disease, Shanghai 200025, China
2 shared publications
Latest Publications
- Open Access
- 11 June 2026
- Published by MDPI AG in Tropical Medicine and Infectious Disease
- Vol. 11 (6) , 157
Rapid and Sensitive Detection of Schistosoma mansoni in the Intermediate Snail Hosts Using Loop-Mediated Isothermal Amplification (LAMP) Diagnostics
Schistosomiasis is an important snail-borne neglected tropical disease, and detecting infected snails is a priority for its control and elimination. However, conventional parasitological methods, such as crushed snails and cercarial shedding, have limited sensitivity. In this study, we developed a novel loop-mediated isothermal amplification (LAMP) assay (smND1-LAMP) targeting the mitochondrial NADH dehydrogenase subunit 1 (ND1) gene of Schistosoma mansoni. The assay was optimized at 65 °C for 1 h and demonstrated a detection limit of one copy of the pUC57/smND1 recombinant plasmid. Its diagnostic performance was evaluated using laboratory-infected Biomphalaria snails and field-collected samples from Zimbabwe and Burkina Faso, and compared with microscopy, conventional PCR and SYBR Green real-time PCR (SGPCR). In laboratory experiments, smND1-LAMP achieved 100% specificity and 75% sensitivity, outperforming microscopy and showing a similar performance to SGPCR. In field surveys, smND1-LAMP detected a higher positive rate (25.9%) than conventional PCR (22.2%) in Burkina Faso, while microscopy failed to identify any positive snails. Both molecular methods identified infections that were missed by parasitological techniques. These findings demonstrate that smND1-LAMP assay is a sensitive, specific, and field-applicable tool for detecting S. mansoni infection in snails. It provides an effective alternative for routine surveillance and early warning of changing schistosomiasis endemicity.
- 11 June 2026
- Published by MDPI AG in Tropical Medicine and Infectious Disease
- Vol. 11 (6) , 157
Open AccessRapid and Sensitive Detection of Schistosoma mansoni in the Intermediate Snail Hosts Using Loop-Mediated Isothermal Amplification (LAMP) Diagnostics
Schistosomiasis is an important snail-borne neglected tropical disease, and detecting infected snails is a priority for its control and elimination. However, conventional parasitological methods, such as crushed snails and cercarial shedding, have limited sensitivity. In this study, we developed a novel loop-mediated isothermal amplification (LAMP) assay (smND1-LAMP) targeting the mitochondrial NADH dehydrogenase subunit 1 (ND1) gene of Schistosoma mansoni. The assay was optimized at 65 °C for 1 h and demonstrated a detection limit of one copy of the pUC57/smND1 recombinant plasmid. Its diagnostic performance was evaluated using laboratory-infected Biomphalaria snails and field-collected samples from Zimbabwe and Burkina Faso, and compared with microscopy, conventional PCR and SYBR Green real-time PCR (SGPCR). In laboratory experiments, smND1-LAMP achieved 100% specificity and 75% sensitivity, outperforming microscopy and showing a similar performance to SGPCR. In field surveys, smND1-LAMP detected a higher positive rate (25.9%) than conventional PCR (22.2%) in Burkina Faso, while microscopy failed to identify any positive snails. Both molecular methods identified infections that were missed by parasitological techniques. These findings demonstrate that smND1-LAMP assay is a sensitive, specific, and field-applicable tool for detecting S. mansoni infection in snails. It provides an effective alternative for routine surveillance and early warning of changing schistosomiasis endemicity.
- Open Access
Laboratory Evaluation of a Basic Recombinase Polymerase Amplification (RPA) Assay for Early Detection of Schistosoma japonicum
Early detection of Schistosoma japonicum (S. japonicum) within its intermediate and definitive hosts is crucial for case finding and disease surveillance, especially in low-endemic areas. Recombinase polymerase amplification (RPA) has many advantages over traditional methods of DNA-amplification, such as polymerase chain reaction (PCR), including high sensitivity and specificity whilst being deployable in resource-poor schistosomiasis-endemic areas. Here, we evaluated the performance of a basic RPA assay targeting the 28srDNA gene fragment of S. japonicum (Sj28srDNA) using schistosome-infected Oncomelania hupensis (O. hupensis) and mouse models, compared to the traditional pathological method and a PCR assay. Overall S. japonicum infection prevalence within O. hupensis hosts by microscopic dissection, PCR and RPA was 9.29% (13/140), 32.14% (45/140) and 51.43% (72/140), respectively, presenting significant differences statistically (χ2 = 58.31, p < 0.001). It was noteworthy that infection prevalence by PCR and RPA performed was 34.44% (31/90) and 53.33% (48/90) in snails within 6 weeks post-infection, while the dissection method detected all samples as negatives. In addition, the basic RPA assay presented positive results from the fourth week post-infection and third day post-infection when detecting fecal DNA and serum DNA, respectively, which were extracted from a pooled sample from mice infected with 20 S. japonicum cercariae. This study suggests that the RPA assay has high potential for early detection of S. japonicum infection within its intermediate and definitive hosts.
Open AccessLaboratory Evaluation of a Basic Recombinase Polymerase Amplification (RPA) Assay for Early Detection of Schistosoma japonicum
Early detection of Schistosoma japonicum (S. japonicum) within its intermediate and definitive hosts is crucial for case finding and disease surveillance, especially in low-endemic areas. Recombinase polymerase amplification (RPA) has many advantages over traditional methods of DNA-amplification, such as polymerase chain reaction (PCR), including high sensitivity and specificity whilst being deployable in resource-poor schistosomiasis-endemic areas. Here, we evaluated the performance of a basic RPA assay targeting the 28srDNA gene fragment of S. japonicum (Sj28srDNA) using schistosome-infected Oncomelania hupensis (O. hupensis) and mouse models, compared to the traditional pathological method and a PCR assay. Overall S. japonicum infection prevalence within O. hupensis hosts by microscopic dissection, PCR and RPA was 9.29% (13/140), 32.14% (45/140) and 51.43% (72/140), respectively, presenting significant differences statistically (χ2 = 58.31, p < 0.001). It was noteworthy that infection prevalence by PCR and RPA performed was 34.44% (31/90) and 53.33% (48/90) in snails within 6 weeks post-infection, while the dissection method detected all samples as negatives. In addition, the basic RPA assay presented positive results from the fourth week post-infection and third day post-infection when detecting fecal DNA and serum DNA, respectively, which were extracted from a pooled sample from mice infected with 20 S. japonicum cercariae. This study suggests that the RPA assay has high potential for early detection of S. japonicum infection within its intermediate and definitive hosts.
- Open Access
- 15 December 2018
- Published by MDPI AG in Tropical Medicine and Infectious Disease
- Vol. 3 (4) , 124
Field Evaluation of a Loop-Mediated Isothermal Amplification (LAMP) Platform for the Detection of Schistosoma japonicum Infection in Oncomelania hupensis Snails
Schistosoma infection in snails can be monitored by microscopy or indirectly by sentinel mice. As both these approaches can miss infections, more sensitive tests are needed, particularly in low-level transmission settings. In this study, loop-mediated isothermal amplification (LAMP) technique, designed to detect a specific 28S ribosomal Schistosoma japonicum (Sj28S) gene with high sensitivity, was compared to microscopy using snail samples from 51 areas endemic for schistosomiasis in five Chinese provinces. In addition, the results were compared with those from polymerase chain reaction (PCR) by adding DNA sequencing as a reference. The testing of pooled snail samples with the LAMP assay showed that a dilution factor of 1/50, i.e., one infected snail plus 49 non-infected ones, would still result in a positive reaction after the recommended number of amplification cycles. Testing a total of 232 pooled samples, emanating from 4006 snail specimens, showed a rate of infection of 6.5%, while traditional microscopy found only 0.4% positive samples in the same materials. Parallel PCR analysis confirmed the diagnostic accuracy of the LAMP assay, with DNA sequencing even giving LAMP a slight lead. Microscopy and the LAMP test were carried out at local schistosomiasis-control stations, demonstrating that the potential of the latter assay to serve as a point-of-care (POC) test with results available within 60–90 min, while the more complicated PCR test had to be carried out at the National Institute of Parasitic Diseases (NIPD) in Shanghai, China. In conclusion, LAMP was found to be clearly superior to microscopy and as good as, or better than, PCR. As it can be used under field conditions and requires less time than other techniques, LAMP testing would improve and accelerate schistosomiasis control.
- 15 December 2018
- Published by MDPI AG in Tropical Medicine and Infectious Disease
- Vol. 3 (4) , 124
Open AccessField Evaluation of a Loop-Mediated Isothermal Amplification (LAMP) Platform for the Detection of Schistosoma japonicum Infection in Oncomelania hupensis Snails
Schistosoma infection in snails can be monitored by microscopy or indirectly by sentinel mice. As both these approaches can miss infections, more sensitive tests are needed, particularly in low-level transmission settings. In this study, loop-mediated isothermal amplification (LAMP) technique, designed to detect a specific 28S ribosomal Schistosoma japonicum (Sj28S) gene with high sensitivity, was compared to microscopy using snail samples from 51 areas endemic for schistosomiasis in five Chinese provinces. In addition, the results were compared with those from polymerase chain reaction (PCR) by adding DNA sequencing as a reference. The testing of pooled snail samples with the LAMP assay showed that a dilution factor of 1/50, i.e., one infected snail plus 49 non-infected ones, would still result in a positive reaction after the recommended number of amplification cycles. Testing a total of 232 pooled samples, emanating from 4006 snail specimens, showed a rate of infection of 6.5%, while traditional microscopy found only 0.4% positive samples in the same materials. Parallel PCR analysis confirmed the diagnostic accuracy of the LAMP assay, with DNA sequencing even giving LAMP a slight lead. Microscopy and the LAMP test were carried out at local schistosomiasis-control stations, demonstrating that the potential of the latter assay to serve as a point-of-care (POC) test with results available within 60–90 min, while the more complicated PCR test had to be carried out at the National Institute of Parasitic Diseases (NIPD) in Shanghai, China. In conclusion, LAMP was found to be clearly superior to microscopy and as good as, or better than, PCR. As it can be used under field conditions and requires less time than other techniques, LAMP testing would improve and accelerate schistosomiasis control.