Ann Franchois
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ann Franchois has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandra Pižurica
Ghent University
1 shared publication Funing Bai
Department of Telecommunications and Information Processing (IPI-TELIN-Iminds) Ghent University B-9000 Ghent Belgium
1 shared publicationJürgen De Zaeytijd
Department of Information Technology (INTEC), Ghent University, Sint-Pietersnieuwstraat 41, 9000 Gent, Belgium
1 shared publication- Luc Taerwe
College of Civil Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China
1 shared publication Peter Lewyllie
Department INTEC-IMEC, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Gent, Belgium. Tel.: +32 9 264 8937; Fax: +32 9 264 3593
1 shared publication
Latest Publications
- Open Access
- 1 January 2016
- Published by The Electromagnetics Academy in Progress In Electromagnetics Research
- Vol. 155, 75-91
3D MICROWAVE TOMOGRAPHY WITH HUBER REGULARIZATION APPLIED TO REALISTIC NUMERICAL BREAST PHANTOMS
Quantitative active microwave imaging for breast cancer screening and therapy monitoring applications requires adequate reconstruction algorithms, in particular with regard to the nonlinearity and ill-posedness of the inverse problem. We employ a fully vectorial three-dimensional nonlinear inversion algorithm for reconstructing complex permittivity profiles from multi-view single-frequency scattered field data, which is based on a Gauss-Newton optimization of a regularized cost function. We tested it before with various types of regularizing functions for piecewise-constant objects from Institut Fresnel and with a quadratic smoothing function for a realistic numerical breast phantom. In the present paper we adopt a cost function that includes a Huber function in its regularization term, relying on a Markov Random Field approach. The Huber function favors spatial smoothing within homogeneous regions while preserving discontinuities between contrasted tissues. We illustrate the technique with 3D reconstructions from synthetic data at 2GHz for realistic numerical breast phantoms from the University of Wisconsin-Madison UWCEM online repository: we compare Huber regularization with a multiplicative smoothing regularization and show reconstructions for various positions of a tumor, for multiple tumors and for different tumor sizes, from a sparse and from a denser data configuration
- 1 January 2016
- Published by The Electromagnetics Academy in Progress In Electromagnetics Research
- Vol. 155, 75-91
Open Access3D MICROWAVE TOMOGRAPHY WITH HUBER REGULARIZATION APPLIED TO REALISTIC NUMERICAL BREAST PHANTOMS
Quantitative active microwave imaging for breast cancer screening and therapy monitoring applications requires adequate reconstruction algorithms, in particular with regard to the nonlinearity and ill-posedness of the inverse problem. We employ a fully vectorial three-dimensional nonlinear inversion algorithm for reconstructing complex permittivity profiles from multi-view single-frequency scattered field data, which is based on a Gauss-Newton optimization of a regularized cost function. We tested it before with various types of regularizing functions for piecewise-constant objects from Institut Fresnel and with a quadratic smoothing function for a realistic numerical breast phantom. In the present paper we adopt a cost function that includes a Huber function in its regularization term, relying on a Markov Random Field approach. The Huber function favors spatial smoothing within homogeneous regions while preserving discontinuities between contrasted tissues. We illustrate the technique with 3D reconstructions from synthetic data at 2GHz for realistic numerical breast phantoms from the University of Wisconsin-Madison UWCEM online repository: we compare Huber regularization with a multiplicative smoothing regularization and show reconstructions for various positions of a tumor, for multiple tumors and for different tumor sizes, from a sparse and from a denser data configuration
- Open Access
- 1 January 2015
- Published by Hindawi Limited in International Journal of Antennas and Propagation
- Vol. 2015, 1-21
A Subspace Preconditioned LSQR Gauss-Newton Method with a Constrained Line Search Path Applied to 3D Biomedical Microwave Imaging
Three contributions that can improve the performance of a Newton-type iterative quantitative microwave imaging algorithm in a biomedical context are proposed. (i) To speed up the iterative forward problem solution, we extrapolate the initial guess of the field from a few field solutions corresponding to previous source positions for the same complex permittivity (i.e., “marching on in source position”) as well as from a Born-type approximation that is computed from a field solution corresponding to one previous complex permittivity profile for the same source position. (ii) The regularized Gauss-Newton update system can be ill-conditioned; hence we propose to employ a two-level preconditioned iterative solution method. We apply the subspace preconditioned LSQR algorithm from Jacobsen et al. (2003) and we employ a 3D cosine basis. (iii) We propose a new constrained line search path in the Gauss-Newton optimization, which incorporates in a smooth manner lower and upper bounds on the object permittivity, such that these bounds never can be violated along the search path. Single-frequency reconstructions from bipolarized synthetic data are shown for various three-dimensional numerical biological phantoms, including a realistic breast phantom from the University of Wisconsin-Madison (UWCEM) online repository.
- 1 January 2015
- Published by Hindawi Limited in International Journal of Antennas and Propagation
- Vol. 2015, 1-21
Open AccessA Subspace Preconditioned LSQR Gauss-Newton Method with a Constrained Line Search Path Applied to 3D Biomedical Microwave Imaging
Three contributions that can improve the performance of a Newton-type iterative quantitative microwave imaging algorithm in a biomedical context are proposed. (i) To speed up the iterative forward problem solution, we extrapolate the initial guess of the field from a few field solutions corresponding to previous source positions for the same complex permittivity (i.e., “marching on in source position”) as well as from a Born-type approximation that is computed from a field solution corresponding to one previous complex permittivity profile for the same source position. (ii) The regularized Gauss-Newton update system can be ill-conditioned; hence we propose to employ a two-level preconditioned iterative solution method. We apply the subspace preconditioned LSQR algorithm from Jacobsen et al. (2003) and we employ a 3D cosine basis. (iii) We propose a new constrained line search path in the Gauss-Newton optimization, which incorporates in a smooth manner lower and upper bounds on the object permittivity, such that these bounds never can be violated along the search path. Single-frequency reconstructions from bipolarized synthetic data are shown for various three-dimensional numerical biological phantoms, including a realistic breast phantom from the University of Wisconsin-Madison (UWCEM) online repository.
- 1 February 2004
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 19 (1-4) , 333-338
2-D near-field SAR non-destructive testing of rebars in a concrete wall
A microwave non-destructive testing technique to localize metal reinforcement bars in a concrete wall is presented. The technique is based on a two-dimensional near-field Synthetic Aperture Radar imaging algorithm in a monostatic stepped frequency arrangement. The resulting, qualitative, images of the induced sources give a clear indication on the position of the highly conductive rebars, thanks to their strongly reflective properties. The algorithm takes into account the presence of the concrete, the complex permittivity of which is assumed to be known. The technique has been succesfully tested on simulated and experimental data for a number of concrete wall samples with various reinforcement configurations.
- 1 February 2004
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 19 (1-4) , 333-338
2-D near-field SAR non-destructive testing of rebars in a concrete wall
A microwave non-destructive testing technique to localize metal reinforcement bars in a concrete wall is presented. The technique is based on a two-dimensional near-field Synthetic Aperture Radar imaging algorithm in a monostatic stepped frequency arrangement. The resulting, qualitative, images of the induced sources give a clear indication on the position of the highly conductive rebars, thanks to their strongly reflective properties. The algorithm takes into account the presence of the concrete, the complex permittivity of which is assumed to be known. The technique has been succesfully tested on simulated and experimental data for a number of concrete wall samples with various reinforcement configurations.