KKKarim El Kholy

Karim El Kholy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Karim El Kholy has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Consensus Report of Group 4 of the 1st Global Consensus for Clinical Guidelines for the Rehabilitation of the Edentulous Maxilla: Conventional Dentures, Implant Overdentures and Implant‐Supported Fixed Dental Prostheses

    by Charlotte Stilwell, Ronald E. Jung, Florian Beuer, Giulia Brunello, Jae‐Kook Cha, Jeanette Chua Keng Ling, Donald A. Curtis, Karim El‐Kholy, Brian Goodacre, Lisa Heitz‐Mayfield, et al.

    Objectives: The 1st Global Consensus for Clinical Guidelines (GCCG) in Implant Dentistry introduced an innovative, evidence‐based, patient‐centred approach to developing practical recommendations for the rehabilitation of the edentulous maxilla. Within this framework, Group 4 focused on formulating clinical recommendations for the planning and delivery of conventional dentures (CD), implant overdentures (IOD) and implant‐supported fixed complete dentures (IFCD) for patients with an edentulous maxilla. Materials and Methods: Group 4 followed the S2k‐level guideline framework of the Association of the Scientific Medical Societies in Germany (AWMF), applying a structured nominal group technique. The evidence base included two systematic reviews synthesising patient‐reported outcomes (PROs) and clinician‐reported outcomes (ClinROs) and their respective measures in patients with an edentulous maxilla. In addition, single‐round international surveys were conducted involving expert clinicians, patients and cross‐disciplinary experts. Draft recommendations were developed during the in‐person consensus meeting in Boston (June 16–18, 2025) and finalised through anonymous plenary voting. Consensus thresholds were predefined at ≥ 75% and ≤ 95% agreement for a consensus and > 95% agreement for a strong consensus. Results: Group 4 participants formulated 14 clinical recommendations covering five stages of treatment: (i) patient selection, (ii) diagnostics, (iii) treatment planning, (iv) treatment procedures and (v) maintenance. During plenary voting, 6 recommendations reached consensus and eight achieved strong consensus. Voting participation per recommendation ranged from 60 to 84 participants (mean 75). Conclusions: Group 4 consensus statements provide structured guidance on the use of removable and fixed implant‐supported dental prostheses for the rehabilitation of the edentulous maxilla. The recommendations reflect current evidence, expert opinion on clinical practice across disciplines and patient perspectives. Key evidence gaps—especially regarding standardised PROMs, long‐term outcomes and maintenance protocols—identify priorities for future clinical research.


    • 1 February 2026
      • Vol. 37 Suppl 3  (Suppl 30) , S81-S107
    Open Access

    Consensus Report of Group 4 of the 1st Global Consensus for Clinical Guidelines for the Rehabilitation of the Edentulous Maxilla: Conventional Dentures, Implant Overdentures and Implant-Supported Fixed Dental Prostheses.

    by Charlotte Stilwell, Ronald E Jung, Florian Beuer, Giulia Brunello, Jae-Kook Cha, Jeanette Chua Keng Ling, Donald A Curtis, Karim El-Kholy, Brian Goodacre, Lisa Heitz-Mayfield, et al.

    The 1st Global Consensus for Clinical Guidelines (GCCG) in Implant Dentistry introduced an innovative, evidence-based, patient-centred approach to developing practical recommendations for the rehabilitation of the edentulous maxilla. Within this framework, Group 4 focused on formulating clinical recommendations for the planning and delivery of conventional dentures (CD), implant overdentures (IOD) and implant-supported fixed complete dentures (IFCD) for patients with an edentulous maxilla. Group 4 followed the S2k-level guideline framework of the Association of the Scientific Medical Societies in Germany (AWMF), applying a structured nominal group technique. The evidence base included two systematic reviews synthesising patient-reported outcomes (PROs) and clinician-reported outcomes (ClinROs) and their respective measures in patients with an edentulous maxilla. In addition, single-round international surveys were conducted involving expert clinicians, patients and cross-disciplinary experts. Draft recommendations were developed during the in-person consensus meeting in Boston (June 16-18, 2025) and finalised through anonymous plenary voting. Consensus thresholds were predefined at ≥ 75% and ≤ 95% agreement for a consensus and > 95% agreement for a strong consensus. Group 4 participants formulated 14 clinical recommendations covering five stages of treatment: (i) patient selection, (ii) diagnostics, (iii) treatment planning, (iv) treatment procedures and (v) maintenance. During plenary voting, 6 recommendations reached consensus and eight achieved strong consensus. Voting participation per recommendation ranged from 60 to 84 participants (mean 75). Group 4 consensus statements provide structured guidance on the use of removable and fixed implant-supported dental prostheses for the rehabilitation of the edentulous maxilla. The recommendations reflect current evidence, expert opinion on clinical practice across disciplines and patient perspectives. Key evidence gaps-especially regarding standardised PROMs, long-term outcomes and maintenance protocols-identify priorities for future clinical research.


  • Open Access

    The Oxidative Response of Human Monocytes to Surface Modified Commercially Pure Titanium

    by Robert P. De Poi, Michael Kowolik, Yoshiki Oshida, Karim El Kholy

    Cellular responses to implanted biomaterials are key to understanding osseointegration. The aim of this investigation was to determine the in vitro priming and activation of the respiratory burst activity of monocytes in response to surface-modified titanium. Human peripheral blood monocytes of healthy blood donors were separated, then incubated with surface-modified grade 2 commercially pure titanium (CPT) disks with a range of known surface energies and surface roughness for 30- or 60-min. Secondary stimulation by phorbol 12-myrisate 13-acetate (PMA) following the priming phase, and luminol-enhanced-chemiluminescence (LCL) was used to monitor oxygen-dependent activity. Comparison among groups was made by incubation time using one-way ANOVA. One sample from each group for each phase of the experiment was viewed under scanning electron microscopy (SEM) and qualitative comparisons made. The results indicate that titanium is capable of priming peripheral blood monocytes following 60-min incubation. In contrast, 30 min incubation time lead to reduced LCL on secondary stimulation as compared to cells alone. At both time intervals, the disk with the lowest surface energy produced significantly less LCL compared to other samples. SEM examination revealed differences in surface morphology at different time points but not between differently surface-modified disks. These results are consistent with the hypothesis that the titanium surface characteristics influenced the monocyte activity, which may be important in regulating the healing response to these materials.


  • Open Access

    Investigating the Response of Human Neutrophils to Hydrophilic and Hydrophobic Micro-Rough Titanium Surfaces

    by Karim El Kholy, Daniel Buser, Julia-Gabriella Wittneben, Dieter D. Bosshardt, Thomas E. Van Dyke, Michael J. Kowolik

    Various treatments have been used to change both the topography and chemistry of titanium surfaces, aiming to enhance tissue response and reduce healing times of endosseous implants. Most studies to date focused on bone healing around dental implants occurring later during the healing cascade. However, the impact of the initial inflammatory response in the surgical wound site on the success and healing time of dental implants is crucial for implant integration and success, yet it is still poorly understood. The purpose of this study was to investigate the effect of titanium surface hydrophilicity on the response of human neutrophils by monitoring oxygen radical production, which was measured as chemiluminescence activity. Materials and Methods: Neutrophils were isolated from human donors’ blood buffy coats using the double sucrose gradient method. Neutrophils were exposed to both hydrophilic and hydrophobic titanium surfaces with identical topographies in the presence and absence of human serum. This resulted in six experimental groups including two different implant surfaces, with and without exposure to human serum, and two control groups including an active control with cells alone and a passive control with no cells. Two samples from each group were fixed and analyzed by SEM. Comparisons between surface treatments for differences in chemiluminescence values were performed using analysis of variance ANOVA. Results and Conclusion: In the absence of exposure to serum, there was no significant difference noted between the reaction of neutrophils to hydrophilic and hydrophobic surfaces. However, there was a significant reduction in the mean and active chemiluminescence activity of neutrophils to serum-coated hydrophilic titanium surfaces than to serum-coated hydrophobic titanium surfaces. This suggests that surface hydrophilicity promotes enhanced adsorption of serum proteins, which leads to decreased provocation of initial immune cells and reduction of local oxygen radical production during wound healing. This can help explain the faster osseointegration demonstrated by hydrophilic titanium implants.


  • Influence of implant macrodesign and insertion connection technology on the accuracy of static computer‐assisted implant surgery

    by Karim El Kholy, Supriya Ebenezer, Julia‐Gabriela Wittneben, Rafael Lazarin, Dominique Rousson, Daniel Buser

    Objective: The aim of this study was to evaluate the effect of three different macrodesigns and two different insertion devices on the accuracy of static computer‐assisted implant surgery (sCAIS).Materials and Methods: Ninety implant replicas with three different macrodesigns: Soft tissue level (TL), bone level (BL), and bone level tapered (BLT) were placed in 30 dental models with two implant insertion devices: Guided adapter and guided screwed‐in mount. Preoperative and postoperative positions of implants were compared and the mean angular deviation, crestal, and apical three‐dimensional (3D) deviation were calculated for each implant macrodesign and each insertion device. Data were analyzed using analysis of variance, post hoc t‐tests and Bonferroni‐Holm's adjustment method. P values less than .05 were considered statistically significant.Results: BLT implants had lower mean 3D deviation values at the crest and the apex when compared with 3D deviations with BL and TL implants (P < .05). Also, BLT implants had lower angular deviations, when compared with BL and TL Implants, however, angular deviations were not statistically significant (P > .05). Considering the insertion device method, no significant differences were noted between insertion devices irrespective of the deviation analyzed.Conclusion: The macrodesign of dental implants may have an influence on the accuracy of sCAIS, with tapered designs offering slightly better positional accuracy than parallel‐walled macrodesigns independent on the method of insertion used.


  • Analysis of trends in implant therapy at a surgical specialty clinic: Patient pool, indications, surgical procedures, and rate of early failures—A 15‐year retrospective analysis

    by Julien Ducommun, Karim El Kholy, Lira Rahman, Martin Schimmel, Viviane Chappuis, Daniel Buser

    Objectives: To evaluate the patient population over a 3‐year period and to compare it to observations of the population at the same clinic over a period of 15 years.Material and Methods: Records of patients receiving dental implants in the Department of Oral Surgery and Stomatology, University of Bern, between January 2014 and December 2016 were analyzed and then compared with data from patients treated between 2002 and 2004 and between 2008 and 2010. Patients were analyzed for demographics and for indications for therapy, as well as for presence or absence and type of complications. Inserted implants were analyzed for type, length, and diameter, as well as for the number and type of associated tissue regeneration procedures.Results: Analysis revealed a continuous linear increase in the average age of patients seeking implant treatment. The most common indication for implant therapy was a single‐tooth gap (STG) (50.5%), followed by distal extension situations (22.3%) and extended edentulous gaps (20.5%). A total of 60.8% of implants placed needed some type of bone augmentation, and 83.5% of implants placed in the anterior maxilla required simultaneous augmentation. Staged guided bone regeneration (GBR) was only necessary in 7% of the cases. Implant failure rates remained low at 0.6%, with postoperative hematomas being the most common postoperative complication (13.4%).Conclusions: The rising demand for dental implants continues as the patient population ages. Single‐tooth gaps remained consistently the most common indication for implant therapy in recent years. Proper case selection and evidence‐based surgical protocols are essential for high success rates.


  • Top Cited Papers

    Influence of surgical guide support and implant site location on accuracy of static Computer‐Assisted Implant Surgery

    by Karim El Kholy, Rafael Lazarin, Simone F. M. Janner, Karin Faerber, Ramona Buser, Daniel Buser

    Objective: To investigate the effect of surgical guide support and implant site location on the accuracy of static Computer‐Assisted Implant Surgery (sCAIS) in partially edentulous patients.Materials and Methods: 375 replica implants were inserted in 85 study models. Surgical implant placement was done using static 3D printed surgical guides, which were designed to be supported either by all the teeth present in the model (full arch), or by 4‐teeth), 3‐teeth or 2‐teeth. Each study model included three single‐tooth gap (STG) situations; one extraction socket site and two implants placed in a distal extension situation. Preplanned and postoperative implant positions were compared using the treatment‐evaluation tool in digital software. 3‐dimensional and angular deviations were measured. Statistical analysis was done using ANOVA, and pairwise t tests and Bonferroni‐Holm's adjustment were applied as a post hoc test.Results: Accuracy of surgical guides used in sCAIS was significantly affected by the number and type of teeth used for its support. Guides supported by 4 teeth were not significantly different from accuracy of full‐arch‐supported guides (p > .05). Guide support by posterior teeth was associated with an increased level of accuracy, when compared to anterior teeth guide support. Implants placed in extraction sockets were associated with significantly higher 3D and angular deviation values (p < .05), and surgical guides with a distal extension situation resulted in significantly higher deviation values (p < .05).Conclusion: The number and location of teeth supporting the surgical guide can significantly influence the accuracy of sCAIS, with 4 teeth providing equal accuracy to full‐arch guides in (STG) situations.


  • The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer‐Assisted Implant Surgery

    by Karim El Kholy, Simone F. M. Janner, Martin Schimmel, Daniel Buser

    Objective: The aim of this study was to evaluate the effect of guided sleeve height, drilling distance, and guided key height on accuracy of static Computer‐Assisted Implant Surgery (sCAIS).Materials and Methods: Pre and post‐operative positions of implants placed in duplicate dental models were compared and recorded after placement of implants according to a standardized treatment planning and execution sCAIS protocol. Guided sleeve heights: 2 mm, 4 mm, 6 mm and guided key heights: 1 mm and 3 mm were equally randomized in six test groups with varying implant lengths (10‐16 mm) and surgical drilling protocols. The mean crestal and apical three‐dimensional (3D) deviation, as well as the angular deviation were calculated for each group. Data was analyzed using multivariate analysis anova. P values less than .05 were considered statistically significant. All P values of post‐hoc tests were corrected for multiple testing using Bonferroni‐Holm's adjustment method.Results: 3D implant positioning accuracy was not significantly affected by the difference in sleeve height alone or by the implant length alone (P > .05). However, 3D and angular deviation values became significantly higher as the total drilling distance below the guided sleeve increased and significantly became lower as the guided key height above the sleeve increased. 18 mm drilling distance resulted in a significantly higher deviation, when compared to 14 mm or 16 mm drilling distances, irrespective of sleeve height or implant length (P < .01). 3 mm key height resulted in significantly less 3D deviation than 1 mm key height (P < .01).Conclusion: Decreasing the drilling distance below the guided sleeve, by using shorter sleeve heights or shorter implants can significantly increase the accuracy of sCAIS.


  • Outcome of early dental implant placement versus other dental implant placement protocols: A systematic review and meta‐analysis

    by Seyed Hossein Bassir, Karim El Kholy, Chia‐Yu Chen, Kyu Ha Lee, Giuseppe Intini

    Background: The aim of this systematic review and meta‐analysis was to compare the clinical efficacy of the early dental implant placement protocol with immediate and delayed dental implant placement protocols.Methods: An electronic and manual search of literature was made to identify clinical studies comparing early implant placement with immediate or delayed placement. Data from the included studies were pooled and quantitative analyses were performed for the implant outcomes reported as the number of failed implants (primary outcome variable) and for changes in peri‐implant marginal bone level, peri‐implant probing depth, and peri‐implant soft tissue level (secondary outcome variables).Results: Twelve studies met the inclusion criteria. Significant difference in risk of implant failure was found neither between the early and immediate placement protocols (risk difference = −0.018; 95% confidence interval [CI] = −0.06, 0.025; P = 0.416) nor between early and delayed placement protocols (risk difference = −0.008; 95% CI = –0.044, 0.028; P = 0.670). Pooled data of changes in peri‐implant marginal bone level demonstrated significantly less marginal bone loss for implants placed using the early placement protocol compared with those placed in fresh extraction sockets (P = 0.001; weighted mean difference = −0.14 mm; 95% CI = −0.22, −0.05). No significant differences were found between the protocols for the other variables.Conclusions: The available evidence supports the clinical efficacy of the early implant placement protocol. Present findings indicate that the early implant placement protocol results in implant outcomes similar to immediate and delayed placement protocols and a superior stability of peri‐implant hard tissue compared with immediate implant placement.