Matthieu Martin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Matthieu Martin has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Tetiana Aksenova
Univ. Grenoble Alpes, CEA, LETI, CLINATEC, F-38000 Grenoble, France
3 shared publications Antoine Souloumiac
Université Paris-Saclay, CEA, List
2 shared publications- Gianluca Vernillo
Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy
2 shared publications - Guillaume Y. Millet
Université Jean Monnet Saint-Etienne, Lyon 1, Université Savoie Mont-Blanc, Laboratoire Interuniversitaire de Biologie de la Motricité, Saint-Etienne, France
2 shared publications - John Temesi
Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, United Kingdom
2 shared publications - Maciej Śliwowski
Univ. Grenoble Alpes, CEA, LETI, Clinatec
2 shared publications
Latest Publications
- 11 March 2023
- Published by Springer Nature
- p. 358-373
Deep Learning for ECoG Brain-Computer Interface: End-to-End vs. Hand-Crafted Features
- 11 March 2023
- Published by Springer Nature
- p. 358-373
Deep Learning for ECoG Brain-Computer Interface: End-to-End vs. Hand-Crafted Features
- 31 March 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026023
Decoding ECoG signal into 3D hand translation using deep learning
Objective. Motor brain-computer interfaces (BCIs) are a promising technology that may enable motor-impaired people to interact with their environment. BCIs would potentially compensate for arm and hand function loss, which is the top priority for individuals with tetraplegia. Designing real-time and accurate BCI is crucial to make such devices useful, safe, and easy to use by patients in a real-life environment. Electrocorticography (ECoG)-based BCIs emerge as a good compromise between invasiveness of the recording device and good spatial and temporal resolution of the recorded signal. However, most ECoG signal decoders used to predict continuous hand movements are linear models. These models have a limited representational capacity and may fail to capture the relationship between ECoG signal features and continuous hand movements. Deep learning (DL) models, which are state-of-the-art in many problems, could be a solution to better capture this relationship. Approach. In this study, we tested several DL-based architectures to predict imagined 3D continuous hand translation using time-frequency features extracted from ECoG signals. The dataset used in the analysis is a part of a long-term clinical trial (ClinicalTrials.gov identifier: NCT02550522) and was acquired during a closed-loop experiment with a tetraplegic subject. The proposed architectures include multilayer perceptron, convolutional neural networks (CNNs), and long short-term memory networks (LSTM). The accuracy of the DL-based and multilinear models was compared offline using cosine similarity. Main results. Our results show that CNN-based architectures outperform the current state-of-the-art multilinear model. The best architecture exploited the spatial correlation between neighboring electrodes with CNN and benefited from the sequential character of the desired hand trajectory by using LSTMs. Overall, DL increased the average cosine similarity, compared to the multilinear model, by up to 60%, from 0.189 to 0.302 and from 0.157 to 0.249 for the left and right hand, respectively. Significance. This study shows that DL-based models could increase the accuracy of BCI systems in the case of 3D hand translation prediction in a tetraplegic subject.
- 31 March 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026023
Decoding ECoG signal into 3D hand translation using deep learning
Objective. Motor brain-computer interfaces (BCIs) are a promising technology that may enable motor-impaired people to interact with their environment. BCIs would potentially compensate for arm and hand function loss, which is the top priority for individuals with tetraplegia. Designing real-time and accurate BCI is crucial to make such devices useful, safe, and easy to use by patients in a real-life environment. Electrocorticography (ECoG)-based BCIs emerge as a good compromise between invasiveness of the recording device and good spatial and temporal resolution of the recorded signal. However, most ECoG signal decoders used to predict continuous hand movements are linear models. These models have a limited representational capacity and may fail to capture the relationship between ECoG signal features and continuous hand movements. Deep learning (DL) models, which are state-of-the-art in many problems, could be a solution to better capture this relationship. Approach. In this study, we tested several DL-based architectures to predict imagined 3D continuous hand translation using time-frequency features extracted from ECoG signals. The dataset used in the analysis is a part of a long-term clinical trial (ClinicalTrials.gov identifier: NCT02550522) and was acquired during a closed-loop experiment with a tetraplegic subject. The proposed architectures include multilayer perceptron, convolutional neural networks (CNNs), and long short-term memory networks (LSTM). The accuracy of the DL-based and multilinear models was compared offline using cosine similarity. Main results. Our results show that CNN-based architectures outperform the current state-of-the-art multilinear model. The best architecture exploited the spatial correlation between neighboring electrodes with CNN and benefited from the sequential character of the desired hand trajectory by using LSTMs. Overall, DL increased the average cosine similarity, compared to the multilinear model, by up to 60%, from 0.189 to 0.302 and from 0.157 to 0.249 for the left and right hand, respectively. Significance. This study shows that DL-based models could increase the accuracy of BCI systems in the case of 3D hand translation prediction in a tetraplegic subject.
- Open Access
- 30 March 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026021
An adaptive closed-loop ECoG decoder for long-term and stable bimanual control of an exoskeleton by a tetraplegic
Objective. The article aims at addressing 2 challenges to step motor brain-computer interface (BCI) out of laboratories: asynchronous control of complex bimanual effectors with large numbers of degrees of freedom, using chronic and safe recorders, and the decoding performance stability over time without frequent decoder recalibration. Approach. Closed-loop adaptive/incremental decoder training is one strategy to create a model stable over time. Adaptive decoders update their parameters with new incoming data, optimizing the model parameters in real time. It allows cross-session training with multiple recording conditions during closed loop BCI experiments. In the article, an adaptive tensor-based recursive exponentially weighted Markov-switching multi-linear model (REW-MSLM) decoder is proposed. REW-MSLM uses a mixture of expert (ME) architecture, mixing or switching independent decoders (experts) according to the probability estimated by a ‘gating’ model. A Hidden Markov model approach is employed as gating model to improve the decoding robustness and to provide strong idle state support. The ME architecture fits the multi-limb paradigm associating an expert to a particular limb or action. Main results. Asynchronous control of an exoskeleton by a tetraplegic patient using a chronically implanted epidural electrocorticography (EpiCoG) recorder is reported. The stable over a period of six months (without decoder recalibration) eight-dimensional alternative bimanual control of the exoskeleton and its virtual avatar is demonstrated. Significance. Based on the long-term (>36 months) chronic bilateral EpiCoG recordings in a tetraplegic (ClinicalTrials.gov, NCT02550522), we addressed the poorly explored field of asynchronous bimanual BCI. The new decoder was designed to meet to several challenges: the high-dimensional control of a complex effector in experiments closer to real-world behavior (point-to-point pursuit versus conventional center-out tasks), with the ability of the BCI system to act as a stand-alone device switching between idle and control states, and a stable performance over a long period of time without decoder recalibration.
- 30 March 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026021
Open AccessAn adaptive closed-loop ECoG decoder for long-term and stable bimanual control of an exoskeleton by a tetraplegic
Objective. The article aims at addressing 2 challenges to step motor brain-computer interface (BCI) out of laboratories: asynchronous control of complex bimanual effectors with large numbers of degrees of freedom, using chronic and safe recorders, and the decoding performance stability over time without frequent decoder recalibration. Approach. Closed-loop adaptive/incremental decoder training is one strategy to create a model stable over time. Adaptive decoders update their parameters with new incoming data, optimizing the model parameters in real time. It allows cross-session training with multiple recording conditions during closed loop BCI experiments. In the article, an adaptive tensor-based recursive exponentially weighted Markov-switching multi-linear model (REW-MSLM) decoder is proposed. REW-MSLM uses a mixture of expert (ME) architecture, mixing or switching independent decoders (experts) according to the probability estimated by a ‘gating’ model. A Hidden Markov model approach is employed as gating model to improve the decoding robustness and to provide strong idle state support. The ME architecture fits the multi-limb paradigm associating an expert to a particular limb or action. Main results. Asynchronous control of an exoskeleton by a tetraplegic patient using a chronically implanted epidural electrocorticography (EpiCoG) recorder is reported. The stable over a period of six months (without decoder recalibration) eight-dimensional alternative bimanual control of the exoskeleton and its virtual avatar is demonstrated. Significance. Based on the long-term (>36 months) chronic bilateral EpiCoG recordings in a tetraplegic (ClinicalTrials.gov, NCT02550522), we addressed the poorly explored field of asynchronous bimanual BCI. The new decoder was designed to meet to several challenges: the high-dimensional control of a complex effector in experiments closer to real-world behavior (point-to-point pursuit versus conventional center-out tasks), with the ability of the BCI system to act as a stand-alone device switching between idle and control states, and a stable performance over a long period of time without decoder recalibration.
- 1 April 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 131, 104268
Automatic segmentation and location learning of neonatal cerebral ventricles in 3D ultrasound data combining CNN and CPPN
- 1 April 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 131, 104268
Automatic segmentation and location learning of neonatal cerebral ventricles in 3D ultrasound data combining CNN and CPPN
- Open Access
Automatic Segmentation and Location Learning of Neonatal Cerebral Ventricles in 3D Ultrasound Data Combining CNN and CPPN
Preterm neonates are highly likely to suffer from ventriculomegaly, a dilation of the Cerebral Ventricular System (CVS). This condition can develop into life-threatening hydrocephalus and is correlated with future neuro-developmental impairments. Consequently, it must be detected and monitored by physicians. In clinical routing, manual 2D measurements are performed on 2D ultrasound (US) images to estimate the CVS volume but this practice is imprecise due to the unavailability of 3D information. A way to tackle this problem would be to develop automatic CVS segmentation algorithms for 3D US data. In this paper, we investigate the potential of 2D and 3D Convolutional Neural Networks (CNN) to solve this complex task and propose to use Compositional Pattern Producing Network (CPPN) to enable the CNNs to learn CVS location. Our database was composed of 25 3D US volumes collected on 21 preterm nenonates at the age of $35.8 \pm 1.6$ gestational weeks. We found that the CPPN enables to encode CVS location, which increases the accuracy of the CNNs when they have few layers. Accuracy of the 2D and 3D CNNs reached intraobserver variability (IOV) in the case of dilated ventricles with Dice of $0.893 \pm 0.008$ and $0.886 \pm 0.004$ respectively (IOV = $0.898 \pm 0.008$) and with volume errors of $0.45 \pm 0.42$ cm$^3$ and $0.36 \pm 0.24$ cm$^3$ respectively (IOV = $0.41 \pm 0.05$ cm$^3$). 3D CNNs were more accurate than 2D CNNs in the case of normal ventricles with Dice of $0.797 \pm 0.041$ against $0.776 \pm 0.038$ (IOV = $0.816 \pm 0.009$) and volume errors of $0.35 \pm 0.29$ cm$^3$ against $0.35 \pm 0.24$ cm$^3$ (IOV = $0.2 \pm 0.11$ cm$^3$). The best segmentation time of volumes of size $320 \times 320 \times 320$ was obtained by a 2D CNN in $3.5 \pm 0.2$ s.Open AccessAutomatic Segmentation and Location Learning of Neonatal Cerebral Ventricles in 3D Ultrasound Data Combining CNN and CPPN
Preterm neonates are highly likely to suffer from ventriculomegaly, a dilation of the Cerebral Ventricular System (CVS). This condition can develop into life-threatening hydrocephalus and is correlated with future neuro-developmental impairments. Consequently, it must be detected and monitored by physicians. In clinical routing, manual 2D measurements are performed on 2D ultrasound (US) images to estimate the CVS volume but this practice is imprecise due to the unavailability of 3D information. A way to tackle this problem would be to develop automatic CVS segmentation algorithms for 3D US data. In this paper, we investigate the potential of 2D and 3D Convolutional Neural Networks (CNN) to solve this complex task and propose to use Compositional Pattern Producing Network (CPPN) to enable the CNNs to learn CVS location. Our database was composed of 25 3D US volumes collected on 21 preterm nenonates at the age of $35.8 \pm 1.6$ gestational weeks. We found that the CPPN enables to encode CVS location, which increases the accuracy of the CNNs when they have few layers. Accuracy of the 2D and 3D CNNs reached intraobserver variability (IOV) in the case of dilated ventricles with Dice of $0.893 \pm 0.008$ and $0.886 \pm 0.004$ respectively (IOV = $0.898 \pm 0.008$) and with volume errors of $0.45 \pm 0.42$ cm$^3$ and $0.36 \pm 0.24$ cm$^3$ respectively (IOV = $0.41 \pm 0.05$ cm$^3$). 3D CNNs were more accurate than 2D CNNs in the case of normal ventricles with Dice of $0.797 \pm 0.041$ against $0.776 \pm 0.038$ (IOV = $0.816 \pm 0.009$) and volume errors of $0.35 \pm 0.29$ cm$^3$ against $0.35 \pm 0.24$ cm$^3$ (IOV = $0.2 \pm 0.11$ cm$^3$). The best segmentation time of volumes of size $320 \times 320 \times 320$ was obtained by a 2D CNN in $3.5 \pm 0.2$ s. - 1 September 2020
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 124 (3) , 763-773
Spinal contribution to neuromuscular recovery differs between elbow-flexor and knee-extensor muscles after a maximal sustained fatiguing task
Data from studies of elbow-flexor (EF) or knee-extensor (KE) muscles suggest that a fatigue-related decrease in motoneuron excitability only occurs in EF. It is unknown how motoneuron excitability changes after sustained fatiguing maximal voluntary isometric contractions (MVICs) in EF and KE in the same participants. In two sessions, eight healthy men performed a 2-min MVIC of EF or KE to induce fatigue with brief MVICs before and six times after the 2-min MVIC. Electromyographic responses elicited by corticospinal tract stimulation at the transmastoid [cervicomedullary motor-evoked potential (CMEP)] or thoracic [thoracic motor-evoked potential (TMEP)] level were recorded from EF and KE, respectively. To account for muscle excitability, CMEPs and TMEPs were normalized to maximal M-wave (Mmax) elicited by peripheral nerve stimulation during each brief MVIC. Immediately after the 2-min MVIC, biceps brachii and brachioradialis CMEP/Mmax were 88% (SD 11%) (P = 0.026) and 87% (SD 12%) (P = 0.029) of pre-MVIC values, respectively, and remained lower than PRE after 5 s of recovery [91% (SD 8%), P = 0.036 and 87% (SD 13%), P = 0.046, respectively]. No subsequent time points differed from PRE (all P ³ 0.253). TMEP/Mmax for rectus femoris and vastus lateralis were not different from PRE at any time during the recovery period (all P > 0.050). A different recovery pattern in motoneuron excitability occurred in EF as it recovered by 60 s whereas KE motoneurons were unaffected by the fatiguing task. The present findings may contribute to better understand muscle-specific neurophysiological differences in spinal excitability.
- 1 September 2020
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 124 (3) , 763-773
Spinal contribution to neuromuscular recovery differs between elbow-flexor and knee-extensor muscles after a maximal sustained fatiguing task
Data from studies of elbow-flexor (EF) or knee-extensor (KE) muscles suggest that a fatigue-related decrease in motoneuron excitability only occurs in EF. It is unknown how motoneuron excitability changes after sustained fatiguing maximal voluntary isometric contractions (MVICs) in EF and KE in the same participants. In two sessions, eight healthy men performed a 2-min MVIC of EF or KE to induce fatigue with brief MVICs before and six times after the 2-min MVIC. Electromyographic responses elicited by corticospinal tract stimulation at the transmastoid [cervicomedullary motor-evoked potential (CMEP)] or thoracic [thoracic motor-evoked potential (TMEP)] level were recorded from EF and KE, respectively. To account for muscle excitability, CMEPs and TMEPs were normalized to maximal M-wave (Mmax) elicited by peripheral nerve stimulation during each brief MVIC. Immediately after the 2-min MVIC, biceps brachii and brachioradialis CMEP/Mmax were 88% (SD 11%) (P = 0.026) and 87% (SD 12%) (P = 0.029) of pre-MVIC values, respectively, and remained lower than PRE after 5 s of recovery [91% (SD 8%), P = 0.036 and 87% (SD 13%), P = 0.046, respectively]. No subsequent time points differed from PRE (all P ³ 0.253). TMEP/Mmax for rectus femoris and vastus lateralis were not different from PRE at any time during the recovery period (all P > 0.050). A different recovery pattern in motoneuron excitability occurred in EF as it recovered by 60 s whereas KE motoneurons were unaffected by the fatiguing task. The present findings may contribute to better understand muscle-specific neurophysiological differences in spinal excitability.
- 1 October 2018
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 22 (6-7) , 707
Réirradiation des rechutes de gliomes de haut grade après un premier radiothérapie et témozolomide
- 1 October 2018
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 22 (6-7) , 707
Réirradiation des rechutes de gliomes de haut grade après un premier radiothérapie et témozolomide
- 3 August 2018
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 37 (4) , 387-395
Do aerobic characteristics explain isometric exercise-induced neuromuscular fatigue and recovery in upper and lower limbs?
This study investigated the relationships between aerobic characteristics and (i) neuromuscular fatigue induced by 2-min sustained isometric maximal voluntary contractions (MVC) and (ii) subsequent recovery, in the upper and lower limbs. In a pseudo-randomized order, eleven healthy males completed four sessions on different days: maximal incremental cycling test (100 W + 40 W every 2 min); maximal arm-cranking test (50 W + 20 W every 2 min); and 2-min sustained isometric MVCs of the knee extensors (KE) and elbow flexors (EF). Neuromuscular assessment was performed with transcranial magnetic and peripheral nerve stimulation to evaluate central and peripheral neuromuscular factors of fatigue and the subsequent recovery. Peak oxygen uptake, gas exchange threshold and the corresponding power outputs were correlated with recovery of voluntary force after the 2-min KE MVC. Regression analysis showed that power output at the gas exchange threshold alone explained 72% of the variability in ∆recovery of KE voluntary force. No relationships with fatigue or recovery in EF were observed. These results suggest that participants with greater aerobic capacities experience the same amount of fatigue and faster recovery of voluntary force in KE but not EF. The potential reasons behind the relationship in KE but not EF are discussed.
- 3 August 2018
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 37 (4) , 387-395
Do aerobic characteristics explain isometric exercise-induced neuromuscular fatigue and recovery in upper and lower limbs?
This study investigated the relationships between aerobic characteristics and (i) neuromuscular fatigue induced by 2-min sustained isometric maximal voluntary contractions (MVC) and (ii) subsequent recovery, in the upper and lower limbs. In a pseudo-randomized order, eleven healthy males completed four sessions on different days: maximal incremental cycling test (100 W + 40 W every 2 min); maximal arm-cranking test (50 W + 20 W every 2 min); and 2-min sustained isometric MVCs of the knee extensors (KE) and elbow flexors (EF). Neuromuscular assessment was performed with transcranial magnetic and peripheral nerve stimulation to evaluate central and peripheral neuromuscular factors of fatigue and the subsequent recovery. Peak oxygen uptake, gas exchange threshold and the corresponding power outputs were correlated with recovery of voluntary force after the 2-min KE MVC. Regression analysis showed that power output at the gas exchange threshold alone explained 72% of the variability in ∆recovery of KE voluntary force. No relationships with fatigue or recovery in EF were observed. These results suggest that participants with greater aerobic capacities experience the same amount of fatigue and faster recovery of voluntary force in KE but not EF. The potential reasons behind the relationship in KE but not EF are discussed.