Steven Dymarkowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Steven Dymarkowski has a total of 140 co-authors. Here are the top co-authors by number of shared publications:
- Frederik De Keyzer
Department of Radiology, University Hospitals Leuven, Leuven, Belgium
6 shared publications - Hein Heidbuchel
Research Group Cardiovascular Diseases, GENCOR, University of Antwerp, Antwerp, Belgium
4 shared publications J. Deprest
University Hospital Gasthuisberg, Leuven, Belgium
4 shared publicationsJ. Jani
University Hospital Gasthuisberg, Leuven, Belgium
4 shared publications- Jan Bogaert
Unité Biodiversité Et Paysage, Gembloux Agro-Bio Tech, Université de Liège, Liège, Belgium
4 shared publications M. Cannie
University Hospital Gasthuisberg, Leuven, Belgium
4 shared publications
Latest Publications
- Open Access
- 7 April 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 153 (14) , 1009-1022
Wearable-Derived Training Load and Coronary Atherosclerosis in Middle-Aged and Older Athletes and Physically Active Controls: A New Perspective From the Master@Heart Study
BACKGROUND: Middle-aged and older endurance athletes have increased prevalence of coronary artery disease (CAD) on coronary computed tomography angiography compared with healthy controls, despite similarly low cardiovascular risk. Previous studies relied on self-reported data to quantify training load (TL), which poorly correlates with objective wearable-derived TL and may bias outcomes. The effect of objective TL on CAD risk remains unknown. METHODS: In this observational, cross-sectional analysis of the Master@Heart study, 222 men (median age, 54 [49–59] years) were included: 77 lifelong athletes, 98 late-onset athletes, and 47 controls. TL was assessed using objective wearable-derived training duration and intensity (12 consecutive months), as well as self-reported training measures. Coronary computed tomography angiography–derived CAD prevalence was compared across TL quartiles (Q) using a global unadjusted chi-square test and logistic regression, adjusted for cardiovascular risk factors and years of endurance exercise, to estimate odds ratios between Q4 and Q1. In addition, adjusted logistic regression models were fitted with continuous TL, using smoothing splines to capture potential nonlinear associations. RESULTS: Across quartiles of objective Edwards training impulse (training duration × heart rate–weighted intensity), unadjusted global differences were observed for ≥1 plaque ( P 0 ( P =0.002), and CAC>100 ( P =0.012). Q4 participants had significantly higher adjusted odds of ≥1 plaque (odds ratio, 5.85; 95% CI, 2.33–14.71), CAC>0 (odds ratio, 5.03; 95% CI, 2.04–12.35), and CAC>100 (odds ratio, 3.50; 95% CI, 1.22–10.00) versus Q1. Similar associations were found for objective training duration, whereas no clear associations were observed for relative time spent in high-intensity zones. In continuous analyses, Edwards training impulse and objective training duration showed significant positive associations with ≥1 plaque and CAC>100 ( P 100 ( P 0.05). CONCLUSIONS: High training duration (hours/week), particularly when combined with cumulative high-intensity TL (Edwards training impulse), was independently associated with increased prevalence of subclinical CAD in middle-aged and older athletes and physically active controls. Exercise intensity alone, in the absence of high duration, was not clearly linked to CAD. These findings underscore the potential of objectively measured TL for understanding associations with subclinical CAD in endurance athletes. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03711539.
- 7 April 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 153 (14) , 1009-1022
Open AccessWearable-Derived Training Load and Coronary Atherosclerosis in Middle-Aged and Older Athletes and Physically Active Controls: A New Perspective From the Master@Heart Study
BACKGROUND: Middle-aged and older endurance athletes have increased prevalence of coronary artery disease (CAD) on coronary computed tomography angiography compared with healthy controls, despite similarly low cardiovascular risk. Previous studies relied on self-reported data to quantify training load (TL), which poorly correlates with objective wearable-derived TL and may bias outcomes. The effect of objective TL on CAD risk remains unknown. METHODS: In this observational, cross-sectional analysis of the Master@Heart study, 222 men (median age, 54 [49–59] years) were included: 77 lifelong athletes, 98 late-onset athletes, and 47 controls. TL was assessed using objective wearable-derived training duration and intensity (12 consecutive months), as well as self-reported training measures. Coronary computed tomography angiography–derived CAD prevalence was compared across TL quartiles (Q) using a global unadjusted chi-square test and logistic regression, adjusted for cardiovascular risk factors and years of endurance exercise, to estimate odds ratios between Q4 and Q1. In addition, adjusted logistic regression models were fitted with continuous TL, using smoothing splines to capture potential nonlinear associations. RESULTS: Across quartiles of objective Edwards training impulse (training duration × heart rate–weighted intensity), unadjusted global differences were observed for ≥1 plaque ( P 0 ( P =0.002), and CAC>100 ( P =0.012). Q4 participants had significantly higher adjusted odds of ≥1 plaque (odds ratio, 5.85; 95% CI, 2.33–14.71), CAC>0 (odds ratio, 5.03; 95% CI, 2.04–12.35), and CAC>100 (odds ratio, 3.50; 95% CI, 1.22–10.00) versus Q1. Similar associations were found for objective training duration, whereas no clear associations were observed for relative time spent in high-intensity zones. In continuous analyses, Edwards training impulse and objective training duration showed significant positive associations with ≥1 plaque and CAC>100 ( P 100 ( P 0.05). CONCLUSIONS: High training duration (hours/week), particularly when combined with cumulative high-intensity TL (Edwards training impulse), was independently associated with increased prevalence of subclinical CAD in middle-aged and older athletes and physically active controls. Exercise intensity alone, in the absence of high duration, was not clearly linked to CAD. These findings underscore the potential of objectively measured TL for understanding associations with subclinical CAD in endurance athletes. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03711539.
- 8 October 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (06) , 1-13
Augmented and virtual reality imaging for collaborative planning of structural cardiovascular interventions: a proof-of-concept and validation study
PurposeVirtual reality (VR) and augmented reality (AR) have led to significant advancements in cardiac preoperative planning, shaping the world in profound ways. A noticeable gap exists in the availability of a comprehensive multi-user, multi-device mixed reality application that can be used in a multidisciplinary team meeting.ApproachA multi-user, multi-device mixed reality application was developed, supporting AR and VR implementations. Technical validation involved a standardized testing protocol and comparison of AR and VR measurements regarding absolute error and time. Preclinical validation engaged experts in interventional cardiology, evaluating the clinical applicability prior to clinical validation. Clinical validation included patient-specific measurements for five patients in VR compared with standard computed tomography (CT) for preoperative planning. Questionnaires were used at all stages for subjective evaluation.ResultsTechnical validation, including 106 size measurements, demonstrated an absolute median error of 0.69 mm (0.25 to 1.18 mm) compared with ground truth. The time to complete the entire task was 892±407 s on average, with VR measurements being faster than AR (804±483 versus 957±257 s, P=0.045). On clinical validation of five preoperative patients, there was no statistically significant difference between paired CT and VR measurements (0.58 [95% CI, −1.58 to 2.74], P=0.586). Questionnaires showcased unanimous agreement on the user-friendly nature, effectiveness, and clinical value.ConclusionsThe mixed reality application, validated through technical, preclinical, and clinical assessments, demonstrates precision and user-friendliness. Further research of our application is needed to validate the generalizability and impact on patient outcomes.
- 8 October 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (06) , 1-13
Augmented and virtual reality imaging for collaborative planning of structural cardiovascular interventions: a proof-of-concept and validation study
PurposeVirtual reality (VR) and augmented reality (AR) have led to significant advancements in cardiac preoperative planning, shaping the world in profound ways. A noticeable gap exists in the availability of a comprehensive multi-user, multi-device mixed reality application that can be used in a multidisciplinary team meeting.ApproachA multi-user, multi-device mixed reality application was developed, supporting AR and VR implementations. Technical validation involved a standardized testing protocol and comparison of AR and VR measurements regarding absolute error and time. Preclinical validation engaged experts in interventional cardiology, evaluating the clinical applicability prior to clinical validation. Clinical validation included patient-specific measurements for five patients in VR compared with standard computed tomography (CT) for preoperative planning. Questionnaires were used at all stages for subjective evaluation.ResultsTechnical validation, including 106 size measurements, demonstrated an absolute median error of 0.69 mm (0.25 to 1.18 mm) compared with ground truth. The time to complete the entire task was 892±407 s on average, with VR measurements being faster than AR (804±483 versus 957±257 s, P=0.045). On clinical validation of five preoperative patients, there was no statistically significant difference between paired CT and VR measurements (0.58 [95% CI, −1.58 to 2.74], P=0.586). Questionnaires showcased unanimous agreement on the user-friendly nature, effectiveness, and clinical value.ConclusionsThe mixed reality application, validated through technical, preclinical, and clinical assessments, demonstrates precision and user-friendliness. Further research of our application is needed to validate the generalizability and impact on patient outcomes.
- Open Access
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 31
Epstein–Barr Virus-Associated Atraumatic Splenic Rupture
Teaching point: Atraumatic splenic rupture is a rare but life-threatening complication of infectious mononucleosis.
- 1 January 2024
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 108 (1) , 31
Open AccessEpstein–Barr Virus-Associated Atraumatic Splenic Rupture
Teaching point: Atraumatic splenic rupture is a rare but life-threatening complication of infectious mononucleosis.
- Open Access
- 2 March 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (4) , 486-491
Application of Automatic Segmentation on Super-Resolution Reconstruction MR Images of the Abnormal Fetal Brain
BACKGROUND AND PURPOSE: Fetal brain MR imaging is clinically used to characterize fetal brain abnormalities. Recently, algorithms have been proposed to reconstruct high-resolution 3D fetal brain volumes from 2D slices. By means of these reconstructions, convolutional neural networks have been developed for automatic image segmentation to avoid labor-intensive manual annotations, usually trained on data of normal fetal brains. Herein, we tested the performance of an algorithm specifically developed for segmentation of abnormal fetal brains. MATERIALS AND METHODS: This was a single-center retrospective study on MR images of 16 fetuses with severe CNS anomalies (gestation, 21–39 weeks). T2-weighted 2D slices were converted to 3D volumes using a super-resolution reconstruction algorithm. The acquired volumetric data were then processed by a novel convolutional neural network to perform segmentations of white matter and the ventricular system and cerebellum. These were compared with manual segmentation using the Dice coefficient, Hausdorff distance (95th percentile), and volume difference. Using interquartile ranges, we identified outliers of these metrics and further analyzed them in detail. RESULTS: The mean Dice coefficient was 96.2%, 93.7%, and 94.7% for white matter and the ventricular system and cerebellum, respectively. The Hausdorff distance was 1.1, 2.3, and 1.6 mm, respectively. The volume difference was 1.6, 1.4, and 0.3 mL, respectively. Of the 126 measurements, there were 16 outliers among 5 fetuses, discussed on a case-by-case basis. CONCLUSIONS: Our novel segmentation algorithm obtained excellent results on MR images of fetuses with severe brain abnormalities. Analysis of the outliers shows the need to include pathologies underrepresented in the current data set. Quality control to prevent occasional errors is still needed.
- 2 March 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (4) , 486-491
Open AccessApplication of Automatic Segmentation on Super-Resolution Reconstruction MR Images of the Abnormal Fetal Brain
BACKGROUND AND PURPOSE: Fetal brain MR imaging is clinically used to characterize fetal brain abnormalities. Recently, algorithms have been proposed to reconstruct high-resolution 3D fetal brain volumes from 2D slices. By means of these reconstructions, convolutional neural networks have been developed for automatic image segmentation to avoid labor-intensive manual annotations, usually trained on data of normal fetal brains. Herein, we tested the performance of an algorithm specifically developed for segmentation of abnormal fetal brains. MATERIALS AND METHODS: This was a single-center retrospective study on MR images of 16 fetuses with severe CNS anomalies (gestation, 21–39 weeks). T2-weighted 2D slices were converted to 3D volumes using a super-resolution reconstruction algorithm. The acquired volumetric data were then processed by a novel convolutional neural network to perform segmentations of white matter and the ventricular system and cerebellum. These were compared with manual segmentation using the Dice coefficient, Hausdorff distance (95th percentile), and volume difference. Using interquartile ranges, we identified outliers of these metrics and further analyzed them in detail. RESULTS: The mean Dice coefficient was 96.2%, 93.7%, and 94.7% for white matter and the ventricular system and cerebellum, respectively. The Hausdorff distance was 1.1, 2.3, and 1.6 mm, respectively. The volume difference was 1.6, 1.4, and 0.3 mL, respectively. Of the 126 measurements, there were 16 outliers among 5 fetuses, discussed on a case-by-case basis. CONCLUSIONS: Our novel segmentation algorithm obtained excellent results on MR images of fetuses with severe brain abnormalities. Analysis of the outliers shows the need to include pathologies underrepresented in the current data set. Quality control to prevent occasional errors is still needed.
- 6 February 2022
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 198 (3) , 139-146
PURSUING OPTIMAL RADIATION DOSE IN PEDIATRIC CARDIAC CT: A REPORT FROM UNIVERSITY HOSPITAL LEUVEN
Background: Computed tomography (CT) balances between high resolution and low radiation dose. Given the greater radiosensitivity of children, it is appropriate to use child-friendly CT-protocols that reduce radiation dose at acceptable image quality. This article states the radiation dose in pediatric cardiac CT-examinations at university hospital Leuven (Belgium) and compares with findings published by similar medical centers. The diagnostic accuracy was simultaneously compared, as it correlates with radiation dose. Material and methods: his retrospective observational study analyzed 58 CT-scans of 52 patients. The radiation dose was calculated in effective dose. The image quality was scored qualitatively with a 5-point scale. The diagnostic accuracy, a derivative representation of the image quality, was checked with findings from surgery or conventional angiography. Results: The mean effective dose in our study population was 1.3 ± 0.4 mSv. The qualitative image quality was on average ‘good’, elaborated with a score of 4.0 ± 0.2. The diagnostic accuracy was 92%. Comparative literature study provides a mean effective dose of 1.5 mSv and the reported diagnostic accuracy from other centers reaches ≥90%. Conclusions: At our center pediatric cardiac CT-scans are obtained with good-to-excellent image quality and high diagnostic accuracy at low radiation doses. These results meet the radiation dose and diagnostic accuracy as published by comparable medical centers.
- 6 February 2022
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 198 (3) , 139-146
PURSUING OPTIMAL RADIATION DOSE IN PEDIATRIC CARDIAC CT: A REPORT FROM UNIVERSITY HOSPITAL LEUVEN
Background: Computed tomography (CT) balances between high resolution and low radiation dose. Given the greater radiosensitivity of children, it is appropriate to use child-friendly CT-protocols that reduce radiation dose at acceptable image quality. This article states the radiation dose in pediatric cardiac CT-examinations at university hospital Leuven (Belgium) and compares with findings published by similar medical centers. The diagnostic accuracy was simultaneously compared, as it correlates with radiation dose. Material and methods: his retrospective observational study analyzed 58 CT-scans of 52 patients. The radiation dose was calculated in effective dose. The image quality was scored qualitatively with a 5-point scale. The diagnostic accuracy, a derivative representation of the image quality, was checked with findings from surgery or conventional angiography. Results: The mean effective dose in our study population was 1.3 ± 0.4 mSv. The qualitative image quality was on average ‘good’, elaborated with a score of 4.0 ± 0.2. The diagnostic accuracy was 92%. Comparative literature study provides a mean effective dose of 1.5 mSv and the reported diagnostic accuracy from other centers reaches ≥90%. Conclusions: At our center pediatric cardiac CT-scans are obtained with good-to-excellent image quality and high diagnostic accuracy at low radiation doses. These results meet the radiation dose and diagnostic accuracy as published by comparable medical centers.
- 16 October 2019
- Published by Wiley in Prenatal Diagnosis
- Vol. 40 (1) , 6-17
Fetal MRI for dummies: what the fetal medicine specialist should know about acquisitions and sequences
Fetal MRI is an increasingly used tool in the field of prenatal diagnosis. While US remains the first line screening tool, as an adjuvant imaging tool, MRI has been proven to increase diagnostic accuracy and change patient counseling. Further, there are instances when US may not be sufficient for diagnosis. As a multidisciplinary field, it is important that every person involved in the referral, diagnosis, counseling and treatment of the patients is familiar with the basic principles, indications and findings of fetal MRI. The purpose of the current paper is to equip radiologists and non‐radiologists with basic MRI principles and essential topics in patient preparation and provide illustrative examples of when fetal MRI may be used. This aims to aid the referring clinician in better selecting and improve patient counseling prior to arrival in the radiology department and, ultimately, patient care.
- 16 October 2019
- Published by Wiley in Prenatal Diagnosis
- Vol. 40 (1) , 6-17
Fetal MRI for dummies: what the fetal medicine specialist should know about acquisitions and sequences
Fetal MRI is an increasingly used tool in the field of prenatal diagnosis. While US remains the first line screening tool, as an adjuvant imaging tool, MRI has been proven to increase diagnostic accuracy and change patient counseling. Further, there are instances when US may not be sufficient for diagnosis. As a multidisciplinary field, it is important that every person involved in the referral, diagnosis, counseling and treatment of the patients is familiar with the basic principles, indications and findings of fetal MRI. The purpose of the current paper is to equip radiologists and non‐radiologists with basic MRI principles and essential topics in patient preparation and provide illustrative examples of when fetal MRI may be used. This aims to aid the referring clinician in better selecting and improve patient counseling prior to arrival in the radiology department and, ultimately, patient care.
- Open Access
- 27 December 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (1) , 191-198
Reliability of MR Imaging–Based Posterior Fossa and Brain Stem Measurements in Open Spinal Dysraphism in the Era of Fetal Surgery
BACKGROUND AND PURPOSE: Fetal MR imaging is part of the comprehensive prenatal assessment of fetuses with open spinal dysraphism. We aimed to assess the reliability of brain stem and posterior fossa measurements; use the reliable measurements to characterize fetuses with open spinal dysraphism versus what can be observed in healthy age-matched controls; and document changes in those within 1 week after prenatal repair. MATERIALS AND METHODS: Retrospective evaluation of 349 MR imaging examinations took place, including 274 in controls and 52 in fetuses with open spinal dysraphism, of whom 23 underwent prenatal repair and had additional early postoperative MR images. We evaluated measurements of the brain stem and the posterior fossa and the ventricular width in all populations for their reliability and differences between the groups. RESULTS: The transverse cerebellar diameter, cerebellar herniation level, clivus-supraocciput angle, transverse diameter of the posterior fossa, posterior fossa area, and ventricular width showed an acceptable intra- and interobserver reliability (intraclass correlation coefficient > 0.5). In fetuses with open spinal dysraphism, these measurements were significantly different from those of healthy fetuses (all with P < .0001). Furthermore, they also changed significantly (P value range = .01 to < .0001) within 1 week after the fetal operation with an evolution toward normal, most evident for the clivus-supraocciput angle (65.9 ± 12.5°; 76.6 ± 10.9; P < .0001) and cerebellar herniation level (−9.9 ± 4.2 mm; −0.7 ± 5.2; P < .0001). CONCLUSIONS: In fetuses with open spinal dysraphism, brain stem measurements varied substantially between observers. However, measurements characterizing the posterior fossa could be reliably assessed and were significantly different from normal. Following a fetal operation, these deviations from normal values changed significantly within 1 week.
- 27 December 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (1) , 191-198
Open AccessReliability of MR Imaging–Based Posterior Fossa and Brain Stem Measurements in Open Spinal Dysraphism in the Era of Fetal Surgery
BACKGROUND AND PURPOSE: Fetal MR imaging is part of the comprehensive prenatal assessment of fetuses with open spinal dysraphism. We aimed to assess the reliability of brain stem and posterior fossa measurements; use the reliable measurements to characterize fetuses with open spinal dysraphism versus what can be observed in healthy age-matched controls; and document changes in those within 1 week after prenatal repair. MATERIALS AND METHODS: Retrospective evaluation of 349 MR imaging examinations took place, including 274 in controls and 52 in fetuses with open spinal dysraphism, of whom 23 underwent prenatal repair and had additional early postoperative MR images. We evaluated measurements of the brain stem and the posterior fossa and the ventricular width in all populations for their reliability and differences between the groups. RESULTS: The transverse cerebellar diameter, cerebellar herniation level, clivus-supraocciput angle, transverse diameter of the posterior fossa, posterior fossa area, and ventricular width showed an acceptable intra- and interobserver reliability (intraclass correlation coefficient > 0.5). In fetuses with open spinal dysraphism, these measurements were significantly different from those of healthy fetuses (all with P < .0001). Furthermore, they also changed significantly (P value range = .01 to < .0001) within 1 week after the fetal operation with an evolution toward normal, most evident for the clivus-supraocciput angle (65.9 ± 12.5°; 76.6 ± 10.9; P < .0001) and cerebellar herniation level (−9.9 ± 4.2 mm; −0.7 ± 5.2; P < .0001). CONCLUSIONS: In fetuses with open spinal dysraphism, brain stem measurements varied substantially between observers. However, measurements characterizing the posterior fossa could be reliably assessed and were significantly different from normal. Following a fetal operation, these deviations from normal values changed significantly within 1 week.
- 1 April 2017
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 98 (4) , 361-364
Cardiac angiosarcoma: A possible relationship with recurrent hemorrhagic pericarditis
- 1 April 2017
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 98 (4) , 361-364
Cardiac angiosarcoma: A possible relationship with recurrent hemorrhagic pericarditis
- 1 January 2016
- Published by Elsevier in International Journal of Cardiology
- Vol. 202, 950-951
Cardiac myxoma imaging features and tissue characteristics at cardiovascular magnetic resonance
- 1 January 2016
- Published by Elsevier in International Journal of Cardiology
- Vol. 202, 950-951
Cardiac myxoma imaging features and tissue characteristics at cardiovascular magnetic resonance
- Open Access
- 15 April 2015
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 10 (5) , 379-387
Three‐dimensional contrasted visualization of pancreas in rats using clinical MRI and CT scanners
The purpose of this work was to visualize the pancreas in post‐mortem rats with local contrast medium infusion by three‐dimensional (3D) magnetic resonance imaging (MRI) and computed tomography (CT) using clinical imagers. A total of 16 Sprague Dawley rats of about 300 g were used for the pancreas visualization. Following the baseline imaging, a mixed contrast medium dye called GadoIodo‐EB containing optimized concentrations of Gd‐DOTA, iomeprol and Evens blue was infused into the distally obstructed common bile duct (CBD) for post‐contrast imaging with 3.0 T MRI and 128‐slice CT scanners. Images were post‐processed with the MeVisLab software package. MRI findings were co‐registered with CT scans and validated with histomorphology, with relative contrast ratios quantified. Without contrast enhancement, the pancreas was indiscernible. After infusion of GadoIodo‐EB solution, only the pancreatic region became outstandingly visible, as shown by 3D rendering MRI and CT and proven by colored dissection and histological examinations. The measured volume of the pancreas averaged 1.12 ± 0.04 cm3 after standardization. Relative contrast ratios were 93.28 ± 34.61% and 26.45 ± 5.29% for MRI and CT respectively. We have developed a multifunctional contrast medium dye to help clearly visualize and delineate rat pancreas in situ using clinical MRI and CT scanners. The topographic landmarks thus created with 3D demonstration may help to provide guidelines for the next in vivo pancreatic MRI research in rodents. Copyright © 2015 John Wiley & Sons, Ltd.
- 15 April 2015
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 10 (5) , 379-387
Open AccessThree‐dimensional contrasted visualization of pancreas in rats using clinical MRI and CT scanners
The purpose of this work was to visualize the pancreas in post‐mortem rats with local contrast medium infusion by three‐dimensional (3D) magnetic resonance imaging (MRI) and computed tomography (CT) using clinical imagers. A total of 16 Sprague Dawley rats of about 300 g were used for the pancreas visualization. Following the baseline imaging, a mixed contrast medium dye called GadoIodo‐EB containing optimized concentrations of Gd‐DOTA, iomeprol and Evens blue was infused into the distally obstructed common bile duct (CBD) for post‐contrast imaging with 3.0 T MRI and 128‐slice CT scanners. Images were post‐processed with the MeVisLab software package. MRI findings were co‐registered with CT scans and validated with histomorphology, with relative contrast ratios quantified. Without contrast enhancement, the pancreas was indiscernible. After infusion of GadoIodo‐EB solution, only the pancreatic region became outstandingly visible, as shown by 3D rendering MRI and CT and proven by colored dissection and histological examinations. The measured volume of the pancreas averaged 1.12 ± 0.04 cm3 after standardization. Relative contrast ratios were 93.28 ± 34.61% and 26.45 ± 5.29% for MRI and CT respectively. We have developed a multifunctional contrast medium dye to help clearly visualize and delineate rat pancreas in situ using clinical MRI and CT scanners. The topographic landmarks thus created with 3D demonstration may help to provide guidelines for the next in vivo pancreatic MRI research in rodents. Copyright © 2015 John Wiley & Sons, Ltd.