XJXuquan Ji

Xuquan Ji

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xuquan Ji has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Wenyong Liu

    Key Laboratory of Biomechanics and Mechanobiology (Beihang University) Ministry of Education Key Laboratory of Innovation and Transformation of Advanced Medical Devices Ministry of Industry and Information Technology National Medical Innovation Platform for Industry‐Education Integration in Advanced Medical Devices (Interdiscipline of Medicine and Engineering) School of Biological Science and Medical Engineering Beihang University Beijing China

    5 shared publications
  • Lei Hu

    2 shared publications
  • Lei Hu

    School of Mechanical Engineering and Automation, Beihang University, Beijing 100083, China

    2 shared publications
  • Yonghong Zhang

    2 shared publications
  • Yonghong Zhang

    School of Mechanical Engineering and Automation, Beihang University, Beijing 100083, China

    2 shared publications
  • Biao Yang

    Suzhou Zhuzheng Robot Co. Ltd. Suzhou China

    1 shared publication

Latest Publications

  • Open Access

    STP-Net-based respiratory prediction method for autonomous laminectomy surgical robots

    by Xuquan Ji, Zhuofu Li, Yonghong Zhang, Yuanyuan Zhu, Lei Hu, Weishi Li, Wenyong Liu

  • Breakthrough Recognition in Robotic‐Assisted UBE Surgery Based on Force Sensing and VAE‐MLP

    by Xuquan Ji, Yonghong Zhang, Yuanyuan Zhu, Biao Yang, Lei Hu, Yu Zhao, Wenyong Liu

    Background: Robotic‐assisted unilateral biportal endoscopic surgery (UBE) is a more accurate and safer technique than traditional open surgical operations. The penetration recognition of ultrasonic drilling remains one of the challenging techniques of robotic‐assisted UBE surgery.Methods: We propose a force and VAE‐MLP‐based method for real‐time penetration recognition. During the ultrasonic drilling procedure, the force signals are collected and denoised via Kalman filtering first. The pre‐processed data are then used to extract hidden features and perform classification by Variational Autoencoder (VAE) and Multilayer Perceptron (MLP), respectively, ultimately achieving real‐time penetration recognition.Results: Our method achieves superior accuracy (99.32% vs. 95.90%) and faster inference speed (17 vs. 33 ms) compared to the classic time‐series classification algorithm. Robotic ex vivo bone experiments further validated its efficacy.Conclusion: The force and VAE‐MLP framework enables fast and accurate penetration detection, which offers a reliable and efficient solution for minimizing nerve damage in UBE surgery.

  • Open Access

    DRHT: A Hybrid Mathematical Model for Accurate Ultrasound Probe Calibration and Efficient 3D Reconstruction

    by Xuquan Ji, Yonghong Zhang, Huaqing Shang, Lei Hu, Xiaozhi Qi, Wenyong Liu

    The calibration of ultrasound probes is essential for three-dimensional ultrasound reconstruction and navigation. However, the existing calibration methods are often cumbersome and inadequate in accuracy. In this paper, a hybrid mathematical model, Dimensionality Reduction and Homography Transformation (DRHT), is proposed. The model characterizes the relationship between the image plane of ultrasound and projected calibration lines and homography transformation. The homography transformation, which can be estimated using the singular value decomposition method, reduces the dimensionality of the calibration data and could significantly accelerate the computation of image points in ultrasonic three-dimensional reconstruction. Experiments comparing the DRHT method with the PLUS library demonstrated that DRHT outperformed the PLUS algorithm in terms of accuracy (0.89 mm vs. 0.92 mm) and efficiency (268 ms vs. 761 ms). Furthermore, high-precision calibration can be achieved with only four images, which greatly simplifies the calibration process and enhances the feasibility of the clinical application of this model.


  • Open Access

    2D/3D-MGR: A 2D/3D Medical Image Registration Framework Based on DRR

    by Zhuoyuan Li, Xuquan Ji, Chuantao Wang, Wenyong Liu, Feiyu Zhu, Jiliang Zhai

    Medical image registration is a crucial process in medical image analysis. However, traditional 2D and 3D medical image registration methods often struggle to accommodate the complex variations and conditions present in medical images. To address these challenges, this study introduces a novel 2D/3D image registration framework, termed 2D/3D-MGR, which leverages digitally reconstructed radiographs (DRR) to establish consistency between X-ray and computed tomography (CT) images. This research introduces the DCT-Net model for style transfer between DRR and X-ray images, and the CR-Net model for precise registration of intraoperative X-ray images with preoperative CT images. To validate the effectiveness of the proposed models, orthopedic X-ray and CT images were collected from Peking Union Medical College Hospital to create the XC dataset. Empirical results demonstrate that the DCT-Net model achieves a transformation quality level endorsed by medical experts, and the realistic style transfer is significant for subsequent image registration and surgical navigation. Additionally, the CR-Net model outperforms other state-of-the-art models in image registration accuracy, as evidenced by outstanding performance metrics on the XC spine dataset: a Pointwise Location Consistency (PLC) of 99.997% and a Root Mean Square Error (RMSE) of 0.1707. This novel image registration method significantly enhances the accuracy and efficiency of medical image processing, providing a valuable reference for future research in medical image registration.


  • A 2-DOFs Planar Grinding End-Effector for Robotic Laminectomy

    by Wei Duan, Xuquan Ji, Lei Hu, Wenyong Liu

    Robotic end effector accurately operated in small and confined surgical area in laminectomy can improve the efficiency of robotic surgery. This paper proposed a two-DOFs planar grinding end-effector for robotic laminectomy, which can move along any curve within the planar operation area. The end-effector adopts an arc RCM mechanism, which kinematic analysis gives a working space of an annular sector with a minimum radius of 137 mm, a maximum radius of 162.3 mm, a central angle of 1.65 rad. The structure rationality of the end-effector is verified through static analysis. The prototype was developed and controlled based on TwinCAT-PC architecture. Experiments of positioning accuracy give a repeated positioning accuracy of 0.1 mm. Experiments of ex vivo bone grinding gives an operation accuracy of 1.5 mm in a simulated clinical environment. The proposed prototype can be used for robotic laminectomy in combination with the navigation robotic arm.

  • Accuracy Evaluation of a Novel Spinal Robotic System for Autonomous Laminectomy in Thoracic and Lumbar Vertebrae

    by Zhuofu Li, Chengxia Wang, Xiongkang Song, Shanshan Liu, Yonghong Zhang, Shuai Jiang, Xuquan Ji, Tianyang Zhang, Fei Xu, Lei Hu, et al.

    Background: The main function of robots in spine surgery is to assist with pedicle screw placement. Laminectomy, which is as important as pedicle screw placement, lacks a mature robot-assisted system. The aims of this study were to introduce the first autonomous laminectomy robot, to explore the feasibility of autonomous robotic laminectomy, and to validate its accuracy using a cadaveric model. Methods: Forty vertebrae from 4 cadavers were included in the study; 7 thoracic and 3 lumbar vertebrae were randomly selected in each cadaver. The surgeon was able to plan the laminectomy path based on computed tomographic (CT) data before the surgical procedure. The robot performed the laminectomy autonomously, and a postoperative CT scan was made. The deviation of each cutting plane from the plan was quantitatively analyzed, and the accuracy and safety were qualitatively evaluated. The time required for the laminectomy was also recorded. Results: Cuts were performed in 80 laminectomy planes (56 for thoracic vertebrae and 24 for lumbar vertebrae). The mean time for 1-sided laminectomy was 333.59 ± 116.49 seconds, which was shorter for thoracic vertebrae (284.41 ± 66.04 seconds) than lumbar vertebrae (448.33 ± 128.65 seconds) (p < 0.001). The mean time for single-level total laminectomy was 814.05 ± 302.23 seconds, which was also shorter for thoracic vertebrae (690.46 ± 165.74 seconds) than lumbar vertebrae (1,102.42 ± 356.13 seconds) (p = 0.002). The mean deviation of the cutting plane from the plan was 0.67 ± 0.30 mm for the most superior cutting point and 0.73 ± 0.31 mm for the most inferior point. There were no significant differences in the deviation between thoracic vertebrae (0.66 ± 0.26 mm) and lumbar vertebrae (0.67 ± 0.38 mm) at the superior cutting point (p = 0.908) and between thoracic vertebrae (0.72 ± 0.30 mm) and lumbar vertebrae (0.73 ± 0.33 mm) at the inferior cutting point (p = 0.923). In the qualitative analysis of the accuracy of the 80 laminectomy planes, 66 (83%) were classified as grade A, 14 (18%) were grade B, and none was grade C. In the safety analysis, 65 planes (81%) were considered safe and the safety of the other 15 planes (19%) was considered uncertain. Conclusions: The results confirmed the accuracy of this robotic system, supporting its use for laminectomy of thoracolumbar vertebrae. Level of Evidence: Therapeutic Level V. See Instructions for Authors for a complete description of levels of evidence.


  • Renal surface reconstruction and segmentation for image-guided surgical navigation of laparoscopic partial nephrectomy

    by Xiaohui Zhang, Xuquan Ji, Junchen Wang, Yubo Fan, Chunjing Tao

    An unpredictable dynamic surgical environment makes it necessary to measure morphological information of target tissue real-time for laparoscopic image-guided navigation. The stereo vision method for intraoperative tissue 3D reconstruction has the most potential for clinical development benefiting from its high reconstruction accuracy and laparoscopy compatibility. However, existing stereo vision methods have difficulty in achieving high reconstruction accuracy in real time. Also, intraoperative tissue reconstruction results often contain complex background and instrument information that prevents clinical development for image-guided systems. Taking laparoscopic partial nephrectomy (LPN) as the research object, this paper realizes a real-time dense reconstruction and extraction of the kidney tissue surface. The central symmetrical Census based semi-global block stereo matching algorithm is proposed to generate a dense disparity map. A GPU-based pixel-by-pixel connectivity segmentation mechanism is designed to segment the renal tissue area. An in-vitro porcine heart, in-vivo porcine kidney and offline clinical LPN data were performed to evaluate the accuracy and effectiveness of our approach. The algorithm achieved a reconstruction accuracy of ± 2 mm with a real-time update rate of 21 fps for an HD image size of 960 × 540, and 91.0% target tissue segmentation accuracy even with surgical instrument occlusions. Experimental results have demonstrated that the proposed method could accurately reconstruct and extract renal surface in real-time in LPN. The measurement results can be used directly for image-guided systems. Our method provides a new way to measure geometric information of target tissue intraoperatively in laparoscopy surgery.