YBYasutaka Baba

Yasutaka Baba

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yasutaka Baba has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Few-Shot Learning for Prostate Cancer Detection on MRI: Comparative Analysis with Radiologists’ Performance

    by Yosuke Yamagishi, Yasutaka Baba, Jun Suzuki, Yoshitaka Okada, Kent Kanao, Masafumi Oyama

    Background Deep-learning models for prostate cancer detection often require large datasets, which can be challenging to obtain and may lead to domain shift issues in various clinical settings. Purpose This study aimed to develop a deep-learning model for prostate cancer detection on magnetic resonance images using few-shot learning and compare its performance with radiologists. Materials and Methods This retrospective study used 99 cases (80 positive, 19 negative) of confirmed prostate cancer, diagnosed through needle biopsy from 2017 to 2022, with 20 cases for training, 5 for validation, and 74 for testing. The 2D transformer model was trained on T2-weighted, diffusion-weighted, and apparent diffusion coefficient map images. Model predictions were compared between the two radiologists using the Matthews correlation coefficient (MCC) and F1 score, and the bootstrap method was used to calculate 95% confidence intervals (CIs). Results Seventy-four patients (mean age, 71 years ± 8; 60 men) were included in the test set. The model achieved an MCC of 0.297 (95% CI: 0.095–0.474) and F1 score of 0.707 (95% CI: 0.598–0.847). Radiologist 1 had an MCC of 0.276 (95% CI: 0.054–0.484) and an F1 score of 0.741 (95% CI: 0.632–0.832), while Radiologist 2 had an MCC of 0.504 (95% CI: 0.289–0.703) and an F1 score of 0.871 (95% CI: 0.800–0.931). The performance of the model was not significantly different from that of Radiologist 1 (MCC difference: 0.021, 95% CI: −0.270–0.306; F1 score difference: −0.034, 95% CI: −0.153–0.078), but was lower than that of Radiologist 2 (F1 difference: −0.16, 95% CI: −0.287– - 0.061). Conclusion A deep-learning model trained on only 20 cases achieved a performance comparable to one radiologist in detecting prostate cancer on magnetic resonance images, demonstrating the potential of few-shot learning in addressing domain shift challenges. Key Results A deep learning model for prostate cancer detection on MRI was developed using only 20 training cases. The model achieved performance comparable to one radiologist (MCC: 0.297 vs 0.276) but lower than another (F1: 0.707 vs 0.871). Few-shot learning demonstrated potential for addressing domain shift challenges in medical imaging AI. Summary Statement Few-shot learning enables development of prostate cancer detection models on MRI with performance comparable to radiologists, using minimal training data.

  • Effects of size and shape of the side holes of a double J stent on the ureter fluid flow after stenosis

    by Seung Bae Lee, Kyung-Wuk Kim, Se-Hyun Park, Yasutaka Baba, Changje Lee, Young Ho Choi, Hyoung-Ho Kim

    The effect of side holes morphology changes in double J stent (DJS) on encrustation was analyzed using computational fluid dynamics (CFD). We analyzed DJS side holes with inner diameter of 1 mm and outer diameters of 1 (type A), 1.2 (type B) and 1.4 (type C) mm, respectively. Concentric stenosis with three intraureteral degree (0%, 12%, and 88%) was analyzed. The flow rate, shear stress and wall shear stress (WSS) distribution were investigated. Urine flow through SH1 before the ureteropelvic junction (UPJ) differed based on the ureteral stenosis degree. The sum of flow rates through the SHs increased with diameter. In the stented ureter with 12% stenosis, the flow rate through SH1 approximately doubled than that without ureteral stenosis, and the flow rate through SH1 was maximal for the type 'C' stent in both 12% and 88% ureteral stenosis. The mean shear stress in the SHs increased with the degree of stenosis. The WSS around the SHs was higher for type 'C' than types A and B. From the flow rates and shear stresses in and around the SHs, the larger SH diameter of the DJS from the UPJ to mid-ureter is expected to induce encrustation reduction, especially in patients with urinary lithiasis.


  • Open Access

    Diagnostic utility of a conventional MRI-based analysis and texture analysis for discriminating between ovarian thecoma-fibroma groups and ovarian granulosa cell tumors

    by Keita Nagawa, Tomoki Kishigami, Fumitaka Yokoyama, Sho Murakami, Toshiharu Yasugi, Yasunobu Takaki, Kaiji Inoue, Saki Tsuchihashi, Satoshi Seki, Yoshitaka Okada, et al.

    Objective: To evaluate the diagnostic utility of conventional magnetic resonance imaging (MRI)-based characteristics and a texture analysis (TA) for discriminating between ovarian thecoma-fibroma groups (OTFGs) and ovarian granulosa cell tumors (OGCTs).Methods: This retrospective multicenter study enrolled 52 patients with 32 OGCTs and 21 OTFGs, which were dissected and pathologically diagnosed between January 2008 and December 2019.MRI-based features (MBFs) and texture features (TFs) were evaluated and compared between OTFGs and OGCTs. A least absolute shrinkage and selection operator (LASSO) regression analysis was performed to select features and construct the discriminating model. ROC analyses were conducted on MBFs, TFs, and their combination to discriminate between the two diseases.Results: We selected 3 features with the highest absolute value of the LASSO regression coefficient for each model: the apparent diffusion coefficient (ADC), peripheral cystic area, and contrast enhancement in the venous phase (VCE) for the MRI-based model; the 10th percentile, difference variance, and maximal correlation coefficient for the TA-based model; and ADC, VCE, and the difference variance for the combination model. The areas under the curves of the constructed models were 0.938, 0.817, and 0.941, respectively. The diagnostic performance of the MRI-based and combination models was similar (p = 0.38), but significantly better than that of the TA-based model (p < 0.05).Conclusions: The conventional MRI-based analysis has potential as a method to differentiate OTFGs from OGCTs. TA did not appear to be of any additional benefit. Further studies are needed on the use of these methods for a preoperative differential diagnosis of these two diseases.


  • Open Access

    Cranio-caudal puncture with computed tomography-guided drainage of a deep pelvic abscess

    by Takuya Mori, Hidenori Mitani, Keigo Chosa, Wataru Fukumoto, Yasutaka Baba, Kazuo Awai

    Purpose Computed tomography (CT)-guided percutaneous drainage has been used to address pelvic abscesses because it is safe and minimally invasive. However, CT-guided drainage has the limitation that the puncture route should be on the same axial slice. A technique for puncturing in the...


  • Open Access

    Percutaneous Thrombin Injection Based on Computational Fluid Dynamics of Femoral Artery Pseudoaneurysms

    by Hyoung-Ho Kim, Kyung-Wuk Kim, Changje Lee, Young Ho Choi, Min Uk Kim, Yasutaka Baba

    Kim HH, et al. Korean J Radiol. 2021 Nov;22(11):1834-1840. https://doi.org/10.3348/kjr.2020.1340


  • Machine-learning integration of CT histogram analysis to evaluate the composition of atherosclerotic plaques: Validation with IB-IVUS

    by Takanori Masuda, Takeshi Nakaura, Yoshinori Funama, Tomokazu Okimoto, Tomoyasu Sato, Toru Higaki, Noritaka Noda, Naoyuki Imada, Yasutaka Baba, Kazuo Awai


  • A new embolic liquid agent comprised of amino acid

    by Yasutaka Baba, Michiyo Higashi, Kazuo Awai

    Transcatheter arterial or venous embolization has been widely used to address solid tumors by occluding the tumor-feeding vessels. It is also performed to treat portosystemic shunts and to stop bleeding by repair of the site of trauma. Commonly used embolic materials are gelatin sponges, coils, beads, and liquid agents such as absolute ethanol, histoacyryl, and onyx. In the field of interventional radiology, embolotherapy is performed routinely. Liquid embolization agents have different characteristics. Their coagulation time, the inflammatory reaction of the vascular wall or surrounding tissue, and their adhesion to the vascular wall vary. PuraMatrix, a liquid embolic agent not yet available for clinical use, is comprised of amino acid. We introduce and discuss preliminary experimental studies to examine its potential for use in humans.


  • Open Access

    Clinical Indication for Computed Tomography During Hepatic Arteriography (CTHA) in Addition to Dynamic CT Studies to Identify Hypervascularity of Hepatocellular Carcinoma

    by Tomoyo Fuji, Yuko Nakamura, Wataru Fukumoto, Kenji Kajiwara, Keigo Chosa, Chihiro Tani, Yoshiko Matsubara, Hiroaki Terada, Yukiko Honda, Koji Arihiro, et al.

    To identify factors benefiting from computed tomography during hepatic arteriography (CTHA) in addition to dynamic CT studies at the preoperative evaluation of the hypervascularity of hepatocellular carcinoma (HCC).


  • Preliminary experimental study on splenic hemodynamics of radiofrequency ablation for the spleen

    by Yasutaka Baba, Sadao Hayashi, Kohei Nagasato, Michiyo Higashi, Takashi Yoshiura

    Purpose: To test the splenic blood flow change after radiofrequency ablation (RFA) of the spleen in a porcine experimental model. Material and methods: Six pigs underwent RFA of the spleen via laparotomy. During the procedure of RFA, clamping of splenic artery (one) and both splenic artery/vein (one) was also performed. Measurement of blood flow of both splenic artery (SA) and splenic vein (SV) with flow-wire at pre- and post-RFA of the spleen was also performed. Results: Ablated splenic lesions were created as estimating ∼50% area of the spleen in all pigs. Resected specimens reveal not only the coagulated necrosis but also the congestion of the spleen. On the SA hemodynamics, maximum peak velocity (MPV) changed from 37 ± 7 to 24 ± 8 cm/s (normal), 11 to 10 cm/s (clamp of the SA), and 12 to 7.5 cm/s (clamp of both SA/SV), respectively. On the SV hemodynamic, MPV changed from 15 ± 5 to 13 ± 4 cm/s (normal), 17 to 15 cm/s (clamp of the SA), and 17 to 26 cm/s (clamp of both SA/SV), respectively. Conclusions: RFA of the spleen could induce coagulation necrosis and reduce the splenic arterial blood flow.