Žarko Janda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Žarko Janda has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Jasna Dragosavac
9 shared publications- Predrag Pejovic
School of Electrical Engineering, University of Belgrade, 11000 Belgrade, Serbia
6 shared publications - Jasna Dragosavac
Univerzitet u Beogradu Elektrotehnički institut Nikola Tesla Koste Glavinića 8a 11000 Beograd Srbija
5 shared publications Jovica V. Milanovic
School of Electrical and Electronic Engineering, The University of Manchester, Manchester, UK
5 shared publications- Ilija Klasnić
Univerzitet u Beogradu Elektrotehnički institut Nikola Tesla Koste Glavinića 8a 11000 Beograd Srbija
4 shared publications J. Dragosavac
4 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 35,p. 73-86
Methodology for assessing voltage-reactive power capability of synchronous units under modified transformer impedance
This paper presents a methodology for evaluating the voltage–reactive power capability of synchronous generators following changes in transformer impedance. The framework integrates per-unit calculations, an equivalent generator–transformer model, and numerical simulations across multiple grid-voltage scenarios. The SIM-Operating Map application provides analytical and graphical verification of reactive margins, limiting factors, and grid-code compliance, supporting operational decision-making and enhancing system security after transformer replacement.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 35,p. 73-86
Open AccessMethodology for assessing voltage-reactive power capability of synchronous units under modified transformer impedance
This paper presents a methodology for evaluating the voltage–reactive power capability of synchronous generators following changes in transformer impedance. The framework integrates per-unit calculations, an equivalent generator–transformer model, and numerical simulations across multiple grid-voltage scenarios. The SIM-Operating Map application provides analytical and graphical verification of reactive margins, limiting factors, and grid-code compliance, supporting operational decision-making and enhancing system security after transformer replacement.
- 1 January 2025
- Published by University Library in Kragujevac
- p. 1339-1348
IMPROVING THE STABILITY OF GRID-FOLLOWING INVERTERS IN RENEWABLE ENERGY SOURCES
The increasing participation of renewable energy sources (RES) in the production mix of modern electricity systems requires advanced converter control technologies, which enable their reliable integration. RES are connected to the grid via inverters, which play a crucial role in this integration. Understanding the different types of inverters, their advantages and disadvantages, allows for efficient management, contributing to the increased stability of the overall system. When multiple inverters are connected to the grid, various types of instability can occur, with frequency ranges from low to high. This paper discusses the instability phenomena introduced by Grid-Following inverters in systems with a high share of RES (wind farms and solar power plants). The paper provides insight into the advantages and disadvantages of this type of inverter compared to Grid-Forming inverters, their impact on system stability, and the intermittent operation of RES. Possible improvements in managing these converters are proposed by introducing additional control circuits that emulate a synchronverter, as confirmed by the simulation results presented.
- 1 January 2025
- Published by University Library in Kragujevac
- p. 1339-1348
IMPROVING THE STABILITY OF GRID-FOLLOWING INVERTERS IN RENEWABLE ENERGY SOURCES
The increasing participation of renewable energy sources (RES) in the production mix of modern electricity systems requires advanced converter control technologies, which enable their reliable integration. RES are connected to the grid via inverters, which play a crucial role in this integration. Understanding the different types of inverters, their advantages and disadvantages, allows for efficient management, contributing to the increased stability of the overall system. When multiple inverters are connected to the grid, various types of instability can occur, with frequency ranges from low to high. This paper discusses the instability phenomena introduced by Grid-Following inverters in systems with a high share of RES (wind farms and solar power plants). The paper provides insight into the advantages and disadvantages of this type of inverter compared to Grid-Forming inverters, their impact on system stability, and the intermittent operation of RES. Possible improvements in managing these converters are proposed by introducing additional control circuits that emulate a synchronverter, as confirmed by the simulation results presented.
- 1 January 2025
- Published by University Library in Kragujevac
- p. 1256-1264
DETERMINATION OF THE MOMENT OF INERTIA OF A UNIT IN A THERMAL POWER PLANT
In a conventional power system structure, synchronous generators provide transient and frequency stability due to the kinetic energy of rotating masses. Increased penetration of renewable energy sources and the gradual shift towards the green agenda result in the shutdown of existing power generation units that rely on fossil fuels, making the system more susceptible to disturbances due to a lack of inertia. Problems that arise in a system facing a lack of inertia can lead to significant financial losses, so it is crucial to assess the amount of inertia provided by the existing units in power plants and determine the minimum critical inertia value that the system should always have. For conventional power generation units, the inertia data of the generator is one of the parameters that can be found in the technical documentation of the generator. However, it is not possible to obtain the same data for turbines, especially for steam turbines. This paper presents a method for calculating the inertia of turbo generators based on the stop recordings of thermal block B1 in the „Nikola Tesla B“ power plant, starting from Newton’s equation of rotational motion, with the aim of contributing to a better understanding of the overall inertia of the system.
- 1 January 2025
- Published by University Library in Kragujevac
- p. 1256-1264
DETERMINATION OF THE MOMENT OF INERTIA OF A UNIT IN A THERMAL POWER PLANT
In a conventional power system structure, synchronous generators provide transient and frequency stability due to the kinetic energy of rotating masses. Increased penetration of renewable energy sources and the gradual shift towards the green agenda result in the shutdown of existing power generation units that rely on fossil fuels, making the system more susceptible to disturbances due to a lack of inertia. Problems that arise in a system facing a lack of inertia can lead to significant financial losses, so it is crucial to assess the amount of inertia provided by the existing units in power plants and determine the minimum critical inertia value that the system should always have. For conventional power generation units, the inertia data of the generator is one of the parameters that can be found in the technical documentation of the generator. However, it is not possible to obtain the same data for turbines, especially for steam turbines. This paper presents a method for calculating the inertia of turbo generators based on the stop recordings of thermal block B1 in the „Nikola Tesla B“ power plant, starting from Newton’s equation of rotational motion, with the aim of contributing to a better understanding of the overall inertia of the system.
- Open Access
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 34,p. 109-127
A three-phase current source inverter with third harmonic injection for grid-connected renewable power sources
A novel three-phase voltage-synchronized current source (VSCS) converter with third harmonic injection is proposed in this paper. Compared with the conventional vector current control (VCC), phaselocked loop (PLL) is completely removed in this method. This new type of current-source inverters is suitable for application in grid-connected renewable power sources. It is based on a three-phase six-pulse inverter topology with unidirectional switches using line-synchronous control to achieve unity displacement factor at the point of common connection. An additional power circuit to implement the third-harmonic current injection technique is used in order to improve the line current total harmonic distortion. The proposed approach ensures stable operation under weak grid conditions. Experimental results on a 1.5 kW prototype with the optimal third harmonic current injection are shown. The theoretical predictions of total harmonic distortion and power factor improvement are confirmed experimentally.
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 34,p. 109-127
Open AccessA three-phase current source inverter with third harmonic injection for grid-connected renewable power sources
A novel three-phase voltage-synchronized current source (VSCS) converter with third harmonic injection is proposed in this paper. Compared with the conventional vector current control (VCC), phaselocked loop (PLL) is completely removed in this method. This new type of current-source inverters is suitable for application in grid-connected renewable power sources. It is based on a three-phase six-pulse inverter topology with unidirectional switches using line-synchronous control to achieve unity displacement factor at the point of common connection. An additional power circuit to implement the third-harmonic current injection technique is used in order to improve the line current total harmonic distortion. The proposed approach ensures stable operation under weak grid conditions. Experimental results on a 1.5 kW prototype with the optimal third harmonic current injection are shown. The theoretical predictions of total harmonic distortion and power factor improvement are confirmed experimentally.
- Open Access
- 1 January 2022
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 32,p. 113-123
Algorithm of reactive power dispatching "per generator" realization on TPP Nikola Tesla A
The algorithm of reactive power dispatching "per generator" realization is presented in the paper. Dispatching "per generator" and "per grid" are two modes of reactive power dispatching used by coordinated reactive power and voltage regulator (GRRS). Reactive power dispatching "per generator" ensures equal heating of the generators, while dispatching "per grid" ensures maximal reactive power reserve when generated reactive power either increases, or decreases. Reactive power dispatching "per generator" is more complex for realization because the dispatching criterion may have wider generator's reactive power operation area than the working capability curve. In these cases, the additional limiting of the generator reactive power is necessary, while other generators take over the remaining reactive power, still considering the reactive power dispatching criteria "per generator" and the limits of the remaining generators. Both reactive power dispatching modes are presented in two examples, while operating near and far from the limit area. Eventually, as the verification of the algorithm and its realization, the operating results of GRRS while dispatching "per generator" is active, are presented.
- 1 January 2022
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 32,p. 113-123
Open AccessAlgorithm of reactive power dispatching "per generator" realization on TPP Nikola Tesla A
The algorithm of reactive power dispatching "per generator" realization is presented in the paper. Dispatching "per generator" and "per grid" are two modes of reactive power dispatching used by coordinated reactive power and voltage regulator (GRRS). Reactive power dispatching "per generator" ensures equal heating of the generators, while dispatching "per grid" ensures maximal reactive power reserve when generated reactive power either increases, or decreases. Reactive power dispatching "per generator" is more complex for realization because the dispatching criterion may have wider generator's reactive power operation area than the working capability curve. In these cases, the additional limiting of the generator reactive power is necessary, while other generators take over the remaining reactive power, still considering the reactive power dispatching criteria "per generator" and the limits of the remaining generators. Both reactive power dispatching modes are presented in two examples, while operating near and far from the limit area. Eventually, as the verification of the algorithm and its realization, the operating results of GRRS while dispatching "per generator" is active, are presented.
- Open Access
- 1 January 2022
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 32,p. 101-111
Estimation of hydrogenerator rotor dynamic thermal margine
Field winding temperature of the synchronous generator is one of limiting factors shaping generator PQ capability curve. Therefore of great operational importance is to have information about this temperature estimated with the utmost accuracy. It can be measured directly using built-in temperature sensors or determined indirectly. With the increasing penetration of renewable energy sources into the high-voltage transmission system, the fundamental changes happen in the way conventional generating units work, including hydrogenerators. They are facing the new operating modes characterized by rapid load changes and an increased number of start-stop cycles. These modes of operation lead to additional thermal stress of the hydrogenerator parts, including the rotor. In order to be able to respond to new demands that they are faced with, it is necessary to estimate the actual thermal capacity of the rotor and its influence on the dynamic hydrogenerator PQ capability curve.
- 1 January 2022
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- No. 32,p. 101-111
Open AccessEstimation of hydrogenerator rotor dynamic thermal margine
Field winding temperature of the synchronous generator is one of limiting factors shaping generator PQ capability curve. Therefore of great operational importance is to have information about this temperature estimated with the utmost accuracy. It can be measured directly using built-in temperature sensors or determined indirectly. With the increasing penetration of renewable energy sources into the high-voltage transmission system, the fundamental changes happen in the way conventional generating units work, including hydrogenerators. They are facing the new operating modes characterized by rapid load changes and an increased number of start-stop cycles. These modes of operation lead to additional thermal stress of the hydrogenerator parts, including the rotor. In order to be able to respond to new demands that they are faced with, it is necessary to estimate the actual thermal capacity of the rotor and its influence on the dynamic hydrogenerator PQ capability curve.
- Open Access
- 14 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
A Fast Finite Sample Count Symmetric Component Extraction Method for Use in Grid Side Converters
This paper proposes a new method for very fast extraction of symmetrical components.
- 14 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessA Fast Finite Sample Count Symmetric Component Extraction Method for Use in Grid Side Converters
This paper proposes a new method for very fast extraction of symmetrical components.
- Open Access
- 1 January 2020
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- Vol. 30 (30) , 81-91
Load angle estimation of synchronous generator
In this paper a load angle estimation method of round rotor synchronous generator is presented, for load angle limiter in AVR systems design purpose. To get information of load angle, it is necessary to have values of the one terminal voltage, one phase current and q-axis reactance Xq. Mentioned values are acquired by synchronous sampling technique and processed by discrete Fourier transformation. The accuracy of presented method highly depends on quality of zero-crossing detection of the input voltage signal and on the calculation estimation of the fundamental frequency. This method is of reduced sensitivity to higher harmonics presence contence in voltages and current waveforms. Another advantage, when compared to other dq or ab based calculations estimations, is the necessity of use only two measurement channels. Drawback of described approach is lack of immunity to current asymmetry. However, a solution to overcome this problem is offered by introducing the additional measurements into the algorithm to extract the synchronous sampled direct components of all three phase currents.
- 1 January 2020
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- Vol. 30 (30) , 81-91
Open AccessLoad angle estimation of synchronous generator
In this paper a load angle estimation method of round rotor synchronous generator is presented, for load angle limiter in AVR systems design purpose. To get information of load angle, it is necessary to have values of the one terminal voltage, one phase current and q-axis reactance Xq. Mentioned values are acquired by synchronous sampling technique and processed by discrete Fourier transformation. The accuracy of presented method highly depends on quality of zero-crossing detection of the input voltage signal and on the calculation estimation of the fundamental frequency. This method is of reduced sensitivity to higher harmonics presence contence in voltages and current waveforms. Another advantage, when compared to other dq or ab based calculations estimations, is the necessity of use only two measurement channels. Drawback of described approach is lack of immunity to current asymmetry. However, a solution to overcome this problem is offered by introducing the additional measurements into the algorithm to extract the synchronous sampled direct components of all three phase currents.
- Open Access
- 1 January 2020
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- Vol. 30 (30) , 11-29
Starting the synchronous motor in the PAP 'Lisina' by a generator from the HPP 'Vrla 1'
This paper describes test that was done in order to balance the synchronous motor rotor installed in plant PAP "Lisina". To perform balancing, it was necessary to slowly rotate the motor rotor up to synchronous speed. This was done by using one of the available generators from the nearby hydro power plant HPP "Vrla 1" to supply motor under test. The synchronous motor is driven asynchronously with a constant U/f ratio during balancing. Before that, the necessary experimental parameters were calculated in order to properly adjust all equipment used. The experiment is illustrated with recorder time diagrams showing the stator speed, voltage and current as well as the current in the synchronous motor rotor during motor run-in.
- 1 January 2020
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- Vol. 30 (30) , 11-29
Open AccessStarting the synchronous motor in the PAP 'Lisina' by a generator from the HPP 'Vrla 1'
This paper describes test that was done in order to balance the synchronous motor rotor installed in plant PAP "Lisina". To perform balancing, it was necessary to slowly rotate the motor rotor up to synchronous speed. This was done by using one of the available generators from the nearby hydro power plant HPP "Vrla 1" to supply motor under test. The synchronous motor is driven asynchronously with a constant U/f ratio during balancing. Before that, the necessary experimental parameters were calculated in order to properly adjust all equipment used. The experiment is illustrated with recorder time diagrams showing the stator speed, voltage and current as well as the current in the synchronous motor rotor during motor run-in.
- Open Access
- 1 January 2019
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- Vol. 29 (29) , 113-124
Enhanced single phase static transfer switch control
The proposed modification of static transfer switch control algorithm enables safe and reliable load supply commutation in case of non-linear and capacitive loads. Experimental results derived on uninterruptible power supply static transfer switch connected to real industrial load are presented and explained. The design guidelines are outlined for thyristor and rapid fuse selection, regarding simulation results.
- 1 January 2019
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
- Vol. 29 (29) , 113-124
Open AccessEnhanced single phase static transfer switch control
The proposed modification of static transfer switch control algorithm enables safe and reliable load supply commutation in case of non-linear and capacitive loads. Experimental results derived on uninterruptible power supply static transfer switch connected to real industrial load are presented and explained. The design guidelines are outlined for thyristor and rapid fuse selection, regarding simulation results.