Iaroslav Meleshenkovskii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Iaroslav Meleshenkovskii has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
E. Mauerhofer
Jülich Centre for Neutron Science, Forschungszentrum Jülich GmbH, Jülich, Germany
4 shared publicationsN. Pauly
Service de Métrologie Nucléaire (CP/165/84)
3 shared publicationsP. -E. Labeau
Service de Métrologie Nucléaire (CP/165/84)
2 shared publicationsC. Datema
Dynaxion, High Tech Campus 12, NL-5656 AE Eindhoven, Netherlands
1 shared publication- Eric Mauerhofer
Johannes Gutenberg Universität
1 shared publication K. Van Den Brandt
Dynaxion, High Tech Campus 12, NL-5656 AE Eindhoven, Netherlands
1 shared publication
Latest Publications
- Open Access
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
A novel framework for qualitative and quantitative isotopic analysis of plutonium materials using VAE
Background. The determination of plutonium isotopic composition from γ-ray energy spectra is essential for nuclear safeguards and material characterization. However, spectral features depend not only on isotopic composition but also on detector response and measurement conditions, which complicates the analysis, particularly for medium resolution detectors.Purpose. This work proposes a data-driven framework to extract isotopic composition information from γ−spectra of plutonium bearing materials while accounting for detector characteristics and measurement conditions.Methods. The proposed method is based on a VAE architecture implemented within the isotopic analysis code Plutonium Isotopic Analysis variatioNal autoencOder (PIANO). The model incorporates explicit parametrization of detector types and measurement conditions, enabling it to capture the relationships between spectrometric features and isotopic composition. Training and validation were conducted using plutonium−X and γ−ray spectra from the ESARDA and the IDB databases acquired with high-resolution HPGe detectors and medium-resolution room-temperature detectors such as CZT and LaBr3.Results. The algorithm accurately reconstructs experimental spectra and successfully retrieves the isotopic composition of plutonium samples. The method handles gamma peaks with varying shapes and widths, including asymmetric CZT peaks, and remains robust in the presence of peak overlap commonly observed in medium-resolution spectra.Conclusions. The proposed VAE framework provides a novel fast and robust solution for isotopic analysis of plutonium materials using X− and γ−ray spectra. By learning directly from experimental data and incorporating detector parameters, it enables reliable qualitative and quantitative isotopic analysis. The official implementation of the algorithm is available at https://github.com/Tarysa/Plutonium-Isotopic-Analysis-variatioNal-autoencOder
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA novel framework for qualitative and quantitative isotopic analysis of plutonium materials using VAE
Background. The determination of plutonium isotopic composition from γ-ray energy spectra is essential for nuclear safeguards and material characterization. However, spectral features depend not only on isotopic composition but also on detector response and measurement conditions, which complicates the analysis, particularly for medium resolution detectors.Purpose. This work proposes a data-driven framework to extract isotopic composition information from γ−spectra of plutonium bearing materials while accounting for detector characteristics and measurement conditions.Methods. The proposed method is based on a VAE architecture implemented within the isotopic analysis code Plutonium Isotopic Analysis variatioNal autoencOder (PIANO). The model incorporates explicit parametrization of detector types and measurement conditions, enabling it to capture the relationships between spectrometric features and isotopic composition. Training and validation were conducted using plutonium−X and γ−ray spectra from the ESARDA and the IDB databases acquired with high-resolution HPGe detectors and medium-resolution room-temperature detectors such as CZT and LaBr3.Results. The algorithm accurately reconstructs experimental spectra and successfully retrieves the isotopic composition of plutonium samples. The method handles gamma peaks with varying shapes and widths, including asymmetric CZT peaks, and remains robust in the presence of peak overlap commonly observed in medium-resolution spectra.Conclusions. The proposed VAE framework provides a novel fast and robust solution for isotopic analysis of plutonium materials using X− and γ−ray spectra. By learning directly from experimental data and incorporating detector parameters, it enables reliable qualitative and quantitative isotopic analysis. The official implementation of the algorithm is available at https://github.com/Tarysa/Plutonium-Isotopic-Analysis-variatioNal-autoencOder
- Open Access
- 5 September 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (9) , 1-22
A new generative framework for fast parametric modeling of $X-$ and $\gamma -$ray energy spectra using VAEThis paper proposes a variational autoencoder-based technique for the fast modeling of various $$X-$$ or $$\gamma -$$ ray spectra, including the parametrization of the physical measurement conditions, and introduces the SpectroGAN simulation tool. The generated spectra reproduce the training data with high precision. Still, they may vary according to the parameters of interest, such as detector energy resolution, efficiency, attenuation, activity, enrichment, or isotopic composition. Our results demonstrate that machine learning-based spectra simulations have several potential advantages over Monte Carlo-based simulation methods. First, they are much faster and more efficient to calculate. Second, they can provide accurate spectra even if the expected conditions are not included in the training dataset. The data-based model can learn complex relationships between the detector characteristics, measurement configuration, and the spectrometric features examined (such as signature peaks of elements). Finally, they can generate large amounts of synthetic data for training other machine learning models, such as those used in data analysis or pattern recognition. Overall, the data-based spectrometry can be generalized to various other applied radiation measurement tasks, including passive and active non-destructive measurement techniques featuring prompt and delayed neutrons and or gamma-rays detection, PGNAA and PGAINS applications, offering new opportunities for measurement system configuration optimization, as well as detector design. Official implementation is available at https://github.com/Tarysa/fast-parametric-modeling-of-X-and-ray-energy-spectra-using-VAE.- 5 September 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (9) , 1-22
Open AccessA new generative framework for fast parametric modeling of $X-$ and $\gamma -$ray energy spectra using VAEThis paper proposes a variational autoencoder-based technique for the fast modeling of various $$X-$$ or $$\gamma -$$ ray spectra, including the parametrization of the physical measurement conditions, and introduces the SpectroGAN simulation tool. The generated spectra reproduce the training data with high precision. Still, they may vary according to the parameters of interest, such as detector energy resolution, efficiency, attenuation, activity, enrichment, or isotopic composition. Our results demonstrate that machine learning-based spectra simulations have several potential advantages over Monte Carlo-based simulation methods. First, they are much faster and more efficient to calculate. Second, they can provide accurate spectra even if the expected conditions are not included in the training dataset. The data-based model can learn complex relationships between the detector characteristics, measurement configuration, and the spectrometric features examined (such as signature peaks of elements). Finally, they can generate large amounts of synthetic data for training other machine learning models, such as those used in data analysis or pattern recognition. Overall, the data-based spectrometry can be generalized to various other applied radiation measurement tasks, including passive and active non-destructive measurement techniques featuring prompt and delayed neutrons and or gamma-rays detection, PGNAA and PGAINS applications, offering new opportunities for measurement system configuration optimization, as well as detector design. Official implementation is available at https://github.com/Tarysa/fast-parametric-modeling-of-X-and-ray-energy-spectra-using-VAE. - Open Access
- 1 July 2024
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 139 (7)
Numerical intercomparison of PHITS and Geant4 Monte Carlo codes for fast neutron inelastic scattering applications
Fast neutron inelastic scattering is a promising non-destructive assay technique for various analytical applications. As an active neutron interrogation technique, its performance is a function of various different factors and parameters that require optimization. Monte Carlo simulation codes are indispensable for such tasks. However, the internal simulation routines implemented in such codes can rely on different physical models that can yield discrepancies in the simulation results. In this work we conduct an intercomparison of PHITS and Geant4 codes performance in application to fast neutron inelastic scattering simulations. The goal of this paper is twofold. First, we explain the differences in code configuration with respect to gamma and neutron transport, as well as internal simulation routines. Second, we conduct a performance assessment of the two codes using two different measurement configurations. One configuration consisted of a source of gamma rays in a broad energy range (100–9000 keV) and a CeBr3 detector. The other configuration consisted of a monoenergetic 2.5 MeV fast neutron source, Fe, Nd, Dy, B targets and a CeBr3 detector. Selected simulation configurations were chosen with a goal to compare the performance differences in neutron energy distribution, produced prompt gamma rays and energy deposition in CeBr3 detector between the two codes. Results of our study reveal a good coherence of both codes performance in the application of fast neutron inelastic scattering simulations. The simulation geometries and observed differences are described in detail.
- 1 July 2024
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 139 (7)
Open AccessNumerical intercomparison of PHITS and Geant4 Monte Carlo codes for fast neutron inelastic scattering applications
Fast neutron inelastic scattering is a promising non-destructive assay technique for various analytical applications. As an active neutron interrogation technique, its performance is a function of various different factors and parameters that require optimization. Monte Carlo simulation codes are indispensable for such tasks. However, the internal simulation routines implemented in such codes can rely on different physical models that can yield discrepancies in the simulation results. In this work we conduct an intercomparison of PHITS and Geant4 codes performance in application to fast neutron inelastic scattering simulations. The goal of this paper is twofold. First, we explain the differences in code configuration with respect to gamma and neutron transport, as well as internal simulation routines. Second, we conduct a performance assessment of the two codes using two different measurement configurations. One configuration consisted of a source of gamma rays in a broad energy range (100–9000 keV) and a CeBr3 detector. The other configuration consisted of a monoenergetic 2.5 MeV fast neutron source, Fe, Nd, Dy, B targets and a CeBr3 detector. Selected simulation configurations were chosen with a goal to compare the performance differences in neutron energy distribution, produced prompt gamma rays and energy deposition in CeBr3 detector between the two codes. Results of our study reveal a good coherence of both codes performance in the application of fast neutron inelastic scattering simulations. The simulation geometries and observed differences are described in detail.
- Open Access
- 8 May 2024
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (4) , 3013
Correction to: Numerical study on the characterization of NdFeB permanent magnets with fast-neutrons induced (n, n′γ) reactions
- 8 May 2024
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (4) , 3013
Open AccessCorrection to: Numerical study on the characterization of NdFeB permanent magnets with fast-neutrons induced (n, n′γ) reactions
- Open Access
- 8 April 2024
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 333 (5) , 2487-2494
Numerical study on the characterization of NdFeB permanent magnets with fast-neutrons induced (n, n′γ) reactions
The potential of prompt gamma analysis based on inelastic scattering of 2.5 MeV neutrons for a rapid characterization of NdFeB permanent magnets is investigated by means of numerical simulations using an HPGe detector and a CZT detector-array. The results show that rapid assay of a 42 g magnet can be achieved in some minutes when the neutron flux at sample position is about 1.6 × 109 cm−2 s−1 and the detector count rate limited to 500 kcps. Such a high neutron flux could be delivered by a compact 5 MeV proton accelerator with a thick beryllium target for neutron production through the 9Be(p,xn)9Be.
- 8 April 2024
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 333 (5) , 2487-2494
Open AccessNumerical study on the characterization of NdFeB permanent magnets with fast-neutrons induced (n, n′γ) reactions
The potential of prompt gamma analysis based on inelastic scattering of 2.5 MeV neutrons for a rapid characterization of NdFeB permanent magnets is investigated by means of numerical simulations using an HPGe detector and a CZT detector-array. The results show that rapid assay of a 42 g magnet can be achieved in some minutes when the neutron flux at sample position is about 1.6 × 109 cm−2 s−1 and the detector count rate limited to 500 kcps. Such a high neutron flux could be delivered by a compact 5 MeV proton accelerator with a thick beryllium target for neutron production through the 9Be(p,xn)9Be.
- 2 September 2019
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 134 (9) , 418
Making isotopic composition artificially intelligent: Conceptual design and performance assessment of pattern recognition algorithms for uranium enrichment determination tasks using CZT and LaBr3(Ce) detectors
- 2 September 2019
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 134 (9) , 418
Making isotopic composition artificially intelligent: Conceptual design and performance assessment of pattern recognition algorithms for uranium enrichment determination tasks using CZT and LaBr3(Ce) detectors
- 1 June 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 148, 277-289
Determination of the uranium enrichment without calibration standards using a 500 mm3 CdZnTe room temperature detector with a hybrid methodology based on peak ratios method and Monte Carlo counting efficiency simulations
- 1 June 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 148, 277-289
Determination of the uranium enrichment without calibration standards using a 500 mm3 CdZnTe room temperature detector with a hybrid methodology based on peak ratios method and Monte Carlo counting efficiency simulations