Selvia Maged Adly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Selvia Maged Adly has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Mohamed Ahmed Elsayed
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Fayoum University, Fayoum 63514, Egypt
3 shared publications - Hany Hunter Monir
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo ET-11562, Egypt
2 shared publications - Safa'A Mohamed Riad
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
2 shared publications Hany H. Monir
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Egypt
1 shared publicationMaha M Abdelrahman
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Beni-Suef University, Alshaheed Shehata Ahmed Hegazy St., Beni-Suef 62514, Egypt
1 shared publicationMaha M. Abdelrahman
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Beni-Suef University, Alshaheed Shehata Ahmed Hegazy St., Beni-Suef 62514, Egypt
1 shared publication
Latest Publications
- 8 April 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (16) , 3305-3319
Masterful ecofriendly maintainable spectrophotometric techniques for considering indacaterol acetate and mometasone furoate: full evaluation and comparison of their greenness, whiteness, and blueness profiles
People of all ages may suffer from asthma. According to recent research, those who have poorly controlled asthma may be more susceptible to hospitalization and severe symptoms from any respiratory infection, particularly severe ones like the COVID-19 and human metapneumovirus (HMPV) viruses, which could result in the death of these critically ill people. Therefore, a study of the mixture of indacaterol acetate and mometasone furoate which is used in the new remarkable anti-asthmatic Breezhaler will produce substantial gains for the scientific field. A binary blend of (INDA) indacaterol acetate (1.00–30.00) μg mL−1, and (MOM) mometasone furoate (1.00–40.00) μg mL−1 was estimated over these ranges using six sensitive, neoteric, rapid, frugal, universal, and explicit spectrophotometric methods using the most satisfactory green solvent: ethanol. These methods are the dual wavelength method, ratio subtraction method, factorized absorbance difference method, advanced absorbance subtraction method, derivative ratio method, and derivative amplitude factor method. These procedures have been sensitively and effectively utilized for the analysis of INDA and MOM in commercial Breezhaler capsules with multiple ratios for the first time with low LOD (0.186 and 0.172) and LOQ values (0.565 and 0.520) for INDA and MOM, respectively, superior to those in other published spectrophotometric work, and they were validated in accordance with ICH specifications. Additionally, they delivered 98–102% recovery percentages and showed RSD% of less than 2 for the studied drugs, confirming their specificity. Ecological aspects of the developed work were evaluated and gave satisfactory results using several evaluation tools [such as NEMI, Eco-Scale (=93), GAPI, AGREE (=76)] for the greenness aspect, RGB (=96.3) for the whiteness aspect, and BAGI (=90) for the blueness aspect. Additionally, an environmental assessment and statistical comparisons were made using Student's t-test and the F-test with the published HPLC method and those methods currently in use.
- 8 April 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (16) , 3305-3319
Masterful ecofriendly maintainable spectrophotometric techniques for considering indacaterol acetate and mometasone furoate: full evaluation and comparison of their greenness, whiteness, and blueness profiles
People of all ages may suffer from asthma. According to recent research, those who have poorly controlled asthma may be more susceptible to hospitalization and severe symptoms from any respiratory infection, particularly severe ones like the COVID-19 and human metapneumovirus (HMPV) viruses, which could result in the death of these critically ill people. Therefore, a study of the mixture of indacaterol acetate and mometasone furoate which is used in the new remarkable anti-asthmatic Breezhaler will produce substantial gains for the scientific field. A binary blend of (INDA) indacaterol acetate (1.00–30.00) μg mL−1, and (MOM) mometasone furoate (1.00–40.00) μg mL−1 was estimated over these ranges using six sensitive, neoteric, rapid, frugal, universal, and explicit spectrophotometric methods using the most satisfactory green solvent: ethanol. These methods are the dual wavelength method, ratio subtraction method, factorized absorbance difference method, advanced absorbance subtraction method, derivative ratio method, and derivative amplitude factor method. These procedures have been sensitively and effectively utilized for the analysis of INDA and MOM in commercial Breezhaler capsules with multiple ratios for the first time with low LOD (0.186 and 0.172) and LOQ values (0.565 and 0.520) for INDA and MOM, respectively, superior to those in other published spectrophotometric work, and they were validated in accordance with ICH specifications. Additionally, they delivered 98–102% recovery percentages and showed RSD% of less than 2 for the studied drugs, confirming their specificity. Ecological aspects of the developed work were evaluated and gave satisfactory results using several evaluation tools [such as NEMI, Eco-Scale (=93), GAPI, AGREE (=76)] for the greenness aspect, RGB (=96.3) for the whiteness aspect, and BAGI (=90) for the blueness aspect. Additionally, an environmental assessment and statistical comparisons were made using Student's t-test and the F-test with the published HPLC method and those methods currently in use.
- 23 November 2023
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 46 (16-20) , 271-281
A modern chromatographic energy-saving approach for the analysis of doxycycline, ambroxol, and its precursor and impurity: Green metric assessment and comparison
- 23 November 2023
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 46 (16-20) , 271-281
A modern chromatographic energy-saving approach for the analysis of doxycycline, ambroxol, and its precursor and impurity: Green metric assessment and comparison
- 2 February 2021
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 59 (5) , 425-431
Development and Validation of Two Novel Chromatographic Methods: HPTLC and HPLC for Determination of Bromhexine Hydrochloride in Presence of Its Two Impurities
Two simple, sensitive and validated chromatographic methods were developed for quantitative determination of bromhexine hydrochloride (BHX) in presence of its major impurities, impurity B (IMB) and impurity C (IMC), as specified by British Pharmacopoeia. First method (I) was high-performance thin layer chromatography-densitometry at which the chromatographic separation was performed using silica gel plates and developing system consisted of hexane:acetone:ammonia solution (9:0.5:0.08, by volume) with ultraviolet scanning at 240 nm and linearity was achieved in the ranges of 0.40–10.00, 0.20–2.00 and 0.20–2.00 μg/band of BHX, IMB and IMC, respectively. Also, second chromatographic method (II) was high-performance liquid chromatography (HPLC) where the separation was carried out on C18 column at isocratic mode at flow rate 1.5 mL/min. The mobile phase consisted of methanol:water (90:10, v/v) adjusted to pH 2.5 with O-phosphoric acid and temperature was adjusted to 40°C. The scanning wavelength was 240 nm. The chromatographic run time was 6 min. Linearity of this method was achieved in the ranges of 4.00–40.00, 0.20–10.00 and 0.50–10.00 μg/mL for BHX, IMB and IMC, respectively. The validation of these chromatographic methods was made according to International Conference on Harmonization guidelines. These methods were successfully applied for determination of BHX in its pharmaceutical formulation. Also, statistical comparison was attained between the developed methods and the reported HPLC method using Student’s t-test and F-test, and the obtained results showed that there was not any significant difference between them concerning with accuracy and precision.
- 2 February 2021
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 59 (5) , 425-431
Development and Validation of Two Novel Chromatographic Methods: HPTLC and HPLC for Determination of Bromhexine Hydrochloride in Presence of Its Two Impurities
Two simple, sensitive and validated chromatographic methods were developed for quantitative determination of bromhexine hydrochloride (BHX) in presence of its major impurities, impurity B (IMB) and impurity C (IMC), as specified by British Pharmacopoeia. First method (I) was high-performance thin layer chromatography-densitometry at which the chromatographic separation was performed using silica gel plates and developing system consisted of hexane:acetone:ammonia solution (9:0.5:0.08, by volume) with ultraviolet scanning at 240 nm and linearity was achieved in the ranges of 0.40–10.00, 0.20–2.00 and 0.20–2.00 μg/band of BHX, IMB and IMC, respectively. Also, second chromatographic method (II) was high-performance liquid chromatography (HPLC) where the separation was carried out on C18 column at isocratic mode at flow rate 1.5 mL/min. The mobile phase consisted of methanol:water (90:10, v/v) adjusted to pH 2.5 with O-phosphoric acid and temperature was adjusted to 40°C. The scanning wavelength was 240 nm. The chromatographic run time was 6 min. Linearity of this method was achieved in the ranges of 4.00–40.00, 0.20–10.00 and 0.50–10.00 μg/mL for BHX, IMB and IMC, respectively. The validation of these chromatographic methods was made according to International Conference on Harmonization guidelines. These methods were successfully applied for determination of BHX in its pharmaceutical formulation. Also, statistical comparison was attained between the developed methods and the reported HPLC method using Student’s t-test and F-test, and the obtained results showed that there was not any significant difference between them concerning with accuracy and precision.
- 1 October 2019
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 32 (5) , 411-420
Development and Validation of Different Spectrophotometric and High-Performance Thin-Layer Chromatographic Methods for the Determination of Fosinopril Sodium, Hydrochlorothiazide, and Chlorothiazide as Hydrochlorothiazide Impurity
Summary Three simple, sensitive, and validated methods were developed for the quantitative determination of fosinopril sodium (FOS) and hydrochlorothiazide (HCZ) in the presence of an HCZ impurity,...
- 1 October 2019
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 32 (5) , 411-420
Development and Validation of Different Spectrophotometric and High-Performance Thin-Layer Chromatographic Methods for the Determination of Fosinopril Sodium, Hydrochlorothiazide, and Chlorothiazide as Hydrochlorothiazide Impurity
Summary Three simple, sensitive, and validated methods were developed for the quantitative determination of fosinopril sodium (FOS) and hydrochlorothiazide (HCZ) in the presence of an HCZ impurity,...
- Open Access
- 31 December 2018
- Published by European Journal of Chemistry in European Journal of Chemistry
- Vol. 9 (4)
Different spectrophotometric and TLC-densitometric methods for determination of olmesartan medoxomil and hydrochlorothiazide and their degradation products
In this work, multivariate calibration models and TLC-densitometric methods have been developed and validated for quantitative determination of olmesartan medoxomil (OLM) and hydrochlorothiazide (HCZ) in presence of their degradation products, olmesartan (OL) and salamide (SAL), respectively. In the first method, multivariate calibration models including principal component regression (PCR) and partial least square (PLS) were applied. The wavelength range 210-343 nm was used and data was auto-scaled and mean centered as pre-processing steps for PCR and PLS models, respectively. These models were tested by application to external validation set with mean percentage recoveries 99.78, 100.01, 100.41 and 100.46% for OLM, HCZ, OL and SAL, respectively, for PLS model and also, 100.22, 100.40, 102.25 and 100.13% for them, respectively, for PCR model. The second method is TLC-densitometry at which the chromatographic separation was carried out using silica gel 60F254 TLC plates and the developing system consisted of a mixture of ethyl acetate:chloroform:methanol: formic acid:tri-ethylamine (60:40:4:4:1, by volume) with UV-scanning at 254 nm. The developed methods were successfully applied for determination of OLM and HCZ in their pharmaceutical dosage form. Also, statistical comparison was made between the developed methods and the reported method using student’s-t test and F-test and results showed that there was no significant difference between them concerning both accuracy and precision.
- 31 December 2018
- Published by European Journal of Chemistry in European Journal of Chemistry
- Vol. 9 (4)
Open AccessDifferent spectrophotometric and TLC-densitometric methods for determination of olmesartan medoxomil and hydrochlorothiazide and their degradation products
In this work, multivariate calibration models and TLC-densitometric methods have been developed and validated for quantitative determination of olmesartan medoxomil (OLM) and hydrochlorothiazide (HCZ) in presence of their degradation products, olmesartan (OL) and salamide (SAL), respectively. In the first method, multivariate calibration models including principal component regression (PCR) and partial least square (PLS) were applied. The wavelength range 210-343 nm was used and data was auto-scaled and mean centered as pre-processing steps for PCR and PLS models, respectively. These models were tested by application to external validation set with mean percentage recoveries 99.78, 100.01, 100.41 and 100.46% for OLM, HCZ, OL and SAL, respectively, for PLS model and also, 100.22, 100.40, 102.25 and 100.13% for them, respectively, for PCR model. The second method is TLC-densitometry at which the chromatographic separation was carried out using silica gel 60F254 TLC plates and the developing system consisted of a mixture of ethyl acetate:chloroform:methanol: formic acid:tri-ethylamine (60:40:4:4:1, by volume) with UV-scanning at 254 nm. The developed methods were successfully applied for determination of OLM and HCZ in their pharmaceutical dosage form. Also, statistical comparison was made between the developed methods and the reported method using student’s-t test and F-test and results showed that there was no significant difference between them concerning both accuracy and precision.