Pengpeng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pengpeng Zhang has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Gikas S. Mageras
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
12 shared publications Laura Happersett
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
8 shared publicationsAndreas Rimner
Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, USA
7 shared publicationsEllen Yorke
Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, USA
6 shared publications- Margie Hunt
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
6 shared publications - Yu-Chi Hu
Memorial Sloan Kettering Cancer Center
6 shared publications
Latest Publications
- Open Access
- 18 May 2026
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 11 (8)
Early Salivary Gland Shrinkage Is Associated With an Increased Risk of Acute Xerostomia in Head and Neck Cancer Radiation Therapy
- 18 May 2026
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 11 (8)
Open AccessEarly Salivary Gland Shrinkage Is Associated With an Increased Risk of Acute Xerostomia in Head and Neck Cancer Radiation Therapy
- 13 August 2024
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 121 (1) , 261-268
Reduction of Postradiation Therapy Urinary Toxicity Via Intrafractional Megavoltage-Kilovoltage Prostate Location Monitoring
- 13 August 2024
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 121 (1) , 261-268
Reduction of Postradiation Therapy Urinary Toxicity Via Intrafractional Megavoltage-Kilovoltage Prostate Location Monitoring
- Open Access
- 10 February 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 29, 100547
Automated planning of stereotactic spine re-irradiation using cumulative dose limits
- 10 February 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 29, 100547
Open AccessAutomated planning of stereotactic spine re-irradiation using cumulative dose limits
- Open Access
- 13 December 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (24) , 7390
A Simulation Study of Tolerance of Breathing Amplitude Variations in Radiotherapy of Lung Cancer Using 4DCT and Time-Resolved 4DMRI
As patient breathing irregularities can introduce a large uncertainty in targeting the internal tumor volume (ITV) of lung cancer patients, and thereby affect treatment quality, this study evaluates dose tolerance of tumor motion amplitude variations in ITV-based volumetric modulated arc therapy (VMAT). A motion-incorporated planning technique was employed to simulate treatment delivery of 10 lung cancer patients’ clinical VMAT plans using original and three scaling-up (by 0.5, 1.0, and 2.0 cm) motion waveforms from single-breath four-dimensional computed tomography (4DCT) and multi-breath time-resolved 4D magnetic resonance imaging (TR-4DMRI). The planning tumor volume (PTV = ITV + 5 mm margin) dose coverage (PTV D95%) was evaluated. The repeated waveforms were used to move the isocenter in sync with the clinical leaf motion and gantry rotation. The continuous VMAT arcs were broken down into many static beam fields at the control points (2°-interval) and the composite plan represented the motion-incorporated VMAT plan. Eight motion-incorporated plans per patient were simulated and the plan with the native 4DCT waveform was used as a control. The first (D95% ≤ 95%) and second (D95% ≤ 90%) plan breaching points due to motion amplitude increase were identified and analyzed. The PTV D95% in the motion-incorporated plans was 99.4 ± 1.0% using 4DCT, closely agreeing with the corresponding ITV-based VMAT plan (PTV D95% = 100%). Tumor motion irregularities were observed in TR-4DMRI and triggered D95% ≤ 95% in one case. For small tumors, 4 mm extra motion triggered D95% ≤ 95%, and 6–8 mm triggered D95% ≤ 90%. For large tumors, 14 mm and 21 mm extra motions triggered the first and second breaching points, respectively. This study has demonstrated that PTV D95% breaching points may occur for small tumors during treatment delivery. Clinically, it is important to monitor and avoid systematic motion increase, including baseline drift, and large random motion spikes through threshold-based beam gating.
- 13 December 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (24) , 7390
Open AccessA Simulation Study of Tolerance of Breathing Amplitude Variations in Radiotherapy of Lung Cancer Using 4DCT and Time-Resolved 4DMRI
As patient breathing irregularities can introduce a large uncertainty in targeting the internal tumor volume (ITV) of lung cancer patients, and thereby affect treatment quality, this study evaluates dose tolerance of tumor motion amplitude variations in ITV-based volumetric modulated arc therapy (VMAT). A motion-incorporated planning technique was employed to simulate treatment delivery of 10 lung cancer patients’ clinical VMAT plans using original and three scaling-up (by 0.5, 1.0, and 2.0 cm) motion waveforms from single-breath four-dimensional computed tomography (4DCT) and multi-breath time-resolved 4D magnetic resonance imaging (TR-4DMRI). The planning tumor volume (PTV = ITV + 5 mm margin) dose coverage (PTV D95%) was evaluated. The repeated waveforms were used to move the isocenter in sync with the clinical leaf motion and gantry rotation. The continuous VMAT arcs were broken down into many static beam fields at the control points (2°-interval) and the composite plan represented the motion-incorporated VMAT plan. Eight motion-incorporated plans per patient were simulated and the plan with the native 4DCT waveform was used as a control. The first (D95% ≤ 95%) and second (D95% ≤ 90%) plan breaching points due to motion amplitude increase were identified and analyzed. The PTV D95% in the motion-incorporated plans was 99.4 ± 1.0% using 4DCT, closely agreeing with the corresponding ITV-based VMAT plan (PTV D95% = 100%). Tumor motion irregularities were observed in TR-4DMRI and triggered D95% ≤ 95% in one case. For small tumors, 4 mm extra motion triggered D95% ≤ 95%, and 6–8 mm triggered D95% ≤ 90%. For large tumors, 14 mm and 21 mm extra motions triggered the first and second breaching points, respectively. This study has demonstrated that PTV D95% breaching points may occur for small tumors during treatment delivery. Clinically, it is important to monitor and avoid systematic motion increase, including baseline drift, and large random motion spikes through threshold-based beam gating.
- 10 November 2022
- Published by Wiley in Medical Physics
- Vol. 50 (2) , 970-979
Seq2Morph: A deep learning deformable image registration algorithm for longitudinal imaging studies and adaptive radiotherapy
Purpose: To simultaneously register all the longitudinal images acquired in a radiotherapy course for analyzing patients’ anatomy changes for adaptive radiotherapy (ART).Methods: To address the unique needs of ART, we designed Seq2Morph, a novel deep learning‐based deformable image registration (DIR) network. Seq2Morph was built upon VoxelMorph which is a general‐purpose framework for learning‐based image registration. The major upgrades are (1) expansion of inputs to all weekly cone‐beam computed tomography (CBCTs) acquired for monitoring treatment responses throughout a radiotherapy course, for registration to their planning CT; (2) incorporation of 3D convolutional long short‐term memory between the encoder and decoder of VoxelMorph, to parse the temporal patterns of anatomical changes; and (3) addition of bidirectional pathways to calculate and minimize inverse consistency errors (ICEs). Longitudinal image sets from 50 patients, including a planning CT and 6 weekly CBCTs per patient, were utilized for network training and cross‐validation. The outputs were deformation vector fields for all the registration pairs. The loss function was composed of a normalized cross‐correlation for image intensity similarity, a DICE for contour similarity, an ICE, and a deformation regularization term. For performance evaluation, DICE and Hausdorff distance (HD) for the manual versus predicted contours of tumor and esophagus on weekly basis were quantified and further compared with other state‐of‐the‐art algorithms, including conventional VoxelMorph and large deformation diffeomorphic metric mapping (LDDMM).Results: Visualization of the hidden states of Seq2Morph revealed distinct spatiotemporal anatomy change patterns. Quantitatively, Seq2Morph performed similarly to LDDMM, but significantly outperformed VoxelMorph as measured by GTV DICE: (0.799±0.078, 0.798±0.081, and 0.773±0.078), and 50% HD (mm): (0.80±0.57, 0.88±0.66, and 0.95±0.60). The per‐patient inference of Seq2Morph took 22 s, much less than LDDMM (∼30 min).Conclusions: Seq2Morph can provide accurate and fast DIR for longitudinal image studies by exploiting spatial‐temporal patterns. It closely matches the clinical workflow and has the potential to serve both online and offline ART.
- 10 November 2022
- Published by Wiley in Medical Physics
- Vol. 50 (2) , 970-979
Seq2Morph: A deep learning deformable image registration algorithm for longitudinal imaging studies and adaptive radiotherapy
Purpose: To simultaneously register all the longitudinal images acquired in a radiotherapy course for analyzing patients’ anatomy changes for adaptive radiotherapy (ART).Methods: To address the unique needs of ART, we designed Seq2Morph, a novel deep learning‐based deformable image registration (DIR) network. Seq2Morph was built upon VoxelMorph which is a general‐purpose framework for learning‐based image registration. The major upgrades are (1) expansion of inputs to all weekly cone‐beam computed tomography (CBCTs) acquired for monitoring treatment responses throughout a radiotherapy course, for registration to their planning CT; (2) incorporation of 3D convolutional long short‐term memory between the encoder and decoder of VoxelMorph, to parse the temporal patterns of anatomical changes; and (3) addition of bidirectional pathways to calculate and minimize inverse consistency errors (ICEs). Longitudinal image sets from 50 patients, including a planning CT and 6 weekly CBCTs per patient, were utilized for network training and cross‐validation. The outputs were deformation vector fields for all the registration pairs. The loss function was composed of a normalized cross‐correlation for image intensity similarity, a DICE for contour similarity, an ICE, and a deformation regularization term. For performance evaluation, DICE and Hausdorff distance (HD) for the manual versus predicted contours of tumor and esophagus on weekly basis were quantified and further compared with other state‐of‐the‐art algorithms, including conventional VoxelMorph and large deformation diffeomorphic metric mapping (LDDMM).Results: Visualization of the hidden states of Seq2Morph revealed distinct spatiotemporal anatomy change patterns. Quantitatively, Seq2Morph performed similarly to LDDMM, but significantly outperformed VoxelMorph as measured by GTV DICE: (0.799±0.078, 0.798±0.081, and 0.773±0.078), and 50% HD (mm): (0.80±0.57, 0.88±0.66, and 0.95±0.60). The per‐patient inference of Seq2Morph took 22 s, much less than LDDMM (∼30 min).Conclusions: Seq2Morph can provide accurate and fast DIR for longitudinal image studies by exploiting spatial‐temporal patterns. It closely matches the clinical workflow and has the potential to serve both online and offline ART.
- Open Access
- 18 February 2022
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 169, 57-63
Deep learning driven predictive treatment planning for adaptive radiotherapy of lung cancer
- 18 February 2022
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 169, 57-63
Open AccessDeep learning driven predictive treatment planning for adaptive radiotherapy of lung cancer
- Open Access
- 29 December 2021
- Published by Wiley in Medical Physics
- Vol. 49 (2) , 1161-1180
The markerless lung target tracking AAPM Grand Challenge (MATCH) results
Purpose: Lung stereotactic ablative body radiotherapy (SABR) is a radiation therapy success story with level 1 evidence demonstrating its efficacy. To provide real‐time respiratory motion management for lung SABR, several commercial and preclinical markerless lung target tracking (MLTT) approaches have been developed. However, these approaches have yet to be benchmarked using a common measurement methodology. This knowledge gap motivated the MArkerless lung target Tracking CHallenge (MATCH). The aim was to localize lung targets accurately and precisely in a retrospective in silico study and a prospective experimental study.Methods: MATCH was an American Association of Physicists in Medicine sponsored Grand Challenge. Common materials for the in silico and experimental studies were the experiment setup including an anthropomorphic thorax phantom with two targets within the lungs, and a lung SABR planning protocol. The phantom was moved rigidly with patient‐measured lung target motion traces, which also acted as ground truth motion. In the retrospective in silico study a volumetric modulated arc therapy treatment was simulated and a dataset consisting of treatment planning data and intra‐treatment kilovoltage (kV) and megavoltage (MV) images for four blinded lung motion traces was provided to the participants. The participants used their MLTT approach to localize the moving target based on the dataset. In the experimental study, the participants received the phantom experiment setup and five patient‐measured lung motion traces. The participants used their MLTT approach to localize the moving target during an experimental SABR phantom treatment. The challenge was open to any participant, and participants could complete either one or both parts of the challenge. For both the in silico and experimental studies the MLTT results were analyzed and ranked using the prospectively defined metric of the percentage of the tracked target position being within 2 mm of the ground truth.Results: A total of 30 institutions registered and 15 result submissions were received, four for the in silico study and 11 for the experimental study. The participating MLTT approaches were: Accuray CyberKnife (2), Accuray Radixact (2), BrainLab Vero, C‐RAD, and preclinical MLTT (5) on a conventional linear accelerator (Varian TrueBeam). For the in silico study the percentage of the 3D tracking error within 2 mm ranged from 50% to 92%. For the experimental study, the percentage of the 3D tracking error within 2 mm ranged from 39% to 96%.Conclusions: A common methodology for measuring the accuracy of MLTT approaches has been developed and used to benchmark preclinical and commercial approaches retrospectively and prospectively. Several MLTT approaches were able to track the target with sub‐millimeter accuracy and precision. The study outcome paves the way for broader clinical implementation of MLTT. MATCH is live, with datasets and analysis software being available online at https://www.aapm.org/GrandChallenge/MATCH/ to support future research.
- 29 December 2021
- Published by Wiley in Medical Physics
- Vol. 49 (2) , 1161-1180
Open AccessThe markerless lung target tracking AAPM Grand Challenge (MATCH) results
Purpose: Lung stereotactic ablative body radiotherapy (SABR) is a radiation therapy success story with level 1 evidence demonstrating its efficacy. To provide real‐time respiratory motion management for lung SABR, several commercial and preclinical markerless lung target tracking (MLTT) approaches have been developed. However, these approaches have yet to be benchmarked using a common measurement methodology. This knowledge gap motivated the MArkerless lung target Tracking CHallenge (MATCH). The aim was to localize lung targets accurately and precisely in a retrospective in silico study and a prospective experimental study.Methods: MATCH was an American Association of Physicists in Medicine sponsored Grand Challenge. Common materials for the in silico and experimental studies were the experiment setup including an anthropomorphic thorax phantom with two targets within the lungs, and a lung SABR planning protocol. The phantom was moved rigidly with patient‐measured lung target motion traces, which also acted as ground truth motion. In the retrospective in silico study a volumetric modulated arc therapy treatment was simulated and a dataset consisting of treatment planning data and intra‐treatment kilovoltage (kV) and megavoltage (MV) images for four blinded lung motion traces was provided to the participants. The participants used their MLTT approach to localize the moving target based on the dataset. In the experimental study, the participants received the phantom experiment setup and five patient‐measured lung motion traces. The participants used their MLTT approach to localize the moving target during an experimental SABR phantom treatment. The challenge was open to any participant, and participants could complete either one or both parts of the challenge. For both the in silico and experimental studies the MLTT results were analyzed and ranked using the prospectively defined metric of the percentage of the tracked target position being within 2 mm of the ground truth.Results: A total of 30 institutions registered and 15 result submissions were received, four for the in silico study and 11 for the experimental study. The participating MLTT approaches were: Accuray CyberKnife (2), Accuray Radixact (2), BrainLab Vero, C‐RAD, and preclinical MLTT (5) on a conventional linear accelerator (Varian TrueBeam). For the in silico study the percentage of the 3D tracking error within 2 mm ranged from 50% to 92%. For the experimental study, the percentage of the 3D tracking error within 2 mm ranged from 39% to 96%.Conclusions: A common methodology for measuring the accuracy of MLTT approaches has been developed and used to benchmark preclinical and commercial approaches retrospectively and prospectively. Several MLTT approaches were able to track the target with sub‐millimeter accuracy and precision. The study outcome paves the way for broader clinical implementation of MLTT. MATCH is live, with datasets and analysis software being available online at https://www.aapm.org/GrandChallenge/MATCH/ to support future research.
- 27 November 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (23) , 235011
Predictive dose accumulation for HN adaptive radiotherapy
During radiation therapy (RT) of head and neck (HN) cancer, the shape and volume of the parotid glands (PG) may change significantly, resulting in clinically relevant deviations of delivered dose from the planning dose. Early and accurate longitudinal prediction of PG anatomical changes during the RT can be valuable to inform decisions on plan adaptation. We developed a deep neural network for longitudinal predictions using the displacement fields (DFs) between the planning computed tomography (pCT) and weekly cone beam computed tomography (CBCT). Sixty-three HN patients treated with volumetric modulated arc were retrospectively studied. We calculated DFs between pCT and week 1–3 CBCT by B-spline and Demon deformable image registration (DIR). The resultant DFs were subsequently used as input to our novel network to predict the week 4 to 6 DFs for generating predicted weekly PG contours and weekly dose distributions. For evaluation, we measured dice similarity (DICE), and the uncertainty of accumulated dose. Moreover, we compared the detection accuracies of candidates for adaptive radiotherapy (ART) when the trigger criteria were mean dose difference more than 10%, 7.5%, and 5%, respectively. The DICE of ipsilateral/contralateral PG at week 4 to 6 using the prediction model trained with B-spline were 0.81 ± 0.07/0.81 ± 0.04 (week 4), 0.79 ± 0.06/0.81 ± 0.05 (week 5) and 0.78 ± 0.06/0.82 ± 0.02 (week 6). The DICE with the Demons model were 0.78 ± 0.08/0.82 ± 0.03 (week 4), 0.77 ± 0.07/0.82 ± 0.04 (week 5) and 0.75 ± 0.07/0.82 ± 0.02 (week 6). The dose volume histogram (DVH) analysis with the predicted accumulated dose showed the feasibility of predicting dose uncertainty due to the PG anatomical changes. The AUC of ART candidate detection with our predictive model was over 0.90. In conclusion, the proposed network was able to predict future anatomical changes and dose uncertainty of PGs with clinically acceptable accuracy, and hence can be readily integrated into the ART workflow.
- 27 November 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (23) , 235011
Predictive dose accumulation for HN adaptive radiotherapy
During radiation therapy (RT) of head and neck (HN) cancer, the shape and volume of the parotid glands (PG) may change significantly, resulting in clinically relevant deviations of delivered dose from the planning dose. Early and accurate longitudinal prediction of PG anatomical changes during the RT can be valuable to inform decisions on plan adaptation. We developed a deep neural network for longitudinal predictions using the displacement fields (DFs) between the planning computed tomography (pCT) and weekly cone beam computed tomography (CBCT). Sixty-three HN patients treated with volumetric modulated arc were retrospectively studied. We calculated DFs between pCT and week 1–3 CBCT by B-spline and Demon deformable image registration (DIR). The resultant DFs were subsequently used as input to our novel network to predict the week 4 to 6 DFs for generating predicted weekly PG contours and weekly dose distributions. For evaluation, we measured dice similarity (DICE), and the uncertainty of accumulated dose. Moreover, we compared the detection accuracies of candidates for adaptive radiotherapy (ART) when the trigger criteria were mean dose difference more than 10%, 7.5%, and 5%, respectively. The DICE of ipsilateral/contralateral PG at week 4 to 6 using the prediction model trained with B-spline were 0.81 ± 0.07/0.81 ± 0.04 (week 4), 0.79 ± 0.06/0.81 ± 0.05 (week 5) and 0.78 ± 0.06/0.82 ± 0.02 (week 6). The DICE with the Demons model were 0.78 ± 0.08/0.82 ± 0.03 (week 4), 0.77 ± 0.07/0.82 ± 0.04 (week 5) and 0.75 ± 0.07/0.82 ± 0.02 (week 6). The dose volume histogram (DVH) analysis with the predicted accumulated dose showed the feasibility of predicting dose uncertainty due to the PG anatomical changes. The AUC of ART candidate detection with our predictive model was over 0.90. In conclusion, the proposed network was able to predict future anatomical changes and dose uncertainty of PGs with clinically acceptable accuracy, and hence can be readily integrated into the ART workflow.
- 27 November 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (23) , 235027
Predicting spatial esophageal changes in a multimodal longitudinal imaging study via a convolutional recurrent neural network
Acute esophagitis (AE) occurs among a significant number of patients with locally advanced lung cancer treated with radiotherapy. Early prediction of AE, indicated by esophageal wall expansion, is critical, as it can facilitate the redesign of treatment plans to reduce radiation-induced esophageal toxicity in an adaptive radiotherapy (ART) workflow. We have developed a novel machine learning framework to predict the patient-specific spatial presentation of the esophagus in the weeks following treatment, using magnetic resonance imaging (MRI)/ cone-beam CT (CBCT) scans acquired earlier in the 6 week radiotherapy course. Our algorithm captures the response patterns of the esophagus to radiation on a patch level, using a convolutional neural network. A recurrence neural network then parses the evolutionary patterns of the selected features in the time series, and produces a predicted esophagus-or-not label for each individual patch over future weeks. Finally, the esophagus is reconstructed, using all the predicted labels. The algorithm is trained and validated by means of ∼ 250 000 patches taken from MRI scans acquired weekly from a variety of patients, and tested using both weekly MRI and CBCT scans under a leave-one-patient-out scheme. In addition, our approach is externally validated using a publicly available dataset (Hugo 2017). Using the first three weekly scans, the algorithm can predict the condition of the esophagus over the succeeding 3 weeks with a Dice coefficient of 0.83 ± 0.04, estimate esophagus volume highly (0.98), correlated with the actual volume, using our institutional MRI/CBCT data. When evaluated using the external weekly CBCT data, the averaged Dice coefficient is 0.89 ± 0.03. Our novel algorithm may prove useful in enabling radiation oncologists to monitor and detect AE in its early stages, and could potentially play an important role in the ART decision-making process.
- 27 November 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (23) , 235027
Predicting spatial esophageal changes in a multimodal longitudinal imaging study via a convolutional recurrent neural network
Acute esophagitis (AE) occurs among a significant number of patients with locally advanced lung cancer treated with radiotherapy. Early prediction of AE, indicated by esophageal wall expansion, is critical, as it can facilitate the redesign of treatment plans to reduce radiation-induced esophageal toxicity in an adaptive radiotherapy (ART) workflow. We have developed a novel machine learning framework to predict the patient-specific spatial presentation of the esophagus in the weeks following treatment, using magnetic resonance imaging (MRI)/ cone-beam CT (CBCT) scans acquired earlier in the 6 week radiotherapy course. Our algorithm captures the response patterns of the esophagus to radiation on a patch level, using a convolutional neural network. A recurrence neural network then parses the evolutionary patterns of the selected features in the time series, and produces a predicted esophagus-or-not label for each individual patch over future weeks. Finally, the esophagus is reconstructed, using all the predicted labels. The algorithm is trained and validated by means of ∼ 250 000 patches taken from MRI scans acquired weekly from a variety of patients, and tested using both weekly MRI and CBCT scans under a leave-one-patient-out scheme. In addition, our approach is externally validated using a publicly available dataset (Hugo 2017). Using the first three weekly scans, the algorithm can predict the condition of the esophagus over the succeeding 3 weeks with a Dice coefficient of 0.83 ± 0.04, estimate esophagus volume highly (0.98), correlated with the actual volume, using our institutional MRI/CBCT data. When evaluated using the external weekly CBCT data, the averaged Dice coefficient is 0.89 ± 0.03. Our novel algorithm may prove useful in enabling radiation oncologists to monitor and detect AE in its early stages, and could potentially play an important role in the ART decision-making process.
- 3 January 2020
- Published by Wiley in Medical Physics
- Vol. 47 (3) , 1161-1166
Technical Note: 3D localization of lung tumors on cone beam CT projections via a convolutional recurrent neural network
Purpose: To design a convolutional recurrent neural network (CRNN) that calculates three‐dimensional (3D) positions of lung tumors from continuously acquired cone beam computed tomography (CBCT) projections, and facilitates the sorting and reconstruction of 4D‐CBCT images.Method: Under an IRB‐approved clinical lung protocol, kilovoltage (kV) projections of the setup CBCT were collected in free‐breathing. Concurrently, an electromagnetic signal‐guided system recorded motion traces of three transponders implanted in or near the tumor. Convolutional recurrent neural network was designed to utilize a convolutional neural network (CNN) for extracting relevant features of the kV projections around the tumor, followed by a recurrent neural network for analyzing the temporal patterns of the moving features. Convolutional recurrent neural network was trained on the simultaneously collected kV projections and motion traces, subsequently utilized to calculate motion traces solely based on the continuous feed of kV projections. To enhance performance, CRNN was also facilitated by frequent calibrations (e.g., at 10° gantry rotation intervals) derived from cross‐correlation‐based registrations between kV projections and templates created from the planning 4DCT. Convolutional recurrent neural network was validated on a leave‐one‐out strategy using data from 11 lung patients, including 5500 kV images. The root‐mean‐square error between the CRNN and motion traces was calculated to evaluate the localization accuracy.Result: Three‐dimensional displacement around the simulation position shown in the Calypso traces was 3.4 ± 1.7 mm. Using motion traces as ground truth, the 3D localization error of CRNN with calibrations was 1.3 ± 1.4 mm. CRNN had a success rate of 86 ± 8% in determining whether the motion was within a 3D displacement window of 2 mm. The latency was 20 ms when CRNN ran on a high‐performance computer cluster.Conclusions: CRNN is able to provide accurate localization of lung tumors with aid from frequent recalibrations using the conventional cross‐correlation‐based registration approach, and has the potential to remove reliance on the implanted fiducials.
- 3 January 2020
- Published by Wiley in Medical Physics
- Vol. 47 (3) , 1161-1166
Technical Note: 3D localization of lung tumors on cone beam CT projections via a convolutional recurrent neural network
Purpose: To design a convolutional recurrent neural network (CRNN) that calculates three‐dimensional (3D) positions of lung tumors from continuously acquired cone beam computed tomography (CBCT) projections, and facilitates the sorting and reconstruction of 4D‐CBCT images.Method: Under an IRB‐approved clinical lung protocol, kilovoltage (kV) projections of the setup CBCT were collected in free‐breathing. Concurrently, an electromagnetic signal‐guided system recorded motion traces of three transponders implanted in or near the tumor. Convolutional recurrent neural network was designed to utilize a convolutional neural network (CNN) for extracting relevant features of the kV projections around the tumor, followed by a recurrent neural network for analyzing the temporal patterns of the moving features. Convolutional recurrent neural network was trained on the simultaneously collected kV projections and motion traces, subsequently utilized to calculate motion traces solely based on the continuous feed of kV projections. To enhance performance, CRNN was also facilitated by frequent calibrations (e.g., at 10° gantry rotation intervals) derived from cross‐correlation‐based registrations between kV projections and templates created from the planning 4DCT. Convolutional recurrent neural network was validated on a leave‐one‐out strategy using data from 11 lung patients, including 5500 kV images. The root‐mean‐square error between the CRNN and motion traces was calculated to evaluate the localization accuracy.Result: Three‐dimensional displacement around the simulation position shown in the Calypso traces was 3.4 ± 1.7 mm. Using motion traces as ground truth, the 3D localization error of CRNN with calibrations was 1.3 ± 1.4 mm. CRNN had a success rate of 86 ± 8% in determining whether the motion was within a 3D displacement window of 2 mm. The latency was 20 ms when CRNN ran on a high‐performance computer cluster.Conclusions: CRNN is able to provide accurate localization of lung tumors with aid from frequent recalibrations using the conventional cross‐correlation‐based registration approach, and has the potential to remove reliance on the implanted fiducials.