Amir Asgharzadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amir Asgharzadeh has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Michael Raupach
Institute of Building Materials Research, RWTH Aachen University, 52062 Aachen, Germany
4 shared publications Michael Raupach
Professor, Institute of Building Materials Research, Aachen, Germany
3 shared publications- Detlef Koch
Koch GmbH, Hagener Str. 87, 57223 Kreuztal
1 shared publication - Kenji Reichling
RWTH Aachen University
1 shared publication - Majid Mahjoori
Koch GmbH, Hagener Str. 87, 57223 Kreuztal
1 shared publication
Latest Publications
- 1 April 2020
- Published by Emerald Publishing in Magazine of Concrete Research
- Vol. 72 (8) , 422-431
Durability of impregnated carbon textiles in mortar as cathodic protection anodes
Current research focuses on the use of carbon (C) textiles as cathodic protection (CP) anodes. Carbon fibres are of particular interest due to their excellent mechanical properties. However, the influence of anodic polarisation on the durability of carbon anodes is still not sufficiently understood. In previous works, the durability of carbon anodes was examined by experimental investigations in saturated calcium hydroxide (Ca(OH)2) solution. In this work, various anodes (carbon textiles with different impregnations, as well as mixed-metal-oxide-coated titanium (Ti)) were investigated after embedding in mortar. The type of mortar as well as the environmental conditions were varied in order to represent diverse conditions. Potentiostatic polarisation was implemented for 8 months. Results of this work show that CP with impregnated carbon textiles is, at least under the investigated conditions, possible.
- 1 April 2020
- Published by Emerald Publishing in Magazine of Concrete Research
- Vol. 72 (8) , 422-431
Durability of impregnated carbon textiles in mortar as cathodic protection anodes
Current research focuses on the use of carbon (C) textiles as cathodic protection (CP) anodes. Carbon fibres are of particular interest due to their excellent mechanical properties. However, the influence of anodic polarisation on the durability of carbon anodes is still not sufficiently understood. In previous works, the durability of carbon anodes was examined by experimental investigations in saturated calcium hydroxide (Ca(OH)2) solution. In this work, various anodes (carbon textiles with different impregnations, as well as mixed-metal-oxide-coated titanium (Ti)) were investigated after embedding in mortar. The type of mortar as well as the environmental conditions were varied in order to represent diverse conditions. Potentiostatic polarisation was implemented for 8 months. Results of this work show that CP with impregnated carbon textiles is, at least under the investigated conditions, possible.
- Open Access
- 29 December 2018
- Published by MDPI AG in Applied Sciences
- Vol. 9 (1) , 110
Damage Mechanisms of Polymer Impregnated Carbon Textiles Used as Anode Material for Cathodic Protection
Carbon textiles as anode material for cathodic corrosion protection (CP) have been used in several reinforced steel structures. However, experience with durability is limited. To date, various influencing factors have been discovered and systematic tests on different carbon textiles with different impregnation materials in various environmental media have been carried out and considered the degradation of the impregnation materials. In this work the boundary potentials are determined at which the impregnation and sizing is destroyed under anodic polarization and the damage mechanisms are described.
- 29 December 2018
- Published by MDPI AG in Applied Sciences
- Vol. 9 (1) , 110
Open AccessDamage Mechanisms of Polymer Impregnated Carbon Textiles Used as Anode Material for Cathodic Protection
Carbon textiles as anode material for cathodic corrosion protection (CP) have been used in several reinforced steel structures. However, experience with durability is limited. To date, various influencing factors have been discovered and systematic tests on different carbon textiles with different impregnation materials in various environmental media have been carried out and considered the degradation of the impregnation materials. In this work the boundary potentials are determined at which the impregnation and sizing is destroyed under anodic polarization and the damage mechanisms are described.
- Open Access
- 31 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 199, 11015
Tensile strength of carbon rovings impregnated with different materials under anodic polarization
Carbon textiles are used more and more as reinforcement in concrete structures. Due to their high durability the concrete covers can be extremely thin compared to traditional steel reinforced concrete, resulting in the possibility to build very thin elements with excellent performance. To improve the properties of the carbon textiles, the rovings are normally impregnated with different types of polymers. Additionally to the use as reinforcement, carbon textiles can also be used as anodes for cathodic protection. However, while first tests have shown, that impregnated carbon rovings are suitable to be used as CP-anodes, it is still not clear under which conditions the new types of anodes are stable or when they start to dissolve. This paper describes investigations on the influence of an anodic polarisation on the tensile strength of different types of impregnated carbon rovings.
- 31 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 199, 11015
Open AccessTensile strength of carbon rovings impregnated with different materials under anodic polarization
Carbon textiles are used more and more as reinforcement in concrete structures. Due to their high durability the concrete covers can be extremely thin compared to traditional steel reinforced concrete, resulting in the possibility to build very thin elements with excellent performance. To improve the properties of the carbon textiles, the rovings are normally impregnated with different types of polymers. Additionally to the use as reinforcement, carbon textiles can also be used as anodes for cathodic protection. However, while first tests have shown, that impregnated carbon rovings are suitable to be used as CP-anodes, it is still not clear under which conditions the new types of anodes are stable or when they start to dissolve. This paper describes investigations on the influence of an anodic polarisation on the tensile strength of different types of impregnated carbon rovings.
- 15 September 2018
- Published by Springer Nature in RILEM Bookseries
- p. 143-158
Development of a Test Method for the Durability of Carbon Textiles Under Anodic Polarisation
- 15 September 2018
- Published by Springer Nature in RILEM Bookseries
- p. 143-158
Development of a Test Method for the Durability of Carbon Textiles Under Anodic Polarisation
- 4 September 2018
- Published by Wiley in Materials and Corrosion
- Vol. 70 (2) , 345-356
Durability behavior of polymer impregnated carbon textiles in alkaline solution as CP anode
Cathodic corrosion protection (CP) is a cost‐effective option for maintenance of concrete structures. CP is an electrochemical method that can be used to reduce the corrosion rate to an acceptable level. Thus, service life of reinforced concrete can be increased considerably. In this work, carbon textiles with varying polymer impregnations, cross sections, and mesh widths have been used as CP anodes and have been tested for their durability. The main goal of this research is to determine the behavior of carbon textile under permanent anodic polarization while stored in saturated calcium hydroxide solution. The outcome will serve as a basis for further investigations in which textiles will be permanently polarized and tested after embedding in mortar.
- 4 September 2018
- Published by Wiley in Materials and Corrosion
- Vol. 70 (2) , 345-356
Durability behavior of polymer impregnated carbon textiles in alkaline solution as CP anode
Cathodic corrosion protection (CP) is a cost‐effective option for maintenance of concrete structures. CP is an electrochemical method that can be used to reduce the corrosion rate to an acceptable level. Thus, service life of reinforced concrete can be increased considerably. In this work, carbon textiles with varying polymer impregnations, cross sections, and mesh widths have been used as CP anodes and have been tested for their durability. The main goal of this research is to determine the behavior of carbon textile under permanent anodic polarization while stored in saturated calcium hydroxide solution. The outcome will serve as a basis for further investigations in which textiles will be permanently polarized and tested after embedding in mortar.
- 18 January 2016
- Published by Wiley in Bautechnik
- Vol. 93 (3) , 185-191
Kathodischer Korrosionsschutz für Parkbauten mit carbontextilienbewehrtem Spezialmörtel
- 18 January 2016
- Published by Wiley in Bautechnik
- Vol. 93 (3) , 185-191
Kathodischer Korrosionsschutz für Parkbauten mit carbontextilienbewehrtem Spezialmörtel
- 3 November 2014
- Published by Wiley in Bautechnik
- Vol. 91 (11) , 822-827
Neuer Ansatz zur Bestimmung des elektrischen Betonwiderstands bei vorhandener Bewehrung
Die zuverlässige Bestimmung des elektrischen Widerstands von Beton, der mit verschiedenen dauerhaftigkeitsrelevanten Parametern korreliert, stellt sich am Bauwerk derzeit als große Herausforderung dar. Hierbei kommt üblicherweise das WENNER‐Verfahren zum Einsatz, das aber aufgrund der Heterogenität von Stahlbeton, z. B. infolge Bewehrung und Feuchteunterschieden, zu Fehlinterpretationen führen kann.Um der Heterogenität Rechnung zu tragen, wird ein neues Messverfahren angewendet, um die Verteilung des elektrischen Betonwiderstands im Beton zu ermitteln. Hierzu kommt die in der Geophysik entwickelte elektrische Widerstandstomografie zum Einsatz. Um zuverlässige Ergebnisse zu erzielen, muss das Verfahren an die Gegebenheiten von Stahlbeton angepasst werden. Zudem wird u. a. die bekannte WENNER‐Elektrodenkonfiguration mit der Dipol‐Dipol‐Konfiguration verglichen und die Anwendbarkeit des Verfahrens an Stahlbetonprüfkörpern untersucht. Die Untersuchungsergebnisse zeigen, dass das Verfahren an Stahlbeton anwendbar ist, wenn die Lage der Bewehrung und Randeffekte an der Betonoberfläche berücksichtigt werden.Novel approach for determining the electrical resistivity of reinforced concreteThe electrical resistivity of concrete correlates with different durability related parameters. Due to the heterogeneity of reinforced concrete a reliable determination of the concrete resistivity at a structure is a challenging objective. The application of a WENNER probe in the area of reinforcement bars or moisture gradients can lead to misinterpretations.In order to counteract the influence of heterogeneities the Electrical Resistivity Tomography, developed in geophysics, is applied to determine the distribution of the electrical resistivity in concrete elements. The method is adapted to the demands of reinforced concrete structures. The studies focus on a comparison between the WENNER electrode configuration, already known in civil engineering, and the dipole‐dipole electrode configuration and highlight the applicability for reinforced concrete elements. The results show that the method is applicable on reinforced concrete if the position of the reinforcement as well as boundary effects are considered within the evaluation.
- 3 November 2014
- Published by Wiley in Bautechnik
- Vol. 91 (11) , 822-827
Neuer Ansatz zur Bestimmung des elektrischen Betonwiderstands bei vorhandener Bewehrung
Die zuverlässige Bestimmung des elektrischen Widerstands von Beton, der mit verschiedenen dauerhaftigkeitsrelevanten Parametern korreliert, stellt sich am Bauwerk derzeit als große Herausforderung dar. Hierbei kommt üblicherweise das WENNER‐Verfahren zum Einsatz, das aber aufgrund der Heterogenität von Stahlbeton, z. B. infolge Bewehrung und Feuchteunterschieden, zu Fehlinterpretationen führen kann.Um der Heterogenität Rechnung zu tragen, wird ein neues Messverfahren angewendet, um die Verteilung des elektrischen Betonwiderstands im Beton zu ermitteln. Hierzu kommt die in der Geophysik entwickelte elektrische Widerstandstomografie zum Einsatz. Um zuverlässige Ergebnisse zu erzielen, muss das Verfahren an die Gegebenheiten von Stahlbeton angepasst werden. Zudem wird u. a. die bekannte WENNER‐Elektrodenkonfiguration mit der Dipol‐Dipol‐Konfiguration verglichen und die Anwendbarkeit des Verfahrens an Stahlbetonprüfkörpern untersucht. Die Untersuchungsergebnisse zeigen, dass das Verfahren an Stahlbeton anwendbar ist, wenn die Lage der Bewehrung und Randeffekte an der Betonoberfläche berücksichtigt werden.Novel approach for determining the electrical resistivity of reinforced concreteThe electrical resistivity of concrete correlates with different durability related parameters. Due to the heterogeneity of reinforced concrete a reliable determination of the concrete resistivity at a structure is a challenging objective. The application of a WENNER probe in the area of reinforcement bars or moisture gradients can lead to misinterpretations.In order to counteract the influence of heterogeneities the Electrical Resistivity Tomography, developed in geophysics, is applied to determine the distribution of the electrical resistivity in concrete elements. The method is adapted to the demands of reinforced concrete structures. The studies focus on a comparison between the WENNER electrode configuration, already known in civil engineering, and the dipole‐dipole electrode configuration and highlight the applicability for reinforced concrete elements. The results show that the method is applicable on reinforced concrete if the position of the reinforcement as well as boundary effects are considered within the evaluation.