Tanping Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tanping Li has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Guang Jia
School of Computer Science and Technology Xidian University Xi'an Shaanxi China
6 shared publications - Jie Tian
Beihang University
4 shared publications Xiaofang Wang
School of Physics, Xidian University, Xi’an 710071, People’s Republic of China
4 shared publications- Hui Hui
Chinese Academy of Sciences
3 shared publications - Qiguang Miao
Xidian University
3 shared publications Chenxing Hu
School of Computer Science and Technology Xidian University Xi'an Shaanxi China
2 shared publications
Latest Publications
- 6 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (14)
Optical sectioning lattice structured illumination microscopy (OS-LSIM)
Optical sectioning structured illumination microscopy (OS-SIM) is a high-speed, minimally invasive, three-dimensional imaging microscopic technique, playing an important role in life science. However, OS-SIM is unable to achieve optical sectioning and isotropic super-resolution simultaneously. To tackle this drawback, we propose and demonstrate herein optical sectioning lattice structured illumination microscopy (OS-LSIM). This method utilizes a digital micro-mirror device to generate two-dimensional lattice patterns and a lock-in based reconstruction algorithm to realize both optical sectioning and spatial resolution enhancement. OS-LSIM features an axial resolution (optical sectioning strength) of 688 ± 16 nm and a lateral resolution improvement factor of 1.79 compared to conventional wide-field microscopy. We anticipate that OS-LSIM will open new avenues for the study of cellular dynamics in life science.
- 6 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (14)
Optical sectioning lattice structured illumination microscopy (OS-LSIM)
Optical sectioning structured illumination microscopy (OS-SIM) is a high-speed, minimally invasive, three-dimensional imaging microscopic technique, playing an important role in life science. However, OS-SIM is unable to achieve optical sectioning and isotropic super-resolution simultaneously. To tackle this drawback, we propose and demonstrate herein optical sectioning lattice structured illumination microscopy (OS-LSIM). This method utilizes a digital micro-mirror device to generate two-dimensional lattice patterns and a lock-in based reconstruction algorithm to realize both optical sectioning and spatial resolution enhancement. OS-LSIM features an axial resolution (optical sectioning strength) of 688 ± 16 nm and a lateral resolution improvement factor of 1.79 compared to conventional wide-field microscopy. We anticipate that OS-LSIM will open new avenues for the study of cellular dynamics in life science.
- 13 December 2025
- Published by Wiley in Medical Physics
- Vol. 52 (12) , e70188
STimulated emission depletion (STED) magnetic particle imaging
Background: Magnetic particle imaging (MPI) is an in vivo method for detecting magnetic nanoparticles for cell tracking and molecular target imaging. Recently developed human‐sized MPI scanners allow a spatial resolution of only 5–10 mm. High‐resolution MPI is required to precisely locate the magnetic nanoparticles in living organisms. Purpose: This study proposed a high‐resolution imaging method by introducing the STimulated Emission Depletion (STED) fluorescence microscopy principle via a donut‐shaped point spread function (PSF). Methods: We searched for the donut focal spot by adding a direct current offset stimulation magnetic field in the direction of the excitation field and receiver coil in MPI. When the offset stimulation field is greater than the excitation field amplitude, a donut‐shaped focal spot can be formed and the donut radius increases with the offset field amplitude. The formation of the donut focal spot was theoretically evaluated, and the center signal of the donut focal spot was depleted with a strict explanation. The point‐source phantom was experimentally imaged on a field‐free‐point‐based MPI scanner and exhibited a donut‐shaped line profile under a large offset stimulation field. The phantom images were simulated on a field‐free‐line‐based MPI scanner to generate donut‐shaped PSFs and images. Results: By applying an optimized STED factor in the subtraction of the donut PSF from the regular Gaussian PSF, a much smaller PSF could be obtained for deconvolution‐based image reconstruction. The reconstructed images exhibited sub‐millimeter resolution, small root mean square error, high peak signal‐to‐noise ratio, and high structural similarity index. Conclusion: The donut‐shaped PSF obtained using the STED imaging method can be used to improve the MPI resolution by breaking the Langevin magnetization barrier.
- 13 December 2025
- Published by Wiley in Medical Physics
- Vol. 52 (12) , e70188
STimulated emission depletion (STED) magnetic particle imaging
Background: Magnetic particle imaging (MPI) is an in vivo method for detecting magnetic nanoparticles for cell tracking and molecular target imaging. Recently developed human‐sized MPI scanners allow a spatial resolution of only 5–10 mm. High‐resolution MPI is required to precisely locate the magnetic nanoparticles in living organisms. Purpose: This study proposed a high‐resolution imaging method by introducing the STimulated Emission Depletion (STED) fluorescence microscopy principle via a donut‐shaped point spread function (PSF). Methods: We searched for the donut focal spot by adding a direct current offset stimulation magnetic field in the direction of the excitation field and receiver coil in MPI. When the offset stimulation field is greater than the excitation field amplitude, a donut‐shaped focal spot can be formed and the donut radius increases with the offset field amplitude. The formation of the donut focal spot was theoretically evaluated, and the center signal of the donut focal spot was depleted with a strict explanation. The point‐source phantom was experimentally imaged on a field‐free‐point‐based MPI scanner and exhibited a donut‐shaped line profile under a large offset stimulation field. The phantom images were simulated on a field‐free‐line‐based MPI scanner to generate donut‐shaped PSFs and images. Results: By applying an optimized STED factor in the subtraction of the donut PSF from the regular Gaussian PSF, a much smaller PSF could be obtained for deconvolution‐based image reconstruction. The reconstructed images exhibited sub‐millimeter resolution, small root mean square error, high peak signal‐to‐noise ratio, and high structural similarity index. Conclusion: The donut‐shaped PSF obtained using the STED imaging method can be used to improve the MPI resolution by breaking the Langevin magnetization barrier.
- Open Access
Stimulated Emission Depletion (STED) Magnetic Particle Imaging
Magnetic particle imaging (MPI) is an in-vivo imaging method to detect magnetic nanoparticles for blood vessel imaging and molecular target imaging. Compared with conventional molecular imaging devices (such as nuclear medicine imaging PET and SPECT), magnetic nanoparticles have longer storage periods than radionuclides without ionizing radiation. MPI has higher detection sensitivity compared with MRI. To accurately locate molecular probes in living organisms, high-resolution images are needed to meet the requirements of precision medicine. The spatial resolution of the latest domestic and international MPI equipment is 1-6 mm and has not yet met the requirements of medical imaging detection. We previously studied the spatial encoding technology based on pulsed square wave stimulation, which significantly improved the image resolution along the field free line (FFL) direction. This study proposes an innovative idea of high-resolution MPI based on stimulated emission depletion (STED) of magnetic nanoparticle signals. The stimulated emission was implemented by using cosine stimulation on FFL-based MPI scanner systems. The STED signal was generated by adding an offset magnetic field parallel to the FFL, which may form a donut-shaped focal spot or a regular Gaussian focal spot depending on the offset field strength. Focal spot modulation techniques and deconvolution algorithms were developed to improve image resolution.
Open AccessStimulated Emission Depletion (STED) Magnetic Particle Imaging
Magnetic particle imaging (MPI) is an in-vivo imaging method to detect magnetic nanoparticles for blood vessel imaging and molecular target imaging. Compared with conventional molecular imaging devices (such as nuclear medicine imaging PET and SPECT), magnetic nanoparticles have longer storage periods than radionuclides without ionizing radiation. MPI has higher detection sensitivity compared with MRI. To accurately locate molecular probes in living organisms, high-resolution images are needed to meet the requirements of precision medicine. The spatial resolution of the latest domestic and international MPI equipment is 1-6 mm and has not yet met the requirements of medical imaging detection. We previously studied the spatial encoding technology based on pulsed square wave stimulation, which significantly improved the image resolution along the field free line (FFL) direction. This study proposes an innovative idea of high-resolution MPI based on stimulated emission depletion (STED) of magnetic nanoparticle signals. The stimulated emission was implemented by using cosine stimulation on FFL-based MPI scanner systems. The STED signal was generated by adding an offset magnetic field parallel to the FFL, which may form a donut-shaped focal spot or a regular Gaussian focal spot depending on the offset field strength. Focal spot modulation techniques and deconvolution algorithms were developed to improve image resolution.
- 9 June 2023
- Published by Wiley in Medical Physics
- Vol. 50 (7) , 4651-4663
Relaxation spectral analysis in multi‐contrast vascular magnetic particle imaging
Background: Magnetic nanoparticles (MNPs) are used as tracers without ionizing radiation in vascular imaging, molecular imaging, and neuroimaging. The relaxation mechanisms of magnetization in response to excitation magnetic fields are important features of MNPs. The basic relaxation mechanisms include internal rotation (Néel relaxation) and external physical rotation (Brownian relaxation). Accurate measurement of these relaxation times may provide high sensitivity for predicting MNP types and viscosity‐based hydrodynamic states. It is challenging to separately measure the Néel and Brownian relaxation components using sinusoidal excitation in conventional MPI.Purpose: We developed a multi‐exponential relaxation spectral analysis method to separately measure the Néel and Brownian relaxation times in the magnetization recovery process in pulsed vascular MPI.Methods: Synomag‐D samples with different viscosities were excited using pulsed excitation in a trapezoidal‐waveform relaxometer. The samples were excited at different field amplitudes ranging from 0.5 to 10 mT at intervals of 0.5 mT. The inverse Laplace transform‐based spectral analysis of the relaxation‐induced decay signal in the field‐flat phase was performed by using PDCO, a primal‐dual interior method for convex objectives. Néel and Brownian relaxation peaks were elucidated and measured on samples with various glycerol and gelatin concentrations. The sensitivity of viscosity prediction of the decoupled relaxation times was evaluated. A digital vascular phantom was designed to mimic a plaque with viscous MNPs and a catheter with immobilized MNPs. Spectral imaging of the digital vascular phantom was simulated by combining a field‐free point with homogeneous pulsed excitation. The relationship between the Brownian relaxation time from different tissues and the number of periods for signal averages was evaluated for a scan time estimation in the simulation.Results: The relaxation spectra of synomag‐D samples with different viscosity levels exhibited two relaxation time peaks. The Brownian relaxation time had a positive linear relationship with the viscosity in the range 0.9 to 3.2 mPa · s. When the viscosity was >3.2 mPa · s, the Brownian relaxation time saturated and did not change with increasing viscosity. The Néel relaxation time decreased slightly with an increase in the viscosity. The Néel relaxation time exhibited a similar saturation effect when the viscosity level was >3.2 mPa · s for all field amplitudes. The sensitivity of the Brownian relaxation time increased with the field amplitude and was maximized at approximately 4.5 mT. The plaque and catheter regions were differentiated from the vessel region in the simulated Brownian relaxation time map. The simulation results show that the Néel relaxation time was 8.33±0.09 μs in the plaque region, 8.30±0.08 μs in the catheter region, and 8.46±0.11 μs in the vessel region. The Brownian relaxation time was 36.60±2.31 μs in the plaque region, 30.17±1.24 μs in the catheter region, and 31.21±1.53 μs in the vessel region. If we used 20 excitation periods for image acquisition in the simulation, the total scan time of the digital phantom was approximately 100 s.Conclusion: Quantitative assessment of the Néel and Brownian relaxation times through inverse Laplace transform‐based spectral analysis in pulsed excitation, highlighting their potential for use in multi‐contrast vascular MPI.
- 9 June 2023
- Published by Wiley in Medical Physics
- Vol. 50 (7) , 4651-4663
Relaxation spectral analysis in multi‐contrast vascular magnetic particle imaging
Background: Magnetic nanoparticles (MNPs) are used as tracers without ionizing radiation in vascular imaging, molecular imaging, and neuroimaging. The relaxation mechanisms of magnetization in response to excitation magnetic fields are important features of MNPs. The basic relaxation mechanisms include internal rotation (Néel relaxation) and external physical rotation (Brownian relaxation). Accurate measurement of these relaxation times may provide high sensitivity for predicting MNP types and viscosity‐based hydrodynamic states. It is challenging to separately measure the Néel and Brownian relaxation components using sinusoidal excitation in conventional MPI.Purpose: We developed a multi‐exponential relaxation spectral analysis method to separately measure the Néel and Brownian relaxation times in the magnetization recovery process in pulsed vascular MPI.Methods: Synomag‐D samples with different viscosities were excited using pulsed excitation in a trapezoidal‐waveform relaxometer. The samples were excited at different field amplitudes ranging from 0.5 to 10 mT at intervals of 0.5 mT. The inverse Laplace transform‐based spectral analysis of the relaxation‐induced decay signal in the field‐flat phase was performed by using PDCO, a primal‐dual interior method for convex objectives. Néel and Brownian relaxation peaks were elucidated and measured on samples with various glycerol and gelatin concentrations. The sensitivity of viscosity prediction of the decoupled relaxation times was evaluated. A digital vascular phantom was designed to mimic a plaque with viscous MNPs and a catheter with immobilized MNPs. Spectral imaging of the digital vascular phantom was simulated by combining a field‐free point with homogeneous pulsed excitation. The relationship between the Brownian relaxation time from different tissues and the number of periods for signal averages was evaluated for a scan time estimation in the simulation.Results: The relaxation spectra of synomag‐D samples with different viscosity levels exhibited two relaxation time peaks. The Brownian relaxation time had a positive linear relationship with the viscosity in the range 0.9 to 3.2 mPa · s. When the viscosity was >3.2 mPa · s, the Brownian relaxation time saturated and did not change with increasing viscosity. The Néel relaxation time decreased slightly with an increase in the viscosity. The Néel relaxation time exhibited a similar saturation effect when the viscosity level was >3.2 mPa · s for all field amplitudes. The sensitivity of the Brownian relaxation time increased with the field amplitude and was maximized at approximately 4.5 mT. The plaque and catheter regions were differentiated from the vessel region in the simulated Brownian relaxation time map. The simulation results show that the Néel relaxation time was 8.33±0.09 μs in the plaque region, 8.30±0.08 μs in the catheter region, and 8.46±0.11 μs in the vessel region. The Brownian relaxation time was 36.60±2.31 μs in the plaque region, 30.17±1.24 μs in the catheter region, and 31.21±1.53 μs in the vessel region. If we used 20 excitation periods for image acquisition in the simulation, the total scan time of the digital phantom was approximately 100 s.Conclusion: Quantitative assessment of the Néel and Brownian relaxation times through inverse Laplace transform‐based spectral analysis in pulsed excitation, highlighting their potential for use in multi‐contrast vascular MPI.
- 7 November 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 126 (45) , 9168-9175
Explicit Projection of Stokes Shifts onto Solvent Motion in an Aqueous Liquid and Linear Response Theory
We investigate the molecular origin of the fluorescence Stokes shift in an aqueous liquid. By examining the speed of energy change, the solvation response function is explicitly projected onto the translational and rotational motions of water molecules for both nonequilibrium relaxation and equilibrium fluctuations. Molecular dynamics simulations of a tryptophan solution show that these two processes have highly consistent dynamics, not only for the total response function but also for the decomposed components in terms of specific molecular movements. We found that the rotational mode governs the relaxation of the Stokes shift, whereas the translational mode contributes non-negligibly with slower dynamics. This consistency implies the similarity of the underlying translational and rotational movements of water molecules as the system is far away from and at equilibrium, supporting the validity of the linear response theory at the molecular level. The decomposition methodology is also applicable to a rigid solvent.
- 7 November 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 126 (45) , 9168-9175
Explicit Projection of Stokes Shifts onto Solvent Motion in an Aqueous Liquid and Linear Response Theory
We investigate the molecular origin of the fluorescence Stokes shift in an aqueous liquid. By examining the speed of energy change, the solvation response function is explicitly projected onto the translational and rotational motions of water molecules for both nonequilibrium relaxation and equilibrium fluctuations. Molecular dynamics simulations of a tryptophan solution show that these two processes have highly consistent dynamics, not only for the total response function but also for the decomposed components in terms of specific molecular movements. We found that the rotational mode governs the relaxation of the Stokes shift, whereas the translational mode contributes non-negligibly with slower dynamics. This consistency implies the similarity of the underlying translational and rotational movements of water molecules as the system is far away from and at equilibrium, supporting the validity of the linear response theory at the molecular level. The decomposition methodology is also applicable to a rigid solvent.
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (12) , 3725-3733
Gradient-Based Pulsed Excitation and Relaxation Encoding in Magnetic Particle Imaging
Magnetic particle imaging (MPI) is a radiation-free vessel- and target-imaging modality that can sensitively detect nanoparticles. A static magnetic gradient field, referred to as a selection field, is required in MPI to provide a field-free region (FFR) for spatial encoding. The image resolution of MPI is closely related to the size of the FFR, which is determined by the selection field gradient amplitude. Because of the limitations of existing gradient coil hardware, the image resolution of MPI cannot satisfy the clinical requirements of human in vivo imaging. Pulsed excitation has been confirmed to improve the image resolution of MPI by breaking down the ’relaxation wall.’ This work proposes the use of a pulsed waveform magnetic gradient from magnetic resonance imaging to further improve the image resolution of MPI. Through alignment of the gradient direction along the field-free line (FFL), each location on the FFL is able to have a unique excitation field strength that generates a specific relaxation-induced decay signal. Through excitation of nanoparticles on the FFL with many gradient profiles, a high-resolution, one-dimensional (1D) image can be reconstructed on the FFL. For larger magnetic nanoparticles, simulation results revealed that a pulsed excitation field with a greater flat portion generates a 1D bar pattern phantom image with a higher correlation and spatial resolution. With parallel FFL and gradient coil movements, high-resolution, two-dimensional (2D) Shepp–Logan phantom and brain vessel maps were reconstructed through repetition of the spatially resolved measurement of magnetic nanoparticles on the FFL.
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (12) , 3725-3733
Gradient-Based Pulsed Excitation and Relaxation Encoding in Magnetic Particle Imaging
Magnetic particle imaging (MPI) is a radiation-free vessel- and target-imaging modality that can sensitively detect nanoparticles. A static magnetic gradient field, referred to as a selection field, is required in MPI to provide a field-free region (FFR) for spatial encoding. The image resolution of MPI is closely related to the size of the FFR, which is determined by the selection field gradient amplitude. Because of the limitations of existing gradient coil hardware, the image resolution of MPI cannot satisfy the clinical requirements of human in vivo imaging. Pulsed excitation has been confirmed to improve the image resolution of MPI by breaking down the ’relaxation wall.’ This work proposes the use of a pulsed waveform magnetic gradient from magnetic resonance imaging to further improve the image resolution of MPI. Through alignment of the gradient direction along the field-free line (FFL), each location on the FFL is able to have a unique excitation field strength that generates a specific relaxation-induced decay signal. Through excitation of nanoparticles on the FFL with many gradient profiles, a high-resolution, one-dimensional (1D) image can be reconstructed on the FFL. For larger magnetic nanoparticles, simulation results revealed that a pulsed excitation field with a greater flat portion generates a 1D bar pattern phantom image with a higher correlation and spatial resolution. With parallel FFL and gradient coil movements, high-resolution, two-dimensional (2D) Shepp–Logan phantom and brain vessel maps were reconstructed through repetition of the spatially resolved measurement of magnetic nanoparticles on the FFL.
- Open Access
- 22 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 33756-33768
Application of U-Net Based Multiparameter Magnetic Resonance Image Fusion in the Diagnosis of Prostate Cancer
Medical image fusion technology has been widely used in clinical practice by doctors to better understand lesion regions through the fusion of multiparametric medical images. This paper proposes an automated fusion method based on a U-Net. Through neural network learning, a weight distribution is generated based on the relationship between the image feature information and the multifocus training target. The MRI image pair of prostate cancer (axial T2-weighted and ADC map) is fused using a strategy based on local similarity and Gaussian pyramid transformation. Experimental results show that the fusion method can enhance the appearance of prostate cancer in terms of both visual quality and objective evaluation.
- 22 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 33756-33768
Open AccessApplication of U-Net Based Multiparameter Magnetic Resonance Image Fusion in the Diagnosis of Prostate Cancer
Medical image fusion technology has been widely used in clinical practice by doctors to better understand lesion regions through the fusion of multiparametric medical images. This paper proposes an automated fusion method based on a U-Net. Through neural network learning, a weight distribution is generated based on the relationship between the image feature information and the multifocus training target. The MRI image pair of prostate cancer (axial T2-weighted and ADC map) is fused using a strategy based on local similarity and Gaussian pyramid transformation. Experimental results show that the fusion method can enhance the appearance of prostate cancer in terms of both visual quality and objective evaluation.
- 27 July 2020
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 16 (6) , 695-702
Development of Radiofrequency Saturation Amplitude-independent Quantitative Markers for Magnetization Transfer MRI of Prostate Cancer
Background: In the United States, prostate cancer has a relatively large impact on men's health. Magnetic resonance imaging (MRI) is useful for the diagnosis and treatment of prostate cancer.Introduction: The purpose of this study was to develop a quantitative marker for use in prostate cancer magnetization transfer (MT) magnetic resonance imaging (MRI) studies that is independent of radiofrequency (RF) saturation amplitude.Methods: Eighteen patients with biopsy-proven prostate cancer were enrolled in this study. MTMRI images were acquired using four RF saturation amplitudes at 33 frequency offsets. ROIs were delineated for the peripheral zone (PZ), central gland (CG), and tumor. Z-spectral data were collected in each region and fit to a three-parameter equation. The three parameters are: the magnitude of the bulk water pool (Aw), the full width at half maximum of the water pool (Gw), and the magnitude of the bound pool (Ab), while, the slopes from the linear regressions of Gw and Ab on RF saturation amplitude (called kAb and kGw) were used as quantitative markers.Results: A pairwise statistically significant difference was found between the PZ and tumor regions for the two saturation amplitude-independent quantitative markers. No pairwise statistically significant differences were found between the CG and tumor regions for any quantitative markers.Conclusion: The significant differences between the values of the two RF saturation amplitudeindependent quantitative markers in the PZ and tumor regions reveal that these markers may be capable of distinguishing healthy PZ tissue from prostate cancer.
- 27 July 2020
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 16 (6) , 695-702
Development of Radiofrequency Saturation Amplitude-independent Quantitative Markers for Magnetization Transfer MRI of Prostate Cancer
Background: In the United States, prostate cancer has a relatively large impact on men's health. Magnetic resonance imaging (MRI) is useful for the diagnosis and treatment of prostate cancer.Introduction: The purpose of this study was to develop a quantitative marker for use in prostate cancer magnetization transfer (MT) magnetic resonance imaging (MRI) studies that is independent of radiofrequency (RF) saturation amplitude.Methods: Eighteen patients with biopsy-proven prostate cancer were enrolled in this study. MTMRI images were acquired using four RF saturation amplitudes at 33 frequency offsets. ROIs were delineated for the peripheral zone (PZ), central gland (CG), and tumor. Z-spectral data were collected in each region and fit to a three-parameter equation. The three parameters are: the magnitude of the bulk water pool (Aw), the full width at half maximum of the water pool (Gw), and the magnitude of the bound pool (Ab), while, the slopes from the linear regressions of Gw and Ab on RF saturation amplitude (called kAb and kGw) were used as quantitative markers.Results: A pairwise statistically significant difference was found between the PZ and tumor regions for the two saturation amplitude-independent quantitative markers. No pairwise statistically significant differences were found between the CG and tumor regions for any quantitative markers.Conclusion: The significant differences between the values of the two RF saturation amplitudeindependent quantitative markers in the PZ and tumor regions reveal that these markers may be capable of distinguishing healthy PZ tissue from prostate cancer.
- Open Access
- 13 May 2020
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 10 (31) , 18348-18354
To unravel the connection between the non-equilibrium and equilibrium solvation dynamics of tryptophan: success and failure of the linear response theory of fluorescence Stokes shift
The connections between the non-equilibrium solvation dynamics upon optical transitions and the system's equilibrium fluctuations are explored in aqueous liquid. Linear response theory correlates time-dependent fluorescence with the equilibrium time correlation functions. In the previous work [T. Li, J. Chem. Theory Comput., 2017, 13, 1867], Stokes shift was explicitly decomposed into the contributions of various order time correlation functions on the excited state surface. Gaussian fluctuations of the solute–solvent interactions validate linear response theory. Correspondingly, the deviation of the Gaussian statistics causes the inefficiency of linear response evaluation. The above mechanism is thoroughly tested in this study. By employing molecular simulations, multiple non-equilibrium processes, not necessarily initiated from the ground state equilibrium minimum, were examined for tryptophan. Both the success and failure of linear response theory are found for this simple system and the mechanism is analyzed. These observations, assisted by the width dynamics, the initial state linear response approach, and the variation of the solvation structures, integrally verify the virtue of the excited state Gaussian statistics on the dynamics of Stokes shift.
- 13 May 2020
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 10 (31) , 18348-18354
Open AccessTo unravel the connection between the non-equilibrium and equilibrium solvation dynamics of tryptophan: success and failure of the linear response theory of fluorescence Stokes shift
The connections between the non-equilibrium solvation dynamics upon optical transitions and the system's equilibrium fluctuations are explored in aqueous liquid. Linear response theory correlates time-dependent fluorescence with the equilibrium time correlation functions. In the previous work [T. Li, J. Chem. Theory Comput., 2017, 13, 1867], Stokes shift was explicitly decomposed into the contributions of various order time correlation functions on the excited state surface. Gaussian fluctuations of the solute–solvent interactions validate linear response theory. Correspondingly, the deviation of the Gaussian statistics causes the inefficiency of linear response evaluation. The above mechanism is thoroughly tested in this study. By employing molecular simulations, multiple non-equilibrium processes, not necessarily initiated from the ground state equilibrium minimum, were examined for tryptophan. Both the success and failure of linear response theory are found for this simple system and the mechanism is analyzed. These observations, assisted by the width dynamics, the initial state linear response approach, and the variation of the solvation structures, integrally verify the virtue of the excited state Gaussian statistics on the dynamics of Stokes shift.
- 26 March 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 124 (17) , 3540-3547
Linear Response Theory for Decomposition Energies of Stokes Shift in Proteins
In aqueous solution, fluorescence Stokes shift experiments monitor the relaxation of the solute-solvent interactions upon photon excitation of the solute chromophore. Linear repose theory (LR) expects the identical dynamics between Stokes shift and system’s spontaneous fluctuations. Whether this identity guarantees the similar dynamics between the nonequilibrated and equilibrium processes for the decomposition energy of Stokes shift, is the main focus of this study. In our previous work [J. Chem. Theory Comput. 2017, 13, 1867-1873], Stokes shift is properly correlated with the various order time correlation functions. As a continuation, its decomposition energy from the subsystem is further represented as the full summation of all the cross time correlation functions between the decomposition energy and the total solute-solvent interaction. Gaussian statistics of the total interactions ensure the same decay rates among the odd orders not only for the time correlation functions, but also the cross time correlation functions, validating LR of Stokes shift and the decompositions respectively. The above mechanism is verified by molecular dynamics simulations in the protein Staphylococcus nuclease, and is robust even as the decomposed energy associated with an individual residue exhibits the typical non-Gaussian properties. Further examinations reveal the consistent molecular motions for a specific residue over the nonequilibrium and equilibrium processes, which are responsible for the nonequilibrium dynamics of the associated decomposed energy. Our results show the appropriateness of LR on the finer molecular scales.
- 26 March 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 124 (17) , 3540-3547
Linear Response Theory for Decomposition Energies of Stokes Shift in Proteins
In aqueous solution, fluorescence Stokes shift experiments monitor the relaxation of the solute-solvent interactions upon photon excitation of the solute chromophore. Linear repose theory (LR) expects the identical dynamics between Stokes shift and system’s spontaneous fluctuations. Whether this identity guarantees the similar dynamics between the nonequilibrated and equilibrium processes for the decomposition energy of Stokes shift, is the main focus of this study. In our previous work [J. Chem. Theory Comput. 2017, 13, 1867-1873], Stokes shift is properly correlated with the various order time correlation functions. As a continuation, its decomposition energy from the subsystem is further represented as the full summation of all the cross time correlation functions between the decomposition energy and the total solute-solvent interaction. Gaussian statistics of the total interactions ensure the same decay rates among the odd orders not only for the time correlation functions, but also the cross time correlation functions, validating LR of Stokes shift and the decompositions respectively. The above mechanism is verified by molecular dynamics simulations in the protein Staphylococcus nuclease, and is robust even as the decomposed energy associated with an individual residue exhibits the typical non-Gaussian properties. Further examinations reveal the consistent molecular motions for a specific residue over the nonequilibrium and equilibrium processes, which are responsible for the nonequilibrium dynamics of the associated decomposed energy. Our results show the appropriateness of LR on the finer molecular scales.