GLGeert Leenders

Geert Leenders

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Geert Leenders has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Safety and efficacy of coronary sinus narrowing in chronic refractory angina: Insights from the RESOURCE study

    by Francesco Ponticelli, Arif A. Khokhar, Geert Leenders, Maayan Konigstein, Carlo Zivelonghi, Pierfrancesco Agostoni, Jan-Peter van Kuijk, Issameddine Ajmi, Steven Lindsay, Matjaž Bunc, et al.


  • Coronary sinus anatomical features: Description and procedural implications during coronary sinus Reducer implantation

    by Adriaan Wilgenhof, Carlo Zivelonghi, Stefan Verheye, Paul Vermeersch, Benjamin Scott, Carl Convens, Leo Timmers, Geert Leenders, Jan Peter Van Kuijk, Pieter Stella, et al.

    Objectives: We hypothesized that some coronary sinus (CS) anatomies allow a more straightforward CS Reducer (CSR) implantation.Background: Recent decades have seen a rise in patients with chronic angina. When complete revascularization and maximal medical therapy fail to reduce symptoms, CSR has become a new therapeutic option.Methods: We identified a classical C‐shape—a near horizontal course of the proximal portion of a circular CS—in a retrospective analysis of 47 CSR implantations and compared the procedural time, fluoroscopic time, contrast use, presence of valves or bifurcations and procedural complications with the non‐C‐shape CS anatomy.Results: We found a significant difference in procedural (20.0 [19.0–24.7] min vs. 24.5 [20.7–51.0] min; p = .028 and fluoroscopic time (9.5 [7.5–14.5] min vs. 11.0 [7.9–30.0] min; p = .016). There was no significant difference in contrast use. The presence of bifurcations or valves along the CS course did not influence the procedural timings.Conclusion: This study is the first systematic evaluation of CS anatomy and its procedural implications. We identified a favorable C‐shape anatomy which allows for a more straightforward implantation. Operators should be aware of the different implications of CS anatomy, their influence on guiding catheter stability and overall procedure complexity.


  • Open Access

    Comparison of the Sapien 3 versus the ACURATE neo valve system: A propensity score analysis

    by Nynke H. Kooistra, Valent M. P. Intan‐Goey, Francesca Ziviello, Geert E. Leenders, Adriaan O. Kraaijeveld, Pieter A. Doevendans, Nicolas M. Van Mieghem, Michiel Voskuil, Pieter R. Stella

    Objectives: To compare the outcomes of transfemoral ACURATE neo (NEO) and Sapien 3 (S3) patients in terms of device success and clinical safety outcomes using a propensity score analysis.Background: Differences in clinical outcomes between the latest‐generation balloon‐expandable S3 and self‐expanding NEO in a “real‐world transfemoral TAVI population” are still unclear.Methods: We compared up to 6 months clinical outcomes using a propensity score analysis (inverse probability of treatment weighting [IPTW]) to account for differences in baseline characteristics.Results: A total of 345 patients underwent transfemoral transcatheter aortic valve implantation (TAVI) with either NEO or S3 at two centers in the Netherlands. Composite device success and early safety endpoints were comparable between NEO and S3 (Device success: IPTW‐adjusted OR: 0.35 [95% CI: 0.12–1.18], and early safety: IPTW‐adjusted OR: 0.51 [95% CI: 0.19–1.38]). Six‐months mortality was 5.3 versus 3.6%, stroke was 2.8 versus 3.3%, and pacemaker rate was 6.1 versus 8.6%, respectively with p = NS. Mean aortic gradient was lower in the NEO group (5.72 ± 2.47 vs. 9.05 ± 3.48; p = <.001), with a comparable rate of moderate or severe paravalvular leak (0 versus 2.1%; p = NS).Conclusions: Device success and clinical safety outcomes were comparable for both valves. Up to 6‐months follow‐up clinical outcomes and mortality rate remained excellent. Mean aortic gradient was lower after ACURATE neo implantation.


  • Efficacy of Coronary Sinus Reducer in Patients With Non-revascularized Chronic Total Occlusions

    by Carlo Zivelonghi, Stefan Verheye, Leo Timmers, Jan Peter van Kuijk, Francesco Giannini, Mirthe Dekker, Max Silvis, Masieh Abawi, Geert Leenders, Friso Kortland, et al.


  • Open Access

    One‐year clinical outcomes of patients treated with polymer‐free amphilimus‐eluting stents or zotarolimus‐eluting stents: A propensity‐score adjusted analysis

    by Rik Rozemeijer, Ivar G. van Muiden, Stefan Koudstaal, Geert E. Leenders, Leo Timmers, Saskia Z. Rittersma, Adriaan O. Kraaijeveld, Pieter A. Doevendans, Michiel Voskuil, Pieter R. Stella

    Background: Polymer‐free amphilimus‐eluting stents (PF‐AES) represent a novel elution‐technology in coronary stenting. We aimed to assess 1‐year clinical outcomes of PF‐AES as compared to latest‐generation permanent polymer zotarolimus‐eluting stents (PP‐ZES) in a real‐world all‐comers setting.Methods: A prospective registry of patients treated with either PF‐AES or PP‐ZES between 2014 and 2016 was conducted. The primary outcome was defined as major adverse cardiac and cerebrovascular events (MACCE), and the secondary outcome was defined as target‐lesion failure (TLF) at 1 year. To account for measured confounders, a propensity‐score adjusted Cox proportional‐hazard model was built to evaluate clinical outcomes.Results: A total of 734 consecutive patients with 1,269 DES implantations were enrolled. The population was characterized by 28% diabetes, 24% ST‐segment elevation myocardial infarction, and a high number of complex lesions (69%). The rate of MACCE was 11.5% for PF‐AES and 13.6% for PP‐ZES, plog‐rank = 0.11. TLF was numerically lower in PF‐AES as compared to PP‐ZES (5.4 vs. 6.1%, plog‐rank = 0.68). After propensity‐score adjustment, PF‐AES showed a trend toward a lower rate of MACCE and a favorable rate of TLF as compared to PP‐ZES (HR 0.70; 95%CI 0.45 to 1.10, P = 0.12; and HR 0.88; 95%CI 0.47 to 1.65, P = 0.68, respectively). Rates of definite ST were low (0.8 vs. 0.3%, plog‐rank = 0.62).Conclusions: Our study suggests that implantation of PF‐AES was safe and effective in real‐world patients, with low‐rates of MACCE and TLF at 1 year. Our data needs to be confirmed by a large trial to evaluate the clinical outcomes of this novel polymer‐free, eluting‐technology used in PF‐AES.