Youngbin Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Youngbin Shin has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Kyung Won Kim
Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
9 shared publications - Yousun Ko
Biomedical Research Center, Asan Institute for Life Sciences, Asan Medical Center, Seoul, Korea
5 shared publications - Yu Sub Sung
Clinical Research Center, Asan Medical Center, Seoul, Korea
4 shared publications - Amy Junghyun Lee
Trial Informatics Image, Clinical Operation Unit, Singapore
3 shared publications - Dong Wook Kim
Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
3 shared publications - Jeongjin Lee
School of Computer Science and Engineering, Soongsil University, Seoul, Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 5 September 2022
- Published by XMLink in Korean Journal of Radiology
- Vol. 23 (11) , 1089-1101
Evolution of Radiological Treatment Response Assessments for Cancer Immunotherapy: From iRECIST to Radiomics and Artificial Intelligence
Kim N, et al. Korean J Radiol. 2022 Nov;23(11):1089-1101. https://doi.org/10.3348/kjr.2022.0225
- 5 September 2022
- Published by XMLink in Korean Journal of Radiology
- Vol. 23 (11) , 1089-1101
Open AccessEvolution of Radiological Treatment Response Assessments for Cancer Immunotherapy: From iRECIST to Radiomics and Artificial Intelligence
Kim N, et al. Korean J Radiol. 2022 Nov;23(11):1089-1101. https://doi.org/10.3348/kjr.2022.0225
- Open Access
- 1 January 2021
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 40 (1) , 126-135
Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
This study evaluated the test-retest repeatability and measurement variability of ultrasonographic shear wave elastography (SWE) for liver stiffness in a rat liver fibrosis model. In 31 Sprague-Dawley rats divided into three groups (high-dose, low-dose, and control), liver fibrosis was induced by intraperitoneal administration of thioacetamide for 8 weeks. A dedicated radiographer performed SWE to measure liver stiffness in kilopascals in two sessions at a 3-day interval. We calculated correlations between liver stiffness and histopathologic results, measurement variability in each session using coefficients of variation (CoVs) and interquartile/median (IQR/M), and test-retest repeatability between both sessions using the repeatability coefficient. Different levels of liver fibrosis in each group were successfully induced in the animal model. The mean liver stiffness values were 8.88±1.48 kPa in the control group, 11.62±1.70 kPa in the low-dose group, and 11.91±1.73 kPa in the high-dose group. The correlation between collagen areas and liver stiffness values was moderate (r=0.6). In all groups, the second session yielded lower CoVs (i.e., more reliable results) for liver stiffness than the first session, suggesting a training effect for the operator. The mean IQR/M values were also lower in the second session than in the first session, which had four outliers (0.21 vs. 0.12, P<0.001). The test-retest repeatability coefficient was 3.75 kPa and decreased to 2.82 kPa after removing the four outliers. The use of ultrasonographic SWE was confirmed to be feasible and repeatable for evaluating liver fibrosis in preclinical trials. Operator training might reduce variability in liver stiffness measurements.
- 1 January 2021
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 40 (1) , 126-135
Open AccessTest-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
This study evaluated the test-retest repeatability and measurement variability of ultrasonographic shear wave elastography (SWE) for liver stiffness in a rat liver fibrosis model. In 31 Sprague-Dawley rats divided into three groups (high-dose, low-dose, and control), liver fibrosis was induced by intraperitoneal administration of thioacetamide for 8 weeks. A dedicated radiographer performed SWE to measure liver stiffness in kilopascals in two sessions at a 3-day interval. We calculated correlations between liver stiffness and histopathologic results, measurement variability in each session using coefficients of variation (CoVs) and interquartile/median (IQR/M), and test-retest repeatability between both sessions using the repeatability coefficient. Different levels of liver fibrosis in each group were successfully induced in the animal model. The mean liver stiffness values were 8.88±1.48 kPa in the control group, 11.62±1.70 kPa in the low-dose group, and 11.91±1.73 kPa in the high-dose group. The correlation between collagen areas and liver stiffness values was moderate (r=0.6). In all groups, the second session yielded lower CoVs (i.e., more reliable results) for liver stiffness than the first session, suggesting a training effect for the operator. The mean IQR/M values were also lower in the second session than in the first session, which had four outliers (0.21 vs. 0.12, P<0.001). The test-retest repeatability coefficient was 3.75 kPa and decreased to 2.82 kPa after removing the four outliers. The use of ultrasonographic SWE was confirmed to be feasible and repeatable for evaluating liver fibrosis in preclinical trials. Operator training might reduce variability in liver stiffness measurements.
- Open Access
- 19 October 2020
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 8 (10) , e23049
Assessment of Myosteatosis on Computed Tomography by Automatic Generation of a Muscle Quality Map Using a Web-Based Toolkit: Feasibility Study
Background: Muscle quality is associated with fatty degeneration or infiltration of the muscle, which may be associated with decreased muscle function and increased disability. Objective: The aim of this study is to evaluate the feasibility of automated quantitative measurements of the skeletal muscle on computed tomography (CT) images to assess normal-attenuation muscle and myosteatosis. Methods: We developed a web-based toolkit to generate a muscle quality map by categorizing muscle components. First, automatic segmentation of the total abdominal muscle area (TAMA), visceral fat area, and subcutaneous fat area was performed using a predeveloped deep learning model on a single axial CT image at the L3 vertebral level. Second, the Hounsfield unit of each pixel in the TAMA was measured and categorized into 3 components: normal-attenuation muscle area (NAMA), low-attenuation muscle area (LAMA), and inter/intramuscular adipose tissue (IMAT) area. The myosteatosis area was derived by adding the LAMA and IMAT area. We tested the feasibility of the toolkit using randomly selected healthy participants, comprising 6 different age groups (20 to 79 years). With stratification by sex, these indices were compared between age groups using 1-way analysis of variance (ANOVA). Correlations between the myosteatosis area or muscle densities and fat areas were analyzed using Pearson correlation coefficient r. Results: A total of 240 healthy participants (135 men and 105 women) with 40 participants per age group were included in the study. In the 1-way ANOVA, the NAMA, LAMA, and IMAT were significantly different between the age groups in both male and female participants (P≤.004), whereas the TAMA showed a significant difference only in male participants (male, P<.001; female, P=.88). The myosteatosis area had a strong negative correlation with muscle densities (r=–0.833 to –0.894), a moderate positive correlation with visceral fat areas (r=0.607 to 0.669), and a weak positive correlation with the subcutaneous fat areas (r=0.305 to 0.441). Conclusions: The automated web-based toolkit is feasible and enables quantitative CT assessment of myosteatosis, which can be a potential quantitative biomarker for evaluating structural and functional changes brought on by aging in the skeletal muscle.
- 19 October 2020
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 8 (10) , e23049
Open AccessAssessment of Myosteatosis on Computed Tomography by Automatic Generation of a Muscle Quality Map Using a Web-Based Toolkit: Feasibility Study
Background: Muscle quality is associated with fatty degeneration or infiltration of the muscle, which may be associated with decreased muscle function and increased disability. Objective: The aim of this study is to evaluate the feasibility of automated quantitative measurements of the skeletal muscle on computed tomography (CT) images to assess normal-attenuation muscle and myosteatosis. Methods: We developed a web-based toolkit to generate a muscle quality map by categorizing muscle components. First, automatic segmentation of the total abdominal muscle area (TAMA), visceral fat area, and subcutaneous fat area was performed using a predeveloped deep learning model on a single axial CT image at the L3 vertebral level. Second, the Hounsfield unit of each pixel in the TAMA was measured and categorized into 3 components: normal-attenuation muscle area (NAMA), low-attenuation muscle area (LAMA), and inter/intramuscular adipose tissue (IMAT) area. The myosteatosis area was derived by adding the LAMA and IMAT area. We tested the feasibility of the toolkit using randomly selected healthy participants, comprising 6 different age groups (20 to 79 years). With stratification by sex, these indices were compared between age groups using 1-way analysis of variance (ANOVA). Correlations between the myosteatosis area or muscle densities and fat areas were analyzed using Pearson correlation coefficient r. Results: A total of 240 healthy participants (135 men and 105 women) with 40 participants per age group were included in the study. In the 1-way ANOVA, the NAMA, LAMA, and IMAT were significantly different between the age groups in both male and female participants (P≤.004), whereas the TAMA showed a significant difference only in male participants (male, P<.001; female, P=.88). The myosteatosis area had a strong negative correlation with muscle densities (r=–0.833 to –0.894), a moderate positive correlation with visceral fat areas (r=0.607 to 0.669), and a weak positive correlation with the subcutaneous fat areas (r=0.305 to 0.441). Conclusions: The automated web-based toolkit is feasible and enables quantitative CT assessment of myosteatosis, which can be a potential quantitative biomarker for evaluating structural and functional changes brought on by aging in the skeletal muscle.
- Open Access
- 30 July 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Assessment of Myosteatosis on Computed Tomography by Automatic Generation of a Muscle Quality Map Using a Web-Based Toolkit: Feasibility Study (Preprint)
BACKGROUND Muscle quality is associated with fatty degeneration or infiltration of the muscle, which may be associated with decreased muscle function and increased disability. OBJECTIVE The aim of this study is to evaluate the feasibility of automated quantitative measurements of the skeletal muscle on computed tomography (CT) images to assess normal-attenuation muscle and myosteatosis. METHODS We developed a web-based toolkit to generate a muscle quality map by categorizing muscle components. First, automatic segmentation of the total abdominal muscle area (TAMA), visceral fat area, and subcutaneous fat area was performed using a predeveloped deep learning model on a single axial CT image at the L3 vertebral level. Second, the Hounsfield unit of each pixel in the TAMA was measured and categorized into 3 components: normal-attenuation muscle area (NAMA), low-attenuation muscle area (LAMA), and inter/intramuscular adipose tissue (IMAT) area. The myosteatosis area was derived by adding the LAMA and IMAT area. We tested the feasibility of the toolkit using randomly selected healthy participants, comprising 6 different age groups (20 to 79 years). With stratification by sex, these indices were compared between age groups using 1-way analysis of variance (ANOVA). Correlations between the myosteatosis area or muscle densities and fat areas were analyzed using Pearson correlation coefficient r. RESULTS A total of 240 healthy participants (135 men and 105 women) with 40 participants per age group were included in the study. In the 1-way ANOVA, the NAMA, LAMA, and IMAT were significantly different between the age groups in both male and female participants (P≤.004), whereas the TAMA showed a significant difference only in male participants (male, P<.001; female, P=.88). The myosteatosis area had a strong negative correlation with muscle densities (r=–0.833 to –0.894), a moderate positive correlation with visceral fat areas (r=0.607 to 0.669), and a weak positive correlation with the subcutaneous fat areas (r=0.305 to 0.441). CONCLUSIONS The automated web-based toolkit is feasible and enables quantitative CT assessment of myosteatosis, which can be a potential quantitative biomarker for evaluating structural and functional changes brought on by aging in the skeletal muscle. CLINICALTRIAL
- 30 July 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAssessment of Myosteatosis on Computed Tomography by Automatic Generation of a Muscle Quality Map Using a Web-Based Toolkit: Feasibility Study (Preprint)
BACKGROUND Muscle quality is associated with fatty degeneration or infiltration of the muscle, which may be associated with decreased muscle function and increased disability. OBJECTIVE The aim of this study is to evaluate the feasibility of automated quantitative measurements of the skeletal muscle on computed tomography (CT) images to assess normal-attenuation muscle and myosteatosis. METHODS We developed a web-based toolkit to generate a muscle quality map by categorizing muscle components. First, automatic segmentation of the total abdominal muscle area (TAMA), visceral fat area, and subcutaneous fat area was performed using a predeveloped deep learning model on a single axial CT image at the L3 vertebral level. Second, the Hounsfield unit of each pixel in the TAMA was measured and categorized into 3 components: normal-attenuation muscle area (NAMA), low-attenuation muscle area (LAMA), and inter/intramuscular adipose tissue (IMAT) area. The myosteatosis area was derived by adding the LAMA and IMAT area. We tested the feasibility of the toolkit using randomly selected healthy participants, comprising 6 different age groups (20 to 79 years). With stratification by sex, these indices were compared between age groups using 1-way analysis of variance (ANOVA). Correlations between the myosteatosis area or muscle densities and fat areas were analyzed using Pearson correlation coefficient r. RESULTS A total of 240 healthy participants (135 men and 105 women) with 40 participants per age group were included in the study. In the 1-way ANOVA, the NAMA, LAMA, and IMAT were significantly different between the age groups in both male and female participants (P≤.004), whereas the TAMA showed a significant difference only in male participants (male, P<.001; female, P=.88). The myosteatosis area had a strong negative correlation with muscle densities (r=–0.833 to –0.894), a moderate positive correlation with visceral fat areas (r=0.607 to 0.669), and a weak positive correlation with the subcutaneous fat areas (r=0.305 to 0.441). CONCLUSIONS The automated web-based toolkit is feasible and enables quantitative CT assessment of myosteatosis, which can be a potential quantitative biomarker for evaluating structural and functional changes brought on by aging in the skeletal muscle. CLINICALTRIAL
- Open Access
- 29 June 2020
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 22 (6) , e19569
COVID-19 Pneumonia Diagnosis Using a Simple 2D Deep Learning Framework With a Single Chest CT Image: Model Development and Validation
Background: Coronavirus disease (COVID-19) has spread explosively worldwide since the beginning of 2020. According to a multinational consensus statement from the Fleischner Society, computed tomography (CT) is a relevant screening tool due to its higher sensitivity for detecting early pneumonic changes. However, physicians are extremely occupied fighting COVID-19 in this era of worldwide crisis. Thus, it is crucial to accelerate the development of an artificial intelligence (AI) diagnostic tool to support physicians. Objective: We aimed to rapidly develop an AI technique to diagnose COVID-19 pneumonia in CT images and differentiate it from non–COVID-19 pneumonia and nonpneumonia diseases. Methods: A simple 2D deep learning framework, named the fast-track COVID-19 classification network (FCONet), was developed to diagnose COVID-19 pneumonia based on a single chest CT image. FCONet was developed by transfer learning using one of four state-of-the-art pretrained deep learning models (VGG16, ResNet-50, Inception-v3, or Xception) as a backbone. For training and testing of FCONet, we collected 3993 chest CT images of patients with COVID-19 pneumonia, other pneumonia, and nonpneumonia diseases from Wonkwang University Hospital, Chonnam National University Hospital, and the Italian Society of Medical and Interventional Radiology public database. These CT images were split into a training set and a testing set at a ratio of 8:2. For the testing data set, the diagnostic performance of the four pretrained FCONet models to diagnose COVID-19 pneumonia was compared. In addition, we tested the FCONet models on an external testing data set extracted from embedded low-quality chest CT images of COVID-19 pneumonia in recently published papers. Results: Among the four pretrained models of FCONet, ResNet-50 showed excellent diagnostic performance (sensitivity 99.58%, specificity 100.00%, and accuracy 99.87%) and outperformed the other three pretrained models in the testing data set. In the additional external testing data set using low-quality CT images, the detection accuracy of the ResNet-50 model was the highest (96.97%), followed by Xception, Inception-v3, and VGG16 (90.71%, 89.38%, and 87.12%, respectively). Conclusions: FCONet, a simple 2D deep learning framework based on a single chest CT image, provides excellent diagnostic performance in detecting COVID-19 pneumonia. Based on our testing data set, the FCONet model based on ResNet-50 appears to be the best model, as it outperformed other FCONet models based on VGG16, Xception, and Inception-v3.
- 29 June 2020
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 22 (6) , e19569
Open AccessCOVID-19 Pneumonia Diagnosis Using a Simple 2D Deep Learning Framework With a Single Chest CT Image: Model Development and Validation
Background: Coronavirus disease (COVID-19) has spread explosively worldwide since the beginning of 2020. According to a multinational consensus statement from the Fleischner Society, computed tomography (CT) is a relevant screening tool due to its higher sensitivity for detecting early pneumonic changes. However, physicians are extremely occupied fighting COVID-19 in this era of worldwide crisis. Thus, it is crucial to accelerate the development of an artificial intelligence (AI) diagnostic tool to support physicians. Objective: We aimed to rapidly develop an AI technique to diagnose COVID-19 pneumonia in CT images and differentiate it from non–COVID-19 pneumonia and nonpneumonia diseases. Methods: A simple 2D deep learning framework, named the fast-track COVID-19 classification network (FCONet), was developed to diagnose COVID-19 pneumonia based on a single chest CT image. FCONet was developed by transfer learning using one of four state-of-the-art pretrained deep learning models (VGG16, ResNet-50, Inception-v3, or Xception) as a backbone. For training and testing of FCONet, we collected 3993 chest CT images of patients with COVID-19 pneumonia, other pneumonia, and nonpneumonia diseases from Wonkwang University Hospital, Chonnam National University Hospital, and the Italian Society of Medical and Interventional Radiology public database. These CT images were split into a training set and a testing set at a ratio of 8:2. For the testing data set, the diagnostic performance of the four pretrained FCONet models to diagnose COVID-19 pneumonia was compared. In addition, we tested the FCONet models on an external testing data set extracted from embedded low-quality chest CT images of COVID-19 pneumonia in recently published papers. Results: Among the four pretrained models of FCONet, ResNet-50 showed excellent diagnostic performance (sensitivity 99.58%, specificity 100.00%, and accuracy 99.87%) and outperformed the other three pretrained models in the testing data set. In the additional external testing data set using low-quality CT images, the detection accuracy of the ResNet-50 model was the highest (96.97%), followed by Xception, Inception-v3, and VGG16 (90.71%, 89.38%, and 87.12%, respectively). Conclusions: FCONet, a simple 2D deep learning framework based on a single chest CT image, provides excellent diagnostic performance in detecting COVID-19 pneumonia. Based on our testing data set, the FCONet model based on ResNet-50 appears to be the best model, as it outperformed other FCONet models based on VGG16, Xception, and Inception-v3.
- Open Access
- 23 April 2020
- Published by JMIR Publications Inc. in JMIR Preprints
COVID-19 Pneumonia Diagnosis Using a Simple 2D Deep Learning Framework With a Single Chest CT Image: Model Development and Validation (Preprint)
BACKGROUND Coronavirus disease (COVID-19) has spread explosively worldwide since the beginning of 2020. According to a multinational consensus statement from the Fleischner Society, computed tomography (CT) is a relevant screening tool due to its higher sensitivity for detecting early pneumonic changes. However, physicians are extremely occupied fighting COVID-19 in this era of worldwide crisis. Thus, it is crucial to accelerate the development of an artificial intelligence (AI) diagnostic tool to support physicians. OBJECTIVE We aimed to rapidly develop an AI technique to diagnose COVID-19 pneumonia in CT images and differentiate it from non–COVID-19 pneumonia and nonpneumonia diseases. METHODS A simple 2D deep learning framework, named the fast-track COVID-19 classification network (FCONet), was developed to diagnose COVID-19 pneumonia based on a single chest CT image. FCONet was developed by transfer learning using one of four state-of-the-art pretrained deep learning models (VGG16, ResNet-50, Inception-v3, or Xception) as a backbone. For training and testing of FCONet, we collected 3993 chest CT images of patients with COVID-19 pneumonia, other pneumonia, and nonpneumonia diseases from Wonkwang University Hospital, Chonnam National University Hospital, and the Italian Society of Medical and Interventional Radiology public database. These CT images were split into a training set and a testing set at a ratio of 8:2. For the testing data set, the diagnostic performance of the four pretrained FCONet models to diagnose COVID-19 pneumonia was compared. In addition, we tested the FCONet models on an external testing data set extracted from embedded low-quality chest CT images of COVID-19 pneumonia in recently published papers. RESULTS Among the four pretrained models of FCONet, ResNet-50 showed excellent diagnostic performance (sensitivity 99.58%, specificity 100.00%, and accuracy 99.87%) and outperformed the other three pretrained models in the testing data set. In the additional external testing data set using low-quality CT images, the detection accuracy of the ResNet-50 model was the highest (96.97%), followed by Xception, Inception-v3, and VGG16 (90.71%, 89.38%, and 87.12%, respectively). CONCLUSIONS FCONet, a simple 2D deep learning framework based on a single chest CT image, provides excellent diagnostic performance in detecting COVID-19 pneumonia. Based on our testing data set, the FCONet model based on ResNet-50 appears to be the best model, as it outperformed other FCONet models based on VGG16, Xception, and Inception-v3.
- 23 April 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessCOVID-19 Pneumonia Diagnosis Using a Simple 2D Deep Learning Framework With a Single Chest CT Image: Model Development and Validation (Preprint)
BACKGROUND Coronavirus disease (COVID-19) has spread explosively worldwide since the beginning of 2020. According to a multinational consensus statement from the Fleischner Society, computed tomography (CT) is a relevant screening tool due to its higher sensitivity for detecting early pneumonic changes. However, physicians are extremely occupied fighting COVID-19 in this era of worldwide crisis. Thus, it is crucial to accelerate the development of an artificial intelligence (AI) diagnostic tool to support physicians. OBJECTIVE We aimed to rapidly develop an AI technique to diagnose COVID-19 pneumonia in CT images and differentiate it from non–COVID-19 pneumonia and nonpneumonia diseases. METHODS A simple 2D deep learning framework, named the fast-track COVID-19 classification network (FCONet), was developed to diagnose COVID-19 pneumonia based on a single chest CT image. FCONet was developed by transfer learning using one of four state-of-the-art pretrained deep learning models (VGG16, ResNet-50, Inception-v3, or Xception) as a backbone. For training and testing of FCONet, we collected 3993 chest CT images of patients with COVID-19 pneumonia, other pneumonia, and nonpneumonia diseases from Wonkwang University Hospital, Chonnam National University Hospital, and the Italian Society of Medical and Interventional Radiology public database. These CT images were split into a training set and a testing set at a ratio of 8:2. For the testing data set, the diagnostic performance of the four pretrained FCONet models to diagnose COVID-19 pneumonia was compared. In addition, we tested the FCONet models on an external testing data set extracted from embedded low-quality chest CT images of COVID-19 pneumonia in recently published papers. RESULTS Among the four pretrained models of FCONet, ResNet-50 showed excellent diagnostic performance (sensitivity 99.58%, specificity 100.00%, and accuracy 99.87%) and outperformed the other three pretrained models in the testing data set. In the additional external testing data set using low-quality CT images, the detection accuracy of the ResNet-50 model was the highest (96.97%), followed by Xception, Inception-v3, and VGG16 (90.71%, 89.38%, and 87.12%, respectively). CONCLUSIONS FCONet, a simple 2D deep learning framework based on a single chest CT image, provides excellent diagnostic performance in detecting COVID-19 pneumonia. Based on our testing data set, the FCONet model based on ResNet-50 appears to be the best model, as it outperformed other FCONet models based on VGG16, Xception, and Inception-v3.
- Open Access
- 30 August 2019
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 7 (3) , e14310
A Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study
Background: With the rapid increase in utilization of imaging endpoints in multicenter clinical trials, the amount of data and workflow complexity have also increased. A Clinical Trial Imaging Management System (CTIMS) is required to comprehensively support imaging processes in clinical trials. The US Food and Drug Administration (FDA) issued a guidance protocol in 2018 for appropriate use of medical imaging in accordance with many regulations including the Good Clinical Practice (GCP) guidelines. Existing research on CTIMS, however, has mainly focused on functions and structures of systems rather than regulation and compliance. Objective: We aimed to develop a comprehensive CTIMS to meet the current regulatory guidelines and various required functions. We also aimed to perform computerized system validation focusing on the regulatory compliance of our CTIMS. Methods: Key regulatory requirements of CTIMS were extracted thorough review of many related regulations and guidelines including International Conference on Harmonization-GCP E6, FDA 21 Code of Federal Regulations parts 11 and 820, Good Automated Manufacturing Practice, and Clinical Data Interchange Standards Consortium. The system architecture was designed in accordance with these regulations by a multidisciplinary team including radiologists, engineers, clinical trial specialists, and regulatory medicine professionals. Computerized system validation of the developed CTIMS was performed internally and externally. Results: Our CTIMS (AiCRO) was developed based on a two-layer design composed of the server system and the client system, which is efficient at meeting the regulatory and functional requirements. The server system manages system security, data archive, backup, and audit trail. The client system provides various functions including deidentification, image transfer, image viewer, image quality control, and electronic record. Computerized system validation was performed internally using a V-model and externally by a global quality assurance company to demonstrate that AiCRO meets all regulatory and functional requirements. Conclusions: We developed a Good Practice–compliant CTIMS—AiCRO system—to manage large amounts of image data and complexity of imaging management processes in clinical trials. Our CTIMS adopts and adheres to all regulatory and functional requirements and has been thoroughly validated.
- 30 August 2019
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 7 (3) , e14310
Open AccessA Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study
Background: With the rapid increase in utilization of imaging endpoints in multicenter clinical trials, the amount of data and workflow complexity have also increased. A Clinical Trial Imaging Management System (CTIMS) is required to comprehensively support imaging processes in clinical trials. The US Food and Drug Administration (FDA) issued a guidance protocol in 2018 for appropriate use of medical imaging in accordance with many regulations including the Good Clinical Practice (GCP) guidelines. Existing research on CTIMS, however, has mainly focused on functions and structures of systems rather than regulation and compliance. Objective: We aimed to develop a comprehensive CTIMS to meet the current regulatory guidelines and various required functions. We also aimed to perform computerized system validation focusing on the regulatory compliance of our CTIMS. Methods: Key regulatory requirements of CTIMS were extracted thorough review of many related regulations and guidelines including International Conference on Harmonization-GCP E6, FDA 21 Code of Federal Regulations parts 11 and 820, Good Automated Manufacturing Practice, and Clinical Data Interchange Standards Consortium. The system architecture was designed in accordance with these regulations by a multidisciplinary team including radiologists, engineers, clinical trial specialists, and regulatory medicine professionals. Computerized system validation of the developed CTIMS was performed internally and externally. Results: Our CTIMS (AiCRO) was developed based on a two-layer design composed of the server system and the client system, which is efficient at meeting the regulatory and functional requirements. The server system manages system security, data archive, backup, and audit trail. The client system provides various functions including deidentification, image transfer, image viewer, image quality control, and electronic record. Computerized system validation was performed internally using a V-model and externally by a global quality assurance company to demonstrate that AiCRO meets all regulatory and functional requirements. Conclusions: We developed a Good Practice–compliant CTIMS—AiCRO system—to manage large amounts of image data and complexity of imaging management processes in clinical trials. Our CTIMS adopts and adheres to all regulatory and functional requirements and has been thoroughly validated.
- Open Access
- 8 April 2019
- Published by JMIR Publications Inc. in JMIR Preprints
A Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study (Preprint)
BACKGROUND With the rapid increase in utilization of imaging endpoints in multicenter clinical trials, the amount of data and workflow complexity have also increased. A Clinical Trial Imaging Management System (CTIMS) is required to comprehensively support imaging processes in clinical trials. The US Food and Drug Administration (FDA) issued a guidance protocol in 2018 for appropriate use of medical imaging in accordance with many regulations including the Good Clinical Practice (GCP) guidelines. Existing research on CTIMS, however, has mainly focused on functions and structures of systems rather than regulation and compliance. OBJECTIVE We aimed to develop a comprehensive CTIMS to meet the current regulatory guidelines and various required functions. We also aimed to perform computerized system validation focusing on the regulatory compliance of our CTIMS. METHODS Key regulatory requirements of CTIMS were extracted thorough review of many related regulations and guidelines including International Conference on Harmonization-GCP E6, FDA 21 Code of Federal Regulations parts 11 and 820, Good Automated Manufacturing Practice, and Clinical Data Interchange Standards Consortium. The system architecture was designed in accordance with these regulations by a multidisciplinary team including radiologists, engineers, clinical trial specialists, and regulatory medicine professionals. Computerized system validation of the developed CTIMS was performed internally and externally. RESULTS Our CTIMS (AiCRO) was developed based on a two-layer design composed of the server system and the client system, which is efficient at meeting the regulatory and functional requirements. The server system manages system security, data archive, backup, and audit trail. The client system provides various functions including deidentification, image transfer, image viewer, image quality control, and electronic record. Computerized system validation was performed internally using a V-model and externally by a global quality assurance company to demonstrate that AiCRO meets all regulatory and functional requirements. CONCLUSIONS We developed a Good Practice–compliant CTIMS—AiCRO system—to manage large amounts of image data and complexity of imaging management processes in clinical trials. Our CTIMS adopts and adheres to all regulatory and functional requirements and has been thoroughly validated.
- 8 April 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Good Practice–Compliant Clinical Trial Imaging Management System for Multicenter Clinical Trials: Development and Validation Study (Preprint)
BACKGROUND With the rapid increase in utilization of imaging endpoints in multicenter clinical trials, the amount of data and workflow complexity have also increased. A Clinical Trial Imaging Management System (CTIMS) is required to comprehensively support imaging processes in clinical trials. The US Food and Drug Administration (FDA) issued a guidance protocol in 2018 for appropriate use of medical imaging in accordance with many regulations including the Good Clinical Practice (GCP) guidelines. Existing research on CTIMS, however, has mainly focused on functions and structures of systems rather than regulation and compliance. OBJECTIVE We aimed to develop a comprehensive CTIMS to meet the current regulatory guidelines and various required functions. We also aimed to perform computerized system validation focusing on the regulatory compliance of our CTIMS. METHODS Key regulatory requirements of CTIMS were extracted thorough review of many related regulations and guidelines including International Conference on Harmonization-GCP E6, FDA 21 Code of Federal Regulations parts 11 and 820, Good Automated Manufacturing Practice, and Clinical Data Interchange Standards Consortium. The system architecture was designed in accordance with these regulations by a multidisciplinary team including radiologists, engineers, clinical trial specialists, and regulatory medicine professionals. Computerized system validation of the developed CTIMS was performed internally and externally. RESULTS Our CTIMS (AiCRO) was developed based on a two-layer design composed of the server system and the client system, which is efficient at meeting the regulatory and functional requirements. The server system manages system security, data archive, backup, and audit trail. The client system provides various functions including deidentification, image transfer, image viewer, image quality control, and electronic record. Computerized system validation was performed internally using a V-model and externally by a global quality assurance company to demonstrate that AiCRO meets all regulatory and functional requirements. CONCLUSIONS We developed a Good Practice–compliant CTIMS—AiCRO system—to manage large amounts of image data and complexity of imaging management processes in clinical trials. Our CTIMS adopts and adheres to all regulatory and functional requirements and has been thoroughly validated.
- Top Cited PapersOpen Access
- 1 January 2019
- Published by XMLink in Korean Journal of Radiology
- Vol. 20 (3) , 405-410
Design Characteristics of Studies Reporting the Performance of Artificial Intelligence Algorithms for Diagnostic Analysis of Medical Images: Results from Recently Published Papers
Kim DW, et al. Korean J Radiol. 2019 Mar;20(3):405-410. https://doi.org/10.3348/kjr.2019.0025
- 1 January 2019
- Published by XMLink in Korean Journal of Radiology
- Vol. 20 (3) , 405-410
Top Cited PapersOpen AccessDesign Characteristics of Studies Reporting the Performance of Artificial Intelligence Algorithms for Diagnostic Analysis of Medical Images: Results from Recently Published Papers
Kim DW, et al. Korean J Radiol. 2019 Mar;20(3):405-410. https://doi.org/10.3348/kjr.2019.0025