CRClayton J. Radke

Clayton J. Radke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Clayton J. Radke has a total of 163 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electrostatically Limited PFSA Ionomer Adsorption to Catalyst Particles in Catalyst Inks

    by Siddharth Rajupet, Niki Jacquin, Sarah A. Berlinger, Maximilian Degirmenci, Finn Babbe, Nathan Stovall, Douglas I. Kushner, Clayton J. Radke, Adam Z. Weber

    Understanding and controlling ionomer adsorption in catalyst inks is critical to optimizing catalyst-layer structure and performance in membrane-electrode assemblies. Here, we systematically quantify perfluorosulfonic-acid (PFSA) ionomer adsorption across a diverse set of catalyst particles, including carbon and Pt/C, functionalized carbons, and iridium oxide (IrOx). We find that the extent of adsorption varies by nearly an order of magnitude among these diverse particles. Using potentiometric titration, the measured particle surface-charge densities are related to adsorption behavior using a kinetic adsorption model. A free-energy barrier arises in the kinetic theory because of repulsive electric double-layer interactions between the anionic ionomer in solution and the solid substrate. We calculate these interactions from DLVO theory adapted to PFSA systems. The energy barrier grows as the ionomer adsorbs to support-particle surfaces and imparts a negative surface charge through the adsorbed sulfonic-acid moieties. Ionomer adsorption self-quenches when the energy barrier is larger than about 25 kBT. We find excellent agreement between theory and experiment, and show that, for a given ionomer concentration, particles adsorb ionomer until reaching a common limiting surface-charge density, independent of particle type. By leveraging this insight, we demonstrate that adsorption can be systematically tuned via surface functionalization that modulates support-particle charge. The findings establish electrostatic interactions as the dominant mechanism limiting the extent of PFSA ionomer adsorption, providing a general framework for the rational design of catalyst inks and improved ionomer distributions in catalyst layers.

  • Open Access

    Predicting Particle-Size Distributions in Fuel-Cell Inks

    by Harsh Srivastav, Adam Zev Weber, Clayton J. Radke

    Prediction of the catalyst-activated carbon particle sizes of fuel-cell inks remains a critical challenge in enhancing the performance and durability of fuel cells. The performance and structural integrity of the catalyst layers in the cell depends not only on the properties of the ionomer, but also the carbon supports that host the catalyst. To investigate how these carbon aggregate structures form, we present a model that calculates the cooperative size distributions of ionomer and carbon aggregates in various water/alcohol mixtures and compares those results to available experimental data. Aggregation of both the suspended ionomers and the carbon particles is interwoven as the carbon aggregation depends heavily on the ionic strength of its environment, namely protons dissociating from the ionomer’s sulfonic-acid-group side chains. We demonstrate that the surrounding mixed solvent as well as Nafion binder concentration strongly influence the degree of aggregation for carbon particles. The validated model provides a framework for exploring aggregation under a wide range of conditions for various electrochemical-technology inks.

  • Open Access

    High speed 3D laser imaging setup for fluid dynamics research applications

    by Ahmed M Saad, Ivan S Chukanov, Maxim P Yutkin, Yuansi Tian, Sigurdur T Thoroddsen, Clayton J Radke, Tadeusz W Patzek

    In this paper, a high-speed 3D laser imaging system is developed to study multiphase fluid flow in transparent systems. The setup consists of a dynamic laser sheet and a high-speed camera to capture rapid pore-scale events within microsecond time resolution. To exclude optical artifacts, we use immiscible fluids with closely matched refractive indices (within ±0.3%) and fluorescent dyes to highlight fluid interfaces and phases. The setup scans the object volume by moving a narrow laser sheet across the sample width, producing 2D slices that are subsequently reconstructed into time-resolved 3D images. An overscanning technique improves spatial resolution by overlapping scans, allowing detailed interface reconstruction without sacrificing field of view. The imaging system was validated through static and dynamic displacement experiments in square glass capillaries, showing accurate tracking of fluid interfaces and precise volumetric measurements. The setup can be applied for fluid flow visualization in research applications such as enhanced oil recovery, CO 2 sequestration, and porous media flow.

  • Hydrogen Electrocatalysis on Perfluorosulfonic-Acid-Coated Pt

    by Grace C. Anderson, Siddharth Rajupet, Douglas I. Kushner, Adam Z. Weber, Clayton J. Radke, Alexis T. Bell


  • Open Access

    Generalized Extreme Value Statistics for Scaling Oil Recovery from Water-Wet and Mixed-Wet Carbonate Rock

    by Ksenia M. Kaprielova, Maxim P. Yutkin, Ahmed Gmira, Subhash Ayirala, Ali Yousef, Clayton J. Radke, Tadeusz W. Patzek

    Counter-current, spontaneous imbibition of brine into oil-saturated rocks is a critical process for recovery of bypassed oil in carbonate reservoirs. However, the classic Amott-cell test introduces experimental artifacts that distort the true dynamics of oil recovery, complicating the interpretation and modeling of recovery histories. In this study, we applied a modified Amott procedure to eliminate these artifacts, producing smooth and reproducible recovery histories for both water-wet and mixed-wet carbonate core plugs saturated with brine and oil. By applying Generalized Extreme Value (GEV) statistics, we modeled cumulative oil production and showed that a GEV model is able to capture the essentially non-equilibrium nature of spontaneous imbibition. Our results demonstrate that water-wet systems exhibit faster recovery rates and shorter induction times due to favorable capillary forces, while mixed-wet samples have slower dynamics and longer induction times, reflecting the influence of wettability alterations. We demonstrate that the GEV fitting parameters systematically correlate with key rock–fluid properties, such as wettability, oil viscosity, and pore network characteristics, offering a semi-quantitative approach to analyze recovery behavior. This study demonstrates the potential of a GEV-based statistical model to deepen understanding of the spontaneous imbibition mechanisms and to enhance predictive capabilities for oil production dynamics.

  • Open Access

    Physical Interpretation of Interwell Partitioning Tracer Tests for Estimation of Remaining Oil Saturation in Layered Carbonate Reservoirs

    by Samuel D. Fontalvo, Maxim P. Yutkin, S. Majid Hassanizadeh, Clayton J. Radke, Tadeusz W. Patzek

    Interwell partitioning tracer tests (IPTTs) are conducted in mature oil fields to estimate remaining oil in place, which is crucial for subsequent economic analyses and decisions regarding further field development. An IPTT involves the simultaneous injection of two types of tracers: conservative and partitioning, that probe the aqueous and oil phases, respectively. Although this test requires time, it probes the entire fluid flow path, not just the near-wellbore area, as is the case with other methods such as single-well tests. Accurate interpretation of interwell tracer test data is of critical importance for the oil and gas industry. Published IPTT case studies lack physical justification for the choice of tracer flow models. In this study, we provide such justifications along with guidelines for selecting appropriate tracer flow models. First, we review existing models for the transport of partitioning and conservative tracers and demonstrate their applicability range based on mass conservation analysis. Based on this analysis, we propose a refined model of partitioning tracer flow with Robin boundary conditions that accounts for non-equilibrium partitioning. Such analysis is missing in the literature. Next, we illustrate errors in estimating remaining oil if an inappropriate model is used for data interpretation. Notably, the choice of an incorrect model can lead to either underestimation or overestimation of the remaining oil, with the latter being of greater financial concern. Finally, we apply the non-equilibrium partitioning model to a published IPTT dataset from a layered carbonate reservoir and compare our remaining oil estimates with results of the original study. To the best of our knowledge, analysis of such cases with non-equilibrium partitioning has not been documented in the literature.


  • Pre‐wetted modified Schirmer’s tear test to determine lacrimal tear‐production rate from severe lacrimal‐gland dysfunction patients

    by Young Hyun Kim, Sarah M. Ba Chang, Jennifer E. Od Ding, Meng C. OD Lin, Clayton J. Radke

    SIGNIFICANCE: To determine basal tear‐production rates from low tear‐producing patients, we present a prewetted modified Schirmer’s tear test (PW‐MSTT). The improved method is an extension of the MSTT that provides a reliable method to investigate the relation between dry‐eye symptoms and basal tear production rates. PURPOSE: The MSTT quantifies basal tear‐production rates from patients. However, the existing test does not allow measurement of basal tear‐production rates from patients that do not wet past the 5‐mm mark on the Schirmer strip within 5 minutes. We extended the MSTT with a prewetting technique to allow quantification of basal tear‐production rates from patients that do not adequately wet the Schirmer strip within 5 minutes of strip insertion. METHODS: An in‐vitro study was conducted with sheathed Schirmer strips to determine the volume of sterile nonpreservative saline solution necessary to prewet the Schirmer strip before insertion. This assessment determined that 1.6 µL of prewetting saline wets the Schirmer strip to 5.2 mm of the Schirmer strip, enough to allow basal tear production rate determination from subjects that do not adequately wet the Schirmer strip out to the 5‐mm mark. Then, a clinical study was conducted with sheathed Schirmer strips with the prewetting technique to determine the basal tear‐production rate from subjects that could not wet sufficiently to determine their basal tear‐production rate. RESULTS: Eleven subjects completed the study; the basal tear production rates from these low tear‐producing subjects were determined. The mean (SD) of the measured basal tear‐production rate was 0.40 µL/min (0.28 µL/min) compared with normal subjects at 1.19 µL/min. CONCLUSIONS: The developed PW‐MSTT successfully quantifies basal tear production rates from subjects that do not adequately wet the Schirmer strip without the new prewetting technique. The determined basal tear‐production rate from these low tear‐producing subjects was three times less than that of those from a previous study where the subjects could adequately wet the Schirmer strip past the 5‐mm line. Our improved methodology for low tear‐producing patients sheds insight into how basal tear production rate is related to aqueous‐deficient dry‐eye symptoms.

  • PFSA-Ionomer Adsorption to C and Pt/C Particles in Fuel-Cell Inks

    by Siddharth Rajupet, Adam Z. Weber, Clayton J. Radke

    Catalyst inks used to make fuel-cell electrodes consist of Pt/C catalyst particles and a perfluorosulfonic acid (PFSA) ionomer dispersed in water/alcohol solvent mixtures. PFSA ionomer in the ink adsorbs to the surface of the catalyst particles, dictating the dispersion colloid properties. Following adsorption, the subsequent distribution of excess nonadsorbed ionomer in the ink then governs the final structure of the electrode. Here, we characterize the adsorption of the PFSA ionomer onto Pt/C catalyst particles. PFSA adsorption is largely irreversible. Adsorbed sulfonic-acid moieties impart a negative charge on the catalyst surface, causing electrostatic repulsion between the free ionomer in solution and the ionomer-covered Pt/C particle surface. The amount of adsorption is limited by the resulting electrostatic charge that grows as more ionomer adsorbs, and the catalyst surface becomes more negatively charged. Attenuating electrostatic repulsion by increasing the ink ionic strength promotes ionomer adsorption. Electrostatically limited adsorption is observed, irrespective of the solvent water/n-propanol ratio or the catalyst particle porosity and Pt loading. Experimentally measured ionomer adsorption isotherms are well predicted by a Smoluchowski-based kinetic adsorption model, in which the electrostatic energy barrier for adsorption is predicted from DLVO theory. These findings help to unravel the complex phenomena within these colloidal dispersions, allowing for subsequent tailoring of inks to optimize fuel-cell electrode structure and performance.


  • Open Access

    Localized Evaporative Cooling Explains Observed Ocular Surface-Temperature Patterns

    by Young Hyun Kim, Joshua Lee, Sarah M. Yi, Meng C. Lin, Clayton J. Radke

    Purpose: We determined interblink corneal surface-temperature decline and tear-film evaporation rates of localized tear breakup cold regions (LCRs) and localized tear unbroken warm regions (LWRs) of the corneal surface, as well as that of the overall average corneal surface. Methods: Each subject underwent 4 inter-day visits where the interblink corneal surface-temperature history of the right eye was measured using a FLIR A655sc infrared thermographer. Corneal surface temperature history was analyzed to determine the overall, LCR, and LWR temperature-decline rates. Evaporation rates of LCR and LWR regions were determined from the measured LCR and LWR temperature data using the physical model of Dursch et al. Results: Twenty subjects completed the study. Mean (SD) difference of LCR temperature-decline rate was −0.08 (0.07)°C/s faster than LWR (P < 0.0001). Similarly, evaporation rates of LCR and LWR were statistically different (P < 0.0001). At ambient temperature, mean LCR and LWR evaporation rates were 76% and 27% of pure water evaporation flux, respectively. There was no statistically significant difference between the inter-day measured temperature-decline rates and the interblink starting temperature. Conclusions: Significant differences in corneal temperature-decline rate and evaporation rate between LCR and LWR were quantified using infrared thermography. In agreement with literature, LCRs and LWRs correlate directly with fluorescein break-up areas and unbroken tear areas, respectively. Because lipid-evaporation protection is diminished in breakup areas, higher local evaporation rates and faster local cooling rates occur in LCRs relative to LWRs. Our results confirm this phenomenon clinically for the first time.