Ya-Ting Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ya-Ting Li has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Chun-Zhao Shi
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
1 shared publication - Fumin Zhang
Tianjin University
1 shared publication - Hao Pan
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
1 shared publication - Xinghua Qu
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
1 shared publication
Latest Publications
- Open Access
- 3 January 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (1) , 147
Vibration Compensation of the Frequency-Scanning-Interferometry-Based Absolute Ranging System
The frequency-scanning-interferometry-based (FSI-based) absolute ranging technology is a type of ranging technology possessing a high precision and no ranging blind area, so it can be used for non-cooperative targets. However, due to a tiny movement of a target, the Doppler shift and the phase modulation are introduced into the beat signal which results in ranging accuracy decrease. In order to solve this problem, first the model of vibration effect is established, and then the beat signals of two adjacent scanning periods are processed to produce a signal that is immune to vibration. The proposed method is verified by the experiments, and the experimental results show that the effect of vibration compensation is better for the target with a lower vibration velocity and at a lower vibration frequency (lower than 6 Hz). When the target is subjected to a sinusoidal vibration with an amplitude of 10 μm at a frequency of 1 Hz, by using the proposed method the standard deviation is reduced from 775 to 12 μm. Moreover, in the natural environment, by using vibration compensation the standard deviation is reduced from 289 to 11 μm.
- 3 January 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (1) , 147
Open AccessVibration Compensation of the Frequency-Scanning-Interferometry-Based Absolute Ranging System
The frequency-scanning-interferometry-based (FSI-based) absolute ranging technology is a type of ranging technology possessing a high precision and no ranging blind area, so it can be used for non-cooperative targets. However, due to a tiny movement of a target, the Doppler shift and the phase modulation are introduced into the beat signal which results in ranging accuracy decrease. In order to solve this problem, first the model of vibration effect is established, and then the beat signals of two adjacent scanning periods are processed to produce a signal that is immune to vibration. The proposed method is verified by the experiments, and the experimental results show that the effect of vibration compensation is better for the target with a lower vibration velocity and at a lower vibration frequency (lower than 6 Hz). When the target is subjected to a sinusoidal vibration with an amplitude of 10 μm at a frequency of 1 Hz, by using the proposed method the standard deviation is reduced from 775 to 12 μm. Moreover, in the natural environment, by using vibration compensation the standard deviation is reduced from 289 to 11 μm.