Ozgur Ozcelik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ozgur Ozcelik has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Ibrahim Serkan Misir
Civil Engineering Department, Dokuz Eylül University, Izmir 35390, Türkiye
3 shared publications - Ahmet Başbuğ
Department of Computer Engineering, Dokuz Eylül University, Izmir 35390, Türkiye
2 shared publications - Alp Kut
Department of Computer Engineering, Dokuz Eylül University, Izmir 35390, Türkiye
2 shared publications - Erkan Durmazgezer
Department of Civil Engineering, Yasar University, Izmir 35100, Türkiye
2 shared publications - Fatih Semirgin
Department of Computer Engineering, Dokuz Eylül University, Izmir 35390, Türkiye
2 shared publications - Hasan Sözbilir
Dokuz Eylül Üniversitesi
2 shared publications
Latest Publications
- Open Access
Earthquake Early Warning System for Izmir, Western Anatolia, Türkiye Based on Multi-Station Similarity Analysis and Real-Time Seismic Data Processing
Earthquake Early Warning Systems (EEWS) represent one of the most effective technological solutions for mitigating the impacts of strong ground motion in seismically active regions. This study presents the design, implementation, and comprehensive evaluation of a real-time earthquake early warning system for Izmir-a region in Western Anatolia characterized by complex tectonic structures and high seismic hazard-using multi-station seismic acceleration data. The proposed framework integrates multi-threaded data acquisition, signal preprocessing, Min-Max normalization, and Euclidean distance-based similarity analysis to enable rapid detection of anomalous seismic patterns during the early P-wave phase. The system architecture consists of distributed sensor inputs, centralized real-time processing, similarity-based anomaly detection, and user-oriented visualization and alerting modules. The performance of the system was evaluated using both real and synthetic seismic datasets. Instrumental earthquake catalog from the 12 June 2017 Karaburun (Mw 6.2) and 30 October 2020 Samos (Mw 6.6) earthquakes demonstrate that the system can generate early warnings 18 s and 13 s prior to strong ground shaking, respectively. In addition, synthetic seismic scenarios were employed to assess system robustness under varying noise levels, station configurations, and signal conditions. The results indicate that the proposed framework maintains stable detection performance and low false-positive rates across diverse operational scenarios. The methodology emphasizes computational efficiency and inter-station waveform coherence analysis, providing a lightweight alternative to conventional magnitude-based approaches. By avoiding computationally intensive source inversion, the system achieves low-latency performance while preserving detection reliability. The proposed EEWS demonstrates strong generalization capability, scalability, and practical applicability for real-time deployment in earthquake-prone urban environments.
Open AccessEarthquake Early Warning System for Izmir, Western Anatolia, Türkiye Based on Multi-Station Similarity Analysis and Real-Time Seismic Data Processing
Earthquake Early Warning Systems (EEWS) represent one of the most effective technological solutions for mitigating the impacts of strong ground motion in seismically active regions. This study presents the design, implementation, and comprehensive evaluation of a real-time earthquake early warning system for Izmir-a region in Western Anatolia characterized by complex tectonic structures and high seismic hazard-using multi-station seismic acceleration data. The proposed framework integrates multi-threaded data acquisition, signal preprocessing, Min-Max normalization, and Euclidean distance-based similarity analysis to enable rapid detection of anomalous seismic patterns during the early P-wave phase. The system architecture consists of distributed sensor inputs, centralized real-time processing, similarity-based anomaly detection, and user-oriented visualization and alerting modules. The performance of the system was evaluated using both real and synthetic seismic datasets. Instrumental earthquake catalog from the 12 June 2017 Karaburun (Mw 6.2) and 30 October 2020 Samos (Mw 6.6) earthquakes demonstrate that the system can generate early warnings 18 s and 13 s prior to strong ground shaking, respectively. In addition, synthetic seismic scenarios were employed to assess system robustness under varying noise levels, station configurations, and signal conditions. The results indicate that the proposed framework maintains stable detection performance and low false-positive rates across diverse operational scenarios. The methodology emphasizes computational efficiency and inter-station waveform coherence analysis, providing a lightweight alternative to conventional magnitude-based approaches. By avoiding computationally intensive source inversion, the system achieves low-latency performance while preserving detection reliability. The proposed EEWS demonstrates strong generalization capability, scalability, and practical applicability for real-time deployment in earthquake-prone urban environments.
- Open Access
Large-Scale Testing of a Novel Self-Centering Brace with U-Shaped Plates for Seismic Energy Dissipation
Energy-dissipating braces are novel structural components as they not only accommodate the seismic energy demand but also enhance both the flexibility and overall earthquake resistance of the structure, preventing brittle or non-ductile behavior. The novel brace proposed in this study was developed to achieve two primary objectives: first, to restrict relative displacements at its ends by dissipating energy through U-shaped flexural plates (UFPs), and second, to provide a self-centering mechanism through the use of post-tension (PT) to ensure structural re-centering after cyclic loading. The novelty of this research lies in the experimental findings showing that post-tensioned (PT) braces exhibit a flag-shaped self-centering hysteretic response, improved initial stiffness, and reduced residual displacements by 72%, while non-PT braces behave as conventional metallic dissipators with larger residual displacements. Increasing UFP thickness from 6 to 8 mm enhances strength by 22%. Stainless steel UFPs offer superior plastic recovery, whereas regular steel UFPs dissipate ~%10 more energy through greater plasticity. Energy dissipation of the brace increases with increasing PT forces and displacement due to the PT force pulling the force–displacement curve towards high force levels. This study highlights the importance of PT force and UFP parameters in a brace configuration with self-centering and metallic dissipators such as U-shaped flexural plates.
Open AccessLarge-Scale Testing of a Novel Self-Centering Brace with U-Shaped Plates for Seismic Energy Dissipation
Energy-dissipating braces are novel structural components as they not only accommodate the seismic energy demand but also enhance both the flexibility and overall earthquake resistance of the structure, preventing brittle or non-ductile behavior. The novel brace proposed in this study was developed to achieve two primary objectives: first, to restrict relative displacements at its ends by dissipating energy through U-shaped flexural plates (UFPs), and second, to provide a self-centering mechanism through the use of post-tension (PT) to ensure structural re-centering after cyclic loading. The novelty of this research lies in the experimental findings showing that post-tensioned (PT) braces exhibit a flag-shaped self-centering hysteretic response, improved initial stiffness, and reduced residual displacements by 72%, while non-PT braces behave as conventional metallic dissipators with larger residual displacements. Increasing UFP thickness from 6 to 8 mm enhances strength by 22%. Stainless steel UFPs offer superior plastic recovery, whereas regular steel UFPs dissipate ~%10 more energy through greater plasticity. Energy dissipation of the brace increases with increasing PT forces and displacement due to the PT force pulling the force–displacement curve towards high force levels. This study highlights the importance of PT force and UFP parameters in a brace configuration with self-centering and metallic dissipators such as U-shaped flexural plates.
- Open Access
- 10 June 2024
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 12 (S1) , 803-824
Effects of Operational and Environmental Conditions on Estimated Dynamic Characteristics of a Large In-service Wind Turbine
Purpose: The reliable and continuous operation of wind turbines is of utmost importance, making it necessary to thoroughly understand their dynamic behavior under various operational and environmental conditions. Methods: To achieve this, a data acquisition system distributed throughout the tower height is designed. The system records data such as the acceleration, temperature, and relative humidity from the sensors, along with the rotor speed, wind speed, temperature, pitch angle, nacelle direction, and wind direction from the data acquisition system of the turbine. The acquired data is synchronized and processed by Autonomous and Continuous System Identification system based on the poly-reference Least Squares Complex Frequency method. The extensive dataset, gathered over a 7-month period, allows for the estimation of modal parameters of the wind turbine. The modal parameters are then correlated with the operational and environmental conditions that were recorded. The relationships between these conditions are thoroughly analyzed and explained. Additionally, the operational principles of the wind turbine are elucidated in detail. The correlations between the modal parameters and operational or environmental factors are presented and interpreted, shedding light on the complex interplay between wind turbine dynamics and external conditions. Conclusion: It can be said that changes in operational and environmental conditions affect the modal parameters of the wind turbine differently across various structural modes. Without considering these effects, structural health monitoring systems may produce false alarms. Failure to consider these effects in the development of structural health monitoring systems may lead to incorrect damage alarms.
- 10 June 2024
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 12 (S1) , 803-824
Open AccessEffects of Operational and Environmental Conditions on Estimated Dynamic Characteristics of a Large In-service Wind Turbine
Purpose: The reliable and continuous operation of wind turbines is of utmost importance, making it necessary to thoroughly understand their dynamic behavior under various operational and environmental conditions. Methods: To achieve this, a data acquisition system distributed throughout the tower height is designed. The system records data such as the acceleration, temperature, and relative humidity from the sensors, along with the rotor speed, wind speed, temperature, pitch angle, nacelle direction, and wind direction from the data acquisition system of the turbine. The acquired data is synchronized and processed by Autonomous and Continuous System Identification system based on the poly-reference Least Squares Complex Frequency method. The extensive dataset, gathered over a 7-month period, allows for the estimation of modal parameters of the wind turbine. The modal parameters are then correlated with the operational and environmental conditions that were recorded. The relationships between these conditions are thoroughly analyzed and explained. Additionally, the operational principles of the wind turbine are elucidated in detail. The correlations between the modal parameters and operational or environmental factors are presented and interpreted, shedding light on the complex interplay between wind turbine dynamics and external conditions. Conclusion: It can be said that changes in operational and environmental conditions affect the modal parameters of the wind turbine differently across various structural modes. Without considering these effects, structural health monitoring systems may produce false alarms. Failure to consider these effects in the development of structural health monitoring systems may lead to incorrect damage alarms.
- Open Access
- 27 September 2023
- Published by Deu Muhendislik Fakultesi Fen ve Muhendislik in Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi
- Vol. 25 (75) , 611-622
Kullanımda Olan 2,5 MW Kapasiteli Bir Rüzgâr Türbininden Veri Toplanması, Sistem Tanımlama ve Model Güncelleme
Rüzgâr enerjisi, dünya genelinde hızla artan enerji ihtiyacı ve bu ihtiyacın çevreci çözümlerle giderilmesi gerekliliğiyle önemini her geçen gün arttırmaktadır. Kısa zamanda daha çok enerji üretebilen görece büyük rüzgâr türbinleri, rüzgâr enerji potansiyelinin fazla olması nedeniyle deprem bölgelerinde de inşa edilmektedir. Rüzgâr türbinlerinin ekonomik ömrü boyunca operasyonel kalabilmesi için yapısal bütünlüğünün izlenmesi ve dinamik özelliklerinin değişken operasyonel ve çevresel faktörler altında belirlenmesi büyük önem taşımaktadır. Bu çalışmada, kullanımda olan 2,5 MW üretim kapasiteli bir rüzgâr türbini için özgün veri toplama sistemi tasarlanmıştır. Sistemin kendi sensörlerinin topladığı ivme, sıcaklık ve nem verilerine ek olarak türbin SCADA sisteminden alınan rüzgâr hızı, rüzgâr yönü, rotor hızı, nasel yönü, pitch açısı ve anlık enerji üretim değeri verileri senkronize olarak kaydedilmiştir. Farklı çevresel ve operasyonel koşullar altında toplanan ivme verileri ile operasyonel modal analizler yapılmış ve türbinin dinamik özellikleri belirlenmiştir. Son olarak mod frekanslarının çevresel ve operasyonel faktörler ile ilişkisi de göz önünde bulundurularak, türbinin sayısal modeli güncellenmiştir.
- 27 September 2023
- Published by Deu Muhendislik Fakultesi Fen ve Muhendislik in Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi
- Vol. 25 (75) , 611-622
Open AccessKullanımda Olan 2,5 MW Kapasiteli Bir Rüzgâr Türbininden Veri Toplanması, Sistem Tanımlama ve Model Güncelleme
Rüzgâr enerjisi, dünya genelinde hızla artan enerji ihtiyacı ve bu ihtiyacın çevreci çözümlerle giderilmesi gerekliliğiyle önemini her geçen gün arttırmaktadır. Kısa zamanda daha çok enerji üretebilen görece büyük rüzgâr türbinleri, rüzgâr enerji potansiyelinin fazla olması nedeniyle deprem bölgelerinde de inşa edilmektedir. Rüzgâr türbinlerinin ekonomik ömrü boyunca operasyonel kalabilmesi için yapısal bütünlüğünün izlenmesi ve dinamik özelliklerinin değişken operasyonel ve çevresel faktörler altında belirlenmesi büyük önem taşımaktadır. Bu çalışmada, kullanımda olan 2,5 MW üretim kapasiteli bir rüzgâr türbini için özgün veri toplama sistemi tasarlanmıştır. Sistemin kendi sensörlerinin topladığı ivme, sıcaklık ve nem verilerine ek olarak türbin SCADA sisteminden alınan rüzgâr hızı, rüzgâr yönü, rotor hızı, nasel yönü, pitch açısı ve anlık enerji üretim değeri verileri senkronize olarak kaydedilmiştir. Farklı çevresel ve operasyonel koşullar altında toplanan ivme verileri ile operasyonel modal analizler yapılmış ve türbinin dinamik özellikleri belirlenmiştir. Son olarak mod frekanslarının çevresel ve operasyonel faktörler ile ilişkisi de göz önünde bulundurularak, türbinin sayısal modeli güncellenmiştir.
- 12 October 2022
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 48 (4) , 5199-5214
Damage Identification of a Model Frame-Type Structure and Effects of Offline Tuning Technique on the Identification Results
- 12 October 2022
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 48 (4) , 5199-5214
Damage Identification of a Model Frame-Type Structure and Effects of Offline Tuning Technique on the Identification Results
- 27 July 2022
- Published by Springer Nature in Journal of Civil Structural Health Monitoring
- Vol. 12 (5) , 1157-1172
Model updating of Masonry courtyard walls of the historical Isabey mosque using ambient vibration measurements
- 27 July 2022
- Published by Springer Nature in Journal of Civil Structural Health Monitoring
- Vol. 12 (5) , 1157-1172
Model updating of Masonry courtyard walls of the historical Isabey mosque using ambient vibration measurements
- 30 July 2021
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 50 (12) , 3288-3310
Comprehensive mechanics‐based virtual model of NHERI@UCSD shake table—Uniaxial configuration and bare table condition
A mechanics‐based virtual model of the NHERI@UCSD large high‐performance outdoor shake table (LHPOST) in its uniaxial configuration and under bare table condition is presented. The virtual model includes: (i) a reprogrammed version (i.e., virtual replica) of the actual controller, (ii) a servovalve model including servovalve spool dynamics and two independent servovalve flow nonlinearities for each of the four servovalves of the system, (iii) an actuator model for each of the two single‐ended actuators, (iv) two accumulators modeling the average supply pressure drop at the entrance of the servovalves, and (v) a one‐degree‐of‐freedom mechanical subsystem model. Based on forced vibration test results for the foundation block, it was found that the soil‐foundation compliance effects do not need to be included in the virtual model of the LHPOST. The virtual model presented is able to predict accurately the actual shake table platen response under narrow and broadband inputs with the controller gains set to the same values as on the actual shake table. Moreover, the fourth stage spool displacements and actuator driving force from actual tests are reproduced accurately by the virtual model. The mechanics‐based virtual model presented in this article can be coupled with FE models of specimens to be tested on the LHPOST and can be used to improve the signal reproduction fidelity of the LHPOST and to develop more advanced model‐based shake table controllers.
- 30 July 2021
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 50 (12) , 3288-3310
Comprehensive mechanics‐based virtual model of NHERI@UCSD shake table—Uniaxial configuration and bare table condition
A mechanics‐based virtual model of the NHERI@UCSD large high‐performance outdoor shake table (LHPOST) in its uniaxial configuration and under bare table condition is presented. The virtual model includes: (i) a reprogrammed version (i.e., virtual replica) of the actual controller, (ii) a servovalve model including servovalve spool dynamics and two independent servovalve flow nonlinearities for each of the four servovalves of the system, (iii) an actuator model for each of the two single‐ended actuators, (iv) two accumulators modeling the average supply pressure drop at the entrance of the servovalves, and (v) a one‐degree‐of‐freedom mechanical subsystem model. Based on forced vibration test results for the foundation block, it was found that the soil‐foundation compliance effects do not need to be included in the virtual model of the LHPOST. The virtual model presented is able to predict accurately the actual shake table platen response under narrow and broadband inputs with the controller gains set to the same values as on the actual shake table. Moreover, the fourth stage spool displacements and actuator driving force from actual tests are reproduced accurately by the virtual model. The mechanics‐based virtual model presented in this article can be coupled with FE models of specimens to be tested on the LHPOST and can be used to improve the signal reproduction fidelity of the LHPOST and to develop more advanced model‐based shake table controllers.
- 23 July 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (11) , 6041-6060
Damage identification of a reinforced concrete frame at increasing damage levels by sensitivity-based finite element model updating
- 23 July 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (11) , 6041-6060
Damage identification of a reinforced concrete frame at increasing damage levels by sensitivity-based finite element model updating
- 1 April 2019
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 33 (2)
System Identification of a Six-Span Steel Railway Bridge Using Ambient Vibration Measurements at Different Temperature Conditions
This paper presents modal parameter estimation work on a steel railway bridge at three different temperature conditions using ambient vibration test data. The bridge was built at the end of the 19th century using the available technology of its time. It is composed of six spans, each 30 m long, with a total length of 180 m. It is slightly curved in the horizontal plane with a radius of 300 m, and has a vertical grade of 2.5%. Modal parameters of the bridge were estimated using two different output-only system identification methods. The identified results obtained under different temperature conditions were compared in assessing the effects of temperature variation in the identification results. A comparative study in assessing method-to-method and test-to-test variability was also conducted. A three-dimensional finite-element model of the bridge was developed. In order to match the experimentally obtained modal parameters with the numerical ones, a trial-and-error–based model updating study was conducted. This way, a benchmark model of the 199+325 steel railway bridge was obtained for future capacity assessment, prediction, and sensitivity-based model updating work.
- 1 April 2019
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 33 (2)
System Identification of a Six-Span Steel Railway Bridge Using Ambient Vibration Measurements at Different Temperature Conditions
This paper presents modal parameter estimation work on a steel railway bridge at three different temperature conditions using ambient vibration test data. The bridge was built at the end of the 19th century using the available technology of its time. It is composed of six spans, each 30 m long, with a total length of 180 m. It is slightly curved in the horizontal plane with a radius of 300 m, and has a vertical grade of 2.5%. Modal parameters of the bridge were estimated using two different output-only system identification methods. The identified results obtained under different temperature conditions were compared in assessing the effects of temperature variation in the identification results. A comparative study in assessing method-to-method and test-to-test variability was also conducted. A three-dimensional finite-element model of the bridge was developed. In order to match the experimentally obtained modal parameters with the numerical ones, a trial-and-error–based model updating study was conducted. This way, a benchmark model of the 199+325 steel railway bridge was obtained for future capacity assessment, prediction, and sensitivity-based model updating work.