TNTin-Quoc Nguyen

Tin-Quoc Nguyen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tin-Quoc Nguyen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Pressure Difference Estimation in Non-stenotic Carotid Bifurcation Phantoms Using Vector Flow Imaging

    by Tin-Quoc Nguyen, Marie Sand Traberg, Jacob Bjerring Olesen, Ramin Moshavegh, Peter Hasse Møller-Sørensen, Lars Lönn, Jørgen Arendt Jensen, Michael Bachmann Nielsen, Kristoffer Lindskov Hansen


  • Open Access

    Transthoracic Vector Flow Imaging in Pediatric Patients with Valvular Stenosis – A Proof of Concept Study

    by Tin-Quoc Nguyen, Thor Bechsgaard, Michael Rahbek Schmidt, Klaus Juul, Ramin Moshavegh, Lars Lönn, Michael Bachmann Nielsen, Jørgen Arendt Jensen, Kristoffer Lindskov Hansen

    Purpose Continuous wave Doppler ultrasound is routinely used to detect cardiac valve stenoses. Vector flow imaging (VFI) is an angle-independent real-time ultrasound method that can quantify flow complexity. We aimed to evaluate if quantification of flow complexity could reliably assess valvular stenosis in pediatric patients. Materials and Methods Nine pediatric patients with echocardiographically confirmed valvular stenosis were included in the study. VFI and Doppler measurements were compared with transvalvular peak-to-peak pressure differences derived from invasive endovascular catheterization. Results Vector concentration correlated with the catheter measurements before intervention after exclusion of one outlier (r=−0.83, p=0.01), whereas the Doppler method did not (r=0.49, p=0.22). The change in vector concentration after intervention correlated strongly with the change in the measured catheter pressure difference (r=−0.86, p=0.003), while Doppler showed a tendency for a moderate correlation (r=0.63, p=0.07). Conclusion Transthoracic flow complexity quantification calculated from VFI data is feasible and may be useful for assessing valvular stenosis severity in pediatric patients.


  • Flow Complexity Estimation in Dysfunctional Arteriovenous Dialysis Fistulas using Vector Flow Imaging

    by Tin-Quoc Nguyen, Marie Sand Traberg, Jacob Bjerring Olesen, Søren Thorup Heerwagen, Andreas Hjelm Brandt, Thor Bechsgaard, Brian Lindegaard Pedersen, Ramin Moshavegh, Lars Lönn, Jørgen Arendt Jensen, et al.


  • Open Access

    Non-Invasive Assessment of Intravascular Pressure Gradients: A Review of Current and Proposed Novel Methods

    by Tin-Quoc Nguyen, Kristoffer Lindskov Hansen, Thor Bechsgaard, Lars Lönn, Jørgen Arendt Jensen, Michael Bachmann Nielsen

    Invasive catheterization is associated with a low risk of serious complications. However, although it is the gold standard for measuring pressure gradients, it induces changes to blood flow and requires significant resources. Therefore, non-invasive alternatives are urgently needed. Pressure gradients are routinely estimated non-invasively in clinical settings using ultrasound and calculated with the simplified Bernoulli equation, a method with several limitations. A PubMed literature search on validation of non-invasive techniques was conducted, and studies were included if non-invasively estimated pressure gradients were compared with invasively measured pressure gradients in vivo. Pressure gradients were mainly estimated from velocities obtained with Doppler ultrasound or magnetic resonance imaging. Most studies used the simplified Bernoulli equation, but more recent studies have employed the expanded Bernoulli and Navier–Stokes equations. Overall, the studies reported good correlation between non-invasive estimation of pressure gradients and catheterization. Despite having strong correlations, several studies reported the non-invasive techniques to either overestimate or underestimate the invasive measurements, thus questioning the accuracy of the non-invasive methods. In conclusion, more advanced imaging techniques may be needed to overcome the shortcomings of current methods.