Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Witold Chalupczak has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sparse Sensing and Machine Learning for Rapid Calibration of Defect Detection with rf Atomic Magnetometers

    by Marek J. Munko, Lucas M. Rushton, Laura M. Ellis, Jake D. Zipfel, Patrick Bevington, Witold Chalupczak, Sergio Lopez Dubon

    Machine learning algorithms are utilised to improve the speed of both image acquisition and calibration processes needed for defect detection using radio-frequency atomic magnetometers. Sparse sensing is employed, and an average relative error of ≈5% is observed for a reconstructed image based on 1.25% of the sampled pixels when compared to a raster scan over the target object. Additional algorithms demonstrate the viability of image processing to qualify results and adjust experimental parameters required for calibration, leading to an enhancement of image contrast. This presents a first step in developing a tool for fast, arbitrary defect detection.


  • Open Access

    Systematic nonuniform field effects in miniature atomic co-magnetometers

    by Laura Mae Ellis, Maitreyi Jayaseelan, Lucas Rushton, Jake David Zipfel, Patrick Bevington, Ben David George Steele, Greg Quick, Witold Chalupczak, Vera Guarrera

    Wafer-fabricated vapor cells are essential components in the development of scalable, field-deployable atomic sensing systems, including atomic spin gyroscopes. This paper presents a systematic study of magnetic resonance spectra obtained in a two-chamber, millimetre-sized, wafer-fabricated cell containing Cs, 129 Xe, 131 Xe, and N 2 buffer gas. For a range of vapor temperatures and pump powers, we identify characteristic structural and dynamical effects, including electric quadrupole splitting of the 131 Xe frequency and spectral branching of the 129 Xe frequency and linewidth as the signature of a Parity-Time (PT) symmetry-broken phase. Remarkably, we demonstrate that a primary class of systematic nonuniform field effects can be reduced to a simple one-dimensional linear gradient. We leverage these effects to offer regimes of optimised and robust sensor operation, setting a benchmark for the performance of wafer-fabricated vapor cells in both atomic spin gyroscopes and more broad quantum technologies.


  • Open Access

    Performance of a Radio-Frequency Two-Photon Atomic Magnetometer in Different Magnetic Induction Measurement Geometries

    by Lucas Martin Rushton, Laura Mae Ellis, Jake David Zipfel, Patrick Bevington, Witold Chalupczak

    Measurements monitoring the inductive coupling between oscillating radio-frequency magnetic fields and objects of interest create versatile platforms for non-destructive testing. The benefits of ultra-low-frequency measurements, i.e., below 3 kHz, are sometimes outweighed by the fundamental and technical difficulties related to operating pick-up coils or other field sensors in this frequency range. Inductive measurements with the detection based on a two-photon interaction in rf atomic magnetometers address some of these issues as the sensor gains an uplift in its operational frequency. The developments reported here integrate the fundamental and applied aspects of the two-photon process in magnetic induction measurements. In this paper, all the spectral components of the two-photon process are identified, which result from the non-linear interactions between the rf fields and atoms. For the first time, a method for the retrieval of the two-photon phase information, which is critical for inductive measurements, is also demonstrated. Furthermore, a self-compensation configuration is introduced, whereby high-contrast measurements of defects can be obtained due to its insensitivity to the primary field, including using simplified instrumentation for this configuration by producing two rf fields with a single rf coil.


  • Indirect pumping of alkali-metal gases in a miniature silicon-wafer cell

    by J.D. Zipfel, P. Bevington, L. Wright, W. Chalupczak, G. Quick, B. Steele, J. Nicholson, V. Guarrera

    Atom spin sensors occupy a prominent position in the landscape of quantum technology, as they can combine precise measurements with appealing miniature packages that are crucial for many applications. In this work, we report on the design and realization of miniature silicon-wafer cells, with a double-chamber configuration and integrated heaters. The cells are tested by our systematically studying the dependence of the spin dynamics on the main pump parameters, temperature, and bias magnetic field. The results are benchmarked against centimeter-sized paraffin-coated cells, which allows optimization of the operating conditions of a radio frequency–driven atomic magnetometer. In particular, we observe that, when indirect optical pumping is performed on the two cells, an analogous line-narrowing mechanism appears in otherwise-very-different cell conditions. Competitive results are obtained, with magnetic resonance linewidths of roughly 300 Hz at the maximum signal-to-noise ratio, in a nonzero-magnetic-field setting, and in an atomic shot noise–limited regime.


  • Polarization of radio-frequency magnetic fields in magnetic induction measurements with an atomic magnetometer

    by L.M. Rushton, L.M. Ellis, J.D. Zipfel, P. Bevington, W. Chalupczak

    We explore properties of the radio-frequency atomic magnetometer, specifically its sensitivity to the polarization of an oscillating magnetic field. This aspect can be particularly relevant to configurations where the sensor monitors fields created by more than one source. The discussion, illustrated by theoretical and experimental studies, is done in the context of the signals produced by electrically conductive and magnetically permeable plates in magnetic induction tomography measurements. We show that different components of the secondary magnetic fields create the object response depending on the properties of the material, with the polarization of the radio-frequency field varying across the object’s surface. We argue that the ability of the sensor to simultaneously detect different field components enables the optimization of measurement strategies for different object compositions.


  • Open Access

    Different Configurations of Radio-Frequency Atomic Magnetometers—A Comparative Study

    by Patrick Bevington, Witold Chalupczak

    We comprehensively explore different optical configurations of a radio-frequency atomic magnetometer in the context of sensor miniaturisation. Similarities and differences in operation principles of the magnetometer arrangements are discussed. Through analysis of the radio-frequency and noise spectra, we demonstrate that all configurations provide the same level of atomic polarisation and signal-to-noise ratio, but the optimum performance is achieved for significantly different laser powers and frequencies. We conclude with possible strategies for system miniaturisation.


  • Open Access

    Object Composition Identification by Measurement of Local Radio Frequency Magnetic Fields with an Atomic Magnetometer

    by Jake D. Zipfel, Srikant Santosh, Patrick Bevington, Witold Chalupczak

    Proof of principle of object composition identification based on inductive measurements with an atomic magnetometer has been demonstrated in highly engineered laboratory conditions. Progress in the development of portable miniaturised magnetometers has encouraged on the parallel development of the measurement technologies involving this sensor, in particular concepts that would enable operation in complex test scenarios. Here, we explore the problem of material identification in the context of measurements performed with variable distance between the object and the primary radio-frequency field source and sensor. We identify various aspects of the measurement affected by variable distance and discuss possible solutions, based on the signal phase analysis, a combination of frequency and angular signal dependencies and the implementation of a pair of excitation coils.


  • Role of the primary radio frequency magnetic field distribution in atomic magnetometer based inductive measurements

    by P. Bevington, L. Wright, R. Gartman, W. Chalupczak

    We explore the benefits of combining properties of the radio frequency atomic magnetometer, namely, its insensitive axis and the ability of vector field measurement, with the symmetry of the primary radio frequency field in inductive imaging of objects. In particular, we present the results of measurements performed with a pair of radio frequency magnetic field coils with the same and opposite polarities, i.e., in- and opposite-phases. Implementing different coil configurations enhances various features of the objects such as surfaces or edges and helps identify the object composition.


  • Object detection with an alkali-metal spin maser

    by P. Bevington, R. Gartman, W. Chalupczak

    We present magnetic induction tomography measurements performed with a radio-frequency atomic magnetometer operating in the spin maser mode. We discuss different regimes of spin maser operation that are defined by the gain within the system’s feedback, i.e., below threshold, unsaturated, and saturated gain. Two configurations are explored: first, where an rf field continuously drives the spin maser operation and the object’s presence changes the gain in the system’s feedback loop, and the second, where the spin maser operation is triggered and sustained directly by the object response. The advantages and disadvantages of each configuration are discussed in the context of object detection.


  • Identification of object composition with magnetic inductive tomography

    by R. Gartman, W. Chalupczak

    The inductive response of an object to an oscillating magnetic field reveals information about its electrical conductivity and magnetic permeability. Here, we introduce a technique that uses measurements of the angular, frequency, and spatial dependence of the inductive signal to determine the object composition. Identification is performed by referencing an object’s inductive response to that of materials with mutually exclusive properties such as copper (high electrical conductivity and negligible magnetic permeability) and ferrite (negligible electrical conductivity and high magnetic permeability). The technique uses a sensor with anisotropic sensitivity to discriminate between the different characters of the eddy current and magnetization driven object responses. Experimental validation of the method is performed using magnetic induction tomography measurement with a radio-frequency atomic magnetometer. Possible applications of the technique in security screening devices are discussed.