Ali Pakari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ali Pakari has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Saud Ghani
Department of Mechanical and Industrial Engineering, College of Engineering, Qatar University, P.O. Box 2713, Doha 2173, Qatar
7 shared publications Saud Ghani
Department of Mechanical and Industrial Engineering, College of Engineering, Qatar University, Doha, Qatar
1 shared publication
Latest Publications
- Open Access
- 14 March 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (19) , 10439-10459
Performance comparison of different flow arrangements of 4-fluid internally-cooled liquid desiccant dehumidifiers
In this study, the performance of 10 different flow arrangements of 4-fluid internally-cooled liquid desiccant dehumidifiers were compared. The four fluids are supply air, exhaust air, liquid desiccant, and water. The comparison was performed using a two-dimensional heat and mass transfer model of the dehumidifier that was solved numerically. The model’s predictions of supply air outlet humidity ratio matched experimental measurements within 6.7%. The two-dimensional variation of the air temperature and humidity ratio in the supply channel showed the importance of using a two-dimensional heat and mass transfer model when at least one of the fluids is in cross-flow with the other fluids. Moreover, a sensitivity analysis was performed to evaluate the effect of nine input parameters (supply air temperature and humidity ratio, exhaust air temperature and humidity ratio, liquid desiccant temperature, concentration, and flow rate, supply air mass flow rate, and exhaust to supply air mass flow rate ratio) on the performance of the dehumidifiers. The results showed that the best performance, in terms of the supply air humidity ratio and enthalpy decrease, was obtained when the supply air was in counter-flow with the exhaust air, liquid desiccant, and water. While the poorest performance was obtained when the supply air was in parallel-flow with the exhaust air and in counter-flow with the liquid desiccant and water. The approximate difference between the best and poorest performing flow arrangements in terms of the decrease in supply air humidity ratio and enthalpy is 4.3% and 10.5%, respectively. The results of the sensitivity analysis showed that for the 10 flow arrangements, the liquid desiccant inlet temperature, and flow rate have the least effects on the performance of the dehumidifier.
- 14 March 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (19) , 10439-10459
Open AccessPerformance comparison of different flow arrangements of 4-fluid internally-cooled liquid desiccant dehumidifiers
In this study, the performance of 10 different flow arrangements of 4-fluid internally-cooled liquid desiccant dehumidifiers were compared. The four fluids are supply air, exhaust air, liquid desiccant, and water. The comparison was performed using a two-dimensional heat and mass transfer model of the dehumidifier that was solved numerically. The model’s predictions of supply air outlet humidity ratio matched experimental measurements within 6.7%. The two-dimensional variation of the air temperature and humidity ratio in the supply channel showed the importance of using a two-dimensional heat and mass transfer model when at least one of the fluids is in cross-flow with the other fluids. Moreover, a sensitivity analysis was performed to evaluate the effect of nine input parameters (supply air temperature and humidity ratio, exhaust air temperature and humidity ratio, liquid desiccant temperature, concentration, and flow rate, supply air mass flow rate, and exhaust to supply air mass flow rate ratio) on the performance of the dehumidifiers. The results showed that the best performance, in terms of the supply air humidity ratio and enthalpy decrease, was obtained when the supply air was in counter-flow with the exhaust air, liquid desiccant, and water. While the poorest performance was obtained when the supply air was in parallel-flow with the exhaust air and in counter-flow with the liquid desiccant and water. The approximate difference between the best and poorest performing flow arrangements in terms of the decrease in supply air humidity ratio and enthalpy is 4.3% and 10.5%, respectively. The results of the sensitivity analysis showed that for the 10 flow arrangements, the liquid desiccant inlet temperature, and flow rate have the least effects on the performance of the dehumidifier.
- Open Access
Regression Models for Performance Prediction of Internally-Cooled Liquid Desiccant Dehumidifiers
In this study, using response surface methodology and central composite design, regression models were developed relating 12 input factors to the supply air outlet humidity ratio and temperature of 4-fluid internally-cooled liquid desiccant dehumidifiers. The selected factors are supply air inlet temperature, supply air inlet humidity ratio, exhaust air inlet temperature, exhaust air inlet humidity ratio, liquid desiccant inlet temperature, liquid desiccant concentration, liquid desiccant flow rate, supply air mass flow rate, the ratio of exhaust to supply air mass flow rate, the thickness of the channel, the channel length, and the channel width of the dehumidifier. The designed experiments were performed using a numerical two-dimensional heat and mass transfer model of the liquid desiccant dehumidifier. The numerical model predicted the measured values of the supply air outlet humidity ratio within 6.7%. The regression model’s predictions of the supply air outlet humidity ratio matched the numerical model’s predictions and measured values within 4.5% and 7.9%, respectively. The results showed that the input factors with the most significant effect on the dehumidifying process in order of significance from high to low are as follows: supply air inlet humidity ratio, liquid desiccant concertation, length of channels, and width of channels. The developed regression models provide a straightforward means for performance prediction and optimization of internally-cooled liquid desiccant dehumidifiers.
Open AccessRegression Models for Performance Prediction of Internally-Cooled Liquid Desiccant Dehumidifiers
In this study, using response surface methodology and central composite design, regression models were developed relating 12 input factors to the supply air outlet humidity ratio and temperature of 4-fluid internally-cooled liquid desiccant dehumidifiers. The selected factors are supply air inlet temperature, supply air inlet humidity ratio, exhaust air inlet temperature, exhaust air inlet humidity ratio, liquid desiccant inlet temperature, liquid desiccant concentration, liquid desiccant flow rate, supply air mass flow rate, the ratio of exhaust to supply air mass flow rate, the thickness of the channel, the channel length, and the channel width of the dehumidifier. The designed experiments were performed using a numerical two-dimensional heat and mass transfer model of the liquid desiccant dehumidifier. The numerical model predicted the measured values of the supply air outlet humidity ratio within 6.7%. The regression model’s predictions of the supply air outlet humidity ratio matched the numerical model’s predictions and measured values within 4.5% and 7.9%, respectively. The results showed that the input factors with the most significant effect on the dehumidifying process in order of significance from high to low are as follows: supply air inlet humidity ratio, liquid desiccant concertation, length of channels, and width of channels. The developed regression models provide a straightforward means for performance prediction and optimization of internally-cooled liquid desiccant dehumidifiers.
- Open Access
Energy Savings Resulting from Using a Near-Surface Earth-to-Air Heat Exchanger for Precooling in Hot Desert Climates
Given the substantial energy use for space cooling in buildings, integrating energy-efficient and sustainable cooling systems into buildings has become increasingly more important. Even though the cooling potential of a near-surface earth-to-air heat exchanger (EAHE) with grass cover was demonstrated in previous studies, the energy savings and environmental benefits resulting from using the EAHE have not yet been quantified. Therefore, in this study, we quantify the energy savings resulting from using a near-surface earth-to-air heat exchanger (EAHE) with grass-covered ground as a precooling unit in hot desert climates. The outlet air conditions of the EAHE during 9 months of the year (March to November), where space cooling is required, are predicted using a 3D transient CFD model, which is validated against field measurements. The EAHE is fabricated from a 1 mm thick aluminum tube with a diameter of 0.15 m and a length of 21.5 m, buried 0.4 m deep. The results showed that the EAHE can cool ambient air by up to 8.5 °C at an air flow rate of 607 m3/h, corresponding to a cooling capacity of 1700 W and a COP of 17. The daily average cooling capacity of the EAHE is about 560 W for an average operation period of 15.1 h per day. When used as a precooling unit for conventional cooling systems, the highest estimated monthly energy savings is 115 kWh, and the estimated annual savings is 741 kWh.
Open AccessEnergy Savings Resulting from Using a Near-Surface Earth-to-Air Heat Exchanger for Precooling in Hot Desert Climates
Given the substantial energy use for space cooling in buildings, integrating energy-efficient and sustainable cooling systems into buildings has become increasingly more important. Even though the cooling potential of a near-surface earth-to-air heat exchanger (EAHE) with grass cover was demonstrated in previous studies, the energy savings and environmental benefits resulting from using the EAHE have not yet been quantified. Therefore, in this study, we quantify the energy savings resulting from using a near-surface earth-to-air heat exchanger (EAHE) with grass-covered ground as a precooling unit in hot desert climates. The outlet air conditions of the EAHE during 9 months of the year (March to November), where space cooling is required, are predicted using a 3D transient CFD model, which is validated against field measurements. The EAHE is fabricated from a 1 mm thick aluminum tube with a diameter of 0.15 m and a length of 21.5 m, buried 0.4 m deep. The results showed that the EAHE can cool ambient air by up to 8.5 °C at an air flow rate of 607 m3/h, corresponding to a cooling capacity of 1700 W and a COP of 17. The daily average cooling capacity of the EAHE is about 560 W for an average operation period of 15.1 h per day. When used as a precooling unit for conventional cooling systems, the highest estimated monthly energy savings is 115 kWh, and the estimated annual savings is 741 kWh.
- 1 December 2019
- Published by Elsevier in Energy Conversion and Management
- Vol. 201
Performance evaluation of a near-surface earth-to-air heat exchanger with short-grass ground cover: an experimental study
- 1 December 2019
- Published by Elsevier in Energy Conversion and Management
- Vol. 201
Performance evaluation of a near-surface earth-to-air heat exchanger with short-grass ground cover: an experimental study
- 1 September 2019
- Published by Elsevier in Energy and Buildings
- Vol. 199, 1-11
Airflow assessment in a naturally ventilated greenhouse equipped with wind towers: numerical simulation and wind tunnel experiments
- 1 September 2019
- Published by Elsevier in Energy and Buildings
- Vol. 199, 1-11
Airflow assessment in a naturally ventilated greenhouse equipped with wind towers: numerical simulation and wind tunnel experiments
- 1 April 2019
- Published by Elsevier in Energy Conversion and Management
- Vol. 185, 562-573
Regression models for performance prediction of counter flow dew point evaporative cooling systems
- 1 April 2019
- Published by Elsevier in Energy Conversion and Management
- Vol. 185, 562-573
Regression models for performance prediction of counter flow dew point evaporative cooling systems
- 1 March 2019
- Published by Elsevier in Solar Energy
- Vol. 181, 234-242
Evaluation of a novel greenhouse design for reduced cooling loads during the hot season in subtropical regions
- 1 March 2019
- Published by Elsevier in Solar Energy
- Vol. 181, 234-242
Evaluation of a novel greenhouse design for reduced cooling loads during the hot season in subtropical regions