FAFahim Al-Neshawy

Fahim Al-Neshawy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fahim Al-Neshawy has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mechanical Properties and Microstructural Analysis of Concrete Designed for Low and Intermediate Level Nuclear Waste Repositories

    by Fahim Al-Neshawy, Abobaker Ba Ragaa

    This study investigates the mechanical properties and microstructural characteristics of five concrete mixtures specifically designed for application in low and intermediate-level nuclear waste repositories. These repositories necessitate construction materials that not only offer durability and strength but also maintain a long service-life under the underground environmental conditions over extended period. The concrete mix design was formulated with a focus on optimizing durability and sustainability, incorporating supplementary cementitious materials such as silica fume and slag to enhance the concrete durability. Comprehensive microstructural analyses using petrographic analysis and Micro x-ray fluorescence (μ-XRF) provided insights into the hydrate phases and pore structure evolution, revealing that the concrete exhibits dense microstructures and low permeability, essential for reducing leaching and sulfate attack risks. Mechanical testing demonstrated high compressive strength and modulus of elasticity, showing the suitability of concrete mixtures for structural components in repository environment. Overall, the findings highlight the potential of this designed concrete mixture in meeting the demands of low and intermediate level nuclear waste storage, ensuring safety and stability while also supporting environmental sustainability using eco-friendly materials.

  • Open Access

    In-situ Compressive Strength Assessment of Reinforced Concrete Structures

    by Fahim Al-Neshawy, Antti Wallenius, Jouni Punkki

    The strength of existing concrete structures can be evaluated and quantified where necessary with non-destructive and destructive testing methods. The aim is to determine the structural adequacy of existing concrete structures and to test the integrity of the concrete structures based on their strength evaluation. This paper investigates the procedure for the estimation of the in situ compressive strength and characteristic in situ compressive strength of concrete in structural components using direct methods (drilled core) and non-destructive testing methods using Ultra-sonic Pulse Velocity (UPV) and rebound hammers. By carrying out the experimental investigation, it helped us to create an understanding of the procedure of determining properties of the hardened reinforced concrete. The procedure should be done systematically, where analysing the results of the first preliminary examination can lead to the next needed examination method. As a result of this research, a flowchart was produced. The flowchart was produced in respect with standard EN 13791 [1] clause 8 and its Finnish application standard SFS 7508:2024 [2]. The scope of the flowchart was to introduce how many cores need to be extracted with possible indirect testing, considering the size of test region and the examination method.


  • Open Access

    Effect of Slag Content and Carbonation/Ageing on Freeze-Thaw Resistance of Concrete

    by Ahsan Iqbal, Teemu Ojala, Fahim Al-Neshawy, Jouni Punkki

    The construction industry is pursuing the reduction of CO2 emissions and the development of lowcarbon concrete. LOIKKA research project was initiated in Finland with the aim to reduce the CO2 emissions of concrete manufacturing by 50%. The use of blast furnace slag was seen as the most competitive way to significantly reduce CO2 emissions of concrete. However, incorporating slag in concrete can lead to durability complications, particularly concerning salt freeze-thaw resistance. This study investigates the effects of slag content, carbonation/ageing, and pre-curing conditions on the freeze-thaw and salt freeze-thaw resistance of concrete. Additionally, it evaluates the compressive strength development and porosity differences of test concretes. Slab tests were conducted to determine the surface scaling and internal damage resistance of concrete specimens. The results showed that high slag content and carbonation reduced salt freeze-thaw resistance. The incorporation of 50% slag content as the cement clinker replacement is considered critical. An increase in slag content led to a decrease in the compressive strength at 7 days due to the low reactivity of slag but achieved the highest compressive strength at 91 days with 70% slag content. These insights contribute to our understanding of the durability properties of concrete incorporating slag.


  • Open Access

    Determining the Location of Steel Reinforcement in Thick Concrete Walls by Non-Destructive Inspection

    by Fahim Al-Neshawy, Jari Puttonen

    Concrete cover is the thickness of the concrete layer that protects the reinforcing steel bars (rebar) within a reinforced concrete structure. It acts as a barrier against external elements such as moisture, chemicals, and environmental factors, safeguarding the rebar from corrosion. Concrete cover measurement is performed by using various nondestructive tests such as GPS (Ground Penetrating Radar), electromagnetic test and ultrasonic. The main benefit of the concrete cover thickness measurement is to explain the causes of corrosion and identify areas that have the capability to corrode faster. This paper discusses the possibilities to measure the concrete cover depth and determine the location of steel bars of a thick-walled concrete structure by using different nondestructive testing methods. The methods studied are a concrete cover meter, Ground Penetrating Radar, which is based on propagation radar waves in concrete, and Ultrasonic Pulse Echo tomography based on stress waves produced by ultrasonic pulses. The paper demonstrates the use of these methods for in-situ measurements on a thick-walled reinforced concrete structure. The concrete cover depth and the location for the reinforcement bars received by different methods are compared and the strong and weak points of the methods are discussed. The results indicate that the concrete cover meter is suitable for measuring the thickness of concrete cover, while the Ground Penetrating Radar and the Ultrasonic Pulse Echo device were able to identify and locate the reinforcement bars position in the concrete structure.

  • Open Access

    Investigation of the Internal Structure of Hardened 3D-Printed Concrete by X-CT Scanning and Its Influence on the Mechanical Performance

    by Yanjuan Chen, Jukka Kuva, Ashish Mohite, Zhongsen Li, Hubert Rahier, Fahim Al-Neshawy, Jiangpeng Shu

    As we know, 3DPC is printed layer by layer compared with mold-casting conventional concrete. Pore structure and layer-to-layer interface are two main aspects of the internal structure for 3DPC, which decide 3DPC’s mechanical performance. The layer-to-layer interface caused by printing is specific to 3DPC. The emphasis of this study lies in the layer-to-layer interfaces of 3DPC. The first aim of this study is to quantify the characteristics of the layer-to-layer interface and therefore characterize different aspects of the interfaces. The second aim of this study is to explore how the internal structure of printed concrete influences the mechanical performance of 3DPC. This research set out to design a series of experimental comparisons between 3DPC and casted concrete with the same compositions. Mechanical tests, i.e., compressive stress, ultrasonic Pulse Velocity test, flexural tension, and tension splitting, as well as the Ultrasonic Pulse Velocity test, were performed to check the mechanical performance of 3DPC. Contrary to what has often been expected, the mechanical test results showed the printed concrete has a quality not worse than casted concrete with the same recipe. Meanwhile, the X-ray computed tomography (X-CT) is used to characterize the internal structure, pore shapes, and interfaces of 3DPC. First, the investigation revealed that the lower total porosity and fewer big voids could be the fundamental causes meaning 3DPC has a better mechanical performance than casted concrete. Second, the statistics based on aspect ratio show that the distribution curves follow similar trends, regardless of the printed or casted concrete. Third, this study quantified the depth of the different interfaces for 3DPC. The results suggest that the porosity in an interface varies in a range. The author’s pioneer work has contributed to our present understanding of the interfaces of 3DPC.


  • Open Access

    Characteristics of Entrained Air Voids in Hardened Concrete with the Method of Digital Image Analysis Coupled with Schwartz-Saltykov Conversion

    by Teemu Ojala, Yanjuan Chen, Jouni Punkki, Fahim Al-Neshawy

    This paper presents the characteristics of air void systems in hardened concrete with the method of digital image analysis (DIA) coupled with Schwartz-Saltykov (SS) conversion. The results indicate that the DIA method coupled with SS conversion estimates the air content with more accuracy than it would without SS conversion; the correlation between air content obtained from the DIA method, and that from the thin section (TS) method is as good as the correlation observed between the pressure saturation (PS) method and the TS method. It was also found that the DIA method shows a better correlation with the TS method when the spacing factor without SS conversion is considered, while both methods show poor correlations when the corresponding specific surface is considered. In addition, it indicates that the peak of three-dimensional size distribution (3-DSD) of air voids after SS conversion falls in smaller voids, and 3-DSD of air voids shifts to a narrow size range, in comparison with the 2-DSD without SS conversion; the shape of the 3-DSD air voids remains constant irrespective of the class widths. Increasing the number of classes can minimise the standard deviation in the estimation, however, it also results in a leap in voids volume density, which will influence the estimation of air content.


  • Open Access

    Early Age Autogenous Shrinkage of Fibre Reinforced Concrete

    by Farid Ullah, Fahim Al-Neshawy, Jouni Punkki

    Concrete is often sensitive to cracking during the hardening process, and these cracks could be the result of early-age shrinkage. One method to reduce shrinkage is to add different types of fibres to concrete. The aim of this study was to study the effects of different types of fibres on the early-age autogenous shrinkage of concrete. Three different types of fibre materials were used in the research. A “Schleibinger Bending-drain” test setup was used to record early-age autogenous shrinkage of fresh concrete immediately after mixing. The results show that, a fibre dosage of 0.38% by volume was found to be effective in reducing the effects of early-age autogenous shrinkage of concrete.