YMYuan Mei

Yuan Mei

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuan Mei has a total of 140 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Demonstrating the Q-Pix front-end using discrete OpAmp and CMOS transistors

    by Peng Miao, Jonathan Asaadi, James B. R. Battat, Mikyung Han, Kevin Keefe, S. Kohani, Austin D. McDonald, David Nygren, Olivia Seidel, Yuan Mei

    Using Commercial Off-The-Shelf (COTS) Operational Amplifiers (OpAmps) and Complementary Metal-Oxide Semiconductor (CMOS) transistors, we present a demonstration of the Q-Pix front-end architecture, a novel readout solution for kiloton-scale Liquid Argon Time Projection Chamber (LArTPC) detectors. The Q-Pix scheme employs a Charge-Integrate/Reset process based on the Least Action principle, enabling pixel-scale self-triggering charge collection and processing, minimizing energy consumption, and maximizing data compression. We examine the architecture's sensitivity, linearity, noise, and other features at the circuit board level and draw comparisons to SPICE simulations. Furthermore, we highlight the resemblance between the Q-Pix front-end and Sigma-Delta modulator, emphasizing that digital data processing techniques for Sigma-Delta can be directly applied to Q-Pix, resulting in enhanced signal-to-noise performance. These insights will inform the development of Q-Pix front-end designs in integrated circuits (IC) and guide data collection and processing for future large-scale LArTPC detectors in neutrino physics and other high-energy physics experiments.

  • Open Access

    Topmetal CMOS direct charge sensing plane for neutrinoless double-beta decay search in high-pressure gaseous TPC

    by Yuan Mei, Xiangming Sun, Nu Xu

    We propose a novel charge sensing concept for high-pressure Time Projection Chamber (TPC) to search for Neutrinoless Double-Beta Decay (NLDBD) with ton-scale isotope mass and beyond. A meter-sized plane, tiled with an array of CMOS integrated sensors called Topmetal that directly collect charge without gas avalanche gain, is to be deployed into a high-pressure gaseous TPC with working gases containing suitable NLDBD candidate isotopes such as Xe-136 and Se-82. The Topmetal sensor has an electronic noise <30 e- per pixel, which allows the detector to reach <1% FWHM energy resolution at the NLDBD Q-value for both Xe-136 and 82SeF6 gases by measuring ionization charges alone. The elimination of charge avalanche gain allows the direct sensing of slow-drifting ions, which enables the use of highly electronegative gas SeF6 in which free electrons do not exist. It supports the swapping of working gases without hardware modification, which is a unique way to validate signals against radioactive backgrounds. Since the sensor manufacturing and plane assembling could leverage unaltered industrial mass-production processes, stability, uniformity, scalability, and cost-effectiveness that are required for ton-scale experiments could all be reached. The strengths of TPC such as 3D ionization tracking and decay daughter tagging are retained. This development could lead to a competitive NLDBD experiment at and above ton-scale. The conceptual considerations, simulations, and initial prototyping are discussed.

  • Open Access

    Results from the Cuore Experiment †

    by Alessio Caminata, Douglas Adams, Chris Alduino, Krystal Alfonso, Frank Avignone, Oscar Azzolini, Giacomo Bari, Fabio Bellini, Giovanni Benato, Andrea Bersani, et al.

    The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO 2 crystals arranged in a cylindrical compact structure of 19 towers, each of them made of 52 crystals. The construction of the experiment was completed in August 2016 and the data taking started in spring 2017 after a period of commissioning and tests. In this work we present the neutrinoless double beta decay results of CUORE from examining a total TeO 2 exposure of 86.3 kg yr , characterized by an effective energy resolution of 7.7 keV FWHM and a background in the region of interest of 0.014 counts / ( keV kg yr ) . In this physics run, CUORE placed a lower limit on the decay half-life of neutrinoless double beta decay of 130 Te > 1.3 · 10 25 yr (90% C.L.). Moreover, an analysis of the background of the experiment is presented as well as the measurement of the 130 Te 2 ν β β decay with a resulting half-life of T 1 / 2 2 ν = [ 7.9 ± 0.1 ( stat . ) ± 0.2 ( syst . ) ] × 10 20 yr which is the most precise measurement of the half-life and compatible with previous results.


  • Open Access

    Detailed study of the column-based priority logic readout of Topmetal-II- CMOS pixel direct charge sensor

    by Mangmang An, Chufeng Chen, Chaosong Gao, Mikyung Han, Guangming Huang, Rong Ji, Xiaoting Li, Yuan Mei, Hua Pei, Quan Sun, et al.

    We present the detailed study of the digital readout of Topmetal-II- CMOS pixel direct charge sensor. Topmetal-II- is an integrated sensor with an array of 72X72 pixels each capable of directly collecting external charge through exposed metal electrodes in the topmost metal layer. In addition to the time-shared multiplexing readout of the analog output from Charge Sensitive Amplifiers in each pixel, hits are also generated through comparators with individually DAC settable thresholds in each pixel. The hits are read out via a column-based priority logic structure, retaining both hit location and time information. The in-array column-based priority logic is fully combinational hence there is no clock distributed in the pixel array. Sequential logic and clock are placed on the peripheral of the array. We studied the detailed working behavior and performance of this readout, and demonstrated its potential in imaging applications.

  • Open Access

    A Low-Noise CMOS Pixel Direct Charge Sensor, Topmetal-II-

    by Mangmang An, Chufeng Chen, Chaosong Gao, Mikyung Han, Rong Ji, Xiaoting Li, Yuan Mei, Quan Sun, Xiangming Sun, Kai Wang, et al.

    We report the design and characterization of a CMOS pixel direct charge sensor, Topmetal-II-, fabricated in a standard 0.35um CMOS Integrated Circuit process. The sensor utilizes exposed metal patches on top of each pixel to directly collect charge. Each pixel contains a low-noise charge-sensitive preamplifier to establish the analog signal and a discriminator with tunable threshold to generate hits. The analog signal from each pixel is accessible through time-shared multiplexing over the entire array. Hits are read out digitally through a column-based priority logic structure. Tests show that the sensor achieved a <15e- analog noise and a 200e- minimum threshold for digital readout per pixel. The sensor is capable of detecting both electrons and ions drifting in gas. These characteristics enable its use as the charge readout device in future Time Projection Chambers without gaseous gain mechanism, which has unique advantages in low background and low rate-density experiments.

  • Open Access

    Development of a highly pixelated direct charge sensor, Topmetal-I, for ionizing radiation imaging

    by Yan Fan, Chaosong Gao, Guangming Huang, Xiaoting Li, Yuan Mei, Hua Pei, Quan Sun, Xiangming Sun, Dong Wang, Zhen Wang, et al.

    Using industrial standard 0.35{\mu}m CMOS Integrated Circuit process, we realized a highly pixelated sensor that directly collects charge via metal nodes placed on the top of each pixel and forms two dimensional images of charge cloud distribution. The first version, Topmetal-I, features a 64x64 pixel array of 80{\mu}m pitch size. Direct charge calibration reveals an average capacitance of 210fF per pixel. The charge collection noise is near the thermal noise limit. With the readout, individual pixel channels exhibit a most probable equivalent noise charge of 330e-.