Ahmed Fadhil Khudhair
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmed Fadhil Khudhair has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Mouyed Khudhair Hassan
3 shared publicationsAhmed S. Abbas
1 shared publication- Hani Khalil Ismail
Department of Chemistry, Faculty of Science and Health, Koya University, Koya, Iraq
1 shared publication Hasan F. Alesary
1 shared publication- Hasan Fisal Alesary
Applied Medical Sciences College, University of Kerbala, Karbala, Iraq
1 shared publication Hayder Hamied Mihsen
Department of Chemistry, College of Science, University of Karbala, Karbala, Iraq
1 shared publication
Latest Publications
- Open Access
- 1 December 2025
- Published by Universitas Gadjah Mada in Indonesian Journal of Chemistry
- Vol. 25 (6) , 1870
Graphene Oxide Functionalized Based on Dispersive Solid Phase Extraction of Vitamin B12 Spectrophotometric Determination in Pharmaceutical Samples
Sample treatment is crucial for detecting target compounds in complex matrices. Recently, graphene oxide (GO) and its composites have garnered attention as sorbents for sample preparation; however, their application in vitamin B12 (VB12) extraction has not been fully explored. In this study, a dispersive solid-phase extraction (D-SPE) method was developed for the spectrophotometric determination of VB12 in pharmaceutical samples using GO, chitosan (CTS), and a GO/CTS composite as sorbents. The materials were characterized using FTIR, XRD, BET, and FESEM. Extraction conditions were optimized, such as pH, sorbent amount, contact time, eluent type and volume, and desorption temperature. Under these conditions, the developed D-SPE method achieved linear calibration ranges of 0.05–15, 0.1–10, and 0.02–10 µg mL−1, with correlation coefficients of 0.9997, 0.9990, and 0.9998, respectively, after extracting VB12 with GO, CTS, and GO/CTS. The limits of quantification were in the range of 1.00–2.09 µg mL−1, with relative standard deviations of less than 0.11% (n = 3). Recoveries in pharmaceutical samples ranged from 95.1 to 112.8% (GO), 91.8 to 95.5% (CTS), and 87.5 to 103.8% (GO/CTS). These results demonstrate that the GO/CTS composite is an efficient and reliable adsorbent for extracting VB12 in pharmaceutical applications.
- 1 December 2025
- Published by Universitas Gadjah Mada in Indonesian Journal of Chemistry
- Vol. 25 (6) , 1870
Open AccessGraphene Oxide Functionalized Based on Dispersive Solid Phase Extraction of Vitamin B12 Spectrophotometric Determination in Pharmaceutical Samples
Sample treatment is crucial for detecting target compounds in complex matrices. Recently, graphene oxide (GO) and its composites have garnered attention as sorbents for sample preparation; however, their application in vitamin B12 (VB12) extraction has not been fully explored. In this study, a dispersive solid-phase extraction (D-SPE) method was developed for the spectrophotometric determination of VB12 in pharmaceutical samples using GO, chitosan (CTS), and a GO/CTS composite as sorbents. The materials were characterized using FTIR, XRD, BET, and FESEM. Extraction conditions were optimized, such as pH, sorbent amount, contact time, eluent type and volume, and desorption temperature. Under these conditions, the developed D-SPE method achieved linear calibration ranges of 0.05–15, 0.1–10, and 0.02–10 µg mL−1, with correlation coefficients of 0.9997, 0.9990, and 0.9998, respectively, after extracting VB12 with GO, CTS, and GO/CTS. The limits of quantification were in the range of 1.00–2.09 µg mL−1, with relative standard deviations of less than 0.11% (n = 3). Recoveries in pharmaceutical samples ranged from 95.1 to 112.8% (GO), 91.8 to 95.5% (CTS), and 87.5 to 103.8% (GO/CTS). These results demonstrate that the GO/CTS composite is an efficient and reliable adsorbent for extracting VB12 in pharmaceutical applications.
- Open Access
- 19 August 2024
- Published by College of Science for Women, University of Baghdad in Baghdad Science Journal
Liquid Phase Extraction and Determination of Chromium (III) Ion in Aqueous Solution Using Dithiocarbamate Derivative Reagent
تم تحضير الكاشف الجديد N-methyl-N - ((((4-bromophenyl) diazenyl) thio) carbonothioyl) aniline من تفاعل (sodium N-methyl- N-phenyl dithiocarbamate) مع (4-chlorobenzene diazonium salts). وشخص الكاشف الجديد بالطرائق الطيفية وهي، طيف الاشعة فوق البنفسجية، التحليل الدقيق للعناصر، طيف الاشعة تحت الحمراء، مطيافية الكتلة، مطيافية الرنين النووي المغناطيسي للبروتون والكاربون، التوصيلية المولارية والحساسية المغناطيسية. باستخدام البيانات التحليلية والطيفية، تم تحديد نسبة (الفلز: الكاشف)، ولوحظ أن المركب بنسبة1: 2 (فلز: كاشف). تم قياس التوصيلية المولية للمعقدات باستخدام DMF، وأظهرت النتائج أن المعقد الناتج كان أيونيا. تشير نتائج التحليل الدقيق للعناصر والدراسات الطيفية إلى أن المركب له بنية رباعية السطوح. تم تطوير الاستخلاص بنقطة الغيمة للتركيز المسبق وفصل الكروم الثلاثي في قياسات عينات الدواء باستخدام الامتصاص الذري للهب ومقياس الطيف الضوئي للأشعة فوق البنفسجية عند 536 نانومتر. تتأثر فعالية الاستخلاص بنقطة الغيمة بدرجة الحموضة، وتركيز Triton X-114 والكاشف، ونوع المادة الخافضة للتوتر السطحي، والتداخل، وتأثير الملح، والوقت، وتأثير درجة الحرارة. كان منحنى معايرة الكروم خطيًا في حدود 0.1-2 ميكروغرام مل-1 مع r2=0.9888. حد الكشف والتقدير الكمي هو (0.1246 و0.3777...
- 19 August 2024
- Published by College of Science for Women, University of Baghdad in Baghdad Science Journal
Open AccessLiquid Phase Extraction and Determination of Chromium (III) Ion in Aqueous Solution Using Dithiocarbamate Derivative Reagent
تم تحضير الكاشف الجديد N-methyl-N - ((((4-bromophenyl) diazenyl) thio) carbonothioyl) aniline من تفاعل (sodium N-methyl- N-phenyl dithiocarbamate) مع (4-chlorobenzene diazonium salts). وشخص الكاشف الجديد بالطرائق الطيفية وهي، طيف الاشعة فوق البنفسجية، التحليل الدقيق للعناصر، طيف الاشعة تحت الحمراء، مطيافية الكتلة، مطيافية الرنين النووي المغناطيسي للبروتون والكاربون، التوصيلية المولارية والحساسية المغناطيسية. باستخدام البيانات التحليلية والطيفية، تم تحديد نسبة (الفلز: الكاشف)، ولوحظ أن المركب بنسبة1: 2 (فلز: كاشف). تم قياس التوصيلية المولية للمعقدات باستخدام DMF، وأظهرت النتائج أن المعقد الناتج كان أيونيا. تشير نتائج التحليل الدقيق للعناصر والدراسات الطيفية إلى أن المركب له بنية رباعية السطوح. تم تطوير الاستخلاص بنقطة الغيمة للتركيز المسبق وفصل الكروم الثلاثي في قياسات عينات الدواء باستخدام الامتصاص الذري للهب ومقياس الطيف الضوئي للأشعة فوق البنفسجية عند 536 نانومتر. تتأثر فعالية الاستخلاص بنقطة الغيمة بدرجة الحموضة، وتركيز Triton X-114 والكاشف، ونوع المادة الخافضة للتوتر السطحي، والتداخل، وتأثير الملح، والوقت، وتأثير درجة الحرارة. كان منحنى معايرة الكروم خطيًا في حدود 0.1-2 ميكروغرام مل-1 مع r2=0.9888. حد الكشف والتقدير الكمي هو (0.1246 و0.3777...
- Open Access
- 29 May 2019
- Published by Universitas Gadjah Mada in Indonesian Journal of Chemistry
- Vol. 19 (3) , 638-649
A Simple Pre-concentration Method for the Determination of Nickel(II) in Urine Samples Using UV-Vis Spectrophotometry and Flame Atomic Absorption Spectrometry Techniques
The cloud point technique was effectively utilized for extraction and pre-concentration of nickel(II) in urine samples before measurement by UV-Vis spectrophotometer and AAS techniques. The metal response to a para-aminophenol (PAP) reagent in a non-ionic surfactant Triton X-114 medium was to form the Ni-PAP complex. The adopted concentration for PAP, concentration of Triton X-114, pH effect and water bath temperature, incubation time, salt effect, and interference effects were all optimized. The calibration curve was linear over the range of (0.0625–1.25) mg L–1 with a correlation coefficient r2 of 0.9682 for the UV-Vis spectrophotometer at a λmax of 629 nm. The limit of detection was 0.005 mg/L. The relative standard deviation for six replicates was 1.07%. This method was applied successfully to determine copper (II) concentrations in 44 urine samples of occupational worker samples as determined by UV-Vis spectrophotometry and FAAS techniques.
- 29 May 2019
- Published by Universitas Gadjah Mada in Indonesian Journal of Chemistry
- Vol. 19 (3) , 638-649
Open AccessA Simple Pre-concentration Method for the Determination of Nickel(II) in Urine Samples Using UV-Vis Spectrophotometry and Flame Atomic Absorption Spectrometry Techniques
The cloud point technique was effectively utilized for extraction and pre-concentration of nickel(II) in urine samples before measurement by UV-Vis spectrophotometer and AAS techniques. The metal response to a para-aminophenol (PAP) reagent in a non-ionic surfactant Triton X-114 medium was to form the Ni-PAP complex. The adopted concentration for PAP, concentration of Triton X-114, pH effect and water bath temperature, incubation time, salt effect, and interference effects were all optimized. The calibration curve was linear over the range of (0.0625–1.25) mg L–1 with a correlation coefficient r2 of 0.9682 for the UV-Vis spectrophotometer at a λmax of 629 nm. The limit of detection was 0.005 mg/L. The relative standard deviation for six replicates was 1.07%. This method was applied successfully to determine copper (II) concentrations in 44 urine samples of occupational worker samples as determined by UV-Vis spectrophotometry and FAAS techniques.
- Open Access
- 15 October 2018
- Published by Oriental Scientific Publishing Company in Oriental Journal of Chemistry
- Vol. 34 (5) , 2525-2533
Effects of Dopant Ions on the Properties of Polyaniline Conducting Polymer
This work will show, for the first time, the effect of nicotinic acid (NA) and 2-methylnicotinic acid (MNA)on the synthesis and properties of conducting polyaniline (PANI). The work investigates the effects of sulphuric acid (H2SO4), nicotinic acid (NA), and 2-methylnicotinic acid (MNA) on the synthesis and properties of polyaniline. The results show that the preparation of polyaniline from a sulphuric acid electrolyte is faster than the preparation from nicotinic acid and 2- methylnicotinic acid electrolytes. Moreover, the electrical conductivity and thermal stability of PANI/H2SO4 were greater than PANI/NA and PANI/MNA. All the polymers prepared in this study were identified using FT-IR. Scanning electron microscopy (SEM) was used to examine the morphologies of the PANI samples, from which it was determined that PANI/H2SO4 has a fibrous and open structure with a higher porosity morphology compared to PANI/NA and PANI/MNA. The electrical conductivities of the PANI samples were measured as 1.09 S cm-1, 0.65 S cm-1 and 0.089 S cm-1 for PANI/H2SO4, PANI/NA and PANI/MNA, respectively. The thermal stability of PANI was examined using the Thermogravimetric Analysis (TGA) technique. PANI/H2SO4 was found to degrade between 450-500°C, while PANI/NA and PANI/MNA decomposed at temperatures between 300-400°C.
- 15 October 2018
- Published by Oriental Scientific Publishing Company in Oriental Journal of Chemistry
- Vol. 34 (5) , 2525-2533
Open AccessEffects of Dopant Ions on the Properties of Polyaniline Conducting Polymer
This work will show, for the first time, the effect of nicotinic acid (NA) and 2-methylnicotinic acid (MNA)on the synthesis and properties of conducting polyaniline (PANI). The work investigates the effects of sulphuric acid (H2SO4), nicotinic acid (NA), and 2-methylnicotinic acid (MNA) on the synthesis and properties of polyaniline. The results show that the preparation of polyaniline from a sulphuric acid electrolyte is faster than the preparation from nicotinic acid and 2- methylnicotinic acid electrolytes. Moreover, the electrical conductivity and thermal stability of PANI/H2SO4 were greater than PANI/NA and PANI/MNA. All the polymers prepared in this study were identified using FT-IR. Scanning electron microscopy (SEM) was used to examine the morphologies of the PANI samples, from which it was determined that PANI/H2SO4 has a fibrous and open structure with a higher porosity morphology compared to PANI/NA and PANI/MNA. The electrical conductivities of the PANI samples were measured as 1.09 S cm-1, 0.65 S cm-1 and 0.089 S cm-1 for PANI/H2SO4, PANI/NA and PANI/MNA, respectively. The thermal stability of PANI was examined using the Thermogravimetric Analysis (TGA) technique. PANI/H2SO4 was found to degrade between 450-500°C, while PANI/NA and PANI/MNA decomposed at temperatures between 300-400°C.
- 1 January 2018
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 31 (2) , 353-359
Analysis and Cloud Point Extraction of Trace Copper (II) in Urine of Occupational Workers
- 1 January 2018
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 31 (2) , 353-359
Analysis and Cloud Point Extraction of Trace Copper (II) in Urine of Occupational Workers
- Open Access
- 1 January 2017
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 29 (5) , 1065-1068
Analysis of Strontium(II) Ion by Turbidimetric Method Using Schiff Base Derivative
- 1 January 2017
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 29 (5) , 1065-1068
Open AccessAnalysis of Strontium(II) Ion by Turbidimetric Method Using Schiff Base Derivative
- 1 January 2017
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 29 (12) , 2725-2733
Cloud Point Extraction and Determination of Trace Iron(III) in Urine Samples by Spectrophotometry and Flame Atomic Absorption Spectrometry
- 1 January 2017
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 29 (12) , 2725-2733
Cloud Point Extraction and Determination of Trace Iron(III) in Urine Samples by Spectrophotometry and Flame Atomic Absorption Spectrometry