Linda J. Olafsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Linda J. Olafsen has a total of 184 co-authors. Here are the top co-authors by number of shared publications:
I. Vurgaftman
U.S. Naval Research Lab. (United States)
17 shared publicationsH. Lee
Sarnoff Corp. (United States)
12 shared publicationsW. W. Bewley
U.S. Naval Research Lab. (United States)
12 shared publicationsC. L. Felix
Naval Research Laboratory Code 5613 Washington, District of Columbia 20375
11 shared publicationsJ. R. Meyer
U.S. Naval Research Lab. (United States)
11 shared publications- Donna W. Stokes
University of Houston
9 shared publications
Latest Publications
- Open Access
- 20 January 2026
- Published by Springer Nature in MRS Advances
- Vol. 11 (12) , 1-7
Shape memory alloy coil training toward guided electrode array insertion in cochlear implants
Current cochlear implant technology has limited capability to both safely insert the electrode array fully to the apex of the cochlea and laterally position the array precisely within the cochlea. The use of a programmable shape memory alloy guidewire has the potential to improve both electrode insertion depth and lateral placement control. The purpose of this study was to quantify the difference between trained and activated shapes of electrically actuated small-diameter Nitinol wires and thereby to refine a wire training methodology. Nitinol wires with 50–250 µm diameters were trained to form a coil shape, with training time varying from 30 s to 10 min. Measurements were taken at the training, activation, and relaxation stages of the wire. To obtain consistent coil shape, larger-diameter (150–250 µm) wires typically require 6 min of training time, while smaller-diameter (50–100 µm) wires require a longer training time, approximately 10 min. Graphical abstract
- 20 January 2026
- Published by Springer Nature in MRS Advances
- Vol. 11 (12) , 1-7
Open AccessShape memory alloy coil training toward guided electrode array insertion in cochlear implants
Current cochlear implant technology has limited capability to both safely insert the electrode array fully to the apex of the cochlea and laterally position the array precisely within the cochlea. The use of a programmable shape memory alloy guidewire has the potential to improve both electrode insertion depth and lateral placement control. The purpose of this study was to quantify the difference between trained and activated shapes of electrically actuated small-diameter Nitinol wires and thereby to refine a wire training methodology. Nitinol wires with 50–250 µm diameters were trained to form a coil shape, with training time varying from 30 s to 10 min. Measurements were taken at the training, activation, and relaxation stages of the wire. To obtain consistent coil shape, larger-diameter (150–250 µm) wires typically require 6 min of training time, while smaller-diameter (50–100 µm) wires require a longer training time, approximately 10 min. Graphical abstract
- 8 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 60 (2) , 1
Corrections to “Optical Pumping and Electrical Injection of a 3.6 μm Interband Cascade Laser” [Apr 22 1-8]
In the above article [1] , Fig. 7(b) duplicates Fig. 6(b). The correct Fig. 7(b) is shown as follows.
- 8 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 60 (2) , 1
Corrections to “Optical Pumping and Electrical Injection of a 3.6 μm Interband Cascade Laser” [Apr 22 1-8]
In the above article [1] , Fig. 7(b) duplicates Fig. 6(b). The correct Fig. 7(b) is shown as follows.
- Open Access
- 14 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 3, 18-24
Ultrasound Localization of Nitinol Wire of Sub-Wavelength Dimension
Goal: To enhance endovascular navigation using surgical guidewires and reduce the use of ionizing radiation, we demonstrate a method for ultrasonic localization of wires with diameters less than the wavelength of ultrasound in the medium. Methods: Nitinol wires with diameters ranging from 50 μm to 250 μm were imaged ultrasonically in a 0.25-in-diameter water-filled tube in a gelatin medium. Imaging frequencies were 5 MHz, 7.5 MHZ, and 10 MHz. Results: For the full range of diameters traversing the phantom, the wires were localized successfully via visual inspection of both regular and difference ultrasound images. Similarly, two convolutional neural networks were trained, and both achieved an accuracy of over 95%. Conclusions: Wires with diameters as small as 50 μm were localized successfully in a water-based gelatin phantom, indicating the potential use of ultrasound to enhance endovascular navigation and surgical treatment.
- 14 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 3, 18-24
Open AccessUltrasound Localization of Nitinol Wire of Sub-Wavelength Dimension
Goal: To enhance endovascular navigation using surgical guidewires and reduce the use of ionizing radiation, we demonstrate a method for ultrasonic localization of wires with diameters less than the wavelength of ultrasound in the medium. Methods: Nitinol wires with diameters ranging from 50 μm to 250 μm were imaged ultrasonically in a 0.25-in-diameter water-filled tube in a gelatin medium. Imaging frequencies were 5 MHz, 7.5 MHZ, and 10 MHz. Results: For the full range of diameters traversing the phantom, the wires were localized successfully via visual inspection of both regular and difference ultrasound images. Similarly, two convolutional neural networks were trained, and both achieved an accuracy of over 95%. Conclusions: Wires with diameters as small as 50 μm were localized successfully in a water-based gelatin phantom, indicating the potential use of ultrasound to enhance endovascular navigation and surgical treatment.
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 58 (2) , 1-8
Optical Pumping and Electrical Injection of a 3.6 μ m Interband Cascade Laser
We report results from optical pumping of an interband cascade laser (ICL), both with and without a monolayer graphene top contact. Optical pumping wavelengths from a Nd:YAG-pumped optical parametric oscillator were tuned from 1800 nm to 1950 nm. Lasing was demonstrated at a maximum temperature of 240 K for the ICL without graphene and 260 K for the ICL with graphene. The ICL emission wavelength was$3.6~\mu \text{m}$ at 200 K. Overall, threshold intensities were lower and slope efficiencies were higher for an optically-pumped ICL with a monolayer graphene top contact when compared to one without a graphene monolayer. Voltage-current analysis of a narrow-ridge, electrically-injected ICL from the same epitaxial growth evidenced differential resistance at threshold associated with quasi-Fermi-level pinning. Differential resistance values were approximately 10$\Omega $ at low temperature and$2~\Omega $ at 260 K, with corresponding pinning factors that correlate well with the slope efficiencies of both optically-pumped and electrically-injected ICL devices. Optical pumping is understood to result in carrier diffusion and generation of photovoltage and excess electrons to achieve lasing conditions.- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 58 (2) , 1-8
Optical Pumping and Electrical Injection of a 3.6 μ m Interband Cascade Laser
We report results from optical pumping of an interband cascade laser (ICL), both with and without a monolayer graphene top contact. Optical pumping wavelengths from a Nd:YAG-pumped optical parametric oscillator were tuned from 1800 nm to 1950 nm. Lasing was demonstrated at a maximum temperature of 240 K for the ICL without graphene and 260 K for the ICL with graphene. The ICL emission wavelength was$3.6~\mu \text{m}$ at 200 K. Overall, threshold intensities were lower and slope efficiencies were higher for an optically-pumped ICL with a monolayer graphene top contact when compared to one without a graphene monolayer. Voltage-current analysis of a narrow-ridge, electrically-injected ICL from the same epitaxial growth evidenced differential resistance at threshold associated with quasi-Fermi-level pinning. Differential resistance values were approximately 10$\Omega $ at low temperature and$2~\Omega $ at 260 K, with corresponding pinning factors that correlate well with the slope efficiencies of both optically-pumped and electrically-injected ICL devices. Optical pumping is understood to result in carrier diffusion and generation of photovoltage and excess electrons to achieve lasing conditions.- 1 March 2020
- Published by Elsevier in Infrared Physics & Technology
- Vol. 105
Multi-wavelength beam profile analysis of near-infrared nanosecond pulses
- 1 March 2020
- Published by Elsevier in Infrared Physics & Technology
- Vol. 105
Multi-wavelength beam profile analysis of near-infrared nanosecond pulses
- 26 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10868, 108681E
Current-controlled Nitinol wire for improved arterial navigation
Treatment of aneurysms and other neurological conditions would benefit from improved guidance of wires in arteries and the resulting reduction in time required to insert catheters and other imaging or treatment devices. By making a small opening in a blood vessel in the groin/upper thigh, arm, or neck, a catheter can be inserted with a guide wire to maneuver the catheter to the desired site. The ability to navigate arteries more accurately and thus insert a catheter more quickly would reduce the probability of aneurysm rupture and thus has the potential to reduce the rate of fatality or neurological deficit. This technology can also be used to treat complex aneurysms such as wide neck bifurcation aneurysms by angulating the neck of aneurysm temporarily. Nitinol is a shape memory alloy of nickel and titanium, with a long record of biocompatibility, particularly when an oxide and/or another passivating layer is applied. Nitinol coils have been used widely as stents because the alloy can be programmed to expand at human body temperatures and solidly fix to blood vessel walls. In this work, Nitinol wire is used with a programmed heat activation above body temperature, and thus guidance can be externally controlled using resistive heating. We present results of current-controlled steering of Nitinol wire, including the programming, control, and material response to varying current levels and pulse durations. We also demonstrate the viability of a light emitting diode attached to the guidewire with additional potential for image guidance, catheter navigation, and other treatment techniques.
- 26 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10868, 108681E
Current-controlled Nitinol wire for improved arterial navigation
Treatment of aneurysms and other neurological conditions would benefit from improved guidance of wires in arteries and the resulting reduction in time required to insert catheters and other imaging or treatment devices. By making a small opening in a blood vessel in the groin/upper thigh, arm, or neck, a catheter can be inserted with a guide wire to maneuver the catheter to the desired site. The ability to navigate arteries more accurately and thus insert a catheter more quickly would reduce the probability of aneurysm rupture and thus has the potential to reduce the rate of fatality or neurological deficit. This technology can also be used to treat complex aneurysms such as wide neck bifurcation aneurysms by angulating the neck of aneurysm temporarily. Nitinol is a shape memory alloy of nickel and titanium, with a long record of biocompatibility, particularly when an oxide and/or another passivating layer is applied. Nitinol coils have been used widely as stents because the alloy can be programmed to expand at human body temperatures and solidly fix to blood vessel walls. In this work, Nitinol wire is used with a programmed heat activation above body temperature, and thus guidance can be externally controlled using resistive heating. We present results of current-controlled steering of Nitinol wire, including the programming, control, and material response to varying current levels and pulse durations. We also demonstrate the viability of a light emitting diode attached to the guidewire with additional potential for image guidance, catheter navigation, and other treatment techniques.
- 19 May 2018
- Published by Springer Nature in Applied Physics B
- Vol. 124 (6) , 110
Time-dependent spatial intensity profiles of near-infrared idler pulses from nanosecond optical parametric oscillators
- 19 May 2018
- Published by Springer Nature in Applied Physics B
- Vol. 124 (6) , 110
Time-dependent spatial intensity profiles of near-infrared idler pulses from nanosecond optical parametric oscillators
- 4 February 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 86312N-86312N-8
Tunable excitation of mid-infrared optically pumped semiconductor lasers
- 4 February 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 86312N-86312N-8
Tunable excitation of mid-infrared optically pumped semiconductor lasers
- 23 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 17 (5) , 1453-1459
Nonlinear Temperature Dependence of Resonant Pump Wavelengths in Optical Pumping Injection Cavity Lasers
Type-II W optical pumping injection cavity lasers emitting ~3 μm at room temperature are pumped resonantly by tuning with an optical parametric oscillator. The resonance pump wavelength consistently is found to vary quadratically with temperature. Linear corrections to the lattice constant and index of refraction with temperature do not adequately account for this trend. Using multilayer reflectivity modeling, this nonlinear temperature dependence is attributed to gain-induced changes in the refractive index of the active region and spacer layers that result from the increase in optical pumping intensity with increasing temperature.
- 23 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 17 (5) , 1453-1459
Nonlinear Temperature Dependence of Resonant Pump Wavelengths in Optical Pumping Injection Cavity Lasers
Type-II W optical pumping injection cavity lasers emitting ~3 μm at room temperature are pumped resonantly by tuning with an optical parametric oscillator. The resonance pump wavelength consistently is found to vary quadratically with temperature. Linear corrections to the lattice constant and index of refraction with temperature do not adequately account for this trend. Using multilayer reflectivity modeling, this nonlinear temperature dependence is attributed to gain-induced changes in the refractive index of the active region and spacer layers that result from the increase in optical pumping intensity with increasing temperature.
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7953, 795314
Room-temperature 4.0-μm broadened optical pumping injection cavity lasers
The optical pumping injection cavity (OPIC) laser concept was developed to enhance the efficiency of optical pump beam absorption, and this work focuses on epitaxial configurations designed for broadband absorption around 1850 nm, an optimal pump wavelength for transmission through GaSb substrates that allows for epi-down mounting for improved heat management, while minimizing the photon decrement. The OPIC devices presented in this work have InAs/GaSb/InAs/AlSb type-II W active regions with a thicker GaSb/AlAsSb distributed Bragg reflector on top in order to enhance reflection back into the active region for epi-down mounting. Results are presented for optical pumping at 1850 nm as well as for resonant optical pumping, as the cavity resonance varies with temperature due to shifts in lattice constant, refractive index, and gain. Pumping at 1850 nm resulted in lasing from 78 K up through 310 K. At 78 K, the actual pump cavity resonance is ~1840 nm, and with increasing temperature the resonance shifts to longer wavelengths beyond 1850 nm. Emission wavelengths range from 3.59 μm at 78 K to 4.01 μm at 310 K for 1850 nm optical pumping. The broadened OPIC configuration presents a distinct advantage over earlier reported OPIC devices as the broader resonance allows for efficient emission across a wide temperature range for a single pump wavelength (e.g., 1850 nm), providing over 400 nm of wavelength tuning. Results will be compared with a second broadened OPIC with emission wavelengths beyond 4 μm that temperature tunes across the carbon dioxide spectral line at 4.2 μm.
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7953, 795314
Room-temperature 4.0-μm broadened optical pumping injection cavity lasers
The optical pumping injection cavity (OPIC) laser concept was developed to enhance the efficiency of optical pump beam absorption, and this work focuses on epitaxial configurations designed for broadband absorption around 1850 nm, an optimal pump wavelength for transmission through GaSb substrates that allows for epi-down mounting for improved heat management, while minimizing the photon decrement. The OPIC devices presented in this work have InAs/GaSb/InAs/AlSb type-II W active regions with a thicker GaSb/AlAsSb distributed Bragg reflector on top in order to enhance reflection back into the active region for epi-down mounting. Results are presented for optical pumping at 1850 nm as well as for resonant optical pumping, as the cavity resonance varies with temperature due to shifts in lattice constant, refractive index, and gain. Pumping at 1850 nm resulted in lasing from 78 K up through 310 K. At 78 K, the actual pump cavity resonance is ~1840 nm, and with increasing temperature the resonance shifts to longer wavelengths beyond 1850 nm. Emission wavelengths range from 3.59 μm at 78 K to 4.01 μm at 310 K for 1850 nm optical pumping. The broadened OPIC configuration presents a distinct advantage over earlier reported OPIC devices as the broader resonance allows for efficient emission across a wide temperature range for a single pump wavelength (e.g., 1850 nm), providing over 400 nm of wavelength tuning. Results will be compared with a second broadened OPIC with emission wavelengths beyond 4 μm that temperature tunes across the carbon dioxide spectral line at 4.2 μm.