KYKyoung Min Yoo

Kyoung Min Yoo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kyoung Min Yoo has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • EUV multilayer defect repair for advanced masks using rigorous aerial image-based modeling

    by Kyoung Min Yoo, Andrew M. C. Dawes, Joseph M. Rodriguez, Andrew Elliott, Rafaela Brinn, Arvind Sundaramurthy, Safak Sayan, Guangming Xiao

    As EUV mask requirements tighten, buried multilayer (ML) defects remain a critical challenge to imaging fidelity and yield, especially as designs evolve toward curvilinear patterns and advanced absorber stacks. In this work, we use rigorous electromagnetic simulations in Sentaurus Lithography (S-Litho) to compare the aerial image impact of buried ML defects on binary versus phase-shift EUV masks across absorber type, defect depth, and feature geometry. The calibrated defect models drive a constrained, model-guided repair flow that generates absorber-only compensation shapes compatible with e-beam repair tool limitations. We perform a comparative repair study spanning simple Manhattan, complex Manhattan, and fully curvilinear mask patterns, evaluating performance through-focus with EUV AIMS analysis to quantitatively compare critical dimension (CD) recovery, focus skew, and process window stability across mask types and repair strategies.

  • Lab-on-a-chip optical biosensor platform: a micro-ring resonator integrated with a near-infrared Fourier transform spectrometer

    by Kyoung Min Yoo, Kang-Chieh Fan, May Hlaing, Sourabh Jain, Shupeng Ning, Yue An, Ray T. Chen

    In this paper, we demonstrated the design and experimental results of the near-infrared lab-on-a-chip optical biosensor platform that monolithically integrates the MRR and the on-chip spectrometer on the silicon-on-insulator (SOI) wafer, which can eliminate the external optical spectrum analyzer for scanning the wavelength spectrum. The symmetric add-drop MRR biosensor is designed to have a free spectral range (FSR) of ∼19 nm and a bulk sensitivity of ∼73 nm/RIU; then the drop-port output resonance peaks are reconstructed from the integrated spatial-heterodyne Fourier transform spectrometer (SHFTS) with the spectral resolution of ∼3.1 nm and the bandwidth of ∼50 nm, which results in the limit of detection of 0.042 RIU.


  • Open Access

    Dual-Polarization Bandwidth-Bridged Bandpass Sampling Fourier Transform Spectrometer from Visible to Near-Infrared on a Silicon Nitride Platform

    by Kyoung Min Yoo, Ray T. Chen

    On-chip broadband optical spectrometers that cover the entire tissue transparency window (λ = 650-1050 nm) with high resolution are highly demanded for miniaturized biosensing and bioimaging applications. The standard spatial heterodyne Fourier transform spectrometer (SHFTS) requires a large number of Mach-Zehnder interferometer (MZI) arrays to obtain a broad spectral bandwidth while maintaining high resolution. Here, we propose a novel type of SHFTS integrated with a subwavelength grating coupler (SWGC) for the dual-polarization bandpass sampling on the Si3N4 platform to solve the intrinsic trade-off limitation between the bandwidth and resolution of the SHFTS without having an outrageous number of MZI arrays or adding additional active photonic components. By applying the bandpass sampling theorem, the continuous broadband input spectrum is divided into multiple narrow-band channels through tuning the phase-matching condition of the SWGC with different polarization and coupling angles. Thereby, it is able to reconstruct each band separately far beyond the Nyquist criterion without aliasing error or degrading the resolution. We experimentally demonstrated the broadband spectrum retrieval results with the overall bandwidth coverage of 400 nm, bridging the wavelengths from 650 to 1050 nm, with a resolution of 2-5 nm. The bandpass sampling SHFTS is designed to have 32 linearly unbalanced MZIs with the maximum optical path length difference of 93 μm within an overall footprint size of 4.7 mm × 0.65 mm, and the coupling angles of SWGC are varied from 0° to 32° to cover the entire tissue transparency window.


  • Open Access

    Fast, accurate, point-of-care COVID-19 pandemic diagnosis enabled through advanced lab-on-chip optical biosensors: Opportunities and challenges

    by Aref Asghari, Chao Wang, Kyoung Min Yoo, Ali Rostamian, Xiaochuan Xu, Jong-Dug Shin, Hamed Dalir, Ray T. Chen

    The sudden rise of the worldwide severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic in early 2020 has called into drastic action measures to perform instant detection and reduce the rate of spread. Common clinical and nonclinical diagnostic testing methods have been partially effective in satisfying the increasing demand for fast detection point-of-care (POC) methods to slow down further spread. However, accurate point-of-risk diagnosis of this emerging viral infection is paramount as the need for simultaneous standard operating procedures and symptom management of SARS-CoV-2 will be the norm for years to come. A sensitive, cost-effective biosensor with mass production capability is crucial until a universal vaccination becomes available. Optical biosensors can provide a noninvasive, extremely sensitive rapid detection platform with sensitivity down to ∼67 fg/ml (1 fM) concentration in a few minutes. These biosensors can be manufactured on a mass scale (millions) to detect the COVID-19 viral load in nasal, saliva, urine, and serological samples, even if the infected person is asymptotic. Methods investigated here are the most advanced available platforms for biosensing optical devices that have resulted from the integration of state-of-the-art designs and materials. These approaches include, but are not limited to, integrated optical devices, plasmonic resonance, and emerging nanomaterial biosensors. The lab-on-chip platforms examined here are suitable not only for SARS-CoV-2 spike protein detection but also for other contagious virions such as influenza and Middle East respiratory syndrome (MERS).


  • Optical phased array beam steering in the mid-infrared on an InP-based platform

    by Jason Midkiff, Kyoung Min Yoo, Jong-Dug Shin, Hamed Dalir, Mohammad Teimourpour, Ray T. Chen

    Compact, lightweight, high-power beam-steering devices operating in the mid-infrared atmospheric window λ = 3 − 5 µ m are attractive for aerial-based applications such as long-range lidar and countermeasures. In the near-infrared spectral region, optical phased arrays (OPAs) have emerged as the dominant nonmechanical on-chip beam-steering technology, with a preponderance in silicon-based platforms. Extensions to the mid-infrared spectral region are scarce. Further, considering that the requirements for high performance in this region will likely demand monolithic integration with quantum cascade lasers, development of the photonic technology on a native III–V platform is advantageous. To this end, at λ = 4.6 µ m , on an InGaAs/InP platform, we experimentally demonstrate the operation of a 32-channel OPA with thermo-optic tuning for azimuthal (lateral) steering. With a waveguide spacing of 2.5 λ , we steer the beam to the maximum uninfringed field of view at ± 11.5 ∘ .


  • InGaAs Membrane Waveguide: A Promising Platform for Monolithic Integrated Mid-Infrared Optical Gas Sensor

    by Kyoung Min Yoo, Jason Midkiff, Ali Rostamian, Chi-Jui Chung, Hamed Dalir, Ray T. Chen

    Mid-infrared (mid-IR) absorption spectroscopy based on integrated photonic circuits has shown great promise in trace-gas sensing applications in which the mid-IR radiation directly interacts with the targeted analyte. In this paper, considering monolithic integrated circuits with quantum cascade lasers (QCLs) and quantum cascade detectors (QCDs), the InGaAs-InP platform is chosen to fabricate passive waveguide gas-sensing devices. Fully suspended InGaAs waveguide devices with holey photonic crystal waveguides (HPCWs) and sub-wavelength grating cladding waveguides (SWWs) are designed and fabricated for mid-infrared sensing at λ=6.15µm in the low index contrast InGaAs-InP platform. We experimentally detect 5 ppm ammonia with a 1 mm long suspended HPCW and separately with a 3 mm long suspended SWW, with propagation losses of 39.1 dB/cm and 4.1 dB/cm, respectively. Furthermore, based on the Beer-Lambert infrared absorption law and the experimental results of discrete components, we estimated the minimum detectable gas concentration of 84 ppb from a QCL/QCD integrated SWW sensor. To the best of our knowledge, this is the first demonstration of suspended InGaAs membrane waveguides in the InGaAs-InP platform at such a long wavelength with gas sensing results. Also, this result emphasizes the advantage of SWWs to reduce the total transmission loss and the size of the fully integrated device’s footprint by virtue of its low propagation loss and TM mode compatibility in comparison to HPCWs. This study enables the possibility of monolithic integration of quantum cascade devices with TM-polarized characteristics and passive waveguide sensing devices for on-chip mid-IR absorption spectroscopy.


  • Open Access

    InP-based polarization rotator-splitter for mid-infrared photonic integration circuits

    by Chi-Jui Chung, Jason Midkiff, Kyoung Min Yoo, Ali Rostamian, Joel Guo, Ray T. Chen, Swapnajit Chakravarty

    We design and experimentally demonstrate the propagation loss of waveguides and the operation of a single-step etched polarization rotator-splitter (PRS) in low index contrast InGaAs-InP material system at 6.15 μm. Propagation losses 4.19 dB/cm for TM mode and 3.25 dB/cm for TE mode are measured. The designed PRS can achieve near 100% conversion efficiency. This study enables the possibility of monolithic integration of quantum cascade devices with TM-polarized characteristics and TE-guiding two-dimensional slotted photonic crystal waveguide gas sensors for on-chip monolithic absorption spectroscopy.