Sang-Hun Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sang-Hun Lee has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Seong-Mi Park
Department of Lift Engineering, Korea Lift College, Geochang, Korea
4 shared publications- Sung-Jun Park
Department of Electrical Engineering, Chonnam National University, Gwangju, South Korea
3 shared publications Feel-Soon Kang
2 shared publicationsSung-Jun Park
2 shared publicationsBae-Ho Lee
1 shared publicationChun-Sung Kim
1 shared publication
Latest Publications
- 8 January 2019
- Published by SAGE Publications in International Journal of Electrical Engineering & Education
- Vol. 57 (4) , 376-384
The stable transfer method using zero power control in the CTTS system
In the CTTS system, while transferring the power supply from the grid to the generator, a sudden arc arises, which causes damage to the system. The method proposed in this study reduces this damage. The power state of the generator stage is made equal to the state of the power of the grid in order to prevent the occurrence of a sudden arc. Even if the generator power state is the same with the power state of the generator, an arc can be generated due to a sudden current flow during the transfer. Therefore, the current in the generator stage is controlled to 0 (zero) when transferring, so that the generation of an electrical arc is minimized. In general, when the CTTS system is used for transferring power sources with an emergency generator, the impact from the electrical arc will be momentarily proportional to the amount of the power supplied from the generator to the load. The damage by the arc will make the life of the CTTS system shorter. In order to prevent such damage, a blocking technique using parallel capacitor is constituted. However, this causes arc generation at the time of input. Thus, in this paper, it is proposed to control the effective or ineffective power of the system to zero. To verify the validity of the proposed method, firstly the Powersim simulation was conducted, and after confirming the feasibility based on this, the actual prototype was created and implemented. Zero power control is proposed as a way to improve the stability of CTTS by significantly reducing the generation of an electrical arc. And this technique can help people working on the distributed power or the grid management.
- 8 January 2019
- Published by SAGE Publications in International Journal of Electrical Engineering & Education
- Vol. 57 (4) , 376-384
The stable transfer method using zero power control in the CTTS system
In the CTTS system, while transferring the power supply from the grid to the generator, a sudden arc arises, which causes damage to the system. The method proposed in this study reduces this damage. The power state of the generator stage is made equal to the state of the power of the grid in order to prevent the occurrence of a sudden arc. Even if the generator power state is the same with the power state of the generator, an arc can be generated due to a sudden current flow during the transfer. Therefore, the current in the generator stage is controlled to 0 (zero) when transferring, so that the generation of an electrical arc is minimized. In general, when the CTTS system is used for transferring power sources with an emergency generator, the impact from the electrical arc will be momentarily proportional to the amount of the power supplied from the generator to the load. The damage by the arc will make the life of the CTTS system shorter. In order to prevent such damage, a blocking technique using parallel capacitor is constituted. However, this causes arc generation at the time of input. Thus, in this paper, it is proposed to control the effective or ineffective power of the system to zero. To verify the validity of the proposed method, firstly the Powersim simulation was conducted, and after confirming the feasibility based on this, the actual prototype was created and implemented. Zero power control is proposed as a way to improve the stability of CTTS by significantly reducing the generation of an electrical arc. And this technique can help people working on the distributed power or the grid management.
- 1 December 2014
- Published by Journal of International Conference on Electrical Machines and Systems in Journal of international Conference on Electrical Machines and Systems
- Vol. 3 (4) , 422-427
Simple LED driver with Constant Current Control
- 1 December 2014
- Published by Journal of International Conference on Electrical Machines and Systems in Journal of international Conference on Electrical Machines and Systems
- Vol. 3 (4) , 422-427
Simple LED driver with Constant Current Control
- 1 December 2014
- Published by Journal of International Conference on Electrical Machines and Systems in Journal of international Conference on Electrical Machines and Systems
- Vol. 3 (4) , 415-421
Development of High Efficiency Boost DC/DC Converter For EV
- 1 December 2014
- Published by Journal of International Conference on Electrical Machines and Systems in Journal of international Conference on Electrical Machines and Systems
- Vol. 3 (4) , 415-421
Development of High Efficiency Boost DC/DC Converter For EV
- 20 April 2012
- Published by The Korean Institute of Power Electronics in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
- Vol. 17 (2) , 93-98
High Precise Measurement of Grid-Connected Inverter using DFT
- 20 April 2012
- Published by The Korean Institute of Power Electronics in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
- Vol. 17 (2) , 93-98
High Precise Measurement of Grid-Connected Inverter using DFT
- 20 October 2011
- Published by The Korean Institute of Power Electronics in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
- Vol. 16 (5) , 448-456
Design of LED Drive using MLCC Output Capacitor
- 20 October 2011
- Published by The Korean Institute of Power Electronics in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
- Vol. 16 (5) , 448-456
Design of LED Drive using MLCC Output Capacitor
- 20 February 2011
- Published by The Korean Institute of Power Electronics in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
- Vol. 16 (1) , 50-57
Load-Sharing Algorithm using Digital Parallel Communication
- 20 February 2011
- Published by The Korean Institute of Power Electronics in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
- Vol. 16 (1) , 50-57
Load-Sharing Algorithm using Digital Parallel Communication
- 1 April 2006
- Published by Elsevier in Electric Power Systems Research
- Vol. 76 (6) , 534-540
Single-stage power-factor-corrected converter for switched reluctance motor drive
- 1 April 2006
- Published by Elsevier in Electric Power Systems Research
- Vol. 76 (6) , 534-540
Single-stage power-factor-corrected converter for switched reluctance motor drive