Timur R. Mukhamadeev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Timur R. Mukhamadeev has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Gulnaz M. Idrisova
Department of Ophthalmology, Bashkir State Medical University, 3 Lenin Street, 450008 Ufa, Russia
7 shared publications - Ruslan V. Kutluyarov
School of Photonics Engineering and Research Advances (SPhERA), Ufa University of Science and Technology, 32 Z. Validi Street, 450076 Ufa, Russia
7 shared publications - T. I. Dibaev
Bashkir State Medical University
7 shared publications - Ekaterina A. Lopukhova
School of Photonics Engineering and Research Advances (SPhERA), Ufa University of Science and Technology, 32 Z. Validi Street, 450076 Ufa, Russia
6 shared publications - Elizaveta P. Grakhova
School of Photonics Engineering and Research Advances (SPhERA), Ufa University of Science and Technology, 32 Z. Validi Street, 450076 Ufa, Russia
6 shared publications - Bulat M. Aznabayev
Bashkir State Medical University
5 shared publications
Latest Publications
- Open Access
- 8 July 2026
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 23 (2) , 373-379
Digital Accommodative Asthenopia. Message 2: Accommodative Response Indicators in Adolescents with Different Screen Times
Purpose : to study the accommodative response indicators in adolescents with different screen time durations. Patients and methods . A clinical and experimental study involving 86 participants (16 males, 70 females; mean age 16.6 ± 0.17 years) consisted of two blocks of research. The psychometric block included the determination of internet-addiction (IA) and the nature and duration of digital information technology (DIT) use. The ophthalmology assessment included the determination of the accommodative response coefficient (ARC) and the accommodation lag (AL) using a Speedy-K autorefractometer (Right MFG, Japan); the data were analyzed using nonparametric statistical methods. This experimental approach allowed us to identify the relationship between the nature of DIT use, screen time (ST), and accommodation, as well as to gain insight into the neuro-ophthalmological mechanisms underlying digital accommodative asthenopia. Results . In the overall group of adolescents, the average level of IA was 50.0 (43.0; 60.0) points; signs of IA were not detected in 22.1 % (n = 19), 61.6 % (n = 53) showed IA in the formation stage; Internet addiction was identified in 16.3 % (n = 14), but we did not find any statistically significant patterns between IA and accommodative response indicators. Subjects had been using computers for 9.5 (8.0; 11.0) years, smartphones for 7.0 (5.0; 9.0) years, and the Internet for 8.0 (7.0; 10.0) years. Based on screen time duration (hours per day), subjects were divided into 4 groups: short (≤1 hour, n = 11), medium (1–3 hours, n = 26), long (4–6 hours, n = 20), and excessive (>6 hours, n = 17). Analysis of the obtained results revealed significant differences between the groups with different screen time durations for stimuli ranging from –1.5 to –3.0 D (p < 0.001 for most stimuli). A clear dose-dependent effect of screen time on the studied accommodative response parameters was demonstrated: with increasing screen time, the lag increases, and, accordingly, the accommodation coefficient decreases. The data are discussed from the perspective of modern neuro-ophthalmological approaches to the development of digital accommodative asthenopia (DAA), and taking into account the neurophysiological mechanisms of accommodation regulation.
- 8 July 2026
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 23 (2) , 373-379
Open AccessDigital Accommodative Asthenopia. Message 2: Accommodative Response Indicators in Adolescents with Different Screen Times
Purpose : to study the accommodative response indicators in adolescents with different screen time durations. Patients and methods . A clinical and experimental study involving 86 participants (16 males, 70 females; mean age 16.6 ± 0.17 years) consisted of two blocks of research. The psychometric block included the determination of internet-addiction (IA) and the nature and duration of digital information technology (DIT) use. The ophthalmology assessment included the determination of the accommodative response coefficient (ARC) and the accommodation lag (AL) using a Speedy-K autorefractometer (Right MFG, Japan); the data were analyzed using nonparametric statistical methods. This experimental approach allowed us to identify the relationship between the nature of DIT use, screen time (ST), and accommodation, as well as to gain insight into the neuro-ophthalmological mechanisms underlying digital accommodative asthenopia. Results . In the overall group of adolescents, the average level of IA was 50.0 (43.0; 60.0) points; signs of IA were not detected in 22.1 % (n = 19), 61.6 % (n = 53) showed IA in the formation stage; Internet addiction was identified in 16.3 % (n = 14), but we did not find any statistically significant patterns between IA and accommodative response indicators. Subjects had been using computers for 9.5 (8.0; 11.0) years, smartphones for 7.0 (5.0; 9.0) years, and the Internet for 8.0 (7.0; 10.0) years. Based on screen time duration (hours per day), subjects were divided into 4 groups: short (≤1 hour, n = 11), medium (1–3 hours, n = 26), long (4–6 hours, n = 20), and excessive (>6 hours, n = 17). Analysis of the obtained results revealed significant differences between the groups with different screen time durations for stimuli ranging from –1.5 to –3.0 D (p < 0.001 for most stimuli). A clear dose-dependent effect of screen time on the studied accommodative response parameters was demonstrated: with increasing screen time, the lag increases, and, accordingly, the accommodation coefficient decreases. The data are discussed from the perspective of modern neuro-ophthalmological approaches to the development of digital accommodative asthenopia (DAA), and taking into account the neurophysiological mechanisms of accommodation regulation.
- 29 June 2026
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 142 (3) , 13-21
Ultrastructural changes in the retina after microinvasive 25G ultrasound vitrectomy (experimental study)
Current trends in the development of vitrectomy systems, particularly vitreous cutters, focus on reducing instrument gauge while maintaining high cutting efficiency and vitreous fragmentation capacity. Pneumatic guillotine vitreous cutters have several design limitations that constrain further improvement of their functional capabilities. The use of ultrasonic energy for vitreous fragmentation represents an alternative direction in the development of vitrectomy. The emergence of microinvasive ultrasonic 25-gauge (25G) vitreous cutters creates the need for a comprehensive assessment of their effect on ultrastructure of the retina. Objective. The study investigated ultrastructural changes in the retina of rabbits after experimental microinvasive ultrasonic and pneumatic guillotine 25G vitrectomy. Material and methods. Rabbits in the main study group underwent microinvasive ultrasonic and pneumatic guillotine 25G vitrectomy. The retina was examined using electron microscopy. The data obtained in the experimental group, in which microinvasive ultrasonic vitrectomy was used, were then compared with the results of the control group, in which 25G pneumatic guillotine vitrectomy was performed. Results. On days 1 and 7, signs of retinal changes were detected in the inner nuclear layer and nerve fiber layer: vacuolization and fragmentation of neuronal cytoplasm, vacuolization of mitochondria, and elements of the rough endoplasmic reticulum. On days 14 and 30, some structural changes persisted — although the severity of the changes decreased. The nature of the changes in the experimental group was comparable with that in the control group and could be attributed not only to the identical effect of fragmentation, but also to nonspecific surgical trauma, hydrodynamic effects of fluid flow, changes associated with preparation of the material for electron microscopic examination, and individual tissue responses. Conclusion. The ultrastructural changes in the experimental group were similar in nature and severity to those observed in the control group. Therefore, microinvasive ultrasonic 25G vitrectomy can be considered a safe technology for vitreous fragmentation, with an effect on the retinal ultrastructure comparable to that of the traditional guillotine fragmentation method.
- 29 June 2026
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 142 (3) , 13-21
Ultrastructural changes in the retina after microinvasive 25G ultrasound vitrectomy (experimental study)
Current trends in the development of vitrectomy systems, particularly vitreous cutters, focus on reducing instrument gauge while maintaining high cutting efficiency and vitreous fragmentation capacity. Pneumatic guillotine vitreous cutters have several design limitations that constrain further improvement of their functional capabilities. The use of ultrasonic energy for vitreous fragmentation represents an alternative direction in the development of vitrectomy. The emergence of microinvasive ultrasonic 25-gauge (25G) vitreous cutters creates the need for a comprehensive assessment of their effect on ultrastructure of the retina. Objective. The study investigated ultrastructural changes in the retina of rabbits after experimental microinvasive ultrasonic and pneumatic guillotine 25G vitrectomy. Material and methods. Rabbits in the main study group underwent microinvasive ultrasonic and pneumatic guillotine 25G vitrectomy. The retina was examined using electron microscopy. The data obtained in the experimental group, in which microinvasive ultrasonic vitrectomy was used, were then compared with the results of the control group, in which 25G pneumatic guillotine vitrectomy was performed. Results. On days 1 and 7, signs of retinal changes were detected in the inner nuclear layer and nerve fiber layer: vacuolization and fragmentation of neuronal cytoplasm, vacuolization of mitochondria, and elements of the rough endoplasmic reticulum. On days 14 and 30, some structural changes persisted — although the severity of the changes decreased. The nature of the changes in the experimental group was comparable with that in the control group and could be attributed not only to the identical effect of fragmentation, but also to nonspecific surgical trauma, hydrodynamic effects of fluid flow, changes associated with preparation of the material for electron microscopic examination, and individual tissue responses. Conclusion. The ultrastructural changes in the experimental group were similar in nature and severity to those observed in the control group. Therefore, microinvasive ultrasonic 25G vitrectomy can be considered a safe technology for vitreous fragmentation, with an effect on the retinal ultrastructure comparable to that of the traditional guillotine fragmentation method.
- Open Access
- 29 March 2026
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 23 (1) , 117-122
Digital Accommodative Asthenopia. Results of the Screening Study of Subjective Manifestations of a Multidimensional Psychometric Scale in On-line Mode. Message 1
Purpose: to investigate the nature, intensity and frequency of the main subjective manifestations of digital accommodative asthenopia online, to determine their relationship with basic ophthalmoergonomic indicators. Design and research methods. The online screening study was conducted on 1310 students (average age 21.5 ± 0.1 years; 75.3 % of respondents were female, 24.7 % were male). The psychometric scale used contained 25 items from 5 questions reflecting the main symptoms of accommodative asthenopia, as well as ophthalmoergonomic questions. Results and discussion. The average work experience with mobile screen devices (MSD) was 10.29 ± 0.1 years. At the same time, the average daily duration, as well as the one-time duration of using the digital television, varied widely up to 1 hour and more than 6 hours. The average distance from the eyes to the screen was 36.0 ± 0.5 cm (from 5 to 120 cm). Complaints of varying intensity and nature were expressed by 74.6 % of respondents, with the maximum rating of “constantly” and “very strong” in the percentage of respondents: difficulty focusing at a distance (5.6 % and 5.7 % of respondents, respectively), eye strain when looking at the screen — 2.3 % and 2.7 %, fogginess and blurriness — 1.7 % and 1.2 % of respondents. There were no significant correlation between the length of use of devices and complaints of accommodation problems among the respondents surveyed. A positive weak but significant relationship was found between the indicators “duration of using the digital optics and digital electronic devices per session” and “duration of using the digital optics and digital electronic devices during the day” with complaints of strain when fixing the gaze on the screen, as well as with blurred vision and problems focusing into the distance. The absence of a significant correlation between the length of use of devices and accommodative complaints may indicate the inclusion of some kind of stable, reliable mechanisms of accommodation compensation by the type of long-term adaptation, masking the subjective manifestations of the digital accommodative asthenopia. On the contrary, complaints of accommodative asthenopia associated with the duration of use per session or during the day reflect urgent, “emergency” compensation mechanisms and are manifested more clearly in the form of corresponding complaints of visual discomfort. Conclusion. A conclusion is made about the adequacy and effectiveness of the methodological approach using a multidimensional scale in on-line mode for analyzing the subjective manifestations of digital accommodative asthenopia. The data confirm the important role of ophthalmoergonomic factors in the formation of digital accommodative asthenopia in information technology users.
- 29 March 2026
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 23 (1) , 117-122
Open AccessDigital Accommodative Asthenopia. Results of the Screening Study of Subjective Manifestations of a Multidimensional Psychometric Scale in On-line Mode. Message 1
Purpose: to investigate the nature, intensity and frequency of the main subjective manifestations of digital accommodative asthenopia online, to determine their relationship with basic ophthalmoergonomic indicators. Design and research methods. The online screening study was conducted on 1310 students (average age 21.5 ± 0.1 years; 75.3 % of respondents were female, 24.7 % were male). The psychometric scale used contained 25 items from 5 questions reflecting the main symptoms of accommodative asthenopia, as well as ophthalmoergonomic questions. Results and discussion. The average work experience with mobile screen devices (MSD) was 10.29 ± 0.1 years. At the same time, the average daily duration, as well as the one-time duration of using the digital television, varied widely up to 1 hour and more than 6 hours. The average distance from the eyes to the screen was 36.0 ± 0.5 cm (from 5 to 120 cm). Complaints of varying intensity and nature were expressed by 74.6 % of respondents, with the maximum rating of “constantly” and “very strong” in the percentage of respondents: difficulty focusing at a distance (5.6 % and 5.7 % of respondents, respectively), eye strain when looking at the screen — 2.3 % and 2.7 %, fogginess and blurriness — 1.7 % and 1.2 % of respondents. There were no significant correlation between the length of use of devices and complaints of accommodation problems among the respondents surveyed. A positive weak but significant relationship was found between the indicators “duration of using the digital optics and digital electronic devices per session” and “duration of using the digital optics and digital electronic devices during the day” with complaints of strain when fixing the gaze on the screen, as well as with blurred vision and problems focusing into the distance. The absence of a significant correlation between the length of use of devices and accommodative complaints may indicate the inclusion of some kind of stable, reliable mechanisms of accommodation compensation by the type of long-term adaptation, masking the subjective manifestations of the digital accommodative asthenopia. On the contrary, complaints of accommodative asthenopia associated with the duration of use per session or during the day reflect urgent, “emergency” compensation mechanisms and are manifested more clearly in the form of corresponding complaints of visual discomfort. Conclusion. A conclusion is made about the adequacy and effectiveness of the methodological approach using a multidimensional scale in on-line mode for analyzing the subjective manifestations of digital accommodative asthenopia. The data confirm the important role of ophthalmoergonomic factors in the formation of digital accommodative asthenopia in information technology users.
- Open Access
- 29 March 2026
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 23 (1) , 84-90
Evaluation of the Impact of Endoillumination Duration on Functional Outcomes and Safety in Vitreoretinal Surgery
The duration of endoillumination is considered a potential risk factor for phototoxic retinal damage during vitreoretinal surgeries. Despite the widespread use of modern lighting systems, clinical data on the effect of endoillumination duration on functional outcomes remain limited. Objective: to evaluate the impact of endoillumination duration on functional outcomes and the safety of vitreoretinal surgery. Patients and methods. The study included patients who underwent vitreoretinal surgeries for macular holes ( n = 31), retinal detachments ( n = 48), and epiretinal membranes ( n = 25). The duration of endoillumination, initial and postoperative bestcorrected visual acuity (BCVA), type of tamponade, and features of the surgical technique were assessed. Statistical analysis involved multivariate regression models to identify determinants of functional outcomes. Results. The duration of endoillumination did not have a statistically significant effect on BCVA at 12 months after surgery ( p > 0.05). Anatomical success was achieved in all cases. Functional outcomes were significantly influenced by initial visual acuity (in the macular hole group), type of tamponade, and performance of combined surgery with phacoemulsification (in the retinal detachment group) ( p < 0.05). No statistically significant factors were identified in the epiretinal membrane group. Conclusion. The obtained results indicate that the duration of endoillumination does not significantly affect the functional outcomes of vitreoretinal surgery, while the primary role remains with the initial anatomical and functional characteristics of the eye and the features of the surgical technique.
- 29 March 2026
- Published by PE Polunina Elizareta Gennadievna in Ophthalmology in Russia
- Vol. 23 (1) , 84-90
Open AccessEvaluation of the Impact of Endoillumination Duration on Functional Outcomes and Safety in Vitreoretinal Surgery
The duration of endoillumination is considered a potential risk factor for phototoxic retinal damage during vitreoretinal surgeries. Despite the widespread use of modern lighting systems, clinical data on the effect of endoillumination duration on functional outcomes remain limited. Objective: to evaluate the impact of endoillumination duration on functional outcomes and the safety of vitreoretinal surgery. Patients and methods. The study included patients who underwent vitreoretinal surgeries for macular holes ( n = 31), retinal detachments ( n = 48), and epiretinal membranes ( n = 25). The duration of endoillumination, initial and postoperative bestcorrected visual acuity (BCVA), type of tamponade, and features of the surgical technique were assessed. Statistical analysis involved multivariate regression models to identify determinants of functional outcomes. Results. The duration of endoillumination did not have a statistically significant effect on BCVA at 12 months after surgery ( p > 0.05). Anatomical success was achieved in all cases. Functional outcomes were significantly influenced by initial visual acuity (in the macular hole group), type of tamponade, and performance of combined surgery with phacoemulsification (in the retinal detachment group) ( p < 0.05). No statistically significant factors were identified in the epiretinal membrane group. Conclusion. The obtained results indicate that the duration of endoillumination does not significantly affect the functional outcomes of vitreoretinal surgery, while the primary role remains with the initial anatomical and functional characteristics of the eye and the features of the surgical technique.
- Open Access
- 8 January 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (1) , 36
A Hierarchical Deep Learning Architecture for Diagnosing Retinal Diseases Using Cross-Modal OCT to Fundus Translation in the Lack of Paired Data
The paper focuses on automated diagnosis of retinal diseases, particularly Age-related Macular Degeneration (AMD) and diabetic retinopathy (DR), using optical coherence tomography (OCT), while addressing three key challenges: disease comorbidity, severe class imbalance, and the lack of strictly paired OCT and fundus data. We propose a hierarchical modular deep learning system designed for multi-label OCT screening with conditional routing to specialized staging modules. To enable DR staging when fundus images are unavailable, we use cross-modal alignment between OCT and fundus representations. This approach involves training a latent bridge that projects OCT embeddings into the fundus feature space. We enhance clinical reliability through per-class threshold calibration and implement quality control checks for OCT-only DR staging. Experiments demonstrate robust multi-label performance (macro-F1 after per-class threshold calibration) and reliable calibration (ECE ), and OCT-only DR staging is feasible in 96.1% of cases that meet the quality control criterion.- 8 January 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (1) , 36
Open AccessA Hierarchical Deep Learning Architecture for Diagnosing Retinal Diseases Using Cross-Modal OCT to Fundus Translation in the Lack of Paired Data
The paper focuses on automated diagnosis of retinal diseases, particularly Age-related Macular Degeneration (AMD) and diabetic retinopathy (DR), using optical coherence tomography (OCT), while addressing three key challenges: disease comorbidity, severe class imbalance, and the lack of strictly paired OCT and fundus data. We propose a hierarchical modular deep learning system designed for multi-label OCT screening with conditional routing to specialized staging modules. To enable DR staging when fundus images are unavailable, we use cross-modal alignment between OCT and fundus representations. This approach involves training a latent bridge that projects OCT embeddings into the fundus feature space. We enhance clinical reliability through per-class threshold calibration and implement quality control checks for OCT-only DR staging. Experiments demonstrate robust multi-label performance (macro-F1 after per-class threshold calibration) and reliable calibration (ECE ), and OCT-only DR staging is feasible in 96.1% of cases that meet the quality control criterion. - Open Access
- 5 December 2025
- Published by MDPI AG in Preprints.org
A Hierarchical Deep Learning Architecture for OCT Diagnostics of Retinal Diseases and Their Complications Capable of Performing Cross-Modal OCT to Fundus Translation in the Absence of Paired Data
The paper presents a solution to the limited accuracy of automated diagnostics for retinal pathologies, such as diabetic retinopathy and age-related macular degeneration. These challenges arise from difficulties in modeling comorbidities, a reliance on paired multimodal data, and issues related to class imbalance. The proposed solution features a novel hierarchical deep learning architecture designed for multi-label classification of optical coherence tomography (OCT) data. This architecture facilitates cross-modal knowledge transfer from fundus images without the need for paired fundus images. It was accomplished through the modular specialization of the architecture and the application of contrast equalization, which creates a latent “bridge” between the OCT and fundus data. The results demonstrate that the proposed approach achieves high accuracy (macro-F1 score of 0.989) and good calibration (Expected Calibration Error of 2.1%) in classification and staging tasks. Notably, it eliminates the need for fundus images for diabetic retinopathy staging in 96.1% of cases and surpasses traditional monolithic architectures on the macro-AUROC metric.
- 5 December 2025
- Published by MDPI AG in Preprints.org
Open AccessA Hierarchical Deep Learning Architecture for OCT Diagnostics of Retinal Diseases and Their Complications Capable of Performing Cross-Modal OCT to Fundus Translation in the Absence of Paired Data
The paper presents a solution to the limited accuracy of automated diagnostics for retinal pathologies, such as diabetic retinopathy and age-related macular degeneration. These challenges arise from difficulties in modeling comorbidities, a reliance on paired multimodal data, and issues related to class imbalance. The proposed solution features a novel hierarchical deep learning architecture designed for multi-label classification of optical coherence tomography (OCT) data. This architecture facilitates cross-modal knowledge transfer from fundus images without the need for paired fundus images. It was accomplished through the modular specialization of the architecture and the application of contrast equalization, which creates a latent “bridge” between the OCT and fundus data. The results demonstrate that the proposed approach achieves high accuracy (macro-F1 score of 0.989) and good calibration (Expected Calibration Error of 2.1%) in classification and staging tasks. Notably, it eliminates the need for fundus images for diabetic retinopathy staging in 96.1% of cases and surpasses traditional monolithic architectures on the macro-AUROC metric.
- Open Access
- 18 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 10197
An Interpretable Clinical Decision Support System Aims to Stage Age-Related Macular Degeneration Using Deep Learning and Imaging Biomarkers
The use of intelligent clinical decision support systems (CDSS) has the potential to improve the accuracy and speed of diagnoses significantly. These systems can analyze a patient’s medical data and generate comprehensive reports that help specialists better understand and evaluate the current clinical scenario. This capability is particularly important when dealing with medical images, as the heavy workload on healthcare professionals can hinder their ability to notice critical biomarkers, which may be difficult to detect with the naked eye due to stress and fatigue. Implementing a CDSS that uses computer vision (CV) techniques can alleviate this challenge. However, one of the main obstacles to the widespread use of CV and intelligent analysis methods in medical diagnostics is the lack of a clear understanding among diagnosticians of how these systems operate. A better understanding of their functioning and of the reliability of the identified biomarkers will enable medical professionals to more effectively address clinical problems. Additionally, it is essential to tailor the training process of machine learning models to medical data, which are often imbalanced due to varying probabilities of disease detection. Neglecting this factor can compromise the quality of the developed CDSS. This article presents the development of a CDSS module focused on diagnosing age-related macular degeneration. Unlike traditional methods that classify diseases or their stages based on optical coherence tomography (OCT) images, the proposed CDSS provides a more sophisticated and accurate analysis of biomarkers detected through a deep neural network. This approach combines interpretative reasoning with highly accurate models, although these models can be complex to describe. To address the issue of class imbalance, an algorithm was developed to optimally select biomarkers, taking into account both their statistical and clinical significance. As a result, the algorithm prioritizes the selection of classes that ensure high model accuracy while maintaining clinically relevant responses generated by the CDSS module. The results indicate that the overall accuracy of staging age-related macular degeneration increased by 63.3% compared with traditional methods of direct stage classification using a similar machine learning model. This improvement suggests that the CDSS module can significantly enhance disease diagnosis, particularly in situations with class imbalance in the original dataset. To improve interpretability, the process of determining the most likely disease stage was organized into two steps. At each step, the diagnostician could visually access information explaining the reasoning behind the intelligent diagnosis, thereby assisting experts in understanding the basis for clinical decision-making.
- 18 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 10197
Open AccessAn Interpretable Clinical Decision Support System Aims to Stage Age-Related Macular Degeneration Using Deep Learning and Imaging Biomarkers
The use of intelligent clinical decision support systems (CDSS) has the potential to improve the accuracy and speed of diagnoses significantly. These systems can analyze a patient’s medical data and generate comprehensive reports that help specialists better understand and evaluate the current clinical scenario. This capability is particularly important when dealing with medical images, as the heavy workload on healthcare professionals can hinder their ability to notice critical biomarkers, which may be difficult to detect with the naked eye due to stress and fatigue. Implementing a CDSS that uses computer vision (CV) techniques can alleviate this challenge. However, one of the main obstacles to the widespread use of CV and intelligent analysis methods in medical diagnostics is the lack of a clear understanding among diagnosticians of how these systems operate. A better understanding of their functioning and of the reliability of the identified biomarkers will enable medical professionals to more effectively address clinical problems. Additionally, it is essential to tailor the training process of machine learning models to medical data, which are often imbalanced due to varying probabilities of disease detection. Neglecting this factor can compromise the quality of the developed CDSS. This article presents the development of a CDSS module focused on diagnosing age-related macular degeneration. Unlike traditional methods that classify diseases or their stages based on optical coherence tomography (OCT) images, the proposed CDSS provides a more sophisticated and accurate analysis of biomarkers detected through a deep neural network. This approach combines interpretative reasoning with highly accurate models, although these models can be complex to describe. To address the issue of class imbalance, an algorithm was developed to optimally select biomarkers, taking into account both their statistical and clinical significance. As a result, the algorithm prioritizes the selection of classes that ensure high model accuracy while maintaining clinically relevant responses generated by the CDSS module. The results indicate that the overall accuracy of staging age-related macular degeneration increased by 63.3% compared with traditional methods of direct stage classification using a similar machine learning model. This improvement suggests that the CDSS module can significantly enhance disease diagnosis, particularly in situations with class imbalance in the original dataset. To improve interpretability, the process of determining the most likely disease stage was organized into two steps. At each step, the diagnostician could visually access information explaining the reasoning behind the intelligent diagnosis, thereby assisting experts in understanding the basis for clinical decision-making.
- Open Access
- 17 August 2025
- Published by MDPI AG in Preprints.org
An Interpretable Clinical Decision Support System aims to stage Age-Related Macular Degeneration using deep learning and imaging biomarkers
The use of intelligent clinical decision support systems (CDSS) has the potential to improve the accuracy and speed of diagnoses significantly. These systems can analyze a patient's medical data and generate comprehensive reports that enable specialists to better understand and evaluate the current clinical scenario. It is essential when dealing with medical images, as the high workload on healthcare professionals can hinder their ability to notice critical biomarkers, which may be difficult to detect with the naked eye due to stress and fatigue. Implementing a CDSS that uses computer vision (CV) techniques can alleviate this challenge. However, one of the main obstacles to the widespread use of CV and intelligent analysis methods in medical diagnostics is the lack of a clear understanding of how these systems operate among diagnosticians. A better understanding of how these systems work and the reliability of the identified biomarkers will enable medical professionals to more effectively grasp clinical problems. Additionally, it is essential to tailor the training process of machine learning models to fit medical data, which is often imbalanced due to varying probabilities of disease detection. If this factor is neglected, the quality of the developed CDSS may suffer. This article discusses the development of the CDSS module, which focuses on diagnosing age-related macular degeneration. Unlike traditional methods that classify diseases or their stages based on optical coherence tomography (OCT) images, the CDSS provides a more sophisticated and accurate analysis of biomarkers detected through a deep neural network. This approach combines an interpretative reasoning process with highly accurate models, although these models can be complex to describe. To address the issue of class imbalance, an algorithm has been developed to optimally select biomarkers, taking into account both their statistical and clinical significance. As a result, the algorithm prioritizes selecting classes that ensure high model accuracy while maintaining a sufficient level of clinical relevance in the responses generated by the CDSS module. The results obtained from this algorithm indicate that the overall accuracy of staging age-related macular degeneration increased by 63.3\% compared to traditional methods of direct stage classification using a similar machine learning model. This improvement suggests that the CDSS module can significantly enhance the diagnosis of this disease, especially in situations where there is class imbalance in the original dataset. To improve interpretability, the process of determining the most likely stage of the disease was organized into two stages. At each stage, the diagnostician could visually access information that explained the reasoning behind the intelligent diagnosis, aiding the expert in understanding how to make clinical decisions.
- 17 August 2025
- Published by MDPI AG in Preprints.org
Open AccessAn Interpretable Clinical Decision Support System aims to stage Age-Related Macular Degeneration using deep learning and imaging biomarkers
The use of intelligent clinical decision support systems (CDSS) has the potential to improve the accuracy and speed of diagnoses significantly. These systems can analyze a patient's medical data and generate comprehensive reports that enable specialists to better understand and evaluate the current clinical scenario. It is essential when dealing with medical images, as the high workload on healthcare professionals can hinder their ability to notice critical biomarkers, which may be difficult to detect with the naked eye due to stress and fatigue. Implementing a CDSS that uses computer vision (CV) techniques can alleviate this challenge. However, one of the main obstacles to the widespread use of CV and intelligent analysis methods in medical diagnostics is the lack of a clear understanding of how these systems operate among diagnosticians. A better understanding of how these systems work and the reliability of the identified biomarkers will enable medical professionals to more effectively grasp clinical problems. Additionally, it is essential to tailor the training process of machine learning models to fit medical data, which is often imbalanced due to varying probabilities of disease detection. If this factor is neglected, the quality of the developed CDSS may suffer. This article discusses the development of the CDSS module, which focuses on diagnosing age-related macular degeneration. Unlike traditional methods that classify diseases or their stages based on optical coherence tomography (OCT) images, the CDSS provides a more sophisticated and accurate analysis of biomarkers detected through a deep neural network. This approach combines an interpretative reasoning process with highly accurate models, although these models can be complex to describe. To address the issue of class imbalance, an algorithm has been developed to optimally select biomarkers, taking into account both their statistical and clinical significance. As a result, the algorithm prioritizes selecting classes that ensure high model accuracy while maintaining a sufficient level of clinical relevance in the responses generated by the CDSS module. The results obtained from this algorithm indicate that the overall accuracy of staging age-related macular degeneration increased by 63.3\% compared to traditional methods of direct stage classification using a similar machine learning model. This improvement suggests that the CDSS module can significantly enhance the diagnosis of this disease, especially in situations where there is class imbalance in the original dataset. To improve interpretability, the process of determining the most likely stage of the disease was organized into two stages. At each stage, the diagnostician could visually access information that explained the reasoning behind the intelligent diagnosis, aiding the expert in understanding how to make clinical decisions.
- 28 May 2025
- Published by PANORAMA Publishing House in Vestnik Nevrologii, Psihiatrii i Nejrohirurgii (Bulletin of Neurology, Psychiatry and Neurosurgery)
- No. 6,p. 717-729
Neuropsychological analysis of problem use of digital technologies in adolescents. Message 2: event-related electroencephalography in emotional assessment of IAPS stimuli
Neuropsychological study of adolescents with varying severity of Internet-addicted behavior showed the highest (92.7 %; n=89) number of coincidences of subjective assessment of IAPS stimuli with reliable change of SS-EEG upon presentation of stimuli of neutral valence (image of chair according to IAPS). Directly opposite structure of coincidence/mismatch was determined during visual affective stimulation with device images (Apple laptop): coincidences accounted for 25.3 %; (n=24), and mismatches — for 74.7 %; (n=71). When presenting stimuli of positive and negative valence, the ratio was approximately the same: 83.3 % (n=80) / 16.7 % (n=16) and 85.4 % (n=82) / 14.6 % (n=14), respectively. The maximum number of significant changes in the SS-EEG was detected when presenting images of devices in the range of 8–13 Hz (α rhythm). The maximum (up to 4.7 ± 2.2 μV) drop in the amplitude of the α wave occurred in Internet-independent (II) adolescents, and the minimum (25.6 ± 7.6 μV) — in Internet addicts (IA). Comparison of these values between the IA and II groups against the background of visual stimulation revealed a significantly (p = 0.006) low alpha activity in Internet-independent adolescents relative to Internet addicts. The amplitude of the background theta rhythm was highest in the group of adolescents without signs of Internet addiction, with IAPS stimulation, as in the case of the α rhythm, a sixfold decrease in the amplitude of θ activity occurred in Internet-independent adolescents, which significantly exceeds its two-fold decrease in the group of Internet addicts. The maximum desynchronization reaction determined in adolescents without signs of Internet addiction indicates good preservation of emotional selection mechanisms. On the contrary, this indicator was the worst in adolescents with Internet addiction, which serves as a sign of tolerance or rigidity, less effective selection of emotionally significant visual stimuli. The combination of psychometric analysis of subjective assessment of emotionally significant IAPS stimuli with registration of event-related EEG serves as an effective neuropsychological tool for studying neuropsychic functions in users of information technologies. The results are discussed both from the standpoint of stress theory and taking into account neurophysiological data on Internet-dependent behavior. The authors believe that the main result of the study is revealing a significant contribution of the visual system to the pathogenesis of Internet addiction.
- 28 May 2025
- Published by PANORAMA Publishing House in Vestnik Nevrologii, Psihiatrii i Nejrohirurgii (Bulletin of Neurology, Psychiatry and Neurosurgery)
- No. 6,p. 717-729
Neuropsychological analysis of problem use of digital technologies in adolescents. Message 2: event-related electroencephalography in emotional assessment of IAPS stimuli
Neuropsychological study of adolescents with varying severity of Internet-addicted behavior showed the highest (92.7 %; n=89) number of coincidences of subjective assessment of IAPS stimuli with reliable change of SS-EEG upon presentation of stimuli of neutral valence (image of chair according to IAPS). Directly opposite structure of coincidence/mismatch was determined during visual affective stimulation with device images (Apple laptop): coincidences accounted for 25.3 %; (n=24), and mismatches — for 74.7 %; (n=71). When presenting stimuli of positive and negative valence, the ratio was approximately the same: 83.3 % (n=80) / 16.7 % (n=16) and 85.4 % (n=82) / 14.6 % (n=14), respectively. The maximum number of significant changes in the SS-EEG was detected when presenting images of devices in the range of 8–13 Hz (α rhythm). The maximum (up to 4.7 ± 2.2 μV) drop in the amplitude of the α wave occurred in Internet-independent (II) adolescents, and the minimum (25.6 ± 7.6 μV) — in Internet addicts (IA). Comparison of these values between the IA and II groups against the background of visual stimulation revealed a significantly (p = 0.006) low alpha activity in Internet-independent adolescents relative to Internet addicts. The amplitude of the background theta rhythm was highest in the group of adolescents without signs of Internet addiction, with IAPS stimulation, as in the case of the α rhythm, a sixfold decrease in the amplitude of θ activity occurred in Internet-independent adolescents, which significantly exceeds its two-fold decrease in the group of Internet addicts. The maximum desynchronization reaction determined in adolescents without signs of Internet addiction indicates good preservation of emotional selection mechanisms. On the contrary, this indicator was the worst in adolescents with Internet addiction, which serves as a sign of tolerance or rigidity, less effective selection of emotionally significant visual stimuli. The combination of psychometric analysis of subjective assessment of emotionally significant IAPS stimuli with registration of event-related EEG serves as an effective neuropsychological tool for studying neuropsychic functions in users of information technologies. The results are discussed both from the standpoint of stress theory and taking into account neurophysiological data on Internet-dependent behavior. The authors believe that the main result of the study is revealing a significant contribution of the visual system to the pathogenesis of Internet addiction.
- Open Access
- 13 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (4) , 1945
Hybrid Integent Staging of Age-Related Macular Degeneration for Decision-Making on Patient Management Tactics
Treatment efficacy for age-related macular degeneration relies on early diagnosis and precise determination of the disease stage. This involves analyzing biomarkers in retinal images, which can be challenging when handling a large flow of patients and can compromise the quality of healthcare services. Clinical decision support systems offer a solution to this issue by employing intelligent algorithms to recognize biomarkers and specify the age-related macular degeneration stage through the analysis of retinal images. However, different stages of age-related macular degeneration may exhibit similar biomarkers, complicating the application of intelligent algorithms. This article presents a hybrid and hierarchical classification method for solving these problems. By leveraging the hybrid structure of the classifier, we can effectively manage issues commonly encountered with medical datasets, such as class imbalance and strong correlations between variables. The modifications to the intelligent algorithm proposed in this work for staging age-related macular degeneration resulted in an increase in average accuracy, sensitivity, and specificity of 20% compared to initial values. The Cohen’s Kappa coefficient, used for consistency estimation between the regression model and expert assessments of the intermediate class severity, was 0.708, indicating a high level of agreement.
- 13 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (4) , 1945
Open AccessHybrid Integent Staging of Age-Related Macular Degeneration for Decision-Making on Patient Management Tactics
Treatment efficacy for age-related macular degeneration relies on early diagnosis and precise determination of the disease stage. This involves analyzing biomarkers in retinal images, which can be challenging when handling a large flow of patients and can compromise the quality of healthcare services. Clinical decision support systems offer a solution to this issue by employing intelligent algorithms to recognize biomarkers and specify the age-related macular degeneration stage through the analysis of retinal images. However, different stages of age-related macular degeneration may exhibit similar biomarkers, complicating the application of intelligent algorithms. This article presents a hybrid and hierarchical classification method for solving these problems. By leveraging the hybrid structure of the classifier, we can effectively manage issues commonly encountered with medical datasets, such as class imbalance and strong correlations between variables. The modifications to the intelligent algorithm proposed in this work for staging age-related macular degeneration resulted in an increase in average accuracy, sensitivity, and specificity of 20% compared to initial values. The Cohen’s Kappa coefficient, used for consistency estimation between the regression model and expert assessments of the intermediate class severity, was 0.708, indicating a high level of agreement.