Tetsuya Satoh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tetsuya Satoh has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Akio Kuroda
3 shared publicationsYasuharu Shinoda
3 shared publicationsYuji Murakami
3 shared publicationsKazutoshi Matsumura
Forensic Science Laboratory, Kumamoto Prefectural Police Headquarters, Chuo-ku, Japan
2 shared publicationsKenichi Noda
2 shared publications- Ryuichi Hirota
Program of Biotechnology, Graduate School of Integrated Sciences for Life, Hiroshima University, Japan
2 shared publications
Latest Publications
- 22 April 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (21) , 2703-2709
Detection of prostate-specific antigen in semen using DNA aptamers: an application of nucleic acid aptamers in forensic body fluid identification
We developed novel aptamer-based assays for semen identification and demonstrated that aptamers can be useful tools for body fluid identification.
- 22 April 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (21) , 2703-2709
Detection of prostate-specific antigen in semen using DNA aptamers: an application of nucleic acid aptamers in forensic body fluid identification
We developed novel aptamer-based assays for semen identification and demonstrated that aptamers can be useful tools for body fluid identification.
- 25 April 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 410 (18) , 4371-4378
Development of mRNA-based body fluid identification using reverse transcription loop-mediated isothermal amplification
Identifying body fluids from forensic samples can provide valuable evidence for criminal investigations. Messenger RNA (mRNA)-based body fluid identification was recently developed, and highly sensitive parallel identification using reverse transcription polymerase chain reaction (RT-PCR) has been described. In this study, we developed reverse transcription loop-mediated isothermal amplification (RT-LAMP) as a simple, rapid assay for identifying three common forensic body fluids, namely blood, semen, and saliva, and evaluated its specificity and sensitivity. Hemoglobin beta (HBB), transglutaminase 4 (TGM4), and statherin (STATH) were selected as marker genes for blood, semen, and saliva, respectively. RT-LAMP could be performed in a single step including both reverse transcription and DNA amplification under an isothermal condition within 60 min, and detection could be conveniently performed via visual fluorescence. Marker-specific amplification was performed in each assay, and no cross-reaction was observed among five representative forensically relevant body fluids. The detection limits of the assays were 0.3 nL, 30 nL, and 0.3 μL for blood, semen, and saliva, respectively, and their sensitivities were comparable with those of RT-PCR. Furthermore, RT-LAMP assays were applicable to forensic casework samples. It is considered that RT-LAMP is useful for body fluid identification.
- 25 April 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 410 (18) , 4371-4378
Development of mRNA-based body fluid identification using reverse transcription loop-mediated isothermal amplification
Identifying body fluids from forensic samples can provide valuable evidence for criminal investigations. Messenger RNA (mRNA)-based body fluid identification was recently developed, and highly sensitive parallel identification using reverse transcription polymerase chain reaction (RT-PCR) has been described. In this study, we developed reverse transcription loop-mediated isothermal amplification (RT-LAMP) as a simple, rapid assay for identifying three common forensic body fluids, namely blood, semen, and saliva, and evaluated its specificity and sensitivity. Hemoglobin beta (HBB), transglutaminase 4 (TGM4), and statherin (STATH) were selected as marker genes for blood, semen, and saliva, respectively. RT-LAMP could be performed in a single step including both reverse transcription and DNA amplification under an isothermal condition within 60 min, and detection could be conveniently performed via visual fluorescence. Marker-specific amplification was performed in each assay, and no cross-reaction was observed among five representative forensically relevant body fluids. The detection limits of the assays were 0.3 nL, 30 nL, and 0.3 μL for blood, semen, and saliva, respectively, and their sensitivities were comparable with those of RT-PCR. Furthermore, RT-LAMP assays were applicable to forensic casework samples. It is considered that RT-LAMP is useful for body fluid identification.
- 1 December 2009
- Published by Elsevier in Analytical Biochemistry
- Vol. 395 (2) , 161-165
Reciprocating-flow ATP amplification system for increasing the number of amplification cycles
- 1 December 2009
- Published by Elsevier in Analytical Biochemistry
- Vol. 395 (2) , 161-165
Reciprocating-flow ATP amplification system for increasing the number of amplification cycles
- 1 October 2009
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 142 (1) , 118-122
Continuous-flow ATP amplification system on a chip
- 1 October 2009
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 142 (1) , 118-122
Continuous-flow ATP amplification system on a chip
- 1 August 2008
- Published by Elsevier in Analytical Biochemistry
- Vol. 379 (1) , 116-120
Continuous-flow ATP amplification system for increasing the sensitivity of quantitative bioluminescence assay
- 1 August 2008
- Published by Elsevier in Analytical Biochemistry
- Vol. 379 (1) , 116-120
Continuous-flow ATP amplification system for increasing the sensitivity of quantitative bioluminescence assay
- 1 January 2004
- Published by Oxford University Press (OUP) in Bioscience, Biotechnology, and Biochemistry
- Vol. 68 (6) , 1216-1220
ATP Amplification for Ultrasensitive Bioluminescence Assay: Detection of a Single Bacterial Cell
We developed an ultrasensitive bioluminescence assay of ATP by employing (i) adenylate kinase (ADK) for converting AMP + ATP to two molecules of ADP, (ii) polyphosphate (polyP) kinase (PPK) for converting ADP back to ATP (ATP amplification), and (iii) a commercially available firefly luciferase. A highly purified PPK-ADK fusion protein efficiently amplified ATP, resulting in high levels of bioluminescence in the firefly luciferase reaction. The present method, which was approximately 10,000-fold more sensitive to ATP than the conventional bioluminescence assay, allowed us to detect bacterial contamination as low as one colony-forming unit (CFU) of Escherichia coli per assay.
- 1 January 2004
- Published by Oxford University Press (OUP) in Bioscience, Biotechnology, and Biochemistry
- Vol. 68 (6) , 1216-1220
ATP Amplification for Ultrasensitive Bioluminescence Assay: Detection of a Single Bacterial Cell
We developed an ultrasensitive bioluminescence assay of ATP by employing (i) adenylate kinase (ADK) for converting AMP + ATP to two molecules of ADP, (ii) polyphosphate (polyP) kinase (PPK) for converting ADP back to ATP (ATP amplification), and (iii) a commercially available firefly luciferase. A highly purified PPK-ADK fusion protein efficiently amplified ATP, resulting in high levels of bioluminescence in the firefly luciferase reaction. The present method, which was approximately 10,000-fold more sensitive to ATP than the conventional bioluminescence assay, allowed us to detect bacterial contamination as low as one colony-forming unit (CFU) of Escherichia coli per assay.