Zehui Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zehui Wu has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Yajing Liu
Capital Medical University
23 shared publicationsHualong Chen
Capital Medical University
20 shared publicationsXuebo Cheng
Capital Medical University
19 shared publicationsZeng Jiang
Beijing Institute of Brain Disorders, Beijing Key Laboratory of Innovation and Translation of Central Nervous System Radiopharmaceuticals
13 shared publicationsZiyue Yu
Beijing Institute of Brain Disorders, Beijing Key Laboratory of Innovation and Translation of Central Nervous System Radiopharmaceuticals
13 shared publicationsWei Zheng
Beijing Institute of Brain Disorders, Laboratory of Brain Disorders, Ministry of Science and Technology, Collaborative Innovation Center for Brain Disorders
11 shared publications
Latest Publications
- 23 September 2026
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 23 (10) , 5151-5160
First-In-Human PET Imaging of Synaptic Vesicle Glycoprotein 2A with [18F]BIBD-181: Automation, Biodistribution, Dosimetry, and Preliminary Application in Epilepsy
We report the first-in-human evaluation of [18F]BIBD-181, a novel SV2A tracer designed with a fluoropropyl side chain to enable mild, automated radiosynthesis. A fully automated cGMP-compliant production process was developed on a commercial synthesizer, yielding the tracer with >95% radiochemical purity and molar activity >130 GBq/μmol. In eight healthy volunteers, [18F]BIBD-181 demonstrated excellent safety, rapid brain penetration peaking at 15 s post-injection, and a regional uptake pattern consistent with known synaptic vesicle glycoprotein 2A (SV2A) distribution (pallidum SUV = 2.01 ± 0.57 at 30 min). The effective dose was 2.7 μSv/MBq, with predominant renal clearance and no detectable defluorination. In pilot epilepsy patients, [18F]BIBD-181 positron emission tomography (PET) results revealed focal SV2A reductions that were confined to the epileptogenic lesionsa sclerotic hippocampus in one patient and a focal cortical dysplasia (FCD) in anotherwhereas [18F]FDG showed either extensive ipsilateral temporal hypometabolism or concordant focal hypometabolism, suggesting that SV2A imaging may offer more precise lesion delineation, particularly when [18F]FDG abnormalities extend beyond the true epileptogenic zone. These findings establish [18F]BIBD-181 as a clinically practical SV2A PET tracer with favorable dosimetry, simplified production, and promising utility for epilepsy surgical planning, warranting further validation in larger cohorts.
- 23 September 2026
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 23 (10) , 5151-5160
First-In-Human PET Imaging of Synaptic Vesicle Glycoprotein 2A with [18F]BIBD-181: Automation, Biodistribution, Dosimetry, and Preliminary Application in Epilepsy
We report the first-in-human evaluation of [18F]BIBD-181, a novel SV2A tracer designed with a fluoropropyl side chain to enable mild, automated radiosynthesis. A fully automated cGMP-compliant production process was developed on a commercial synthesizer, yielding the tracer with >95% radiochemical purity and molar activity >130 GBq/μmol. In eight healthy volunteers, [18F]BIBD-181 demonstrated excellent safety, rapid brain penetration peaking at 15 s post-injection, and a regional uptake pattern consistent with known synaptic vesicle glycoprotein 2A (SV2A) distribution (pallidum SUV = 2.01 ± 0.57 at 30 min). The effective dose was 2.7 μSv/MBq, with predominant renal clearance and no detectable defluorination. In pilot epilepsy patients, [18F]BIBD-181 positron emission tomography (PET) results revealed focal SV2A reductions that were confined to the epileptogenic lesionsa sclerotic hippocampus in one patient and a focal cortical dysplasia (FCD) in anotherwhereas [18F]FDG showed either extensive ipsilateral temporal hypometabolism or concordant focal hypometabolism, suggesting that SV2A imaging may offer more precise lesion delineation, particularly when [18F]FDG abnormalities extend beyond the true epileptogenic zone. These findings establish [18F]BIBD-181 as a clinically practical SV2A PET tracer with favorable dosimetry, simplified production, and promising utility for epilepsy surgical planning, warranting further validation in larger cohorts.
- Open Access
- 14 September 2026
- Published by MDPI AG in Pharmaceuticals
- Vol. 19 (9) , 1457
Current Landscape of Glycogen Synthase Kinase-3β PET Tracers: Progress, Limitations, and Perspectives—A Narrative Review
Background/Objectives: Glycogen synthase kinase-3β (GSK-3β) serves as a crucial molecular target for Alzheimer’s disease and other neurological disorders. Positron emission tomography (PET) enables non-invasive quantification of GSK-3β in vivo, offering value for early diagnosis and mechanistic studies. However, despite two decades of effort, no GSK-3β PET tracer has yet entered clinical trials. Methods: This review systematically summarizes the radiochemical synthesis and preclinical evaluation of major GSK-3β tracer classes, comparing synthetic accessibility, target affinity, brain uptake, P-gp efflux, metabolic stability, radiometabolite profiles, and blocking experiments. The literature was systematically searched in PubMed and Web of Science databases (2005–2026). Several key obstacles impeding clinical progression of GSK-3β PET radiotracers are identified. Results: First, P-gp efflux markedly reduces brain tracer accumulation, rendering even sub-nanomolar high-affinity ligands ineffective for brain imaging. Second, interfering factors such as brain-penetrant radiometabolites of [11C]OCM-44 and the extremely low plasma free fraction of [18F]OCM-50 greatly impair the quantitative accuracy of tracer uptake. Third, the paradoxical increase in brain uptake of isonicotinamide tracers upon blocking remains an unresolved confounding factor. Moreover, rodent data fail to reliably predict tracer performance in higher species, and to date, no tracer has been directly validated against GSK-3β expression in patient brain tissue. Conclusions: This review proposes a tiered validation framework comprising four levels: assessment of P-gp efflux, metabolite-corrected arterial input function, low-affinity enantiomer controls, and human brain autoradiography. The framework provides a rigorous basis for screening candidates and a systematic reference for developing next-generation GSK-3β PET tracers.
- 14 September 2026
- Published by MDPI AG in Pharmaceuticals
- Vol. 19 (9) , 1457
Open AccessCurrent Landscape of Glycogen Synthase Kinase-3β PET Tracers: Progress, Limitations, and Perspectives—A Narrative Review
Background/Objectives: Glycogen synthase kinase-3β (GSK-3β) serves as a crucial molecular target for Alzheimer’s disease and other neurological disorders. Positron emission tomography (PET) enables non-invasive quantification of GSK-3β in vivo, offering value for early diagnosis and mechanistic studies. However, despite two decades of effort, no GSK-3β PET tracer has yet entered clinical trials. Methods: This review systematically summarizes the radiochemical synthesis and preclinical evaluation of major GSK-3β tracer classes, comparing synthetic accessibility, target affinity, brain uptake, P-gp efflux, metabolic stability, radiometabolite profiles, and blocking experiments. The literature was systematically searched in PubMed and Web of Science databases (2005–2026). Several key obstacles impeding clinical progression of GSK-3β PET radiotracers are identified. Results: First, P-gp efflux markedly reduces brain tracer accumulation, rendering even sub-nanomolar high-affinity ligands ineffective for brain imaging. Second, interfering factors such as brain-penetrant radiometabolites of [11C]OCM-44 and the extremely low plasma free fraction of [18F]OCM-50 greatly impair the quantitative accuracy of tracer uptake. Third, the paradoxical increase in brain uptake of isonicotinamide tracers upon blocking remains an unresolved confounding factor. Moreover, rodent data fail to reliably predict tracer performance in higher species, and to date, no tracer has been directly validated against GSK-3β expression in patient brain tissue. Conclusions: This review proposes a tiered validation framework comprising four levels: assessment of P-gp efflux, metabolite-corrected arterial input function, low-affinity enantiomer controls, and human brain autoradiography. The framework provides a rigorous basis for screening candidates and a systematic reference for developing next-generation GSK-3β PET tracers.
- Open Access
- 25 August 2026
- Published by Elsevier in SSRN Electronic Journal
Automated Radiosynthesis and Quality Evaluation of [18F]BIBD-181 for Translational SV2A PET Imaging
[18F]BIBD-181 is a positron emission tomography tracer targeting synaptic vesicle glycoprotein 2A (SV2A), a molecular marker of synaptic density. This study aimed to establish an automated production method for [18F]BIBD-181 on the CFN-MPS200 platform and to evaluate its production consistency, radiochemical stability, and principal quality attributes. No-carrier-added [18F]fluoride was used for nucleophilic radiofluorination of precursor 6a. Reaction times of 10, 12, and 15 min were evaluated at 95 °C, and semipreparative HPLC purification was explored using acetonitrile/water ratios of 1:1, 2:3, and 3:7 (v/v), each containing 0.5% acetic acid. Radiofluorination for 12 min using 1.0 mg of precursor, followed by purification with acetonitrile/water (2:3, v/v) at 2.0 mL/min, provided the most favorable overall performance. Under the selected conditions, six independent automated production runs were completed in 74.80 ± 2.75 min, affording a non-decay-corrected radiochemical yield of 10.42 ± 0.57% and a radiochemical purity of 97.74 ± 0.76%. The final product was colorless and clear, with a pH of 7.15 ± 0.19. Analytical HPLC confirmed the chromatographic identity of [18F]BIBD-181, with a relative retention time of 1.03 compared with the nonradioactive [19F]BIBD-181 reference standard. Radiochemical purity remained above the predefined acceptance criterion of 90% for at least 240 min at room temperature. GC-FID analysis determined an ethanol content of 7.61% (v/v) and a residual acetonitrile concentration of 407.6 ppm. All three bacterial endotoxin assays met their corresponding predefined acceptance criteria and assay-suitability requirements. These findings demonstrate that [18F]BIBD-181 can be reproducibly prepared using an integrated automated workflow with high radiochemical purity and satisfactory short-term stability. The established procedure provides a practical radiochemical basis for routine tracer preparation and further preclinical and translational evaluation of [18F]BIBD-181 for SV2A PET imaging.
- 25 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAutomated Radiosynthesis and Quality Evaluation of [18F]BIBD-181 for Translational SV2A PET Imaging
[18F]BIBD-181 is a positron emission tomography tracer targeting synaptic vesicle glycoprotein 2A (SV2A), a molecular marker of synaptic density. This study aimed to establish an automated production method for [18F]BIBD-181 on the CFN-MPS200 platform and to evaluate its production consistency, radiochemical stability, and principal quality attributes. No-carrier-added [18F]fluoride was used for nucleophilic radiofluorination of precursor 6a. Reaction times of 10, 12, and 15 min were evaluated at 95 °C, and semipreparative HPLC purification was explored using acetonitrile/water ratios of 1:1, 2:3, and 3:7 (v/v), each containing 0.5% acetic acid. Radiofluorination for 12 min using 1.0 mg of precursor, followed by purification with acetonitrile/water (2:3, v/v) at 2.0 mL/min, provided the most favorable overall performance. Under the selected conditions, six independent automated production runs were completed in 74.80 ± 2.75 min, affording a non-decay-corrected radiochemical yield of 10.42 ± 0.57% and a radiochemical purity of 97.74 ± 0.76%. The final product was colorless and clear, with a pH of 7.15 ± 0.19. Analytical HPLC confirmed the chromatographic identity of [18F]BIBD-181, with a relative retention time of 1.03 compared with the nonradioactive [19F]BIBD-181 reference standard. Radiochemical purity remained above the predefined acceptance criterion of 90% for at least 240 min at room temperature. GC-FID analysis determined an ethanol content of 7.61% (v/v) and a residual acetonitrile concentration of 407.6 ppm. All three bacterial endotoxin assays met their corresponding predefined acceptance criteria and assay-suitability requirements. These findings demonstrate that [18F]BIBD-181 can be reproducibly prepared using an integrated automated workflow with high radiochemical purity and satisfactory short-term stability. The established procedure provides a practical radiochemical basis for routine tracer preparation and further preclinical and translational evaluation of [18F]BIBD-181 for SV2A PET imaging.
- 18 February 2026
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 50 (12) , 5156-5166
Species-dependent aromatase imaging in rodents, blood–brain barrier permeability, and tumor visualization with a novel 18 F-labeled PET tracer, [18F]AromataPET-1
An aromatase tracer, [18F]AromataPET-1, is designed and applied to imaging of the brain and tumors.
- 18 February 2026
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 50 (12) , 5156-5166
Species-dependent aromatase imaging in rodents, blood–brain barrier permeability, and tumor visualization with a novel 18 F-labeled PET tracer, [18F]AromataPET-1
An aromatase tracer, [18F]AromataPET-1, is designed and applied to imaging of the brain and tumors.
- 14 January 2026
- Published by American Chemical Society (ACS) in Journal of Medicinal Chemistry
- Vol. 69 (3) , 2575-2598
Design, Synthesis, and Preclinical Evaluation of a PET Tracer Targeting Methionine Adenosyltransferase 2A
Methionine adenosyltransferase 2A (MAT2A) is an oncogenic enzyme overexpressed in multiple cancers, yet it lacks companion diagnostics for its clinical inhibitors. This study developed two novel MAT2A-targeted PET tracers: the 18F-labeled [18F]1d, derived from AZ-28, demonstrates rapid tumor uptake (equilibrium ∼20 min), high tumor-to-muscle ratio, and specific MAT2A binding in H1975 xenografts, though it shows some bone uptake due to defluorination; the 68Ga-labeled [68Ga]1s, based on AG-270, retains high MAT2A affinity (IC50 = 6.23 nM) and exhibits superior pharmacokinetics─low liver uptake, renal clearance, and high cellular internalization (80%). While [18F]1d (logP = 1.42) crosses the blood-brain barrier, [68Ga]1s (logP = -1.71) shows high in vivo stability. Molecular docking confirms key interactions with the MAT2A allosteric site. Both tracers provide promising tools for solid tumor diagnosis, treatment monitoring, and precision oncology.
- 14 January 2026
- Published by American Chemical Society (ACS) in Journal of Medicinal Chemistry
- Vol. 69 (3) , 2575-2598
Design, Synthesis, and Preclinical Evaluation of a PET Tracer Targeting Methionine Adenosyltransferase 2A
Methionine adenosyltransferase 2A (MAT2A) is an oncogenic enzyme overexpressed in multiple cancers, yet it lacks companion diagnostics for its clinical inhibitors. This study developed two novel MAT2A-targeted PET tracers: the 18F-labeled [18F]1d, derived from AZ-28, demonstrates rapid tumor uptake (equilibrium ∼20 min), high tumor-to-muscle ratio, and specific MAT2A binding in H1975 xenografts, though it shows some bone uptake due to defluorination; the 68Ga-labeled [68Ga]1s, based on AG-270, retains high MAT2A affinity (IC50 = 6.23 nM) and exhibits superior pharmacokinetics─low liver uptake, renal clearance, and high cellular internalization (80%). While [18F]1d (logP = 1.42) crosses the blood-brain barrier, [68Ga]1s (logP = -1.71) shows high in vivo stability. Molecular docking confirms key interactions with the MAT2A allosteric site. Both tracers provide promising tools for solid tumor diagnosis, treatment monitoring, and precision oncology.
- 7 November 2025
- Published by American Chemical Society (ACS) in Journal of Medicinal Chemistry
- Vol. 68 (22) , 24560-24578
Novel Pyridine-Based Fibroblast Activation Protein-Targeted Tracers: Design, Synthesis, and PET Imaging Evaluation for Tumors
To overcome the short tumor retention and nonspecific uptake of quinoline-based FAP inhibitors (e.g., FAP-46), we employed scaffold hopping to design novel phenylalanine-pyridyl-glycyl-prolamide derivatives. Among synthesized compounds (1a-i), multimeric derivatives 1h and 1i showed enhanced FAP affinity (IC50: 0.51 and 0.27 nM). In A549-FAP tumor models, [68Ga]1b exhibited higher tumor uptake (7.02% ID/g) and lower organ uptake than [68Ga]FAP-46, while [68Ga]1f demonstrated improved tumor retention (7.84% ID/g at 4 h) and high target-to-background ratios. [68Ga]1h/1i showed higher tumor uptake but increased nontarget accumulation. Specific FAP targeting was confirmed, and [68Ga]1f exhibited favorable hydrophilicity and stability. This work shows the phenylalanine-pyridyl-glycyl-prolamide scaffold is a viable alternative to quinoline-based ones, with [68Ga]1f promising for clinical PET imaging and [68Ga]1h/1i for radioligand therapy, providing a new direction for FAP-targeted radiopharmaceuticals.
- 7 November 2025
- Published by American Chemical Society (ACS) in Journal of Medicinal Chemistry
- Vol. 68 (22) , 24560-24578
Novel Pyridine-Based Fibroblast Activation Protein-Targeted Tracers: Design, Synthesis, and PET Imaging Evaluation for Tumors
To overcome the short tumor retention and nonspecific uptake of quinoline-based FAP inhibitors (e.g., FAP-46), we employed scaffold hopping to design novel phenylalanine-pyridyl-glycyl-prolamide derivatives. Among synthesized compounds (1a-i), multimeric derivatives 1h and 1i showed enhanced FAP affinity (IC50: 0.51 and 0.27 nM). In A549-FAP tumor models, [68Ga]1b exhibited higher tumor uptake (7.02% ID/g) and lower organ uptake than [68Ga]FAP-46, while [68Ga]1f demonstrated improved tumor retention (7.84% ID/g at 4 h) and high target-to-background ratios. [68Ga]1h/1i showed higher tumor uptake but increased nontarget accumulation. Specific FAP targeting was confirmed, and [68Ga]1f exhibited favorable hydrophilicity and stability. This work shows the phenylalanine-pyridyl-glycyl-prolamide scaffold is a viable alternative to quinoline-based ones, with [68Ga]1f promising for clinical PET imaging and [68Ga]1h/1i for radioligand therapy, providing a new direction for FAP-targeted radiopharmaceuticals.
- 8 October 2025
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 22 (11) , 7036-7051
Lipophilicity-Optimized PARP-1 Tracers: Minimizing Hepatic Retention for Enhanced Target-to-Background PET Imaging
Developing PARP-1-targeted PET tracers with high tumor-to-background contrast remains challenging. Herein, we report a dual-path optimization strategy to enhance the performance of PARP-1-targeted radiotracers by modulating lipophilicity and incorporating active targeting moieties. A series of 68Ga or 18F-labeled Olaparib derivatives (1a-h) were designed, synthesized, and evaluated. Among these, [68Ga]1c, featuring a DODAGA chelator with enhanced hydrophilicity (Clog p = -2.99 ± 0.07), demonstrated superior tumor uptake (SUV = 0.54 ± 0.02 at 30 min) and sustained retention (SUV = 0.51 ± 0.02 at 4 h), along with significantly improved tumor-to-muscle (T/M = 25.5 at 4 h) and tumor-to-liver (T/L = 7.28 at 4 h) ratios compared to [68Ga]DOTA-Olaparib in the 22Rv1 subcutaneous tumor model, and maintained high imaging contrast in the MDA-MB-468 subcutaneous tumor model (tumor-to-muscle ratios all >6.00, tumor-to-liver ratio peaking at 3.16 at 1 h). Competitive blocking studies confirmed PARP-1-specific binding, while biodistribution and cellular assays revealed renal clearance and efficient internalization. In contrast, amino acid-modified derivatives ([68Ga]1d-e, [18F]1g) showed reduced tumor uptake, suggesting limitations in transporter-mediated delivery. PEGylation of [68Ga]1c to yield [68Ga]1h further compromised target affinity, underscoring the sensitivity of PARP-1's binding pocket to steric perturbations. [68Ga]1c demonstrates promise for clinical translation, highlighting the importance of balancing hydrophilicity and molecular size in PARP-1 tracers design.
- 8 October 2025
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 22 (11) , 7036-7051
Lipophilicity-Optimized PARP-1 Tracers: Minimizing Hepatic Retention for Enhanced Target-to-Background PET Imaging
Developing PARP-1-targeted PET tracers with high tumor-to-background contrast remains challenging. Herein, we report a dual-path optimization strategy to enhance the performance of PARP-1-targeted radiotracers by modulating lipophilicity and incorporating active targeting moieties. A series of 68Ga or 18F-labeled Olaparib derivatives (1a-h) were designed, synthesized, and evaluated. Among these, [68Ga]1c, featuring a DODAGA chelator with enhanced hydrophilicity (Clog p = -2.99 ± 0.07), demonstrated superior tumor uptake (SUV = 0.54 ± 0.02 at 30 min) and sustained retention (SUV = 0.51 ± 0.02 at 4 h), along with significantly improved tumor-to-muscle (T/M = 25.5 at 4 h) and tumor-to-liver (T/L = 7.28 at 4 h) ratios compared to [68Ga]DOTA-Olaparib in the 22Rv1 subcutaneous tumor model, and maintained high imaging contrast in the MDA-MB-468 subcutaneous tumor model (tumor-to-muscle ratios all >6.00, tumor-to-liver ratio peaking at 3.16 at 1 h). Competitive blocking studies confirmed PARP-1-specific binding, while biodistribution and cellular assays revealed renal clearance and efficient internalization. In contrast, amino acid-modified derivatives ([68Ga]1d-e, [18F]1g) showed reduced tumor uptake, suggesting limitations in transporter-mediated delivery. PEGylation of [68Ga]1c to yield [68Ga]1h further compromised target affinity, underscoring the sensitivity of PARP-1's binding pocket to steric perturbations. [68Ga]1c demonstrates promise for clinical translation, highlighting the importance of balancing hydrophilicity and molecular size in PARP-1 tracers design.
- 19 September 2025
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 22 (10) , 6339-6348
[18F]BIBD-239: A First-in-Human PET Radiotracer with Dual Diagnostic Utility for Glioma Grading and Myocardial Imaging
To verify its application potential in the field of cardiac and cerebral disease diagnosis, the first human experiment of [18F]BIBD-239 was reported. Synthesized via a GMP-compliant automated process on a CFN-MPS200 synthesizer (per Chinese Pharmacopoeia 2020), it achieved radiochemical purity >95%, nondecay-corrected yield >15%, and molar activity >120 GBq/μmol (total synthesis time 80 ± 5 min) under optimized conditions (95 °C, 10 min). Preclinical studies in rats confirmed TSPO-specific binding. First-in-human studies (6 healthy volunteers, 1 high-grade glioma (HGG), 1 low-grade glioma (LGG)) showed it rapidly crossed the blood-brain barrier with low normal brain retention and high sustained myocardial uptake without in vivo defluorination. HGG had higher tumor-to-background ratios (3.09) than LGG (2.33), with uptake beyond MRI-enhanced regions, correlating with histopathology. The whole-body effective dose (0.0145 ± 0.0018 mSv/MBq) was lower than [18F]FDG. [18F]BIBD-239 has robust synthesis, favorable pharmacokinetics, and TSPO-specific binding, enabling dual utility in noninvasive glioma grading and glucose-independent myocardial imaging, supporting translation in neuro-oncology and cardiovascular assessment.
- 19 September 2025
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 22 (10) , 6339-6348
[18F]BIBD-239: A First-in-Human PET Radiotracer with Dual Diagnostic Utility for Glioma Grading and Myocardial Imaging
To verify its application potential in the field of cardiac and cerebral disease diagnosis, the first human experiment of [18F]BIBD-239 was reported. Synthesized via a GMP-compliant automated process on a CFN-MPS200 synthesizer (per Chinese Pharmacopoeia 2020), it achieved radiochemical purity >95%, nondecay-corrected yield >15%, and molar activity >120 GBq/μmol (total synthesis time 80 ± 5 min) under optimized conditions (95 °C, 10 min). Preclinical studies in rats confirmed TSPO-specific binding. First-in-human studies (6 healthy volunteers, 1 high-grade glioma (HGG), 1 low-grade glioma (LGG)) showed it rapidly crossed the blood-brain barrier with low normal brain retention and high sustained myocardial uptake without in vivo defluorination. HGG had higher tumor-to-background ratios (3.09) than LGG (2.33), with uptake beyond MRI-enhanced regions, correlating with histopathology. The whole-body effective dose (0.0145 ± 0.0018 mSv/MBq) was lower than [18F]FDG. [18F]BIBD-239 has robust synthesis, favorable pharmacokinetics, and TSPO-specific binding, enabling dual utility in noninvasive glioma grading and glucose-independent myocardial imaging, supporting translation in neuro-oncology and cardiovascular assessment.
- Open Access
- 9 January 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (1) , 66
Utilisation of the Innovative [18F]-Labelled Radiotracer [18F]-BIBD-071 Within HR+ Breast Cancer Xenograft Mouse Models
Background/Objectives: Aromatase plays a crucial role in the conversion of androgens to oestrogens and is often overexpressed in hormone-dependent tumours, particularly breast cancer. [18F]BIBD-071, which has excellent binding affinity for aromatase and good pharmacokinetics, has potential for the diagnosis and treatment of aromatase-related diseases. The MCF-7 cell line, which is hormone receptor-positive (HR+), was used in the assessment of the novel [18F]-labelled radiotracer [18F]BIBD-071 via positron emission tomography (PET) imaging of an HR+ breast cancer xenograft model. Methods: [18F]BIBD-071 was synthesised, radiolabelled, and then subjected to in vitro stability testing. MCF-7 cells were cultured and implanted into BALB/c nude mice to establish subcutaneous tumour models. MicroPET/CT imaging was conducted after injection of the tracer at 1 and 2 h, and a blocking study was also conducted using the aromatase inhibitor letrozole. A block experiment was used to prove the specificity of the probe. Biodistribution studies were performed at 0.5, 1, and 2 h post injection (p.i.). Immunofluorescence was used to assess aromatase expression in MCF-7 cells. Results: [18F]BIBD-071 showed excellent in vitro stability and specific uptake in an MCF-7 xenograft tumour model. MicroPET/CT imaging at 1 and 2 h p.i. revealed excellent tumour visualisation with a favourable tumour-to-background ratio. Biodistribution data revealed high tracer uptake in the liver, small intestine, and stomach, with significant washout from the bloodstream and tumour over time. The tumour uptakes at 0.5 h, 1 h, and 2 h were 3.84 ± 0.13, 2.5 ± 0.17, and 2.54 ± 0.32, respectively. The tumour uptake significantly decreased between 0.5 h and 1 h (p < 0.0001), whereas there was no significant difference between 1 and 2 h. The tumour/background ratios at 0.5 h, 1 h, and 2 h were 1.19 ± 0.03, 1.12 ± 0.17, and 1.42 ± 0.11, respectively. Immunofluorescence confirmed robust aromatase expression in MCF-7 cells, which was correlated with [18F]BIBD-071 tumour uptake. Conclusions: [18F]BIBD-071 is a promising PET tracer for diagnosing and monitoring HR+ breast cancer, warranting further research into hormone-dependent cancers.
- 9 January 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (1) , 66
Open AccessUtilisation of the Innovative [18F]-Labelled Radiotracer [18F]-BIBD-071 Within HR+ Breast Cancer Xenograft Mouse Models
Background/Objectives: Aromatase plays a crucial role in the conversion of androgens to oestrogens and is often overexpressed in hormone-dependent tumours, particularly breast cancer. [18F]BIBD-071, which has excellent binding affinity for aromatase and good pharmacokinetics, has potential for the diagnosis and treatment of aromatase-related diseases. The MCF-7 cell line, which is hormone receptor-positive (HR+), was used in the assessment of the novel [18F]-labelled radiotracer [18F]BIBD-071 via positron emission tomography (PET) imaging of an HR+ breast cancer xenograft model. Methods: [18F]BIBD-071 was synthesised, radiolabelled, and then subjected to in vitro stability testing. MCF-7 cells were cultured and implanted into BALB/c nude mice to establish subcutaneous tumour models. MicroPET/CT imaging was conducted after injection of the tracer at 1 and 2 h, and a blocking study was also conducted using the aromatase inhibitor letrozole. A block experiment was used to prove the specificity of the probe. Biodistribution studies were performed at 0.5, 1, and 2 h post injection (p.i.). Immunofluorescence was used to assess aromatase expression in MCF-7 cells. Results: [18F]BIBD-071 showed excellent in vitro stability and specific uptake in an MCF-7 xenograft tumour model. MicroPET/CT imaging at 1 and 2 h p.i. revealed excellent tumour visualisation with a favourable tumour-to-background ratio. Biodistribution data revealed high tracer uptake in the liver, small intestine, and stomach, with significant washout from the bloodstream and tumour over time. The tumour uptakes at 0.5 h, 1 h, and 2 h were 3.84 ± 0.13, 2.5 ± 0.17, and 2.54 ± 0.32, respectively. The tumour uptake significantly decreased between 0.5 h and 1 h (p < 0.0001), whereas there was no significant difference between 1 and 2 h. The tumour/background ratios at 0.5 h, 1 h, and 2 h were 1.19 ± 0.03, 1.12 ± 0.17, and 1.42 ± 0.11, respectively. Immunofluorescence confirmed robust aromatase expression in MCF-7 cells, which was correlated with [18F]BIBD-071 tumour uptake. Conclusions: [18F]BIBD-071 is a promising PET tracer for diagnosing and monitoring HR+ breast cancer, warranting further research into hormone-dependent cancers.
- 11 December 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 49 (3) , 1100-1109
Design of a deuterated TSPO tracer and its application in glioma and atherosclerotic imaging
TSPO tracer [18F]BIBD-239-d2 is designed and applied to improve imaging of glioma and atherosclerosis.
- 11 December 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 49 (3) , 1100-1109
Design of a deuterated TSPO tracer and its application in glioma and atherosclerotic imaging
TSPO tracer [18F]BIBD-239-d2 is designed and applied to improve imaging of glioma and atherosclerosis.