Mario Mösch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mario Mösch has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Gerhard Fischerauer
Fakultät für Ingenieurwissenschaften , Universität Bayreuth , 95440 Bayreuth , Germany
4 shared publications Alice Fischerauer
Universität Bayreuth, Zentrum für Energietechnik (ZET), Lehrstuhl für Mess- und Regeltechnik, Bayreuth Germany
1 shared publication- Christoph Kandlbinder-Paret
Chair of Measurement and Control Systems, Faculty of Engineering Science, University of Bayreuth, Bayreuth, Germany
1 shared publication - Daniel Hoffmann
Hahn-Schickard, Wilhelm-Schickard-Str.10, D-78052 Villingen-Schwenningen, Germany
1 shared publication Martin Siegl
Deutsches Zentrum fur Luft und Raumfahrt, Institut für Raumfahrtsysteme, Bremen Germany
1 shared publicationTobias Helling
Universität Bayreuth, Zentrum für Energietechnik (ZET), Lehrstuhl für Mess- und Regeltechnik, Bayreuth Germany
1 shared publication
Latest Publications
- Open Access
A Self-Adaptive and Self-Sufficient Energy Harvesting System
Self-adaptive vibration energy harvesters convert the kinetic energy from vibration sources into electrical energy and continuously adapt their resonance frequency to the vibration frequency. Only when the two frequencies match can the system harvest energy efficiently. The harvesting of vibration sources with a time-variant frequency therefore requires self-adaptive vibration harvesting systems without human intervention. This work presents a self-adaptive energy harvesting system that works completely self-sufficiently. Using magnetic forces, the axial load on a bending beam is changed and thus the resonance frequency is set. The system achieves a relative tuning range of 23% at a center frequency of 36.4 Hz. Within this range, the resonance frequency of the harvester can be set continuously and precisely. With a novel optimized method for frequency measurement and with customized electronics, the system only needs 22 µW to monitor the external vibration frequency and is therefore also suitable for environments with low vibration amplitudes. The system was verified on a vibrational test bench and can easily be tailored to a specific vibration source.
Open AccessA Self-Adaptive and Self-Sufficient Energy Harvesting System
Self-adaptive vibration energy harvesters convert the kinetic energy from vibration sources into electrical energy and continuously adapt their resonance frequency to the vibration frequency. Only when the two frequencies match can the system harvest energy efficiently. The harvesting of vibration sources with a time-variant frequency therefore requires self-adaptive vibration harvesting systems without human intervention. This work presents a self-adaptive energy harvesting system that works completely self-sufficiently. Using magnetic forces, the axial load on a bending beam is changed and thus the resonance frequency is set. The system achieves a relative tuning range of 23% at a center frequency of 36.4 Hz. Within this range, the resonance frequency of the harvester can be set continuously and precisely. With a novel optimized method for frequency measurement and with customized electronics, the system only needs 22 µW to monitor the external vibration frequency and is therefore also suitable for environments with low vibration amplitudes. The system was verified on a vibrational test bench and can easily be tailored to a specific vibration source.
- Open Access
- 28 November 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (12) , 826
A Comparison of Methods to Measure the Coupling Coefficient of Electromagnetic Vibration Energy Harvesters
Vibration energy harvesters transform environmental vibration energy into usable electrical energy. The transformation is only possible because of a coupling between the mechanical part of the energy harvester and the electric circuit. This paper compares several measurement methods to determine the electromagnetic coupling coefficient. These methods are applied to various implementations of an energy harvester and the results are compared with one another and with simulation data by analyzing the magnetic flux. The average deviation between the measurement methods and the simulation data in our study was 5%. This good agreement validates the methods. Based on this, we recommend determination of the coupling coefficient and the optimum load resistance for maximum power harvesting on the basis of simulations and the open circuit method, because this procedure leads to the shortest measurement times.
- 28 November 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (12) , 826
Open AccessA Comparison of Methods to Measure the Coupling Coefficient of Electromagnetic Vibration Energy Harvesters
Vibration energy harvesters transform environmental vibration energy into usable electrical energy. The transformation is only possible because of a coupling between the mechanical part of the energy harvester and the electric circuit. This paper compares several measurement methods to determine the electromagnetic coupling coefficient. These methods are applied to various implementations of an energy harvester and the results are compared with one another and with simulation data by analyzing the magnetic flux. The average deviation between the measurement methods and the simulation data in our study was 5%. This good agreement validates the methods. Based on this, we recommend determination of the coupling coefficient and the optimum load resistance for maximum power harvesting on the basis of simulations and the open circuit method, because this procedure leads to the shortest measurement times.
- Open Access
- 9 January 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (1) , 44
A Theory for Energy-Optimized Operation of Self-Adaptive Vibration Energy Harvesting Systems with Passive Frequency Adjustment
Self-adaptive vibration energy harvesting systems vary their resonance frequency automatically to better exploit changing environmental conditions. The energy required for the adjustment is taken from the energy storage of the harvester module. The energy gained by an adjustment step has to exceed the energy expended on it to justify the adjustment. A smart self-adaptive system takes this into account and operates in a manner that maximizes the energy output. This paper presents a theory for the optimal operation of a vibration energy harvester with a passive resonance-frequency adjustment mechanism (one that only requires energy for the adjustment steps proper, but not during the hold phases between the steps). Several vibration scenarios are considered to derive a general guideline. It is shown that there exist conditions under which a narrowing of the adjustment bandwidth improves the system characteristics. The theory is applied to a self-adaptive energy harvesting system based on electromagnetic transduction with narrowband resonators. It is demonstrated that the novel optimum mode of operation increases the energy output by a factor of 3.6.
- 9 January 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (1) , 44
Open AccessA Theory for Energy-Optimized Operation of Self-Adaptive Vibration Energy Harvesting Systems with Passive Frequency Adjustment
Self-adaptive vibration energy harvesting systems vary their resonance frequency automatically to better exploit changing environmental conditions. The energy required for the adjustment is taken from the energy storage of the harvester module. The energy gained by an adjustment step has to exceed the energy expended on it to justify the adjustment. A smart self-adaptive system takes this into account and operates in a manner that maximizes the energy output. This paper presents a theory for the optimal operation of a vibration energy harvester with a passive resonance-frequency adjustment mechanism (one that only requires energy for the adjustment steps proper, but not during the hold phases between the steps). Several vibration scenarios are considered to derive a general guideline. It is shown that there exist conditions under which a narrowing of the adjustment bandwidth improves the system characteristics. The theory is applied to a self-adaptive energy harvesting system based on electromagnetic transduction with narrowband resonators. It is demonstrated that the novel optimum mode of operation increases the energy output by a factor of 3.6.
- 5 January 2017
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 84 (6) , 389-400
Kapazitive Messungen in Zweiphasengemischen am Beispiel von kryogenem Stickstoff
Zusammenfassung Die Ober- und Hauptstufen von Trägerraketen werden oftmals mit kryogenen Flüssigkeiten betrieben. Im Besonderen ist es für eine Zündung des Triebwerkes in der Schwerelosigkeit wichtig, das Verhalten dieser kryogenen Flüssigkeiten zu beobachten. Zum Beispiel stellen Gasblasen, welche in die Treibstoffzuleitungen gelangen und durch Kavitation Teile des Triebwerks zerstören können, eine Gefahr für die Wiederzündung dar. Daher haben wir ein kapazitives Messsystem für Zweiphasengemische realisiert, welches ohne messbaren Energieeintrag unter tiefkalten Bedingungen arbeiten kann. Dabei sind die Elektroden so angeordnet, dass Phasenänderungen innerhalb des beobachteten Volumens erfasst werden. Die charakteristischen Kapazitätsverläufe der unterschiedlichen Elektrodenpaarungen wurden experimentell bestimmt und einerseits mit Finite-Elemente-Simulationen (Ansys) verglichen. Andererseits wurden Berechnungen zur elektrischen Flussdichte angestellt, welche die simulierten Kapazitätsverläufe mit theoretischen Aussagen ergänzen. Da die Messungen mit Rauschen überlagert sind, wurde ein gleitendes Mittelwertfilter auf die Messergebnisse angewendet. Solche experimentell ermittelten und gefilterten Ergebnisse spiegeln die aus der Auswertung von Videokameraaufnahmen abgeleiteten Phasengrenzen zwischen flüssigem und gasförmigem Stickstoff (in einem umgestülpten Behältnis, das in einen Tank voller flüssigen Stickstoffs getaucht war) mit nur geringen Abweichungen wider. Zudem ließen sich verschiedene Prozesse wie Verschiebungen einer makroskopischen Phasengrenze (Füllstandsänderungen im umgestülpten Behältnis) und im flüssigen Stickstoff aufsteigende Gasblasen anhand der gemessenen Kapazitäten unterscheiden.
- 5 January 2017
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 84 (6) , 389-400
Kapazitive Messungen in Zweiphasengemischen am Beispiel von kryogenem Stickstoff
Zusammenfassung Die Ober- und Hauptstufen von Trägerraketen werden oftmals mit kryogenen Flüssigkeiten betrieben. Im Besonderen ist es für eine Zündung des Triebwerkes in der Schwerelosigkeit wichtig, das Verhalten dieser kryogenen Flüssigkeiten zu beobachten. Zum Beispiel stellen Gasblasen, welche in die Treibstoffzuleitungen gelangen und durch Kavitation Teile des Triebwerks zerstören können, eine Gefahr für die Wiederzündung dar. Daher haben wir ein kapazitives Messsystem für Zweiphasengemische realisiert, welches ohne messbaren Energieeintrag unter tiefkalten Bedingungen arbeiten kann. Dabei sind die Elektroden so angeordnet, dass Phasenänderungen innerhalb des beobachteten Volumens erfasst werden. Die charakteristischen Kapazitätsverläufe der unterschiedlichen Elektrodenpaarungen wurden experimentell bestimmt und einerseits mit Finite-Elemente-Simulationen (Ansys) verglichen. Andererseits wurden Berechnungen zur elektrischen Flussdichte angestellt, welche die simulierten Kapazitätsverläufe mit theoretischen Aussagen ergänzen. Da die Messungen mit Rauschen überlagert sind, wurde ein gleitendes Mittelwertfilter auf die Messergebnisse angewendet. Solche experimentell ermittelten und gefilterten Ergebnisse spiegeln die aus der Auswertung von Videokameraaufnahmen abgeleiteten Phasengrenzen zwischen flüssigem und gasförmigem Stickstoff (in einem umgestülpten Behältnis, das in einen Tank voller flüssigen Stickstoffs getaucht war) mit nur geringen Abweichungen wider. Zudem ließen sich verschiedene Prozesse wie Verschiebungen einer makroskopischen Phasengrenze (Füllstandsänderungen im umgestülpten Behältnis) und im flüssigen Stickstoff aufsteigende Gasblasen anhand der gemessenen Kapazitäten unterscheiden.