BTBhola Thapa

Bhola Thapa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bhola Thapa has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Scaling Mechanical Knee Joints for Pediatric Transfemoral Prostheses: Does a Linear Geometric Factor Work?

    by Pratisthit Lal Shrestha, Bhola Thapa, S. Sujatha

    Introduction: Pediatric prosthetic knee joints must be appropriately scaled from adult designs to ensure proper gait biomechanics. However, direct dimensional scaling without considering the biomechanical implications may lead to functional discrepancies. This study aimed to evaluate whether using a linear scaling factor can effectively adapt a knee for pediatric use. The study assessed whether such an approach yields a viable pediatric prosthetic knee joint by applying a fixed scaling factor and analyzing the resultant knee geometry. Methods: The linear scaling factor was determined based on the pylon tube diameter, a key constraint in compact pediatric knee design. Given a pediatric pylon diameter of 22 mm, the length of the tibial link was set to 22 mm, yielding a scaling factor of 0.6875 when compared to the adult-sized knee. This scaling factor was used to determine the dimensions of the pediatric four-bar (scaled) knee joint. Static geometric analysis was conducted using GeoGebra® to model the lower-body segment lengths. The knee joint’s performance was evaluated based on stance and swing phase parameters. These metrics were compared between the scaled knee and a commercial pediatric knee. Results: The geometric analysis revealed that while using the linear scaling factor maintained proportional relationships, certain biomechanical parameters deviated from the expected pediatric norms. The scaled knee achieved a toe clearance of 13.5 mm compared to 19.7 mm in the commercial design and demonstrated a swing-phase heel clearance of 11.6 mm versus 13.3 mm, maintaining negative x/y ratios at heel contact and showing significant stability in push-off moments, while the stance flexion angle remained within an acceptable range. The heel contact and push-off ratios (x/y) were found to be comparable, with the scaled model achieving values of −1.21 and −0.59, respectively. The stance flexion angle measured 10.6°, closely aligning with the commercial reference. Conclusions: Using a linear scaling factor provides a straightforward method for adapting adult prosthetic knee designs to pediatric use. However, deviations in key biomechanical parameters indicate that further experimental study may be required to validate the applicability of the scaled knee joint for pediatric users. Future work should explore dynamic simulations and experimental validations to refine the design further and ensure optimal gait performance.


  • Open Access

    Experimental investigation of vibrational signal in a fault induced Francis runner

    by Prajwal Sapkota, Subarna Paudel, Ravi Poudel, Sailesh Chitrakar, Hari Prasad Neopane, Bhola Thapa

    Hydro turbines are prone to failure and the detection of fault in turbine is essential to ensure the reliability of power plant. This study investigates vibrational signals in a fault-induced Francis turbine using an experimental test setup to identify the trends that could be helpful in diagnosis of turbine faults. By analyzing the vibrational signal, the study aims to correlate the turbine's dynamic behavior. Faults in the turbine have been introduced by adding masses to the blades, and the experimental tests are conducted under two different conditions: dry and wet testing conditions for both normal and faulty turbine blades. The turbine's operating condition is determined with the help of pressure, flow, and RPM sensors. The turbine's speed is varied using a variable frequency drive. For the acquisition of vibration signals, the NI-LabVIEW system is employed along with a uniaxial vibration sensor located at the turbine bearing. The obtained vibration data are analyzed using the Fast Fourier Transform (FFT) algorithm and wavelet transform algorithm to identify frequency-domain characteristics. While studying and comparing the fundamental frequency of the turbine shaft, it is found that turbine faults can either increase or decrease the amplitude of the resonant peak frequency of the system, but the amplitude at other frequencies remains almost unaffected.


  • Open Access

    Experimental Erosion Flow Pattern Study of Pelton Runner Buckets Using a Non-Recirculating Test Rig

    by Baig Mirza Umar, Zhengwei Wang, Sailesh Chitrakar, Bhola Thapa, Xingxing Huang, Ravi Poudel, Aaditya Karna

    Sediment erosion of hydraulic turbines is a significant challenge in hydropower plants in mountainous regions like the European Alps, the Andes, and the Himalayan region. The erosive wear of Pelton runner buckets is influenced by a variety of factors, including the size, hardness, and concentration of silt particles; the velocity of the flow and impingement angle of the jet; the properties of the base material; and the operating hours of the turbine. This research aims to identify the locations most susceptible to erosion and to elucidate the mechanisms of erosion propagation in two distinct designs of Pelton runner buckets. The Pelton runner buckets were subjected to static condition tests with particle sizes of 500 microns and a concentration of 14,000 mg/L. The buckets were coated with four layers of paint, sequentially applied in red, yellow, green, and blue. The two Pelton buckets, D1 and D2, were evaluated for their erosion resistance properties. D2 demonstrated superior erosion resistance, attributed to its geometrical features and material composition, lower erosion rates, less material loss, and improved surface integrity compared with D1. This difference is primarily attributed to factors such as the splitter’s thickness, the jet’s impact angle, the velocity at which particles strike, and the concentration of sand. D2 exhibits a great performance in terms of erosion resistance among the two designs. This study reveals that the angle of jet impingement influences erosion progression and material loss, which is important to consider during a Pelton turbine’s design and operating conditions.


  • Equations, Codes, and Case Study for Three Phases

    by Zhiwei Guo, Sailesh Chitrakar, Zhongdong Qian, Bhola Thapa

  • Calculation of the Main Dimensions of Francis Runner

    by Zhiwei Guo, Sailesh Chitrakar, Zhongdong Qian, Bhola Thapa

  • Design of the Distributors

    by Zhiwei Guo, Sailesh Chitrakar, Zhongdong Qian, Bhola Thapa

  • Erosion Calculation in Francis Turbine

    by Zhiwei Guo, Sailesh Chitrakar, Zhongdong Qian, Bhola Thapa

  • Equations, Codes, and Case Study for Single Phase

    by Zhiwei Guo, Sailesh Chitrakar, Zhongdong Qian, Bhola Thapa

  • Shape of the Runner Blades

    by Zhiwei Guo, Sailesh Chitrakar, Zhongdong Qian, Bhola Thapa

  • Introduction

    by Zhiwei Guo, Sailesh Chitrakar, Zhongdong Qian, Bhola Thapa