Azzam S. Salman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Azzam S. Salman has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Jamil A. Khan
7 shared publicationsSaad K. Oudah
6 shared publicationsAmitav Tikadar
5 shared publicationsTitan C. Paul
5 shared publicationsNabeel M. Abdulrazzaq
3 shared publications- Noble Anumbe
Department of Mechanical Engineering, University of South Carolina, Columbia, SC 29201, USA
2 shared publications
Latest Publications
- 14 July 2019
- Published by ASME International
The Effect of Chamber Pressure on the Thermal Performance of New Refrigerant R513a During Spray Cooling
In this paper, the performance of a new low-GWP refrigerant R513a was experimentally investigated, during spray cooling. A spray cooling system was designed to work as a sub-system within a closed-loop refrigeration system. The influence of chamber pressure on heat flux and heat transfer coefficient were experimentally investigated. A smooth plain copper surface heated by a cartridge heater was cooled by the refrigerant (R513a) while flowing through a nozzle in the spray chamber. The results showed that chamber pressure has a significant impact on the overall thermal performance of the spray cooling operation. It was also determined that higher chamber pressures resulted in higher thermal performance. The highest chamber pressure attained in this study was 0.6 MPa. Furthermore, the surface temperature of the heated surface increased due to the increase of the saturation temperature of the liquid over the surface.
- 14 July 2019
- Published by ASME International
The Effect of Chamber Pressure on the Thermal Performance of New Refrigerant R513a During Spray Cooling
In this paper, the performance of a new low-GWP refrigerant R513a was experimentally investigated, during spray cooling. A spray cooling system was designed to work as a sub-system within a closed-loop refrigeration system. The influence of chamber pressure on heat flux and heat transfer coefficient were experimentally investigated. A smooth plain copper surface heated by a cartridge heater was cooled by the refrigerant (R513a) while flowing through a nozzle in the spray chamber. The results showed that chamber pressure has a significant impact on the overall thermal performance of the spray cooling operation. It was also determined that higher chamber pressures resulted in higher thermal performance. The highest chamber pressure attained in this study was 0.6 MPa. Furthermore, the surface temperature of the heated surface increased due to the increase of the saturation temperature of the liquid over the surface.
- 1 May 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 153, 15-28
Parametric study on thermal and hydraulic characteristics of inter-connected parallel and counter flow mini-channel heat sink
- 1 May 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 153, 15-28
Parametric study on thermal and hydraulic characteristics of inter-connected parallel and counter flow mini-channel heat sink
- 9 November 2018
- Published by ASME International
Effect of Inter-Connector on Thermo-Hydraulic Characteristics of Parallel and Counter Flow Mini-Channel Heat Sink
A numerical investigation of three-dimensional conjugate heat transfer was performed to quantify the thermal and hydraulic performance of an inter-connected parallel and counter flow mini-channel heat sink under laminar flow condition and within the single-phase regime. The aspect ratio (height/width) and the hydraulic diameter of the mini-channel were 0.33 and 750μm respectively. Three different widths of the inter-connector were selected to analyze the effect of cross flow for Reynolds number ranging from 150 to 1044, at a constant heat flux (20 W/cm2). To understand the fluid flow and heat transfer mechanism inside the inter-connector and their effects on overall thermal performance of the heat sink, Nusselt number (Nu), friction factor, pumping power, and overall thermal resistance were analyzed. Results show that the inter-connector has significantly higher effect on counter flow mini-channel heat sink than parallel flow mini-channel heat sink.
- 9 November 2018
- Published by ASME International
Effect of Inter-Connector on Thermo-Hydraulic Characteristics of Parallel and Counter Flow Mini-Channel Heat Sink
A numerical investigation of three-dimensional conjugate heat transfer was performed to quantify the thermal and hydraulic performance of an inter-connected parallel and counter flow mini-channel heat sink under laminar flow condition and within the single-phase regime. The aspect ratio (height/width) and the hydraulic diameter of the mini-channel were 0.33 and 750μm respectively. Three different widths of the inter-connector were selected to analyze the effect of cross flow for Reynolds number ranging from 150 to 1044, at a constant heat flux (20 W/cm2). To understand the fluid flow and heat transfer mechanism inside the inter-connector and their effects on overall thermal performance of the heat sink, Nusselt number (Nu), friction factor, pumping power, and overall thermal resistance were analyzed. Results show that the inter-connector has significantly higher effect on counter flow mini-channel heat sink than parallel flow mini-channel heat sink.
- 1 November 2018
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 126, 493-507
Numerical investigation of heat transfer and pressure drop in nuclear fuel rod with three-dimensional surface roughness
- 1 November 2018
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 126, 493-507
Numerical investigation of heat transfer and pressure drop in nuclear fuel rod with three-dimensional surface roughness
- 3 November 2017
- Published by ASME International
The Effects of Spraying Parameters on Spray Cooling Heat Transfer Performance in the Non-Boiling Regime
Experiments were conducted in a closed loop spray cooling system working with deionized water as a working fluid. This study was performed to investigate the effect of the spraying parameters, such as Sauter mean diameter (SMD), the droplet velocity, and the residual velocity on the spray cooling heat transfer in the non-boiling region. Thermal effects on plain and modified surfaces with circular grooves were examined under different operating conditions. The inlet pressure of the working fluid was varied from 78.6 kPa to 183.515kPa, and the inlet temperature was kept between 21–22 °C. The distance between the nozzle and the target surface 10 mm. The results showed that increasing the coolant inlet pressure increases the droplet velocity and the number of droplets produced while decreasing the droplet size. As a consequence of these changes, increasing inlet pressure improved the heat transfer characteristics of both surfaces.
- 3 November 2017
- Published by ASME International
The Effects of Spraying Parameters on Spray Cooling Heat Transfer Performance in the Non-Boiling Regime
Experiments were conducted in a closed loop spray cooling system working with deionized water as a working fluid. This study was performed to investigate the effect of the spraying parameters, such as Sauter mean diameter (SMD), the droplet velocity, and the residual velocity on the spray cooling heat transfer in the non-boiling region. Thermal effects on plain and modified surfaces with circular grooves were examined under different operating conditions. The inlet pressure of the working fluid was varied from 78.6 kPa to 183.515kPa, and the inlet temperature was kept between 21–22 °C. The distance between the nozzle and the target surface 10 mm. The results showed that increasing the coolant inlet pressure increases the droplet velocity and the number of droplets produced while decreasing the droplet size. As a consequence of these changes, increasing inlet pressure improved the heat transfer characteristics of both surfaces.
- 9 July 2017
- Published by ASME International
Experimental Investigation of Spray Cooling Heat Transfer on Circular Grooved Surface
An experimental study was conducted in a closed loop spray cooling system working with deionized water as a cooling medium, to investigate the effects of surface modification on the spray cooling heat transfer enhancement in the single-phase region. Plain copper surface with diameter 1.5 cm and an enhanced surface with circular grooves were tested under different operating conditions. The volumetric flow rate of the coolant ranged from 115 mL/min to 177 mL/min., and the water inlet temperature was kept between 21–23 °C. Also, the distances between the nozzle and the target surface were varied at 8, 10, and 12 mm respectively. The results show that the distance between the nozzle and the target surface did not have a significant effect on the heat transfer performance for the low flow rates, while it has a slight effect on high flow rates for both surfaces. Also, increasing the liquid volumetric flow rate increases the amount of heat removed, and the heat transfer coefficient for both surfaces. Moreover, the maximum enhancement ratios achieved were 23.4% and 31% with volumetric flow rates of 153 mL/min, and 177 mL/min respectively.
- 9 July 2017
- Published by ASME International
Experimental Investigation of Spray Cooling Heat Transfer on Circular Grooved Surface
An experimental study was conducted in a closed loop spray cooling system working with deionized water as a cooling medium, to investigate the effects of surface modification on the spray cooling heat transfer enhancement in the single-phase region. Plain copper surface with diameter 1.5 cm and an enhanced surface with circular grooves were tested under different operating conditions. The volumetric flow rate of the coolant ranged from 115 mL/min to 177 mL/min., and the water inlet temperature was kept between 21–23 °C. Also, the distances between the nozzle and the target surface were varied at 8, 10, and 12 mm respectively. The results show that the distance between the nozzle and the target surface did not have a significant effect on the heat transfer performance for the low flow rates, while it has a slight effect on high flow rates for both surfaces. Also, increasing the liquid volumetric flow rate increases the amount of heat removed, and the heat transfer coefficient for both surfaces. Moreover, the maximum enhancement ratios achieved were 23.4% and 31% with volumetric flow rates of 153 mL/min, and 177 mL/min respectively.