AAAnne Marie Augustin

Anne Marie Augustin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anne Marie Augustin has a total of 65 co-authors. Here are the top co-authors by number of shared publications:

  • Ralph Kickuth

    Institute of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany

    11 shared publications
  • Thorsten Alexander Bley

    Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany

    6 shared publications
  • Ralph Kickuth

    Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany

    5 shared publications
  • Annette Thurner

    Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany

    4 shared publications
  • Thorsten Alexander Bley

    Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany

    4 shared publications
  • Viktor Hartung

    Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany

    3 shared publications

Latest Publications

  • Open Access

    Photon-Counting Detector CT Angiography Versus Digital Subtraction Angiography in Patients with Peripheral Arterial Disease

    by Anne Marie Augustin, Viktor Hartung, Jan-Peter Grunz, Jan-Lucca Hennes, Henner Huflage, Thorsten Alexander Bley, Bernhard Petritsch, Philipp Gruschwitz


  • Management of isolated dissection of the superior mesenteric artery

    by Jonas Knarr, Anne Marie Augustin, Viktor Hartung, Katica Krajinovic, Ralph Kickuth

    Purpose Isolated dissection of the superior mesenteric artery (IDSMA) is an increasingly frequently diagnosed pathology without a predisposing factor. Different therapeutic options including conservative, endovascular, and open surgical treatment are presented in our single-center study. The follow-up is a special task of different specialties. Methods and Patients A retrospective analysis of six patients with IDSMA was conducted. Patient demographics, clinical presentation, diagnostic management, and therapeutic treatment were assessed. Furthermore, clinical outcome as well as further changes during follow-up were evaluated. Results The majority of the patients were symptomatic with abdominal pain. Of the symptomatic patients, one was managed conservatively, one was treated surgically by patch plasty, and two patients were treated using an endovascular approach. The two asymptomatic patients were each managed conservatively. Conservative therapy was the treatment of choice, especially in asymptomatic and uncomplicated cases with non-persistent symptoms. This was confirmed in our literature review. Computed tomography angiography is the gold standard for follow-up after the acute event or diagnosis. None of our patients needed further treatment after the acute event/detection of IDSMA during the follow-up period with a mean of 68 months. One patient showed significant changes in the diameter of the superior mesenteric artery. Conclusion The appropriate diagnosis, treatment, and follow-up of IDSMA must be tailored to the needs of the individual patient and require multidisciplinary decision making. Key Points: Hintergrund Die isolierte Dissektion der A. mesenterica superior (IDSMA) ist eine immer häufiger diagnostizierte Pathologie ohne prädisponierenden Faktor. In unserer Single-Center-Studie werden verschiedene Therapieoptionen vorgestellt, darunter die konservative, endovaskuläre und offen-chirurgische Behandlung. Die Nachsorge ist eine besondere Aufgabe der verschiedenen Fachrichtungen. Methoden und Patienten Es wurde eine retrospektive Analyse von sechs Patienten mit IDSMA durchgeführt. Bewertet wurden demografische Patientendaten, die klinischen Befunde, das diagnostische Management und die anschließende therapeutische Behandlung. Darüber hinaus wurden die klinische Symptomatik bezüglich des Nachlassens des Schmerzes und weitere Veränderungen während der Nachbeobachtung evaluiert. Ergebnisse Die Mehrzahl der Patienten war symptomatisch und litt unter Bauschmerzen. Von den symptomatischen Patienten wurde ein Patient konservativ behandelt, ein Patient wurde chirurgisch mit einer Patchplastik behandelt und zwei Patienten erhielten eine endovaskuläre Therapie. Die beiden asymptomatischen Patienten wurden jeweils konservativ behandelt. Die konservative Therapie war die Behandlung der Wahl, insbesondere bei asymptomatischen und unkomplizierten Fällen mit nicht persistierenden Symptomen. Für die Nachsorge ist die Computertomografie mit Angiografie der Goldstandard. Keiner unserer Patienten benötigte nach dem akuten Ereignis bzw. dem Nachweis einer asymptomatischen IDSMA während der Nachbeobachtungszeit von durchschnittlich 68 Monaten eine weitere Behandlung. Ein Patient wies signifikante Veränderungen des Durchmessers der A. mesenterica superior auf. Schlussfolgerung Die angemessene Diagnose, Behandlung und Nachsorge von IDSMA muss auf die Bedürfnisse des einzelnen Patienten zugeschnitten sein und erfordert eine multidisziplinäre Entscheidungsfindung. Kernaussagen: Zitierweise Received: 11 May 2023 Accepted: 21 November 2023 Article published online: 04 January 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Open Access

    An Intra-Individual Comparison of Low-keV Photon-Counting CT versus Energy-Integrating-Detector CT Angiography of the Aorta

    by Jan-Lucca Hennes, Henner Huflage, Jan-Peter Grunz, Viktor Hartung, Anne Marie Augustin, Theresa Sophie Patzer, Pauline Pannenbecker, Bernhard Petritsch, Thorsten Alexander Bley, Philipp Gruschwitz

    This retrospective study aims to provide an intra-individual comparison of aortic CT angiographies (CTAs) using first-generation photon-counting-detector CT (PCD-CT) and third-generation energy-integrating-detector CT (EID-CT). High-pitch CTAs were performed with both scanners and equal contrast-agent protocols. EID-CT employed automatic tube voltage selection (90/100 kVp) with reference tube current of 434/350 mAs, whereas multi-energy PCD-CT scans were generated with fixed tube voltage (120 kVp), image quality level of 64, and reconstructed as 55 keV monoenergetic images. For image quality assessment, contrast-to-noise ratios (CNRs) were calculated, and subjective evaluation (overall quality, luminal contrast, vessel sharpness, blooming, and beam hardening) was performed independently by three radiologists. Fifty-seven patients (12 women, 45 men) were included with a median interval between examinations of 12.7 months (interquartile range 11.1 months). Using manufacturer-recommended scan protocols resulted in a substantially lower radiation dose in PCD-CT (size-specific dose estimate: 4.88 ± 0.48 versus 6.28 ± 0.50 mGy, p < 0.001), while CNR was approximately 50% higher (41.11 ± 8.68 versus 27.05 ± 6.73, p < 0.001). Overall image quality and luminal contrast were deemed superior in PCD-CT (p < 0.001). Notably, EID-CT allowed for comparable vessel sharpness (p = 0.439) and less pronounced blooming and beam hardening (p < 0.001). Inter-rater agreement was good to excellent (0.58–0.87). Concluding, aortic PCD-CTAs facilitate increased image quality with significantly lower radiation dose compared to EID-CTAs.


  • Photon-Counting Detector CT for Femoral Stent Imaging in an Extracorporeally Perfused Human Cadaveric Model

    by Viktor Hartung, Philipp Gruschwitz, Henner Huflage, Anne Marie Augustin, Florian Kleefeldt, Dominik Peter, Sven Lichthardt, Süleyman Ergün, Thorsten Alexander Bley, Jan-Peter Grunz, et al.

    Background and Aims: This study aims to compare the performance of first-generation dual-source photon-counting detector computed tomography (PCD-CT) to third-generation dual-source energy-integrating detector (EID-CT) regarding stent imaging in the femoral arterial runoff. Methods: Continuous extracorporeal perfusion was established in 1 human cadaver using an inguinal and infragenicular access and peristaltic pump. Seven peripheral stents were implanted into both superior femoral arteries by means of percutaneous angioplasty. Radiation dose-equivalent CT angiographies (high-/medium-/low-dose: 10/5/3 mGy) with constant tube voltage of 120 kVp, matching iterative reconstruction algorithm levels, and convolution kernels were used both with PCD-CT and EID-CT. In-stent lumen visibility, luminal and in-stent attenuation as well as contrast-to-noise ratio (CNR) were assessed via region of interest and diameter measurements. Results were compared using analyses of variance and regression analyses. Results: Maximum in-stent lumen visibility achieved with PCD-CT was 94.48% ± 2.62%. The PCD-CT protocol with the lowest lumen visibility (BV40: 78.93% ± 4.67%) performed equal to the EID-CT protocol with the best lumen visibility (BV59: 79.49% ± 2.64%, P > 0.999). Photon-counting detector CT yielded superior CNR compared with EID-CT regardless of kernel and dose level (P < 0.001). Maximum CNR was 48.8 ± 17.4 in PCD-CT versus 31.28 ± 5.7 in EID-CT (both BV40, high-dose). The theoretical dose reduction potential of PCD-CT over EID-CT was established at 88% (BV40), 83% (BV48/49), and 73% (BV59/60), respectively. In-stent attenuation was not significantly different from luminal attenuation outside stents in any protocol. Conclusions: With superior lumen visibility and CNR, PCD-CT allowed for noticeable dose reduction over EID-CT while maintaining image quality in a continuously perfused human cadaveric model.


  • Bilateral inferior petrosal sinus sampling: Procedural data from a German single-center study

    by Anne Marie Augustin, Mario Detomas, Viktor Hartung, Annette Thurner, Viola Tröger, Timo Deutschbein, Ralph Kickuth

    Purpose To assess radiation exposure and diagnostic performance of bilateral inferior petrosal sinus sampling for the distinction of pituitary and ectopic adrenocorticotropin-dependent Cushingʼs syndrome. Materials and Methods Procedural data of bilateral inferior petrosal sinus procedures were retrospectively evaluated. The analysis included the patients’ clinical and demographic data, procedural radiation exposure, and complication rates, sampling results, clinical course of the patients, and calculation of diagnostic performance data. Results The cases of 46 patients diagnosed with adrenocorticotropin-dependent Cushingʼs syndrome were evaluated. Bilateral inferior petrosal sinus sampling was successfully performed in 97.8 % of the cases. The overall median procedure-related fluoroscopy time was 7.8 min. (range 3.2–36.2 min.), and the median procedural dose area product was 11.9 Gy*cm2 (range 2.1–73.7 Gy*cm2). Radiation doses due to digital subtraction angiography series for visualization of the inferior petrosal sinus were 3.6 Gy*cm2 (range 1.0–18.1 Gy*cm2). Radiation doses due to fluoroscopy had a higher impact on the overall radiation exposure and were significantly influenced by the patients’ habitus. The sensitivity, specificity, and positive and negative predictive values were 84 %, 100 %, 100 %, and 72 % before stimulation with corticotropin-releasing hormone, and 97 %, 100 %, 100 %, and 93 % after stimulation. Concordance between magnetic resonance imaging studies and bilateral inferior petrosal sinus sampling results was only found in 35.6 % of the cases. The periprocedural complication rate was 2.2 %, with one patient experiencing vasovagal syncope during catheterization. Conclusion Bilateral inferior petrosal sinus sampling is a safe procedure with high technical success rates und excellent diagnostic performance. The procedure-related radiation exposure shows large variations and depends on the complexity of cannulation as well as the patients’ habitus. Fluoroscopy accounted for the largest proportion of radiation exposure. Acquisition of digital subtraction angiography series for the verification of correct catheter placement appears justified. Key Points: Citation Format Ziel Bestimmung der Strahlenbelastung und diagnostischen Leistungsfähigkeit der Sinus-petrosus-Blutentnahme bei der Differenzierung von hypophysärem und ektopem Adrenocorticotropin-abhängigem Cushing-Syndrom. Material und Methoden Prozedurbezogene unizentrische Daten der Sinus-petrosus-Blutentnahme wurden retrospektiv ausgewertet. Anhand klinischer und demografischer sowie prozedurbezogener Daten wurde neben der intraprozeduralen Strahlenbelastung die diagnostische Leistungsfähigkeit der Sinus-petrosus-Blutentnahme analysiert. Ergebnisse Die Auswertung beinhaltete die Daten von 46 Patienten mit der Diagnose eines Adrenocorticotropin-abhängigen Cushing-Syndroms. Die bilaterale Blutentnahme gelang im ersten Versuch in 97,8 % der Fälle. Die mediane prozedurbezogene Durchleuchtungszeit belief sich auf 7,8 min (3,2–36,2 min), das Dosisflächenprodukt auf 11,9 Gy*cm2 (2,1–73,7 Gy*cm2). Dabei entfielen im Median 3,6 Gy*cm2 (1,0–18,1 Gy*cm2) auf die Akquisition von digitalen Subtraktionsangiografie-Serien. Die Strahlenbelastung durch Einsatz der Durchleuchtung hatte einen höheren Einfluss auf die Gesamtdosis und wurde signifikant durch den Habitus der Patienten beeinflusst. Sensitivität, Spezifität, positiver und negativer Vorhersagewert beliefen sich auf 84 %, 100 %, 100 %, und 72 % vor Corticotropin-Releasing-Hormon-Stimulation und auf 97 %, 100 %, 100 %, und 93 % danach. Eine Übereinstimmung der Ergebnisse der hypophysären Magnetresonanztomografie und der Sinus-petrosus-Blutentnahme-Ergebnisse lag in nur 35,6 % der Fälle vor. Die prozedurbezogene Komplikationsrate betrug 2,2 %, wobei ein Patient während der Katheterisierung eine vasovagale Synkope erlitt. Schlussfolgerung Die Sinus-petrosus-Blutentnahme ist ein sicheres Verfahren mit hohen technischen Erfolgsraten und diagnostischer Leistungsfähigkeit. Die prozedurbezogene Strahlenbelastung zeigt eine breite Variabilität und wird durch die Komplexität der Sondierung sowie den Patientenhabitus beeinflusst. Die Akquisition von digitalen Subtraktionsangiografie-Serien zur Verifikation der korrekten Katheterplatzierung vor Blutentnahme kann basierend auf den vorliegenden Daten als gerechtfertigt bewertet werden. Kernaussagen: Received: 14 December 2022 Accepted: 23 April 2023 Article published online: 24 May 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Open Access

    Malignant obstruction of the inferior vena cava: clinical experience with the self-expanding Sinus-XL stent system

    by Anne Marie Augustin, Leonie Johanna Lucius, Annette Thurner, Ralph Kickuth

    Purpose: To evaluate the technical and clinical outcome of Sinus-XL stent placement in patients with malignant obstruction syndrome of the inferior vena cava.Methods: Between October 2010 and January 2021, 21 patients with different malignant primary disease causing inferior vena cava obstruction were treated with Sinus-XL stent implantation. Procedural data, technical and clinical outcome parameters were retrospectively analyzed.Results: Technical success was 100%. Analysis of available manometry data revealed a significant reduction of the mean translesional pressure gradient following the procedure (p = 0.008). Reintervention rate was 4.8% (1/21). The available follow-up imaging studies showed primary and primary-assisted stent patency rates of 93% (13/14) and 100% (14/14), respectively. Major complications did not occur. The clinical success regarding lower extremity edema was 82.4% (14/17) for the first and 85.7% (18/21) for the last follow-up. Longer lengths of IVC obstruction were associated with reduced clinical improvement after the procedure (p = 0.025). Improvement of intraprocedural manometry results and lower extremity edema revealed only minor correlation. Ascites and anasarca were not significantly positively affected by the procedure.Conclusion: Sinus-XL stent placement in patients with malignant inferior vena cava obstruction showed high technical success and low complication rates. Regarding the clinical outcome, significant symptom improvement could be achieved in lower extremity edema, whereas ascites and anasarca lacked satisfying symptom relief. Based on our results, this procedure should be considered as a suitable therapy in a palliative care setting for patients with advanced malignant disease.


  • Open Access

    Percutaneous implantation of peripherally inserted totally implantable venous access systems in the forearm in adolescent patients

    by Anne Marie Augustin, Olivia Kertels, Verena Wiegering, Annette Thurner, Ralph Kickuth

    Background: Children with different underlying malignant diseases require long-term central venous access. As for port systems in a pectoral position, peripherally implanted port systems in the forearm revealed high levels of technical and clinical success in adult cohorts. Objective: To investigate the technical and clinical outcomes of percutaneous central venous port implantation in the forearm in adolescents. Materials and methods: Between April 2010 and August 2020, 32 children ages 9 to 17 years with underlying malignancy received 35 totally implantable venous access ports (TIVAPs) in the forearm. All venous port systems were peripherally inserted under ultrasound guidance. Correct catheter placement was controlled by fluoroscopy. As primary endpoints, the technical success, rate of complications and catheter maintenance were analyzed. Secondary endpoints were the side of implantation, vein of catheter access, laboratory results on the day of the procedure, procedural radiation exposure, amount of contrast agent and reasons for port device removal. Results: Percutaneous TIVAP placement under sonographic guidance was technically successful in 34 of 35 procedures (97.1%). Procedure-related complications did not occur. During the follow-up, 13,684 catheter days were analyzed, revealing 11 complications (0.8 per 1,000 catheter-duration days), Of these 11 complications, 7 were major and 10 occurred late. In seven cases, the port device had to be removed; removal-related complications did not occur. Conclusion: Peripheral TIVAP placement in the forearms of children is a feasible, effective and safe technique with good midterm outcome. As results are comparable with standard access routes, this technique may be offered as an alternative when intermittent venous access is required.


  • Open Access

    Color-coded summation images for the evaluation of blood flow in endovascular aortic dissection fenestration

    by Anne Marie Augustin, Franziska Wolfschmidt, Thilo Elsässer, Alexander Sauer, Alexander Dierks, Thorsten Alexander Bley, Ralph Kickuth

    To analyze the benefit of color-coded summation images in the assessment of target lumen perfusion in patients with aortic dissection and malperfusion syndrome before and after fluoroscopy-guided aortic fenestration. Between December 2011 and April 2020 25 patients with Stanford type A (n = 13) or type B dissection (n = 12) and malperfusion syndromes were treated with fluoroscopy-guided fenestration of the dissection flap using a re-entry catheter. The procedure was technically successful in 100% of the cases and included additional iliofemoral stent implantation in four patients. Intraprocedural systolic blood pressure measurements for gradient evaluation were performed in 19 cases. Post-processed color-coded DSA images were obtained from all DSA series before and following fenestration. Differences in time to peak (dTTP) values in the compromised aortic lumen and transluminal systolic blood pressure gradients were analyzed retrospectively. Correlation analysis between dTTP and changes in blood pressure gradients was performed. Mean TTP prior to dissection flap fenestration was 6.85 ± 1.35 s. After fenestration, mean TTP decreased significantly to 4.96 ± 0.94 s (p < 0.001). Available systolic blood pressure gradients between the true and the false lumen were reduced by a median of 4.0 mmHg following fenestration (p = 0.031), with significant reductions in Stanford type B dissections (p = 0.013) and minor reductions in type A dissections (p = 0.530). A moderate correlation with no statistical significance was found between dTTP and the difference in systolic blood pressure (r = 0.226; p = 0.351). Hemodynamic parameters obtained from color-coded DSA confirmed a significant reduction of TTP values in the aortic target lumen in terms of an improved perfusion in the compromised aortic region. Color-coded DSA might thus be a suitable complementary tool in the assessment of complex vascular patterns prevailing in aortic dissections, especially when blood pressure measurements are not conclusive or feasible.