Lori A. Michener
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lori A. Michener has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Matthew K. Walsworth
Department of Radiology, UCLA Medical Center, Los Angeles, California
3 shared publicationsAlison R. Snyder
2 shared publicationsKevin P. Murphy
‡Uniformed Services University of the Health Sciences, Bethesda, MD, and Heekin Orthopaedic Specialists, Jacksonville, FL
2 shared publicationsPhilip W. McClure
2 shared publicationsWilliam C. Doukas
†Department of Orthopaedics and Rehabilitation, Walter Reed Army Medical Center, Washington, DC
2 shared publicationsAlison R. Snyder Valier
1 shared publication
Latest Publications
- 1 November 2013
- Published by Wolters Kluwer Health in Clinical Journal of Sport Medicine
- Vol. 23 (6) , 444-449
Neovascularization Prevalence in the Supraspinatus of Patients With Rotator Cuff Tendinopathy
Objective: A high prevalence of neovascularity in lower extremity tendinopathies has been reported. Neovascularity in those with rotator cuff tendinopathy exclusively has not been examined. The objective was to determine the prevalence of neovascularization in patients with rotator cuff tendinopathy compared with asymptomatic controls. Design: Single-blind cross-sectional study. Setting: Research laboratory. Participants: Participants (n = 40; age = 44.9 years, 23-62 years; 20 females) with rotator cuff tendinopathy (n = 20) but without full-thickness rotator cuff tears, and asymptomatic controls that were age, gender, and hand dominance matched (n = 20) to the patients. Interventions: The participants laying in supine had their shoulder positioned in internal rotation and extension. Ultrasound images were collected of the supraspinatus tendon and subacromial bursae in the transverse and longitudinal planes using a linear transducer in color Doppler mode. Main Outcome Measures: Images were assessed for neovascularization by 2 trained raters who were blinded to group (rotator cuff tendinopathy or asymptomatic group). Results: No statistically significant difference in neovascularization was identified between participants with and without rotator cuff tendinopathy (χ2 = 0.13, df = 1, P = 0.72). Neovascularization was identified in 6 of 20 patients with rotator cuff tendinopathy (30%) and 5 of 20 asymptomatic control participants (25%). Conclusions: The authors found no differences in neovascularization rate in patients with rotator cuff tendinopathy (30%) and asymptomatic controls (25%). The study indicates that neovascularization is not related to presence of symptomatic tendinopathy in those with rotator cuff tendinopathy. Neovascularization may not be a relevant sonographic finding to aid the clinical assessment of those with rotator cuff tendinopathy.
- 1 November 2013
- Published by Wolters Kluwer Health in Clinical Journal of Sport Medicine
- Vol. 23 (6) , 444-449
Neovascularization Prevalence in the Supraspinatus of Patients With Rotator Cuff Tendinopathy
Objective: A high prevalence of neovascularity in lower extremity tendinopathies has been reported. Neovascularity in those with rotator cuff tendinopathy exclusively has not been examined. The objective was to determine the prevalence of neovascularization in patients with rotator cuff tendinopathy compared with asymptomatic controls. Design: Single-blind cross-sectional study. Setting: Research laboratory. Participants: Participants (n = 40; age = 44.9 years, 23-62 years; 20 females) with rotator cuff tendinopathy (n = 20) but without full-thickness rotator cuff tears, and asymptomatic controls that were age, gender, and hand dominance matched (n = 20) to the patients. Interventions: The participants laying in supine had their shoulder positioned in internal rotation and extension. Ultrasound images were collected of the supraspinatus tendon and subacromial bursae in the transverse and longitudinal planes using a linear transducer in color Doppler mode. Main Outcome Measures: Images were assessed for neovascularization by 2 trained raters who were blinded to group (rotator cuff tendinopathy or asymptomatic group). Results: No statistically significant difference in neovascularization was identified between participants with and without rotator cuff tendinopathy (χ2 = 0.13, df = 1, P = 0.72). Neovascularization was identified in 6 of 20 patients with rotator cuff tendinopathy (30%) and 5 of 20 asymptomatic control participants (25%). Conclusions: The authors found no differences in neovascularization rate in patients with rotator cuff tendinopathy (30%) and asymptomatic controls (25%). The study indicates that neovascularization is not related to presence of symptomatic tendinopathy in those with rotator cuff tendinopathy. Neovascularization may not be a relevant sonographic finding to aid the clinical assessment of those with rotator cuff tendinopathy.
- 5 June 2013
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (2) , 363-369
Supraspinatus tendon and subacromial space parameters measured on ultrasonographic imaging in subacromial impingement syndrome
Purpose: To characterize the supraspinatus tendon thickness, subacromial space, and the relationship between tendon thickness and subacromial space to further elucidate the mechanisms of subacromial impingement syndrome.Methods: In a single‐blind cross‐sectional study, subjects were recruited with subacromial impingement syndrome (n = 20) and asymptomatic controls (n = 20) matched for age, gender, and hand dominance. Ultrasound images were collected using a 4–12‐MHz linear transducer in B‐mode of the supraspinatus tendon in the transverse (short axis) and the anterior aspect of the subacromial space outlet. Using image callipers, measurements of tendon thickness were taken at 3 points along the tendon and averaged for a single thickness measure. The subacromial space outlet was measured via the acromiohumeral distance (AHD) defined by the inferior acromion and superior humeral head. The occupation ratio was calculated as the tendon thickness as a percentage of AHD.Results: The subacromial impingement syndrome group had a significantly thicker tendon (mean difference = 0.6 mm, p = 0.048) and a greater tendon occupation ratio (mean difference = 7.5 %, p = 0.014) compared to matched controls. There were no AHD group differences.Conclusions: The supraspinatus tendon was thicker and occupied a greater percentage of AHD, supporting an intrinsic mechanism. An extrinsic mechanism of tendon compression is theoretically supported, but future imaging studies need to confirm direct compression with elevation. Treatment to reduce tendon thickness may reduce symptoms, and surgical intervention to increase subacromial space may be considered if tendon compression can be verified.
- 5 June 2013
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (2) , 363-369
Supraspinatus tendon and subacromial space parameters measured on ultrasonographic imaging in subacromial impingement syndrome
Purpose: To characterize the supraspinatus tendon thickness, subacromial space, and the relationship between tendon thickness and subacromial space to further elucidate the mechanisms of subacromial impingement syndrome.Methods: In a single‐blind cross‐sectional study, subjects were recruited with subacromial impingement syndrome (n = 20) and asymptomatic controls (n = 20) matched for age, gender, and hand dominance. Ultrasound images were collected using a 4–12‐MHz linear transducer in B‐mode of the supraspinatus tendon in the transverse (short axis) and the anterior aspect of the subacromial space outlet. Using image callipers, measurements of tendon thickness were taken at 3 points along the tendon and averaged for a single thickness measure. The subacromial space outlet was measured via the acromiohumeral distance (AHD) defined by the inferior acromion and superior humeral head. The occupation ratio was calculated as the tendon thickness as a percentage of AHD.Results: The subacromial impingement syndrome group had a significantly thicker tendon (mean difference = 0.6 mm, p = 0.048) and a greater tendon occupation ratio (mean difference = 7.5 %, p = 0.014) compared to matched controls. There were no AHD group differences.Conclusions: The supraspinatus tendon was thicker and occupied a greater percentage of AHD, supporting an intrinsic mechanism. An extrinsic mechanism of tendon compression is theoretically supported, but future imaging studies need to confirm direct compression with elevation. Treatment to reduce tendon thickness may reduce symptoms, and surgical intervention to increase subacromial space may be considered if tendon compression can be verified.
- 1 April 2013
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 94 (4) , 725-730
Defining Substantial Clinical Benefit for Patient-Rated Outcome Tools for Shoulder Impingement Syndrome
- 1 April 2013
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 94 (4) , 725-730
Defining Substantial Clinical Benefit for Patient-Rated Outcome Tools for Shoulder Impingement Syndrome
- 1 February 2013
- Published by Elsevier in Manual Therapy
- Vol. 18 (1) , 60-64
Development of a sham comparator for thoracic spinal manipulative therapy for use with shoulder disorders
- 1 February 2013
- Published by Elsevier in Manual Therapy
- Vol. 18 (1) , 60-64
Development of a sham comparator for thoracic spinal manipulative therapy for use with shoulder disorders
- 1 February 2011
- Published by Human Kinetics in Journal of Sport Rehabilitation
- Vol. 20 (1) , 115-128
Responsiveness of the Numeric Pain Rating Scale in Patients With Shoulder Pain and the Effect of Surgical Status
Context: The Numeric Pain Rating Scale (NPRS) is commonly used to assess pain. Change in the NPRS across time can be interpreted with responsiveness indices.Objective: To determine the minimal clinically important difference (MCID) of the NPRS.Design: Single-group repeated measures.Setting: Outpatient rehabilitation clinics.Patients: Patients with shoulder pain (N = 136).Main Outcome Measures: At the initial evaluation patients completed the Penn Shoulder Score (PSS), which includes pain, satisfaction, and function sections. Pain was measured using an 11-point NPRS for 3 conditions of pain: at rest, with normal daily activities, and with strenuous activities. The NPRS average was calculated by averaging the NPRS scores for 3 conditions of pain. The final PSS was completed after 3–4 wk of rehabilitation. To determine the MCID for the NPRS average, the minimal detectible change of 8.6 points for the PSS function scale (0–60 points) was used as an external criterion anchor to classify patients as meaningfully improved (≥8.6 point change) or not improved (<8.6-point change). The MCID for the NPRS average was also determined for subgroups of surgical and nonsurgical patients. Cohen’s effect sizes were calculated as a measure of group responsiveness for the NPRS average.Results: Using a receiver-operating-characteristic analysis, the MCID for the average NPRS for all patients was 2.17, and it was 2.17 for both the surgical and nonsurgical subgroup: area-under-the-curve range .74–.76 (95%CI: .55–.95). The effect size for all patients was 1.84, and it was 1.51 and 1.94 for the surgical and nonsurgical groups, respectively.Conclusions: The NPRS average of 3 pain questions demonstrated responsiveness with an MCID of 2.17 in patients with shoulder pain receiving rehabilitation for 3–4 wk. The effect sizes indicated a large effect. However, responsiveness values are not static. Further research is indicated to assess responsiveness of the NPRS average in different types of patients with shoulder pain.
- 1 February 2011
- Published by Human Kinetics in Journal of Sport Rehabilitation
- Vol. 20 (1) , 115-128
Responsiveness of the Numeric Pain Rating Scale in Patients With Shoulder Pain and the Effect of Surgical Status
Context: The Numeric Pain Rating Scale (NPRS) is commonly used to assess pain. Change in the NPRS across time can be interpreted with responsiveness indices.Objective: To determine the minimal clinically important difference (MCID) of the NPRS.Design: Single-group repeated measures.Setting: Outpatient rehabilitation clinics.Patients: Patients with shoulder pain (N = 136).Main Outcome Measures: At the initial evaluation patients completed the Penn Shoulder Score (PSS), which includes pain, satisfaction, and function sections. Pain was measured using an 11-point NPRS for 3 conditions of pain: at rest, with normal daily activities, and with strenuous activities. The NPRS average was calculated by averaging the NPRS scores for 3 conditions of pain. The final PSS was completed after 3–4 wk of rehabilitation. To determine the MCID for the NPRS average, the minimal detectible change of 8.6 points for the PSS function scale (0–60 points) was used as an external criterion anchor to classify patients as meaningfully improved (≥8.6 point change) or not improved (<8.6-point change). The MCID for the NPRS average was also determined for subgroups of surgical and nonsurgical patients. Cohen’s effect sizes were calculated as a measure of group responsiveness for the NPRS average.Results: Using a receiver-operating-characteristic analysis, the MCID for the average NPRS for all patients was 2.17, and it was 2.17 for both the surgical and nonsurgical subgroup: area-under-the-curve range .74–.76 (95%CI: .55–.95). The effect size for all patients was 1.84, and it was 1.51 and 1.94 for the surgical and nonsurgical groups, respectively.Conclusions: The NPRS average of 3 pain questions demonstrated responsiveness with an MCID of 2.17 in patients with shoulder pain receiving rehabilitation for 3–4 wk. The effect sizes indicated a large effect. However, responsiveness values are not static. Further research is indicated to assess responsiveness of the NPRS average in different types of patients with shoulder pain.
- 1 February 2011
- Published by Human Kinetics in Journal of Sport Rehabilitation
- Vol. 20 (1) , 37-45
Patient- and Clinician-Rated Outcome Measures for Clinical Decision Making in Rehabilitation
Outcome measures can be classified as clinician rated and patient rated. Clinician-rated measures predominantly assess impairments, whereas patient-rated measures, also known as patient-based measures, are designed to evaluate the impact of the injury on a patient’s daily activities, work, and recreation. Currently, there is a greater reliance on clinician-rated impairment measures for clinical decision making, specifically with treatment planning and assessing outcomes of care. To comprehensively evaluate the effect of an injury, patient-rated outcome measures must be used because they allow for the assessment of a patient’s ability to perform daily activities and participate in work and recreation that is affected by an injury. Clinician-rated impairment measures should be used to guide the development of a treatment program, and patient-rated measures should be used for both treatment-program development and assessing treatment outcomes in daily clinical practice. The purposes of this article are to describe patient- and clinician-rated outcome measures and to provide guidance and illustrate the benefits of the use of these measures in clinical decision making and documenting outcomes of care.
- 1 February 2011
- Published by Human Kinetics in Journal of Sport Rehabilitation
- Vol. 20 (1) , 37-45
Patient- and Clinician-Rated Outcome Measures for Clinical Decision Making in Rehabilitation
Outcome measures can be classified as clinician rated and patient rated. Clinician-rated measures predominantly assess impairments, whereas patient-rated measures, also known as patient-based measures, are designed to evaluate the impact of the injury on a patient’s daily activities, work, and recreation. Currently, there is a greater reliance on clinician-rated impairment measures for clinical decision making, specifically with treatment planning and assessing outcomes of care. To comprehensively evaluate the effect of an injury, patient-rated outcome measures must be used because they allow for the assessment of a patient’s ability to perform daily activities and participate in work and recreation that is affected by an injury. Clinician-rated impairment measures should be used to guide the development of a treatment program, and patient-rated measures should be used for both treatment-program development and assessing treatment outcomes in daily clinical practice. The purposes of this article are to describe patient- and clinician-rated outcome measures and to provide guidance and illustrate the benefits of the use of these measures in clinical decision making and documenting outcomes of care.
- 1 January 2011
- Published by National Athletic Trainers' Association in Journal of Athletic Training
- Vol. 46 (4) , 343-348
Diagnostic Accuracy of History and Physical Examination of Superior Labrum Anterior-Posterior Lesions
Context: Type I superior labrum anterior-posterior (SLAP) lesions involve degenerative fraying and probably are not the cause of shoulder pain. Type II to IV SLAP lesions are tears of the labrum. Objective: To determine the diagnostic accuracy of patient history and the active compression, anterior slide, and crank tests for type I and type II to IV SLAP lesions. Design: Cohort study. Setting: Clinic. Patients or Other Participants: Fifty-five patients (47 men, 8 women; age = 40.6 ± 15.1 years) presenting with shoulder pain. Intervention(s): For each patient, an orthopaedic surgeon conducted a clinical examination of history of trauma; sudden onset of symptoms; history of popping, clicking, or catching; age; and active compression, crank, and anterior slide tests. The reference standard was the intraoperative diagnosis. The operating surgeon was blinded to the results of the clinical examination. Main Outcome Measure(s): Diagnostic utility was calculated using the receiver operating characteristic curve and area under the curve (AUC), sensitivity, specificity, positive likelihood ratio (+LR), and negative likelihood ratio (−LR). Forward stepwise binary regression was used to determine a combination of tests for diagnosis. Results: No history item or physical examination test had diagnostic accuracy for type I SLAP lesions (n = 13). The anterior slide test had utility (AUC = 0.70, +LR = 2.25, −LR = 0.44) to confirm and exclude type II to IV SLAP lesions (n = 10). The combination of a history of popping, clicking, or catching and the anterior slide test demonstrated diagnostic utility for confirming type II to IV SLAP lesions (+LR = 6.00). Conclusions: The anterior slide test had limited diagnostic utility for confirming and excluding type II to IV SLAP lesions; diagnostic values indicated only small shifts in probability. However, the combination of the anterior slide test with a history of popping, clicking, or catching had moderate diagnostic utility for confirming type II to IV SLAP lesions. No single item or combination of history items and physical examination tests had diagnostic utility for type I SLAP lesions.
- 1 January 2011
- Published by National Athletic Trainers' Association in Journal of Athletic Training
- Vol. 46 (4) , 343-348
Diagnostic Accuracy of History and Physical Examination of Superior Labrum Anterior-Posterior Lesions
Context: Type I superior labrum anterior-posterior (SLAP) lesions involve degenerative fraying and probably are not the cause of shoulder pain. Type II to IV SLAP lesions are tears of the labrum. Objective: To determine the diagnostic accuracy of patient history and the active compression, anterior slide, and crank tests for type I and type II to IV SLAP lesions. Design: Cohort study. Setting: Clinic. Patients or Other Participants: Fifty-five patients (47 men, 8 women; age = 40.6 ± 15.1 years) presenting with shoulder pain. Intervention(s): For each patient, an orthopaedic surgeon conducted a clinical examination of history of trauma; sudden onset of symptoms; history of popping, clicking, or catching; age; and active compression, crank, and anterior slide tests. The reference standard was the intraoperative diagnosis. The operating surgeon was blinded to the results of the clinical examination. Main Outcome Measure(s): Diagnostic utility was calculated using the receiver operating characteristic curve and area under the curve (AUC), sensitivity, specificity, positive likelihood ratio (+LR), and negative likelihood ratio (−LR). Forward stepwise binary regression was used to determine a combination of tests for diagnosis. Results: No history item or physical examination test had diagnostic accuracy for type I SLAP lesions (n = 13). The anterior slide test had utility (AUC = 0.70, +LR = 2.25, −LR = 0.44) to confirm and exclude type II to IV SLAP lesions (n = 10). The combination of a history of popping, clicking, or catching and the anterior slide test demonstrated diagnostic utility for confirming type II to IV SLAP lesions (+LR = 6.00). Conclusions: The anterior slide test had limited diagnostic utility for confirming and excluding type II to IV SLAP lesions; diagnostic values indicated only small shifts in probability. However, the combination of the anterior slide test with a history of popping, clicking, or catching had moderate diagnostic utility for confirming type II to IV SLAP lesions. No single item or combination of history items and physical examination tests had diagnostic utility for type I SLAP lesions.
- Top Cited Papers
- 1 November 2009
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 90 (11) , 1898-1903
Reliability and Diagnostic Accuracy of 5 Physical Examination Tests and Combination of Tests for Subacromial Impingement
- 1 November 2009
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 90 (11) , 1898-1903
Top Cited PapersReliability and Diagnostic Accuracy of 5 Physical Examination Tests and Combination of Tests for Subacromial Impingement
- 31 July 2008
- Published by Elsevier in Clinics in Sports Medicine
- Vol. 27 (3) , 491-505
Evaluation of Health-Related Quality of Life in Patients with Shoulder Pain: Are We Doing the Best We Can?
- 31 July 2008
- Published by Elsevier in Clinics in Sports Medicine
- Vol. 27 (3) , 491-505
Evaluation of Health-Related Quality of Life in Patients with Shoulder Pain: Are We Doing the Best We Can?
- Open Access
- 1 November 2005
- Published by Oxford University Press (OUP) in Physical Therapy
- Vol. 85 (11) , 1128-1138
Scapular Muscle Tests in Subjects With Shoulder Pain and Functional Loss: Reliability and Construct Validity
Background and Purpose. Scapular muscle performance evaluated with a handheld dynamometer (HHD) has been investigated only in people without shoulder dysfunction for test-retest reliability of data obtained with a single scapular muscle test. The purpose of this study was to assess the reliability, error, and validity of data obtained with an HHD for 4 scapular muscle tests in subjects with shoulder pain and functional loss. Subjects and Methods. Subjects (N=40) with shoulder pain and functional loss were tested bymeasuring the kilograms applied with an HHD during 3 trials for muscle tests for the lower trapezius, upper trapezius, middle trapezius, and serratus anterior muscles. Concurrently, surface electromyography (sEMG) data were collected for the 4 muscles. The same procedures were performed 24 to 72 hours after the initial testing by the same tester. Muscle tests were performed 3 times, and the results were averaged for data analysis. Results. Intraclass correlation coefficients for intratester reliability of measurements of isometricforce obtained using an HHD ranged from .89 to .96. The standard error of the measure (90% confidenceinterval [CI]) ranged from 1.3 to 2.7 kg; the minimal detectable change (90% CI) ranged from 1.8 to 3.6 kg. Construct validity assessment, done by comparing the amounts of isometric muscle activity (sEMG) for each muscle across the 4 muscle tests, revealed that the muscle activity of the upper trapezius and lower trapezius muscles washighest during their respective tests. Conversely, the isometric muscle activity of the middle trapezius and serratus anterior muscles was not highest during their respective tests. Discussion and Conclusion. In people with shoulder pain and functional loss, the intrarater reliability and error over 1 to 3 days were established using an HHD for measurement of isometric force for the assessment of scapular muscle performance. Error values can be used to make decisions regarding individual patients. Construct validity was established for the lower and upper trapezius muscle tests; therefore, these tests are advocated for use. However, construct validity was not demonstrated for the serratus anterior and middle trapezius muscle tests as performed in this study. Further investigation of these muscle tests is warranted.
- 1 November 2005
- Published by Oxford University Press (OUP) in Physical Therapy
- Vol. 85 (11) , 1128-1138
Open AccessScapular Muscle Tests in Subjects With Shoulder Pain and Functional Loss: Reliability and Construct Validity
Background and Purpose. Scapular muscle performance evaluated with a handheld dynamometer (HHD) has been investigated only in people without shoulder dysfunction for test-retest reliability of data obtained with a single scapular muscle test. The purpose of this study was to assess the reliability, error, and validity of data obtained with an HHD for 4 scapular muscle tests in subjects with shoulder pain and functional loss. Subjects and Methods. Subjects (N=40) with shoulder pain and functional loss were tested bymeasuring the kilograms applied with an HHD during 3 trials for muscle tests for the lower trapezius, upper trapezius, middle trapezius, and serratus anterior muscles. Concurrently, surface electromyography (sEMG) data were collected for the 4 muscles. The same procedures were performed 24 to 72 hours after the initial testing by the same tester. Muscle tests were performed 3 times, and the results were averaged for data analysis. Results. Intraclass correlation coefficients for intratester reliability of measurements of isometricforce obtained using an HHD ranged from .89 to .96. The standard error of the measure (90% confidenceinterval [CI]) ranged from 1.3 to 2.7 kg; the minimal detectable change (90% CI) ranged from 1.8 to 3.6 kg. Construct validity assessment, done by comparing the amounts of isometric muscle activity (sEMG) for each muscle across the 4 muscle tests, revealed that the muscle activity of the upper trapezius and lower trapezius muscles washighest during their respective tests. Conversely, the isometric muscle activity of the middle trapezius and serratus anterior muscles was not highest during their respective tests. Discussion and Conclusion. In people with shoulder pain and functional loss, the intrarater reliability and error over 1 to 3 days were established using an HHD for measurement of isometric force for the assessment of scapular muscle performance. Error values can be used to make decisions regarding individual patients. Construct validity was established for the lower and upper trapezius muscle tests; therefore, these tests are advocated for use. However, construct validity was not demonstrated for the serratus anterior and middle trapezius muscle tests as performed in this study. Further investigation of these muscle tests is warranted.