Tobias Ruess
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tobias Ruess has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Manfred Thumm
Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
10 shared publications - John Jelonnek
Karlsruhe Institute of Technology
9 shared publications - Gerd Gantenbein
Institute for Pulsed Power and Microwave Technology, Karlsruhe Institute of Technology, Karlsruhe, Germany
7 shared publications - Zisis C. Ioannidis
Department of Aerospace Science and Technology, National and Kapodistrian University of Athens, Euripus Campus, Psachna, Greece
7 shared publications - Gaetano Aiello
Institute for Applied Materials (IAM), Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen, Germany
4 shared publications - Ioannis Gr. Pagonakis
ETH Zürich, Institute of Molecular Physical Science (IMPS) 1 , CH-8093 Zürich
4 shared publications
Latest Publications
- Open Access
- 31 March 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 215
Robustness of the E×B MDC prototype design for gyrotrons
- 31 March 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 215
Open AccessRobustness of the E×B MDC prototype design for gyrotrons
- Open Access
- 1 January 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (1)
Development of the 174 GHz collective Thomson scattering diagnostics at Wendelstein 7-X
In this paper, we present the design and commissioning results of the upgraded collective Thomson scattering diagnostic at the Wendelstein 7-X stellarator. The diagnostic has a new radiometer designed to operate between the second and third harmonics of the electron cyclotron emission from the plasma at 171–177 GHz, where the emission background has a minimum and is of order 10–100 eV. It allows us to receive the scattered electromagnetic field with a significantly improved signal-to-noise ratio and extends the set of possible scattering geometries compared to the case of the original instrument operated at 140 GHz. The elements of the diagnostic are a narrowband notch filter and a frequency stabilized probing gyrotron that will allow measuring scattered radiation spectra very close to the probing frequency. Here, we characterize the microwave components applied to the radiometer and demonstrate the performance of the complete system that was achieved during the latest experimental campaign, OP2.1.
- 1 January 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (1)
Open AccessDevelopment of the 174 GHz collective Thomson scattering diagnostics at Wendelstein 7-X
In this paper, we present the design and commissioning results of the upgraded collective Thomson scattering diagnostic at the Wendelstein 7-X stellarator. The diagnostic has a new radiometer designed to operate between the second and third harmonics of the electron cyclotron emission from the plasma at 171–177 GHz, where the emission background has a minimum and is of order 10–100 eV. It allows us to receive the scattered electromagnetic field with a significantly improved signal-to-noise ratio and extends the set of possible scattering geometries compared to the case of the original instrument operated at 140 GHz. The elements of the diagnostic are a narrowband notch filter and a frequency stabilized probing gyrotron that will allow measuring scattered radiation spectra very close to the probing frequency. Here, we characterize the microwave components applied to the radiometer and demonstrate the performance of the complete system that was achieved during the latest experimental campaign, OP2.1.
- 16 December 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (2) , 85-96
Frequency and mode measurement techniques for megawatt-class gyrotrons
State-of-the-art vacuum electron tubes such as gyrotrons, deliver RF output powers up to more than 2 MW at frequencies up to 170 GHz. In terms of the very high power levels, a proper verification of the gyrotron components itself and measurements during gyrotron operation are vital to prevent possible fatal errors. Several basic RF measurement setups, which are used at IHM/KIT, are discussed. Currently, their upper frequency limit is 175 GHz. In terms of future gyrotron operation above 200 GHz, upgrades of the measurement setups for operation up to 260–330 GHz are prepared. The experimental devices discussed herein are a quasi-optical mode generator for the verification of the quasi-optical gyrotron output system, the window measurement test stand to verify the ceramic gyrotron output window and the frequency diagnostic system to measure the operating frequency and thereby the excited mode.
- 16 December 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (2) , 85-96
Frequency and mode measurement techniques for megawatt-class gyrotrons
State-of-the-art vacuum electron tubes such as gyrotrons, deliver RF output powers up to more than 2 MW at frequencies up to 170 GHz. In terms of the very high power levels, a proper verification of the gyrotron components itself and measurements during gyrotron operation are vital to prevent possible fatal errors. Several basic RF measurement setups, which are used at IHM/KIT, are discussed. Currently, their upper frequency limit is 175 GHz. In terms of future gyrotron operation above 200 GHz, upgrades of the measurement setups for operation up to 260–330 GHz are prepared. The experimental devices discussed herein are a quasi-optical mode generator for the verification of the quasi-optical gyrotron output system, the window measurement test stand to verify the ceramic gyrotron output window and the frequency diagnostic system to measure the operating frequency and thereby the excited mode.
- Open Access
Plasma Spraying of a Microwave Absorber Coating for an RF Dummy Load
The European fusion reactor research facility, called International Thermonuclear Experimental Reactor (ITER), is one of the most challenging projects that involves design and testing of hundreds of separately designed reactor elements and peripheric modules. One of the core elements involved in plasma heating are gyrotrons. They are used as a microwave source in electron–cyclotron resonance heating systems (ECRH) for variable injection of RF power into the plasma ring. In this work, the development and application of an alumina-titania 60/40 mixed oxide ceramic absorber coating on a copper cylinder is described. The cylinder is part of a dummy load used in gyrotron testing and its purpose is to absorb microwave radiation generated by gyrotrons during testing phase. The coating is applied by means of atmospheric plasma spraying (APS). The absorber coating is deposited on the inner diameter of a one-meter cylindrical tube. To ensure homogeneous radiation absorption when the incoming microwave beam is repeatedly scattered along the inner tube surface, the coating shows a varying thickness as a function of the tube length. By this it is ensured that the thermal power is distributed homogeneously on the entire inner tube surface. This paper describes a modeling approach of the coating thickness distribution, the manufacturing concept for the internal plasma spray coating and the coating characterization with regard to coating microstructure and microwave absorption characteristics.
Open AccessPlasma Spraying of a Microwave Absorber Coating for an RF Dummy Load
The European fusion reactor research facility, called International Thermonuclear Experimental Reactor (ITER), is one of the most challenging projects that involves design and testing of hundreds of separately designed reactor elements and peripheric modules. One of the core elements involved in plasma heating are gyrotrons. They are used as a microwave source in electron–cyclotron resonance heating systems (ECRH) for variable injection of RF power into the plasma ring. In this work, the development and application of an alumina-titania 60/40 mixed oxide ceramic absorber coating on a copper cylinder is described. The cylinder is part of a dummy load used in gyrotron testing and its purpose is to absorb microwave radiation generated by gyrotrons during testing phase. The coating is applied by means of atmospheric plasma spraying (APS). The absorber coating is deposited on the inner diameter of a one-meter cylindrical tube. To ensure homogeneous radiation absorption when the incoming microwave beam is repeatedly scattered along the inner tube surface, the coating shows a varying thickness as a function of the tube length. By this it is ensured that the thermal power is distributed homogeneously on the entire inner tube surface. This paper describes a modeling approach of the coating thickness distribution, the manufacturing concept for the internal plasma spray coating and the coating characterization with regard to coating microstructure and microwave absorption characteristics.
- 1 March 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 164
Towards a 1.5 MW, 140 GHz gyrotron for the upgraded ECRH system at W7-X
- 1 March 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 164
Towards a 1.5 MW, 140 GHz gyrotron for the upgraded ECRH system at W7-X
- Open Access
- 8 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Recent Development of a 1.5 MW, 140 GHz Continuous-Wave Gyrotron for the Upgraded ECRH System at W7-X
To increase the total injected Electron Cyclotron Resonance Heating (ECRH) power in the plasma of the nuclear fusion experiment Wendelstein 7-X (W7-X), an upgrade of the existing gyrotron installation is in progress. The existing ECRH system, currently equipped with ten one-MW-class, 140 GHz continuous wave (CW) gyrotrons, will be augmented by enhanced 1.5 MW tubes, which are based on the successful existing 1 MW gyrotron design.
- 8 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Open AccessRecent Development of a 1.5 MW, 140 GHz Continuous-Wave Gyrotron for the Upgraded ECRH System at W7-X
To increase the total injected Electron Cyclotron Resonance Heating (ECRH) power in the plasma of the nuclear fusion experiment Wendelstein 7-X (W7-X), an upgrade of the existing gyrotron installation is in progress. The existing ECRH system, currently equipped with ten one-MW-class, 140 GHz continuous wave (CW) gyrotrons, will be augmented by enhanced 1.5 MW tubes, which are based on the successful existing 1 MW gyrotron design.
- Open Access
- 25 March 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 203, 04014
Theoretical Study on the Operation of the EU/KIT TE34,19-Mode Coaxial-Cavity Gyrotron at 170/204/238 GHz
The 170 GHz 2 MW TE34,19-mode coaxial-cavity modular short-pulse pre-prototype gyrotron at KIT was recently modified in order to verify the multi-megawatt coaxial-cavity technology at longer pulses. In parallel, theoretical investigations on a possibility to operate the 170 GHz TE34,19-mode coaxial-cavity prototype at multiple frequencies up to 238 GHz have been started, with a goal to find a configuration at which the tube could operate in the KIT FULGOR gyrotron test facility using the new 10.5 T SC magnet. This paper indicates which adjustments have to be made and show the feasibility of the multi-frequency operation. Small modifications at the gyrotron cavity will support an RF output power of more than 2 MW at 170/204 GHz. Furthermore, a new gyrotron launcher has been designed capable of producing a Gaussian microwave beam with a Gaussian mode content of more than 96% at these frequencies.
- 25 March 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 203, 04014
Open AccessTheoretical Study on the Operation of the EU/KIT TE34,19-Mode Coaxial-Cavity Gyrotron at 170/204/238 GHz
The 170 GHz 2 MW TE34,19-mode coaxial-cavity modular short-pulse pre-prototype gyrotron at KIT was recently modified in order to verify the multi-megawatt coaxial-cavity technology at longer pulses. In parallel, theoretical investigations on a possibility to operate the 170 GHz TE34,19-mode coaxial-cavity prototype at multiple frequencies up to 238 GHz have been started, with a goal to find a configuration at which the tube could operate in the KIT FULGOR gyrotron test facility using the new 10.5 T SC magnet. This paper indicates which adjustments have to be made and show the feasibility of the multi-frequency operation. Small modifications at the gyrotron cavity will support an RF output power of more than 2 MW at 170/204 GHz. Furthermore, a new gyrotron launcher has been designed capable of producing a Gaussian microwave beam with a Gaussian mode content of more than 96% at these frequencies.
- 5 January 2019
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 40 (3) , 257-268
Computer-Controlled Test System for the Excitation of Very High-Order Modes in Highly Oversized Waveguides
- 5 January 2019
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 40 (3) , 257-268
Computer-Controlled Test System for the Excitation of Very High-Order Modes in Highly Oversized Waveguides
- Open Access
- 3 September 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 187, 01009
2018 Status on KIT Gyrotron Activities
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 3 September 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 187, 01009
Open Access2018 Status on KIT Gyrotron Activities
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- Open Access
- 3 September 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 187, 01019
2018 Status of the Measurement Capabilities for Fusion Gyrotrons at KIT/IHM
This paper gives an overview about three key measurement capabilities at KIT/IHM for fusion gyrotrons. The discussed topics are: RF window test facility, low power launcher test setup and the frequency measurement setup placed at the high power test facility. Further, approaches for upgrading the setups to frequencies above 200 GHz are discussed.
- 3 September 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 187, 01019
Open Access2018 Status of the Measurement Capabilities for Fusion Gyrotrons at KIT/IHM
This paper gives an overview about three key measurement capabilities at KIT/IHM for fusion gyrotrons. The discussed topics are: RF window test facility, low power launcher test setup and the frequency measurement setup placed at the high power test facility. Further, approaches for upgrading the setups to frequencies above 200 GHz are discussed.