Frank J. H. Gijsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Frank J. H. Gijsen has a total of 274 co-authors. Here are the top co-authors by number of shared publications:
Jolanda J. Wentzel
Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, Rotterdam, The Netherlands
14 shared publications- Antonius F. W. van der Steen
Biomedical Engineering, Department of Cardiology, Cardiovascular Institute, Erasmus MC, Rotterdam, The Netherlands
12 shared publications - Jolanda J. Wentzel
Department of Cardiology, Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands
10 shared publications - Ali Cagdas Akyildiz
Department of Cardiology, Biomedical Engineering, Cardiovascular Institute, Thorax Center, Erasmus MC, Rotterdam, the Netherlands; Department of Biomechanical Engineering, Delft University of Technology, Delft, the Netherlands
9 shared publications - Kim Van der Heiden
Department of Biomedical Engineering, Thorax Center, Erasmus MC, Rotterdam, The Netherlands
8 shared publications Aad van der Lugt
Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands
7 shared publications
Latest Publications
- Open Access
- 8 May 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (10) , 3274
Morphometry of Intracranial Carotid Artery Calcifications in Patients with Recent Cerebral Ischemia
Background: Intracranial artery calcification detected on CT imaging is a recognized risk factor for ischemic cerebrovascular diseases, but the underlying etiology of this association remains unclear. Differences in objective morphometric characteristics of these calcifications may partially explain this association, yet these measurements are largely absent in the literature. We investigated intracranial artery calcification morphometry in patients with recent anterior ischemic stroke or TIA, assessing potential differences between calcifications in both intracranial carotid arteries (ICAs) located ipsilateral and contralateral to the cerebral ischemia. Methods: Among 100 patients (mean age 69.6 (SD 8.8) years) presenting to academic neurology departments, 3D reconstructions of both ICAs were based on clinical CT-angiography images. On these reconstructions, a luminal centerline and cross-sections perpendicular to this centerline were created, facilitating the assessment of calcification morphometry, spatial orientation and stenosis severity. Differences in calcification characteristics between ICAs were assessed using two-sided Wilcoxon signed-rank and χ2 tests. Results: Among 200 arteries, a median of four (IQR 2–6) individual calcifications were counted, with a mean area of 1.8 (IQR 1.2–2.7) mm2, a mean arc width of 43.5 (IQR 32.3–53.2) degrees, and median longitudinal extent of 15.4 (IQR 5.9–27.0) mm. Calcifications were most often present in the anatomical C4 section (56.0%), with predominantly posterosuperior orientation (38.5%) and 42.0% had a local stenosis severity > 70%. None of these aspects significantly differed between ICAs, and this remained after restricting analyses to patients with undetermined etiology. Conclusions: We found no differences in morphometrical or spatial aspects of calcifications between ICAs ipsilateral and contralateral to the cerebral ischemia.
- 8 May 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (10) , 3274
Open AccessMorphometry of Intracranial Carotid Artery Calcifications in Patients with Recent Cerebral Ischemia
Background: Intracranial artery calcification detected on CT imaging is a recognized risk factor for ischemic cerebrovascular diseases, but the underlying etiology of this association remains unclear. Differences in objective morphometric characteristics of these calcifications may partially explain this association, yet these measurements are largely absent in the literature. We investigated intracranial artery calcification morphometry in patients with recent anterior ischemic stroke or TIA, assessing potential differences between calcifications in both intracranial carotid arteries (ICAs) located ipsilateral and contralateral to the cerebral ischemia. Methods: Among 100 patients (mean age 69.6 (SD 8.8) years) presenting to academic neurology departments, 3D reconstructions of both ICAs were based on clinical CT-angiography images. On these reconstructions, a luminal centerline and cross-sections perpendicular to this centerline were created, facilitating the assessment of calcification morphometry, spatial orientation and stenosis severity. Differences in calcification characteristics between ICAs were assessed using two-sided Wilcoxon signed-rank and χ2 tests. Results: Among 200 arteries, a median of four (IQR 2–6) individual calcifications were counted, with a mean area of 1.8 (IQR 1.2–2.7) mm2, a mean arc width of 43.5 (IQR 32.3–53.2) degrees, and median longitudinal extent of 15.4 (IQR 5.9–27.0) mm. Calcifications were most often present in the anatomical C4 section (56.0%), with predominantly posterosuperior orientation (38.5%) and 42.0% had a local stenosis severity > 70%. None of these aspects significantly differed between ICAs, and this remained after restricting analyses to patients with undetermined etiology. Conclusions: We found no differences in morphometrical or spatial aspects of calcifications between ICAs ipsilateral and contralateral to the cerebral ischemia.
- Open Access
- 25 April 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (8) , 2151-2161
Contribution of Red Blood Cells and Platelets to Blood Clot Computed Tomography Imaging and Compressive Mechanical Characteristics
Thrombus computed tomography (CT) imaging characteristics may correspond with thrombus mechanical properties and thus predict thrombectomy success. The impact of red blood cell (RBC) content on these properties (imaging and mechanics) has been widely studied. However, the additional effect of platelets has not been considered. The objective of the current study was to examine the individual and combined effects of blood clot RBC and platelet content on resultant CT imaging and mechanical characteristics. Human blood clot analogues were prepared from a combination of preselected RBC volumes and platelet concentrations to decouple their contributions. The resulting clot RBC content (%) and platelet content (%) were determined using Martius Scarlet Blue and CD42b staining, respectively. Non-contrast and contrast-enhanced CT (NCCT and CECT) scans were performed to measure the clot densities. CECT density increase was taken as a proxy for clinical perviousness. Unconfined compressive mechanics were analysed by performing 10 cycles of 80% strain. RBC content is the major determinant of clot NCCT density. However, additional consideration of the platelet content improves the association. CECT density increase is influenced by clot platelet and not RBC content. Platelet content is the dominant component driving clot stiffness, especially at high strains. Both RBC and platelet content contribute to the clot’s viscoelastic and plastic compressive properties. The current in vitro results suggest that CT density is reflective of RBC content and subsequent clot viscoelasticity and plasticity, and that perviousness reflects the clot’s platelet content and subsequent stiffness. However, these indications should be confirmed in a clinical stroke cohort.
- 25 April 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (8) , 2151-2161
Open AccessContribution of Red Blood Cells and Platelets to Blood Clot Computed Tomography Imaging and Compressive Mechanical Characteristics
Thrombus computed tomography (CT) imaging characteristics may correspond with thrombus mechanical properties and thus predict thrombectomy success. The impact of red blood cell (RBC) content on these properties (imaging and mechanics) has been widely studied. However, the additional effect of platelets has not been considered. The objective of the current study was to examine the individual and combined effects of blood clot RBC and platelet content on resultant CT imaging and mechanical characteristics. Human blood clot analogues were prepared from a combination of preselected RBC volumes and platelet concentrations to decouple their contributions. The resulting clot RBC content (%) and platelet content (%) were determined using Martius Scarlet Blue and CD42b staining, respectively. Non-contrast and contrast-enhanced CT (NCCT and CECT) scans were performed to measure the clot densities. CECT density increase was taken as a proxy for clinical perviousness. Unconfined compressive mechanics were analysed by performing 10 cycles of 80% strain. RBC content is the major determinant of clot NCCT density. However, additional consideration of the platelet content improves the association. CECT density increase is influenced by clot platelet and not RBC content. Platelet content is the dominant component driving clot stiffness, especially at high strains. Both RBC and platelet content contribute to the clot’s viscoelastic and plastic compressive properties. The current in vitro results suggest that CT density is reflective of RBC content and subsequent clot viscoelasticity and plasticity, and that perviousness reflects the clot’s platelet content and subsequent stiffness. However, these indications should be confirmed in a clinical stroke cohort.
- Open Access
- 1 September 2023
- Published by AIP Publishing in APL Bioengineering
- Vol. 7 (3) , 036120
A tissue-engineered model of the atherosclerotic plaque cap: Toward understanding the role of microcalcifications in plaque rupture
Rupture of the cap of an atherosclerotic plaque can lead to thrombotic cardiovascular events. It has been suggested, through computational models, that the presence of microcalcifications in the atherosclerotic cap can increase the risk of cap rupture. However, the experimental confirmation of this hypothesis is still lacking. In this study, we have developed a novel tissue-engineered model to mimic the atherosclerotic fibrous cap with microcalcifications and assess the impact of microcalcifications on cap mechanics. First, human carotid plaque caps were analyzed to determine the distribution, size, and density of microcalcifications in real cap tissue. Hydroxyapatite particles with features similar to real cap microcalcifications were used as microcalcification mimics. Injected clusters of hydroxyapatite particles were embedded in a fibrin gel seeded with human myofibroblasts which deposited a native-like collagenous matrix around the particles, during the 21-day culture period. Second harmonic multiphoton microscopy imaging revealed higher local collagen fiber dispersion in regions of hydroxyapatite clusters. Tissue-engineered caps with hydroxyapatite particles demonstrated lower stiffness and ultimate tensile stress than the control group samples under uniaxial tensile loading, suggesting increased rupture risk in atherosclerotic plaques with microcalcifications. This model supports previous computational findings regarding a detrimental role for microcalcifications in cap rupture risk and can further be deployed to elucidate tissue mechanics in pathologies with calcifying soft tissues.
- 1 September 2023
- Published by AIP Publishing in APL Bioengineering
- Vol. 7 (3) , 036120
Open AccessA tissue-engineered model of the atherosclerotic plaque cap: Toward understanding the role of microcalcifications in plaque rupture
Rupture of the cap of an atherosclerotic plaque can lead to thrombotic cardiovascular events. It has been suggested, through computational models, that the presence of microcalcifications in the atherosclerotic cap can increase the risk of cap rupture. However, the experimental confirmation of this hypothesis is still lacking. In this study, we have developed a novel tissue-engineered model to mimic the atherosclerotic fibrous cap with microcalcifications and assess the impact of microcalcifications on cap mechanics. First, human carotid plaque caps were analyzed to determine the distribution, size, and density of microcalcifications in real cap tissue. Hydroxyapatite particles with features similar to real cap microcalcifications were used as microcalcification mimics. Injected clusters of hydroxyapatite particles were embedded in a fibrin gel seeded with human myofibroblasts which deposited a native-like collagenous matrix around the particles, during the 21-day culture period. Second harmonic multiphoton microscopy imaging revealed higher local collagen fiber dispersion in regions of hydroxyapatite clusters. Tissue-engineered caps with hydroxyapatite particles demonstrated lower stiffness and ultimate tensile stress than the control group samples under uniaxial tensile loading, suggesting increased rupture risk in atherosclerotic plaques with microcalcifications. This model supports previous computational findings regarding a detrimental role for microcalcifications in cap rupture risk and can further be deployed to elucidate tissue mechanics in pathologies with calcifying soft tissues.
- Open Access
- 18 April 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (8) , 1759-1768
Tensile and Compressive Mechanical Behaviour of Human Blood Clot Analogues
Endovascular thrombectomy procedures are significantly influenced by the mechanical response of thrombi to the multi-axial loading imposed during retrieval. Compression tests are commonly used to determine compressiveex vivothrombus and clot analogue stiffness. However, there is a shortage of data in tension. This study compares the tensile and compressive response of clot analogues made from the blood of healthy human donors in a range of compositions. Citrated whole blood was collected from six healthy human donors. Contracted and non-contracted fibrin clots, whole blood clots and clots reconstructed with a range of red blood cell (RBC) volumetric concentrations (5–80%) were prepared under static conditions. Both uniaxial tension and unconfined compression tests were performed using custom-built setups. Approximately linear nominal stress–strain profiles were found under tension, while strong strain-stiffening profiles were observed under compression. Low- and high-strain stiffness values were acquired by applying a linear fit to the initial and final 10% of the nominal stress–strain curves. Tensile stiffness values were approximately 15 times higher than low-strain compressive stiffness and 40 times lower than high-strain compressive stiffness values. Tensile stiffness decreased with an increasing RBC volume in the blood mixture. In contrast, high-strain compressive stiffness values increased from 0 to 10%, followed by a decrease from 20 to 80% RBC volumes. Furthermore, inter-donor differences were observed with up to 50% variation in the stiffness of whole blood clot analogues prepared in the same manner between healthy human donors.
- 18 April 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (8) , 1759-1768
Open AccessTensile and Compressive Mechanical Behaviour of Human Blood Clot Analogues
Endovascular thrombectomy procedures are significantly influenced by the mechanical response of thrombi to the multi-axial loading imposed during retrieval. Compression tests are commonly used to determine compressiveex vivothrombus and clot analogue stiffness. However, there is a shortage of data in tension. This study compares the tensile and compressive response of clot analogues made from the blood of healthy human donors in a range of compositions. Citrated whole blood was collected from six healthy human donors. Contracted and non-contracted fibrin clots, whole blood clots and clots reconstructed with a range of red blood cell (RBC) volumetric concentrations (5–80%) were prepared under static conditions. Both uniaxial tension and unconfined compression tests were performed using custom-built setups. Approximately linear nominal stress–strain profiles were found under tension, while strong strain-stiffening profiles were observed under compression. Low- and high-strain stiffness values were acquired by applying a linear fit to the initial and final 10% of the nominal stress–strain curves. Tensile stiffness values were approximately 15 times higher than low-strain compressive stiffness and 40 times lower than high-strain compressive stiffness values. Tensile stiffness decreased with an increasing RBC volume in the blood mixture. In contrast, high-strain compressive stiffness values increased from 0 to 10%, followed by a decrease from 20 to 80% RBC volumes. Furthermore, inter-donor differences were observed with up to 50% variation in the stiffness of whole blood clot analogues prepared in the same manner between healthy human donors.
- Open Access
- 31 March 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-13
Tissue-engineered collagenous fibrous cap models to systematically elucidate atherosclerotic plaque rupture
A significant amount of vascular thrombotic events are associated with rupture of the fibrous cap that overlie atherosclerotic plaques. Cap rupture is however difficult to predict due to the heterogenous composition of the plaque, unknown material properties, and the stochastic nature of the event. Here, we aim to create tissue engineered human fibrous cap models with a variable but controllable collagen composition, suitable for mechanical testing, to scrutinize the reciprocal relationships between composition and mechanical properties. Myofibroblasts were cultured in 1 × 1.5 cm-sized fibrin-based constrained gels for 21 days according to established (dynamic) culture protocols (i.e. static, intermittent or continuous loading) to vary collagen composition (e.g. amount, type and organization). At day 7, a soft 2 mm ∅ fibrin inclusion was introduced in the centre of each tissue to mimic the soft lipid core, simulating the heterogeneity of a plaque. Results demonstrate reproducible collagenous tissues, that mimic the bulk mechanical properties of human caps and vary in collagen composition due to the presence of a successfully integrated soft inclusion and the culture protocol applied. The models can be deployed to assess tissue mechanics, evolution and failure of fibrous caps or complex heterogeneous tissues in general.
- 31 March 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-13
Open AccessTissue-engineered collagenous fibrous cap models to systematically elucidate atherosclerotic plaque rupture
A significant amount of vascular thrombotic events are associated with rupture of the fibrous cap that overlie atherosclerotic plaques. Cap rupture is however difficult to predict due to the heterogenous composition of the plaque, unknown material properties, and the stochastic nature of the event. Here, we aim to create tissue engineered human fibrous cap models with a variable but controllable collagen composition, suitable for mechanical testing, to scrutinize the reciprocal relationships between composition and mechanical properties. Myofibroblasts were cultured in 1 × 1.5 cm-sized fibrin-based constrained gels for 21 days according to established (dynamic) culture protocols (i.e. static, intermittent or continuous loading) to vary collagen composition (e.g. amount, type and organization). At day 7, a soft 2 mm ∅ fibrin inclusion was introduced in the centre of each tissue to mimic the soft lipid core, simulating the heterogeneity of a plaque. Results demonstrate reproducible collagenous tissues, that mimic the bulk mechanical properties of human caps and vary in collagen composition due to the presence of a successfully integrated soft inclusion and the culture protocol applied. The models can be deployed to assess tissue mechanics, evolution and failure of fibrous caps or complex heterogeneous tissues in general.
- 1 December 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 129, 110816
A review on the association of thrombus composition with mechanical and radiological imaging characteristics in acute ischemic stroke
- 1 December 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 129, 110816
A review on the association of thrombus composition with mechanical and radiological imaging characteristics in acute ischemic stroke
- Open Access
- 22 August 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (8) , 1513
IVUS Longitudinal and Axial Registration for Atherosclerosis Progression Evaluation
Intravascular ultrasound (IVUS) imaging offers accurate cross-sectional vessel information. To this end, registering temporal IVUS pullbacks acquired at two time points can assist the clinicians to accurately assess pathophysiological changes in the vessels, disease progression and the effect of the treatment intervention. In this paper, we present a novel two-stage registration framework for aligning pairs of longitudinal and axial IVUS pullbacks. Initially, we use a Dynamic Time Warping (DTW)-based algorithm to align the pullbacks in a temporal fashion. Subsequently, an intensity-based registration method, that utilizes a variant of the Harmony Search optimizer to register each matched pair of the pullbacks by maximizing their Mutual Information, is applied. The presented method is fully automated and only required two single global image-based measurements, unlike other methods that require extraction of morphology-based features. The data used includes 42 synthetically generated pullback pairs, achieving an alignment error of frames per pullback, a rotation error and a translation error of mm. In addition, it was also tested on 11 baseline and follow-up, and 10 baseline and post-stent deployment real IVUS pullback pairs from two clinical centres, achieving an alignment error of for the longitudinal registration, and a distance and a rotational error of mm and , respectively, for the axial registration. Although the performance of the proposed method does not match that of the state-of-the-art, our method relies on computationally lighter steps for its computations, which is crucial in real-time applications. On the other hand, the proposed method performs even or better that the state-of-the-art when considering the axial registration. The results indicate that the proposed method can support clinical decision making and diagnosis based on sequential imaging examinations.- 22 August 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (8) , 1513
Open AccessIVUS Longitudinal and Axial Registration for Atherosclerosis Progression Evaluation
Intravascular ultrasound (IVUS) imaging offers accurate cross-sectional vessel information. To this end, registering temporal IVUS pullbacks acquired at two time points can assist the clinicians to accurately assess pathophysiological changes in the vessels, disease progression and the effect of the treatment intervention. In this paper, we present a novel two-stage registration framework for aligning pairs of longitudinal and axial IVUS pullbacks. Initially, we use a Dynamic Time Warping (DTW)-based algorithm to align the pullbacks in a temporal fashion. Subsequently, an intensity-based registration method, that utilizes a variant of the Harmony Search optimizer to register each matched pair of the pullbacks by maximizing their Mutual Information, is applied. The presented method is fully automated and only required two single global image-based measurements, unlike other methods that require extraction of morphology-based features. The data used includes 42 synthetically generated pullback pairs, achieving an alignment error of frames per pullback, a rotation error and a translation error of mm. In addition, it was also tested on 11 baseline and follow-up, and 10 baseline and post-stent deployment real IVUS pullback pairs from two clinical centres, achieving an alignment error of for the longitudinal registration, and a distance and a rotational error of mm and , respectively, for the axial registration. Although the performance of the proposed method does not match that of the state-of-the-art, our method relies on computationally lighter steps for its computations, which is crucial in real-time applications. On the other hand, the proposed method performs even or better that the state-of-the-art when considering the axial registration. The results indicate that the proposed method can support clinical decision making and diagnosis based on sequential imaging examinations. - Open Access
- 12 August 2021
- Published by Springer Nature in Research Square
Tissue-engineered Collagenous Fibrous Cap Models to Systematically Elucidate Atherosclerotic Plaque Rupture.
A significant amount of vascular thrombotic events is associated with rupture of the fibrous cap that overlie atherosclerotic plaques. Cap rupture is however difficult to predict due to the heterogenous composition of the plaque, unknown material properties, and the stochastic nature of the event. Here, we aim to create tissue engineered human fibrous cap models with a variable but controllable collagen composition, suitable for mechanical testing, to scrutinize the reciprocal relationships between composition and mechanical properties. Myofibroblasts were cultured in 1 x 1.5 cm-sized fibrin-based constrained gels for 21 days according to established (dynamic) culture protocols (i.e. static, intermittent or continuous loading) to vary collagen composition (e.g. amount, type and organization). At day 7, a soft 2 mm ∅ fibrin inclusion was introduced in the centre of each tissue to mimic the soft lipid core, simulating the heterogeneity of a plaque. Results demonstrate reproducible collagenous tissues, that mimic the bulk mechanical properties of human caps and vary in collagen composition due to the presence of an successfully integrated soft inclusion and the culture protocol applied. The models can be deployed to assess tissue mechanics, evolution and failure of fibrous caps or complex heterogeneous tissues in general.
- 12 August 2021
- Published by Springer Nature in Research Square
Open AccessTissue-engineered Collagenous Fibrous Cap Models to Systematically Elucidate Atherosclerotic Plaque Rupture.
A significant amount of vascular thrombotic events is associated with rupture of the fibrous cap that overlie atherosclerotic plaques. Cap rupture is however difficult to predict due to the heterogenous composition of the plaque, unknown material properties, and the stochastic nature of the event. Here, we aim to create tissue engineered human fibrous cap models with a variable but controllable collagen composition, suitable for mechanical testing, to scrutinize the reciprocal relationships between composition and mechanical properties. Myofibroblasts were cultured in 1 x 1.5 cm-sized fibrin-based constrained gels for 21 days according to established (dynamic) culture protocols (i.e. static, intermittent or continuous loading) to vary collagen composition (e.g. amount, type and organization). At day 7, a soft 2 mm ∅ fibrin inclusion was introduced in the centre of each tissue to mimic the soft lipid core, simulating the heterogeneity of a plaque. Results demonstrate reproducible collagenous tissues, that mimic the bulk mechanical properties of human caps and vary in collagen composition due to the presence of an successfully integrated soft inclusion and the culture protocol applied. The models can be deployed to assess tissue mechanics, evolution and failure of fibrous caps or complex heterogeneous tissues in general.
- Top Cited PapersOpen Access
- 1 August 2021
- Published by Wolters Kluwer Health in Stroke
- Vol. 52 (8) , 2510-2517
Mechanical Characterization of Thrombi Retrieved With Endovascular Thrombectomy in Patients With Acute Ischemic Stroke
Background and Purpose: Mechanical properties of thromboemboli play an important role in the efficacy of endovascular thrombectomy (EVT) for acute ischemic stroke. However, very limited data on mechanical properties of human stroke thrombi are available. We aimed to mechanically characterize thrombi retrieved with EVT, and to assess the relationship between thrombus composition and thrombus stiffness. Methods: Forty-one thrombi from 19 patients with acute stroke who underwent EVT between July and October 2019 were mechanically analyzed, directly after EVT. We performed unconfined compression experiments and determined tangent modulus at 75% strain (E t75 ) as a measure for thrombus stiffness. Thrombi were histologically analyzed for fibrin/platelets, erythrocytes, leukocytes, and platelets, and we assessed the relationship between histological components and E t75 with univariable and multivariable linear mixed regression. Results: Median E t75 was 560 (interquartile range, 393–1161) kPa. In the multivariable analysis, fibrin/platelets were associated with increased E t75 (aβ, 9 [95% CI, 5 to 13]) kPa, erythrocytes were associated with decreased E t75% (aβ, −9 [95% CI, −5 to −13]) kPa. We found no association between leukocytes and E t75 . High platelet values were strongly associated with increased E t75 (aβ, 56 [95% CI, 38–73]). Conclusions: Fibrin/platelet content of thrombi retrieved with EVT for acute ischemic stroke is strongly associated with increased thrombus stiffness. For thrombi with high platelet values, there was a very strong relationship with thrombus stiffness. Our data provide a basis for future research on the development of next-generation EVT devices tailored to thrombus composition.
- 1 August 2021
- Published by Wolters Kluwer Health in Stroke
- Vol. 52 (8) , 2510-2517
Top Cited PapersOpen AccessMechanical Characterization of Thrombi Retrieved With Endovascular Thrombectomy in Patients With Acute Ischemic Stroke
Background and Purpose: Mechanical properties of thromboemboli play an important role in the efficacy of endovascular thrombectomy (EVT) for acute ischemic stroke. However, very limited data on mechanical properties of human stroke thrombi are available. We aimed to mechanically characterize thrombi retrieved with EVT, and to assess the relationship between thrombus composition and thrombus stiffness. Methods: Forty-one thrombi from 19 patients with acute stroke who underwent EVT between July and October 2019 were mechanically analyzed, directly after EVT. We performed unconfined compression experiments and determined tangent modulus at 75% strain (E t75 ) as a measure for thrombus stiffness. Thrombi were histologically analyzed for fibrin/platelets, erythrocytes, leukocytes, and platelets, and we assessed the relationship between histological components and E t75 with univariable and multivariable linear mixed regression. Results: Median E t75 was 560 (interquartile range, 393–1161) kPa. In the multivariable analysis, fibrin/platelets were associated with increased E t75 (aβ, 9 [95% CI, 5 to 13]) kPa, erythrocytes were associated with decreased E t75% (aβ, −9 [95% CI, −5 to −13]) kPa. We found no association between leukocytes and E t75 . High platelet values were strongly associated with increased E t75 (aβ, 56 [95% CI, 38–73]). Conclusions: Fibrin/platelet content of thrombi retrieved with EVT for acute ischemic stroke is strongly associated with increased thrombus stiffness. For thrombi with high platelet values, there was a very strong relationship with thrombus stiffness. Our data provide a basis for future research on the development of next-generation EVT devices tailored to thrombus composition.
- Open Access
Tissue-engineered collagenous fibrous cap models to systematically elucidate atherosclerotic plaque rupture
A significant amount of vascular thrombotic events is associated with rupture of the fibrous cap that overlie atherosclerotic plaques. Cap rupture is however difficult to predict due to the heterogenous composition of the plaque, unknown material properties, and the stochastic nature of the event. Here, we aim to create tissue engineered human fibrous cap models with a variable but controllable collagen composition, suitable for mechanical testing, to scrutinize the reciprocal relationships between composition and mechanical properties. Myofibroblasts were cultured in 1 × 1.5 cm-sized fibrin-based constrained gels for 21 days according to established (dynamic) culture protocols (i.e. static, intermittent or continuous loading) to vary collagen composition (e.g. amount, type and organization). At day 7, a soft 2 mm Ø fibrin inclusion was introduced in the centre of each tissue to mimic the soft lipid core, simulating the heterogeneity of a plaque. Results demonstrate reproducible collagenous tissues, that mimic the bulk mechanical properties of human caps and vary in collagen composition due to the presence of an successfully integrated soft inclusion and the culture protocol applied. The models can be deployed to assess tissue mechanics, evolution and failure of fibrous caps or complex heterogeneous tissues in general.
Open AccessTissue-engineered collagenous fibrous cap models to systematically elucidate atherosclerotic plaque rupture
A significant amount of vascular thrombotic events is associated with rupture of the fibrous cap that overlie atherosclerotic plaques. Cap rupture is however difficult to predict due to the heterogenous composition of the plaque, unknown material properties, and the stochastic nature of the event. Here, we aim to create tissue engineered human fibrous cap models with a variable but controllable collagen composition, suitable for mechanical testing, to scrutinize the reciprocal relationships between composition and mechanical properties. Myofibroblasts were cultured in 1 × 1.5 cm-sized fibrin-based constrained gels for 21 days according to established (dynamic) culture protocols (i.e. static, intermittent or continuous loading) to vary collagen composition (e.g. amount, type and organization). At day 7, a soft 2 mm Ø fibrin inclusion was introduced in the centre of each tissue to mimic the soft lipid core, simulating the heterogeneity of a plaque. Results demonstrate reproducible collagenous tissues, that mimic the bulk mechanical properties of human caps and vary in collagen composition due to the presence of an successfully integrated soft inclusion and the culture protocol applied. The models can be deployed to assess tissue mechanics, evolution and failure of fibrous caps or complex heterogeneous tissues in general.