  • Strut Thickness and Species‐Specific Healing Are Key Considerations in Developing Zinc‐Based Biodegradable Arterial Stents

    by Lea M. Morath, Shebeer A. Rahim, Cole A. Baker, Shobana Santhanam, Deirdre E. J. Anderson, Alex M. LaMere, Lindy G. Oujiri, Greet Kerckhofs, Grzegorz Pyka, Monica T. Hinds, et al.

    Zinc‐based biodegradable stents offer a promising solution for temporary vascular support, aiding in vessel healing while reducing long‐term complications such as thrombosis and restenosis. This study examined three zinc‐based alloys: AMZ (Zn–4.0Ag–0.6Mn–0.1Zr), ACMZ (Zn–3.5Ag–0.5Cu–0.7Mn–0.1Zr), and CMM (Zn–1.0Cu–0.6Mn–0.05 Mg), all featuring reduced wire diameters of 0.12 mm. The focus was on their microstructure, mechanical performance, thrombogenicity, and in vivo biocompatibility. The alloys were processed through cold drawing and heat treatment, resulting in ultra‐fine‐grained structures measuring less than 1 μm. Energy dispersive spectroscopy (EDS) and x‐ray diffraction (XRD) analyses confirmed the presence of strengthening intermetallic phases (AgZn 3 , CuZn 4 , and MnZn 13 ), while a uniform elemental distribution indicated solid solution strengthening. Heat treatment enhanced ductility, especially in the AMZ and ACMZ alloys, without compromising tensile strength. In vitro hemocompatibility assays showed low thrombogenicity for these alloys, with lower fibrin and FXIIa generation compared to clinical control materials. Ex vivo assessments of platelet and fibrin attachment revealed similar results to those observed with pure zinc controls. In vivo implantation of the stent materials into the abdominal aortas of mice and rats produced distinct species‐specific immune responses. Mice exhibited significant inflammation, extracellular matrix degradation, and necrosis, raising potential concerns about their biocompatibility in this model. In contrast, implants in rats resulted in only mild inflammation and limited neointimal growth, with no signs of necrosis. This suggests a more favorable and controlled healing response in rats. Morphometric analysis of Verhoeff–Van Gieson‐stained cross‐sections indicated that the 0.12 mm wires produced significantly less neointimal growth compared to previously tested 0.25 mm implants in rats, highlighting the advantages of smaller implant dimensions. Overall, these findings support the use of refined zinc‐based alloys with smaller struts for next‐generation biodegradable stents. However, the inflammatory response observed in mice emphasizes the necessity for careful selection of models in preclinical testing.

  • Open Access

    Micropatterning transcriptionally and phenotypically reprograms endothelial cells

    by Paula Josic Dominovic, Meghan E. Fallon, Jiaqing Pang, Theodora T. Alese, Hillary H. Le, Deirdre E.J. Anderson, Owen J.T. McCarty, Anthony P. Barnes, Monica T. Hinds

  • Open Access

    Thrombogenic characterization of alloyed and surface-modified magnesium bioresorbable metals for cardiovascular device applications

    by Cole A. Baker, Jennifer J. Johnson, Monica T. Hinds, Deirdre E.J. Anderson


  • Effects of in utero exposure to Δ-9-tetrahydrocannabinol on cardiac extracellular matrix expression and vascular transcriptome in rhesus macaques

    by Hillary H. Le, Lyndsey E. Shorey-Kendrick, Monica T. Hinds, Owen J. T. McCarty, Jamie O. Lo, Deirdre E. J. Anderson

    Prenatal cannabis use is increasing and despite the public health relevance, there is limited safety data regarding its impact on offspring cardiovascular health outcomes. We used a translational, nonhuman primate model of daily edible Δ-9-tetrahydrocannabinol (THC) consumption during pregnancy to assess its effects on the fetal cardiovascular system. THC-exposed fetal vascular tissues displayed upregulation of genes involved in cellular metabolism and inflammation, suggesting that prenatal THC exposure may impact fetal vascular tissues.


  • Open Access

    Thrombogenicity of biodegradable metals

    by D.E.J. Anderson, H.H. Le, H. Vu, J. Johnson, J.E. Aslan, J. Goldman, M.T. Hinds

    Biodegradable metals offer a promising means to ameliorate many of the long-term risks associated with vascular devices made of conventional biostable stent metals. While numerous biodegradable metal alloys have been developed and characterized in animal models, knowledge of their blood reactivity and thrombogenicity remains unknown. Metal hemocompatibility is particularly valuable because current generation drug-eluting stents pose a significant long-term thrombosis risk. In this study, four pure metals, widely used as degradable base materials (Fe, Zn, Mg, and Mo), and three alloys commonly used in cardiovascular devices [NiTi, CoCr, and stainless steel (SS)] were evaluated. This work examined how each of these metals activate platelets, coagulation factors, and inflammation using in vitro hemocompatibility assays and a clinically relevant ex vivo non-human primate arteriovenous shunt model. Testing found that while all metals promoted a downstream activation of platelets and coagulation in flowing whole blood, platelet and fibrin attachment to Mg was markedly reduced. Additionally, Fe and Mo trended toward higher platelet attachment and contact pathway activation. Overall, the results suggest that Mg may delay clot initiation, but not eliminate clot formation, indicating the importance of understanding thrombosis in Mg alloys that are currently being developed for clinical use as biodegradable stents.


  • Pharmacologic targeting of coagulation factors XII and XI by monoclonal antibodies reduces thrombosis in nitinol stents under flow

    by Novella M. Keeling, Michael Wallisch, Jennifer Johnson, Hillary H. Le, Helen H. Vu, Kelley R. Jordan, Cristina Puy, Erik I. Tucker, Khanh P. Nguyen, Owen J.T. McCarty, et al.


  • Open Access

    Hemocompatibility of micropatterned biomaterial surfaces is dependent on topographical feature size

    by Meghan E. Fallon, Hillary H. Le, Novella M. Bates, Yuan Yao, Evelyn K.F. Yim, Monica T. Hinds, Deirdre E.J. Anderson

    Small-diameter synthetic vascular grafts that have improved hemocompatibility and patency remain an unmet clinical need due to thrombosis. A surface modification that has potential to attenuate these failure mechanisms while promoting an endothelial layer is the micropatterning of luminal surfaces. Anisotropic features have been shown to downregulate smooth muscle cell proliferation, direct endothelial migration, and attenuate platelet adhesion and activation. However, the effect of micropatterning feature size and orientation relative to whole blood flow has yet to be investigated within a systematic study. In this work, hemocompatibility of micropattern grating sizes of 2, 5, and 10 µm were investigated. The thrombogenicity of the micropattern surface modifications were characterized by quantifying FXIIa activity, fibrin formation, and static platelet adhesion in vitro. Additionally, dynamic platelet attachment and end-point fibrin formation were quantified using an established, flowing whole blood ex vivo non-human primate shunt model without antiplatelet or anticoagulant therapies. We observed a higher trend in platelet attachment and significantly increased fibrin formation for larger features. We then investigated the orientation of 2 µm gratings relative to whole blood flow and found no significant differences between the various orientations for platelet attachment, rate of linear platelet attachment, or end-point fibrin formation. MicroCT analysis of micropatterned grafts was utilized to quantify luminal patency. This work is a significant step in the development of novel synthetic biomaterials with improved understanding of hemocompatibility for use in cardiovascular applications.


  • Open Access

    Bioconjugation of a Collagen-Mimicking Peptide Onto Poly(vinyl alcohol) Encourages Endothelialization While Minimizing Thrombosis

    by Novella M. Bates, Heather E. Heidenreich, Meghan E. Fallon, Yuan Yao, Evelyn K. F. Yim, Monica T. Hinds, Deirdre E. J. Anderson

    Poly(vinyl alcohol) hydrogel, PVA, is a suitable material for small-diameter vascular grafting. However, the bioinert properties of the material do not allow for in situ endothelialization, which is needed to combat common graft failure mechanisms, such as intimal hyperplasia and thrombosis. In this work, the surface of planar and tubular PVA was covalently modified with a collagen-mimicking peptide, GFPGER. The surface of modified PVA was characterized by measuring contact angle and x-ray photoelectron spectroscopy. Endothelial cell attachment to GFPGER-modified PVA was quantified and qualitatively examined using immunohistochemical staining. Then, in vitro hemocompatibility testing was performed by quantifying platelet attachment, coagulation factor XII activation, and initiation of fibrin formation. Finally, an established ex vivo, non-human primate model was employed to examine platelet attachment and fibrin formation under non-anticoagulated, whole blood flow conditions. GFPGER-modified PVA supported increased EC attachment. In vitro initiation of fibrin formation on the modified material was significantly delayed. Ex vivo thrombosis assessment showed a reduction in platelet attachment and fibrin formation on GFPGER-modified PVA. Overall, GFPGER-modified PVA encouraged cell attachment while maintaining the material’s hemocompatibility. This work is a significant step toward the development and characterization of a modified-hydrogel surface to improve endothelialization while reducing platelet attachment.


  • Effect of Ethylene Oxide Sterilization on Polyvinyl Alcohol Hydrogel Compared with Gamma Radiation

    by Grace Pohan, Sabrina Mattiassi, Yuan Yao, Aung Moe Zaw, Deirdre E.J. Anderson, Marie F.A. Cutiongco, Monica T. Hinds, Evelyn K.F. Yim

    This study investigated the effects of terminal sterilization of polyvinyl alcohol (PVA) biomaterials using clinically translatable techniques, specifically ethylene oxide (EtO) and gamma (γ) irradiation. While a few studies have reported the possibility of sterilizing PVA with γ-radiation, the use of EtO sterilization of PVA requires additional study. PVA solutions were chemically crosslinked with trisodium trimetaphosphate and sodium hydroxide. The three experimental groups included untreated control, EtO, and γ-irradiation, which were tested for the degree of swelling and water content, and mechanical properties such as radial compliance, longitudinal tensile, minimum bend radius, burst pressure, and suture retention strength. In addition, samples were characterized with scanning electron microscopy, differential scanning calorimetry, X-ray photoelectron spectroscopy, and water contact angle measurements. Cell attachment was assessed using the endothelial cell line EA.hy926, and the sterilized PVA cytotoxicity was studied with a live/dead stain. Platelet and fibrin accumulation was measured using an ex vivo shunt baboon model. Finally, the immune responses of PVA implants were analyzed after a 21-day subcutaneous implantation in rats and a 30-day implantation in baboon. EtO sterilization reduced the PVA graft wall thickness, its degree of swelling, and water content compared with both γ-irradiated and untreated PVA. Moreover, EtO sterilization significantly reduced the radial compliance and increased Young's modulus. EtO did not change PVA hydrophilicity, while γ-irradiation increased the water contact angle of the PVA. Consequently, endothelial cell attachment on the EtO-sterilized PVA showed similar results to the untreated PVA, while cell attachment significantly improved on the γ-irradiated PVA. When exposing the PVA grafts to circulating whole blood, fibrin accumulation of EtO-sterilized PVA was found to be significantly lower than γ-irradiated PVA. The immune responses of γ-irradiated PVA, EtO-treated PVA, and untreated PVA were compared. Implanted EtO-treated PVA showed the least MAC387 reaction. The terminal sterilization methods in this study changed PVA hydrogel properties; nevertheless, based on the characterizations performed, both sterilization methods were suitable for sterilizing PVA. We concluded that EtO can be used as an alternative method to sterilize PVA hydrogel material. Impact statement: Polyvinyl alcohol (PVA) hydrogels have been used for a variety of tissue replacements, including neural, cardiac, meniscal, cartilage, muscle, pancreatic, and ocular applications. In addition, PVA can be made into a tubular shape and used as a small-diameter vascular graft. Ethylene oxide (EtO) is one of the Food and Drug Administration-approved methods for sterilization, but its effect on PVA has not been studied extensively. The outcome of this study provides the effects of EtO and γ-irradiation of PVA grafts on both the material properties and the in vivo responses, particularly for vascular applications. Knowledge of these effects may ultimately improve the success rate of PVA vascular grafts.


  • Open Access

    Quantifying Physical Thrombus Characteristics on Cardiovascular Biomaterials Using MicroCT

    by Avi Gupta, Claire M. Johnston, Monica T. Hinds, Deirdre E. J. Anderson

    Hemocompatibility is a critical consideration when designing cardiovascular devices. Methods of assessing hemocompatibility range from in vitro protein adsorption and static platelet attachment to in vivo implantation. A standard preclinical assessment of biomaterial hemocompatibility is ex vivo quantification of thrombosis in a chronic arteriovenous shunt. This technique utilizes flowing blood and quantifies platelet accumulation and fibrin deposition. However, the physical parameters of the thrombus have remained unknown. This study presents the development of a novel method to quantify the 3D physical properties of the thrombus on different biomaterials: expanded polytetrafluoroethylene and a preclinical hydrogel, poly(vinyl alcohol). Tubes of 4–5 mm inner diameter were exposed to non-anticoagulated blood flow for 1 hour and fixed. Due to differences in biomaterial water absorption properties, unique methods, requiring either the thrombus or the lumen to be radiopaque, were developed to quantify average thrombus volume within a graft. The samples were imaged using X-ray microcomputed tomography (microCT). The methodologies were strongly and significantly correlated to caliper-measured graft dimensions (R2 = 0.994, p < 0.0001). The physical characteristics of the thrombi were well correlated to platelet and fibrin deposition. MicroCT scanning and advanced image analyses were successfully applied to quantitatively measure 3D physical parameters of thrombi on cardiovascular biomaterials under flow.