Dorothy J. Miller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dorothy J. Miller has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
J. Lind
Lawrence Livermore National Laboratory
3 shared publications- Michael A. Homel
University of Utah
3 shared publications - Ryan S. Crum
Lawrence Livermore National Laboratory
3 shared publications D. E. Eakins
University of Oxford
2 shared publicationsD. J. Chapman
University of Oxford
2 shared publicationsE. B. Herbold
Lawrence Livermore National Laboratory
2 shared publications
Latest Publications
- Open Access
- 1 March 2019
- Published by Springer Nature in Journal of Dynamic Behavior of Materials
- Vol. 5 (2) , 194
Correction to: Hugoniot Measurements Utilizing In Situ Synchrotron X-ray Radiation
- 1 March 2019
- Published by Springer Nature in Journal of Dynamic Behavior of Materials
- Vol. 5 (2) , 194
Open AccessCorrection to: Hugoniot Measurements Utilizing In Situ Synchrotron X-ray Radiation
- 6 February 2019
- Published by Springer Nature in Journal of Dynamic Behavior of Materials
- Vol. 5 (1) , 93-104
Hugoniot Measurements Utilizing In Situ Synchrotron X-ray Radiation
- 6 February 2019
- Published by Springer Nature in Journal of Dynamic Behavior of Materials
- Vol. 5 (1) , 93-104
Hugoniot Measurements Utilizing In Situ Synchrotron X-ray Radiation
- 11 January 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 125 (2) , 025902
In situ X-ray imaging of heterogeneity in dynamic compaction of granular media
Dynamic compaction of granular materials is a complex process, wherein the material response at the continuum scale arises from fracture, comminution, and fragment flow at the grain scale. Granular materials have heterogeneity due to variation in grain properties as well as variation in local packing density and structure. These heterogeneities may affect the dynamic compaction response, producing a structured and time-varying compaction front. The methodology used to characterize the shock behavior in solid materials may be inappropriate for granular materials because of this unsteady behavior and interactions between the granular material and measurement surfaces. To observe the compaction front heterogeneity, in situ x-ray imaging of granular compaction is conducted at a scale between the grain- and continuum scales. To allow for sufficient x-ray transmission, a thin sample geometry is used, for which boundary affects may result in a significantly different load path than would occur in a 1-D compaction configuration. Numerical simulations of the experimental geometry support the analysis of the results so that the feature of the compaction front can be distinguished from artifacts of the experimental configuration. The results suggest that compaction front heterogeneity may have structure with a length scale of tens of particle diameters and demonstrate that finite grain size can inhibit the formation of shear-induced features that would arise in a homogenized representation of the same material.
- 11 January 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 125 (2) , 025902
In situ X-ray imaging of heterogeneity in dynamic compaction of granular media
Dynamic compaction of granular materials is a complex process, wherein the material response at the continuum scale arises from fracture, comminution, and fragment flow at the grain scale. Granular materials have heterogeneity due to variation in grain properties as well as variation in local packing density and structure. These heterogeneities may affect the dynamic compaction response, producing a structured and time-varying compaction front. The methodology used to characterize the shock behavior in solid materials may be inappropriate for granular materials because of this unsteady behavior and interactions between the granular material and measurement surfaces. To observe the compaction front heterogeneity, in situ x-ray imaging of granular compaction is conducted at a scale between the grain- and continuum scales. To allow for sufficient x-ray transmission, a thin sample geometry is used, for which boundary affects may result in a significantly different load path than would occur in a 1-D compaction configuration. Numerical simulations of the experimental geometry support the analysis of the results so that the feature of the compaction front can be distinguished from artifacts of the experimental configuration. The results suggest that compaction front heterogeneity may have structure with a length scale of tens of particle diameters and demonstrate that finite grain size can inhibit the formation of shear-induced features that would arise in a homogenized representation of the same material.
- Open Access
- 12 December 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (36) , 9868-9875
Detection of uranyl fluoride and sand surface contamination on metal substrates by hand-held laser-induced breakdown spectroscopy
A hand-held device for laser-induced breakdown spectroscopy has been investigated for the determination of uranyl fluoride surface contamination. This research demonstrates the ability to successfully detect uranium on surfaces when using a low resolving power (λ/Δλ=4000) spectrograph, with a 5 mJ energy per 1 ns pulsed laser radiation, available as a commercially packaged hand-held system. Sand/uranyl fluoride mixtures are prepared to simulate residue likely encountered during decontamination efforts at facilities that handle uranium hexafluoride. Detection limits are described for four uranium lines with one revealing the capability to detect uranium at a level of 250 parts per million. Advantages of the studied compact device include that location specific information can be obtained on-site to augment contamination identification.
- 12 December 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (36) , 9868-9875
Open AccessDetection of uranyl fluoride and sand surface contamination on metal substrates by hand-held laser-induced breakdown spectroscopy
A hand-held device for laser-induced breakdown spectroscopy has been investigated for the determination of uranyl fluoride surface contamination. This research demonstrates the ability to successfully detect uranium on surfaces when using a low resolving power (λ/Δλ=4000) spectrograph, with a 5 mJ energy per 1 ns pulsed laser radiation, available as a commercially packaged hand-held system. Sand/uranyl fluoride mixtures are prepared to simulate residue likely encountered during decontamination efforts at facilities that handle uranium hexafluoride. Detection limits are described for four uranium lines with one revealing the capability to detect uranium at a level of 250 parts per million. Advantages of the studied compact device include that location specific information can be obtained on-site to augment contamination identification.