Daniel. C. Whittingslow

Daniel. C. Whittingslow

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daniel. C. Whittingslow has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Rural Hospital Designation Is Associated With Increased Complications and Resource Utilization After Primary Total Hip Arthroplasty: A Matched Case-Control Study

    by Matthew S. Broggi, Philip O. Oladeji, Daniel C. Whittingslow, Jacob M. Wilson, Thomas L. Bradbury, Greg A. Erens, George N. Guild


  • Detection of Meniscal Tear Effects on Tibial Vibration Using Passive Knee Sound Measurements

    by Goktug C. Ozmen, Mohsen Safaei, Beren Semiz, Daniel C. Whittingslow, Jennifer L. Hunnicutt, Sampath Prahalad, Regina Hash, John W. Xerogeanes, Omer T. Inan

    Objective: To evaluate whether non-invasive knee sound measurements can provide information related to the underlying structural changes in the knee following meniscal tear. These changes are explained using an equivalent vibrational model of the knee-tibia structure. Methods: First, we formed an analytical model by modeling the tibia as a cantilever beam with the fixed end being the knee. The knee end was supported by three lumped components with features corresponding with tibial stiffnesses, and meniscal damping effect. Second, we recorded knee sounds from 46 healthy legs and 9 legs with acute meniscal tears (n = 34 subjects). We developed an acoustic event (“click”) detection algorithm to find patterns in the recordings, and used the instrumental variable continuous-time transfer function estimation algorithm to model them. Results: The knee sound measurements yielded consistently lower fundamental mode decay rate in legs with meniscal tears (16 ±13 s - 1 ) compared to healthy legs (182 ±128 s - 1 ), p <; 0.05. When we performed an intra-subject analysis of the injured versus contralateral legs for the 9 subjects with meniscus tears, we observed significantly lower natural frequency and damping ratio (first mode results for healthy: f n1 = 115 ±44 Hz, ξ 1 = 0.098 ±0.022, injured: f n1 = 67 ±10 Hz, ξ 1 = 0.036 ±0.029) for the first three vibration modes (p <; 0.05). These results agreed with the theoretical expectations gleaned from the vibrational model. Significance: This combined analytical and experimental method improves our understanding of how vibrations can describe the underlying structural changes in the knee following meniscal tear, and supports their use as a tool for future efforts in non-invasively diagnosing meniscal tear injuries.


  • Acoustic Emissions From Loaded and Unloaded Knees to Assess Joint Health in Patients With Juvenile Idiopathic Arthritis

    by Sevda Gharehbaghi, Daniel C. Whittingslow, Lori A. Ponder, Sampath Prahalad, Omer T. Inan

    Objective: We studied and compared joint acoustical emissions (JAEs) in loaded and unloaded knees as digital biomarkers for evaluating knee health status during the course of treatment in patients with juvenile idiopathic arthritis (JIA). Methods: JAEs were recorded from 38 participants, performing 10 repetitions of unloaded flexion/extension (FE) and loaded squat exercises. A novel algorithm was developed to detect and exclude rubbing noise and loose microphone artifacts from the signals, and then 72 features were extracted. These features were down-selected based on different criteria to train three logistic regression classifiers. The classifiers were trained with healthy and pre-treatment data and were used to predict the knee health scores of post-treatment data for the same patients with JIA who had a follow-up recording. This knee health score represents the probability of having JIA in a subject (0 for healthy and 1 for arthritis). Results: Post-treatment knee health scores were lower than pre-treatment scores, agreeing with the clinical records of successful treatment. Regarding loaded versus unloaded knee scores, the squats achieved a higher score on average compared to FEs. Conclusion: In healthy subjects with smooth cartilage, the knee scores of squats and FEs were similar indicating that vibrations from the friction of articulating surfaces do not significantly change by the joint load. However, in subjects with JIA, the scores of squats were higher than the scores of FEs, revealing that these two exercises contain different, possibly clinically relevant, information that could be used to further improve this novel assessment modality in JIA.


  • An Interpretable Experimental Data Augmentation Method to Improve Knee Health Classification Using Joint Acoustic Emissions

    by Goktug C. Ozmen, Asim H. Gazi, Sevda Gharehbaghi, Kristine L. Richardson, Mohsen Safaei, Daniel C. Whittingslow, Sampath Prahalad, Jennifer L. Hunnicutt, John W. Xerogeanes, Teresa K. Snow, et al.

    The characteristics of joint acoustic emissions (JAEs) measured from the knee have been shown to contain information regarding underlying joint health. Researchers have developed methods to process JAE measurements and combined them with machine learning algorithms for knee injury diagnosis. While these methods are based on JAEs measured in controlled settings, we anticipate that JAE measurements could enable accessible and affordable diagnosis of acute knee injuries also in field-deployable settings. However, in such settings, the noise and interference would be greater than in sterile, laboratory environments, which could decrease the performance of existing knee health classification methods using JAEs. To address the need for an objective noise and interference detection method for JAE measurements as a step towards field-deployable settings, we propose a novel experimental data augmentation method to locate and then, remove the corrupted parts of JAEs measured in clinical settings. In the clinic, we recruited 30 participants, and collected data from both knees, totaling 60 knees (36 healthy and 24 injured knees) to be used subsequently for knee health classification. We also recruited 10 healthy participants to collect artifact and joint sounds (JS) click templates, which are audible, short duration and high amplitude JAEs from the knee. Spectral and temporal features were extracted, and clinical data was augmented in five-dimensional subspace by fusing the existing clinical dataset into experimentally collected templates. Then knee scores were calculated by training and testing a linear soft classifier utilizing leave-one-subject-out cross-validation (LOSO-CV). The area under the curve (AUC) was 0.76 for baseline performance without any window removal with a logistic regression classifier (sensitivity = 0.75, specificity = 0.78). We obtained an AUC of 0.86 with the proposed algorithm (sensitivity = 0.80, specificity = 0.89), and on average, 95% of all clinical data was used to achieve this performance. The proposed algorithm improved knee health classification performance by the added information through identification and collection of common artifact sources in JAE measurements. This method when combined with wearable systems could provide clinically relevant supplementary information for both underserved populations and individuals requiring point-of-injury diagnosis in field-deployable settings.


  • Robust Method for Mid-Activity Tracking and Evaluation of Ankle Health Post-Injury

    by Samer Mabrouk, Daniel Whittingslow, Omer T. Inan

    Objective: To present a robust methodology for evaluating ankle health during ambulation using a wearable device. Methods: We developed a novel data capture system that leverages changes within the ankle during ambulation for real-time tracking of bioimpedance. The novel analysis compares the range of reactance at 5 kHz to the range of reactance at 100 kHz; which removes the technique's previous reliance on a known baseline. To aid in interpretation of the measurements, we developed a quantitative simulation model based on a literature review of the effects on joint bioimpedance of variations in edematous fluid volume, muscle fiber tears, and blood flow changes. Results: The results of the simulation predicted a significant difference in the ratio of the range of the reactance from 5 kHz to 100 kHz between the healthy and injured ankles. These results were validated in 15 subjects - with 11 healthy ankles and 7 injured ankles measured. The injured subjects had lateral ankle sprains 2-4 weeks prior to the measurement. The analysis technique differentiated between the healthy and the injured population (p<<0.01), and a correlation (R = 0.8) with a static protocol previously validated for its sensitivity to edema. Conclusion: The technology presented can detect variations in ankle edema and structural integrity of ankles, and thus could provide valuable feedback to clinicians and patients during the rehabilitation of an ankle injury. Significance: This technology could lead to better-informed decision making regarding a patient's readiness to return to activity and / or tailoring rehabilitation activities to an individual's changing needs.


  • Open Access

    Vibration Stimulation as a Non-Invasive Approach to Monitor the Severity of Meniscus Tears

    by Mohsen Safaei, Nicholas B. Bolus, Daniel C. Whittingslow, Hyeon-Ki Jeong, Alper Erturk, Omer T. Inan

    Musculoskeletal disorders and injuries are one of the most prevalent medical conditions across age groups. Due to a high load-bearing function, the knee is particularly susceptible to injuries such as meniscus tears. Imaging techniques are commonly used to assess meniscus injuries, though this approach suffers from limitations including high cost, need for skilled personnel, and confinement to laboratory or clinical settings. Vibration-based structural monitoring methods in the form of acoustic emission analysis and vibration stimulation have the potential to address the limits associated with current diagnostic technologies. In this study, an active vibration measurement technique is employed to investigate the presence and severity of meniscus tear in cadaver limbs. In a highly controlled ex vivo experimental design, a series of cadaver knees (n=6) were evaluated under an external vibration, and the frequency response of the joint was analyzed to differentiate the intact and affected samples. Four stages of knee integrity were considered: baseline, sham surgery, meniscus tear, and meniscectomy. Analyzing the frequency response of injured legs showed significant changes compared to the baseline and sham stages at selected frequency bandwidths. Furthermore, a qualitative analytical model of the knee was developed based on the Euler-Bernoulli beam theory representing the meniscus tear as a change in the local stiffness of the system. Similar trends in frequency response modulation were observed in the experimental results and analytical model. These findings serve as a foundation for further development of wearable devices for detection and grading of meniscus tear and for improving our understanding of the physiological effects of injuries on the vibration characteristics of the knee. Such systems can also aid in quantifying rehabilitation progress following reconstructive surgery and / or during physical therapy.


  • Open Access

    A Pilot Study to Assess the Reliability of Sensing Joint Acoustic Emissions of the Wrist

    by Daniel M. Hochman, Sevda Gharehbaghi, Daniel C. Whittingslow, Omer T. Inan

    Joint acoustic emission (JAE) sensing has recently proven to be a viable technique for non-invasive quantification indicating knee joint health. In this work, we adapt the acoustic emission sensing method to measure the JAEs of the wrist—another joint commonly affected by injury and degenerative disease. JAEs of seven healthy volunteers were recorded during wrist flexion-extension and rotation with sensitive uniaxial accelerometers placed at eight locations around the wrist. The acoustic data were bandpass filtered (150 Hz–20 kHz). The signal-to-noise ratio (SNR) was used to quantify the strength of the JAE signals in each recording. Then, nine audio features were extracted, and the intraclass correlation coefficient (ICC) (model 3,k), coefficients of variability (CVs), and Jensen–Shannon (JS) divergence were calculated to evaluate the interrater repeatability of the signals. We found that SNR ranged from 4.1 to 9.8 dB, intrasession and intersession ICC values ranged from 0.629 to 0.886, CVs ranged from 0.099 to 0.241, and JS divergence ranged from 0.18 to 0.20, demonstrating high JAE repeatability and signal strength at three locations. The volunteer sample size is not large enough to represent JAE analysis of a larger population, but this work will lay a foundation for future work in using wrist JAEs to aid in diagnosis and treatment tracking of musculoskeletal pathologies and injury in wearable systems.


  • Acoustic Emissions as a Non-invasive Biomarker of the Structural Health of the Knee

    by Daniel. C. Whittingslow, Hyeon-Ki Jeong, Venu G. Ganti, Nathan J. Kirkpatrick, Geza F. Kogler, Omer T. Inan

    The longitudinal assessment of joint health is a long-standing issue in the management of musculoskeletal injuries. The acoustic emissions (AEs) produced by joint articulation could serve as a biomarker for joint health assessment, but their use has been limited by a lack of mechanistic understanding of their creation. In this paper, we investigate that mechanism using an injury model in human lower-limb cadavers, and relate AEs to joint kinematics. Using our custom joint sound recording system, we recorded the AEs from nine cadaver legs in four stages: at baseline, after a sham surgery, after a meniscus tear, and post-meniscectomy. We compare the resulting AEs using their b-values. We then compare joint anatomy/kinematics to the AEs using the X-ray reconstruction of moving morphology (XROMM) technique. After the meniscus tear the number and amplitude of the AE peaks greatly increased from baseline and sham (b-value = 1.33 ± 0.15; p < 0.05). The XROMM analysis showed a close correlation between the minimal inter-joint distances (0.251 ± 0.082 cm during extension, 0.265 ± .003 during flexion, at 145°) and a large increase in the AEs. This work provides key insight into the nature of joint AEs, and details a novel technique and analysis for recording and interpreting these biosignals.


  • Robust Longitudinal Ankle Edema Assessment Using Wearable Bioimpedance Spectroscopy

    by Samer Mabrouk, Sinan Hersek, Hyeon Ki Jeong, Daniel Whittingslow, Venu G. Ganti, Paul Wolkoff, Omer T. Inan

    Objective: We present a robust methodology for tracking ankle edema longitudinally based on bioimpedance spectroscopy (BIS). Methods: We designed a miniaturized BIS measurement system and employed a novel calibration method that enables accurate, high-resolution measurements with substantially lower power consumption than conventional approaches. Using this state-of-the-art wearable BIS measurement system, we developed a differential measurement technique for robust assessment of ankle edema. This technique addresses many of the major challenges in longitudinal BIS-based edema assessment, including day-to-day variability in electrode placement, positional/postural variability, and intersubject variability. Results: We first evaluated the hardware in bench-top testing, and determined the error of the bioimpedance measurements to be 0.4 Ω for the real components and 0.54 Ω for the imaginary components with a resolution of 0.2 Ω. We then validated the hardware and differential measurement technique in: 1) an ex vivo, fresh-frozen, cadaveric limb model, and 2) a cohort of 11 human subjects for proof of concept (eight healthy controls and five subjects with recently acquired acute unilateral ankle injury). Conclusion: The hardware design, with novel calibration methodology, and differential measurement technique can potentially enable long-term quantification of ankle edema throughout the course of rehabilitation following acute ankle injuries. Significance: This could lead to better-informed decision making regarding readiness to return to activities and/or tailoring of rehabilitation activities to an individual's changing needs.