Shuo Deng

Shuo Deng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shuo Deng has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Strain-Dependent Dielectric and Optical Properties of Monolayer MoS2 with Phase-Sensitive Surface Plasmon Resonance (SPR) Method

    by Xianzhu Zou, Min Li, Haifei Lu, Xiaoyan Wen, Lijie Li, Shuo Deng, Zhiwen Ming

    Monolayer molybdenum disulfide (MoS2) holds great promise for strain-tunable optoelectronic devices. The strain-dependent dielectric function is a core parameter to characterize the tunability of optoelectronic properties. However, due to the extremely short light–matter interaction path length for atomically thin materials, measurements are challenging. In this work, we measured the dielectric function of strained monolayer MoS2 using the surface plasmon resonance (SPR) method with the simulated annealing particle swarm optimization (SAPSO) algorithm. When the applied strain ranged from −0.23% (compressive strain) to +0.20% (tensile strain), the dielectric function at seven characteristic wavelengths around the exciton absorption peaks was extracted. Our results demonstrate that both the real part (ε2r) and the imaginary part (ε2i) of the dielectric function evolved almost linearly with the applied strain from −0.23% to +0.20%. Based on these results, we further obtained the strain-induced variations in the refractive index (n) and the extinction coefficient (k). At exciton absorption peak B (600 nm), the strain-induced change rate for n reached a maximum of about −0.0141%−1. At the rising edge of the B exciton absorption (580 nm), the strain-induced change rate for k reached a maximum of about −0.3261%−1. This work presents a quantitative extraction of strain-dependent dielectric function of monolayer MoS2 over excitonic band-edge wavelengths using phase SPR–SAPSO fitting. The proposed method can be extended to the measurement of other atomically thin materials.


  • Open Access

    Dual-Resonance Plasmonic Nanocavity with Differential Thermo-Optic Response for Enhanced Fiber-Optic Thermal Flowmeters

    by Yekun Cao, Lei Sun, Min Li, Ming-Yu Li, Xiaoyan Wen, Shuo Deng, Sisi Liu, Hongyun Gao, Haifei Lu, Dengzun Yao

    Optic-fiber-based thermal flowmeters have the merits of compact size and high sensitivity, which typically require two light beams separately acting as a pump for heating the sensing unit and a probe for sensing temperature with the variation of external flow. Here, we propose a metallic nanostructure with multiple plasmonic resonance modes for the application of an optic-fiber-based thermal flowmeter. The optical properties of a nanostructure comprised of a double-width gold grating, a poly (methylmethacrylate) (PMMA) layer, and a gold film are numerically simulated in the spectral range of 600–1800 nm. The optical resonances of different modes are systematically investigated with the variation of the structural parameters. Interestingly, two optical resonance modes with distinct spectral shift under the same temperature variation, i.e., 21.34 pm/°C vs. 269.2 pm/°C, are obtained after the strategic optimization of the nanostructure. Finally, the sensitivity of the flowmeter with the proposed nanostructure is investigated by adopting the low-temperature sensitivity mode for optical pumping and the high-temperature sensitivity mode for temperature sensing, proving its significant potential as an optic-fiber-based thermal flowmeter.

  • Open Access

    A Direct Measurement of the C2H2 Concentration from the C2H2–Oil Mixed Solution Using the Photoacoustic Spectroscopy Method

    by Zikang Rong, Jian Ke, Haifei Lu, Xiaoyan Wen, Lijie Li, Zhiwen Ming, Shuo Deng, Min Li

    The photoacoustic (PA) method is commonly used in the measurement of trace gas concentration owing to its high accuracy and reliability. However, the conventional PA method is usually used in the gas-phase environment, which leads to a long measurement time and a large equipment volume for the degassing process. In this paper, we report a scheme to measure the acetylene (C2H2) concentration from the acetylene–dielectric oil (C2H2–Oil) mixed solution without the degassing process. The frequency and intensity distribution of the PA signal in the C2H2–Oil mixed liquid is investigated using the finite element method (FEM). Simulation results reveal that the incident light modulation frequency and the geometry size of the PA cell are two core factors to determine the PA signal. Furthermore, a PA sensor system is constructed to measure the concentration of C2H2 from the C2H2–Oil mixed solution. The measurement results demonstrate that the intensity of the PA signal in the C2H2–Oil mixed solution rises mostly linearly with the concentration of C2H2 from 0 to 100 mL/L. The Allan variance results from the continuous tests indicate that the measurement limit of the PA sensor system is about 0.2 mL/L. This work points to a novel method for the measurement of the C2H2 concentration from the C2H2–Oil mixed solution.


  • High-efficiency photoacoustic transducers based on plasmonic EGaIn liquid metal nanoparticles

    by Cheng Luo, Rui Zhou, Yihao Li, Min Li, Xiaoyan Wen, Ming-Yu Li, Shuo Deng, Sisi Liu, Hongyun Gao, Haifei Lu

    Metal nanoparticles hold promising applications in photoacoustic transducers due to their unique plasmonic properties. However, current transducers using conventional noble metal nanoparticles exhibit relatively low photoacoustic conversion efficiency, primarily due to insufficient optical absorption for effective thermal or acoustic energy conversion. This paper proposes the use of nanoparticles derived from the liquid metal gallium-indium eutectic alloy (EGaIn), which demonstrate significantly higher absorption at 1064 nm compared to gold or silver nanoparticles, thereby enhancing photoacoustic conversion efficiency. To stabilize the liquid metal nanoparticles (LMNPs) in a polydimethylsiloxane (PDMS) matrix, 3-mercaptopropyltriethoxysilane (MPTMS) is employed as a surfactant during sonication in a solvent. Furthermore, embedding EGaIn nanoparticles in a cluster form enhances absorption through gap-induced plasmonic effects. Through optimization, a photoacoustic conversion efficiency of 5.1 × 10−3 is achieved, which is 1–2 orders of magnitude higher than those of transducers using conventional metal materials. This study highlights the potential of liquid metal nanoparticles with plasmonic effects in advancing the development of novel photoacoustic composite materials.


  • Open Access

    Quantum Dot-Based Optical Fiber Sensor for Flow Velocity Sensing at Low Initial Temperatures

    by Lei Sun, Yekun Cao, Rui Zhou, Min Li, Xiaoyan Wen, Ming-Yu Li, Shuo Deng, Sisi Liu, Haifei Lu

    The accurate monitoring of flow velocity is crucial in applications such as blood microcirculation and microfluidic systems. However, the high sensitivity of current hot wire flowmeters is often achieved at the expense of increasing the initial temperature, which imposes significant limitations when measuring blood or other temperature sensitive fluids. In this study, a fiber sensor probe with a plano-concave cavity, fabricated from a PbS quantum dots (QDs)-doped photoresist, is proposed for the sensitive flow velocity detection of microfluidics. In the proposed hot wire-based micro-flowmeter, the excitation laser (980 nm) is efficiently absorbed and converted into thermal energy, while minimally affecting the high-quality interference of the cavity at the C-band. The experimental results show that only a 3 °C increase in temperature is required for flow velocity monitoring, with a sensitivity of 7.7 pm/(mm/s) achieved within a linear response range of 3.82 mm/s to 16.72 mm/s. Additionally, an intensity interrogation scheme is introduced for the hot wire-based fiber sensor probe. This low initial temperature requirement makes the proposed sensor suitable for microfluidics, demonstrating promising potential for use in microcirculation measurement and drug delivery systems.


  • Output power density enhancement of an intermittently contacted metal–semiconductor junction with a water interlayer

    by Xinru Fan, Shuo Zhang, Qihan Chen, Min Li, Haifei Lu, Shuo Deng, Qing Zhang

    The output power density of an intermittently contacted gold–silicon (Au–Si) junction can be increased by about 3 orders of magnitude after introduction of a water (H 2 O) interlayer between the Au and Si friction layers.

  • Open Access

    Sensitivity Enhancement of 2D Material-Based Surface Plasmon Resonance Sensor with an Al–Ni Bimetallic Structure

    by Miaosen Hu, Min Li, Ming-Yu Li, Xiaoyan Wen, Shuo Deng, Sisi Liu, Haifei Lu

    In this paper, a variety of 2D materials on the surface plasmon resonance sensor based on Al–Ni bimetallic layer are compared. Simulation results indicate that lateral position shift, which is calculated according to the real and imaginary parts of the refractive index of material, can be used as an effective parameter to optimize the sensitivity. By using the parameters for optimizing the SPR structures, the results show that the multiple layer models of Al(40 nm)–Ni(22 nm)–black phosphorus (BP)(1 L) and Al(40 nm)–Ni(22 nm)–blue phosphorus (BlueP)/WS2(1 L) exhibit average angular sensitivities of 507.0 °/RIU and 466 °/RIU in the refractive index range of 1.330–1.335, and maximum sensitivity of 542 °/RIU and 489 °/RIU at the refractive index of 1.333, respectively. We expect more applications can be explored based on the highly sensitive SPR sensor in different fields of optical sensing.


  • High-Performance Optical Fiber Fabry–Perot Sensor Based on a Sawtooth Spectrum and Its Application in Acoustic Sensing

    by Rui Zhou, Luo Wang, Min Li, Ming-Yu Li, Xiaoyan Wen, Shuo Deng, Sisi Liu, Haifei Lu

    Optical fiber sensor based on Fabry-Perot (F-P) resonance with saw-tooth spectral shape can break the mutual constraint of sensitivity and response range through simultaneously demodulating intensity variation of lasers working on the two asymmetric spectral lines. Here, theoretical solution and practical approach for obtaining the F-P resonance with saw-tooth spectrum have been proposed. The linear range and slope of the asymmetric spectrum are firstly calculated based on the proposed theoretical model which regulates the spectral shape variation. Then, the composite film on fiber end face has been solved to fulfill the model parameters required for saw-tooth spectrum through reversely utilizing equivalent interface approach, which has been theoretically and experimentally demonstrated by using a composite film of Platinum and Germanium (Pt/Ge) as the first reflective mirror and gold film as the second mirror. Finally, an optical fiber F-P sensor with saw-tooth spectral characteristics is prepared for underwater acoustic sensing application, which demonstrates an average of 10 dB improvement in dynamic range at the frequency range of 20-800 Hz.


  • Open Access

    High Performance 0D ZnO Quantum Dot/2D (PEA)2PbI4 Nanosheet Hybrid Photodetectors Fabricated via a Facile Antisolvent Method

    by Shijie Liu, Hao Li, Haifei Lu, Yanran Wang, Xiaoyan Wen, Shuo Deng, Ming-Yu Li, Sisi Liu, Cong Wang, Xiao Li

    Two-dimensional (2D) organic−inorganic perovskites have great potential for the fabrication of next-generation photodetectors owing to their outstanding optoelectronic features, but their utilization has encountered a bottleneck in anisotropic carrier transportation induced by the unfavorable continuity of the thin films. We propose a facile approach for the fabrication of 0D ZnO quantum dot (QD)/2D (PEA)2PbI4 nanosheet hybrid photodetectors under the atmospheric conditions associated with the ZnO QD chloroform antisolvent. Profiting from the antisolvent, the uniform morphology of the perovskite thin films is obtained owing to the significantly accelerated nucleation site formation and grain growth rates, and ZnO QDs homogeneously decorate the surface of (PEA)2PbI4 nanosheets, which spontaneously passivate the defects on perovskites and enhance the carrier separation by the well-matched band structure. By varying the ZnO QD concentration, the Ion/Ioff ratio of the photodetectors radically elevates from 78.3 to 1040, and a 12-fold increase in the normalized detectivity is simultaneously observed. In addition, the agglomeration of perovskite grains is governed by the annealing temperature, and the photodetector fabricated at a relatively low temperature of 120 °C exhibits excellent stability after a 50-cycle test in the air condition without any encapsulation.