CSChe-Chou Shen

Che-Chou Shen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Che-Chou Shen has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-contrast ultrafast ultrasound power doppler imaging using subarray adaptive temporal autocorrelation with phase compensation

    by Che-Chou Shen, Chih-Chung Huang, Han-Wen Hsu

    Compared to the conventional zero-lag autocorrelation (R(0)) estimation which directly accumulates the power of Doppler ensembles for ultrafast ultrasound power Doppler (PD) imaging, first-lag autocorrelation (R(1)) enhances the noise suppression in PD imaging by exploiting the temporal coherence among ensembles. The temporal multiply-and-sum (TMAS) algorithm can further reduce the noise level by multiplying the correlation pairs in R(1) estimation before summation. Nonetheless, TMAS estimation often suffers from noticeable signal loss due to blood flow decorrelation in the presence of temporal flow variation. To overcome this, we propose a method to integrate phase compensation with subarray adaptive TMAS (SA-TMAS) algorithm to restore the signal of blood flow in R(1) PD images. In phase compensation, the phase shift of blood flow signal among different plane-wave transmit angles is corrected to improve the angular coherence within each ensemble. Moreover, the subarray method helps to preserve the flow signal by using a shorter temporal window for R(1) estimation. Correlation between the complementary transmit subset is also used for adaptive weighting of the subarray PD image and for adaptive modulation of the temporal coherence to avoid excessive suppression of blood flow. The proposed SA-TMAS with phase compensation is validated using simulation and in vivo datasets. Results show that the proposed method achieves noise suppression comparable to the original full array TMAS while effectively preserving vascular signals due to reduced flow decorrelation. In the simulations, the phase compensation alone improves the contrast-to-noise ratio (CNR) of R(0) image by 2–8 dB depending on how dominant the axial flow is in the vessel. Using the R(0) image as the benchmark, the proposed R(1) SA-TMAS image additionally provides CNR improvement of 4 dB in the in vivo dataset while maintaining the corresponding generalized CNR and thus enables the high-contrast vascular PD images.

  • Open Access

    Ultrasound synthetic aperture imaging with SpecularNet for enhanced needle visualization

    by Che-Chou Shen, Liang-Chun Tung

    Ultrasound imaging has been routinely used for needle guidance due to its real-time capability and cost-efficiency. However, conventional ultrasound with fixed-angle transmission often suffers from reduced visualization of oblique needles when the specular echoes are reflected away from the receiving transducer. Synthetic transmit aperture (STA) beamforming with delay and standard deviation (DASD) relies on the variation of echo magnitude among various incident angles to construct the image. It can be further integrated with the specular information of the needle shaft predicted by convolutional neural networks (CNN) models to improve the image contrast in needle detection. The proposed SpecularNet estimates the orientation and the specular probability of the needle from pixel-wise STA channel data. The proposed specular STA-DASD was validated using experiments. Results indicated that, for needle orientations between 10° and 40°, the specular STA-DASD improved the needle-to-speckle ratio (NSR) by 11.0 dB and the needle-to-artifact ratio (NAR) by 18.9 dB compared to the conventional STA-DASD. Compared to standard specular beamforming, the inference to specular information can be efficiently performed in SpecularNet, while both the NSR and NAR of the corresponding specular STA-DASD also improve by another 25-30 dB. The efficacy of the proposed specular STA-DASD beamforming was demonstrated for enhancement of needle visualization. The specular information could be predicted using SpecularNet with high computational efficiency to guide the transmit/receive apodization and to suppress background noise and artifacts using image weighting.

  • Optimization of Ultrasound Phase-Encoded Multiplane Wave Tissue Harmonic Imaging

    by Che-Chou Shen, Ching-Che Chiu, You-Lin Chu

    Tissue harmonic imaging has superior spatial and contrast resolution compared to conventional linear imaging but suffers from low signal-to-noise ratio (SNR). While phase-encoded excitation can be used to improve the harmonic SNR, distortion of the harmonic signal may compromise the accuracy of bipolar code sequence, leading to axial artifacts in tissue harmonic imaging after decoding. In this study, phase-encoded tissue harmonic imaging with multiplane wave (MW) transmission is compared among coding matrices (i.e., Hadamard, S-sequence and orthogonal Golay) as well as different design of bit waveform. Both simulations and experiments are conducted to validate our analysis on the coding schemes and bit waveforms. Results demonstrate that Hadamard and Golay are affected by phase distortion of harmonic waveform due to their bipolar nature. However, Hadamard can avoid these axial artifacts by sacrificing the first plane wave (PW) angle in the angular compounding. In contrast, the unipolar S-sequence is not affected by phase distortion but suffers from the reduced SNR gain compared to Hadamard. Regarding the bit waveform, the rectangular waveform provides the higher SNR but induces severe spectral distortion of the transmit phase due to its discontinuities in the envelope. This distortion becomes prominent when combined with Golay, leading to severe axial artifacts and a noticeable reduction in image contrast. It is concluded that the Hadamard with rectangular waveform and selective compounding is the optimal configuration for phase-encoded MW tissue harmonic imaging due to its higher SNR than the S-sequence and higher image quality than the orthogonal Golay.

  • Open Access

    Improvement in Multi-Angle Plane Wave Image Quality Using Minimum Variance Beamforming with Adaptive Signal Coherence

    by Che-Chou Shen, Chun-Lin Huang

    For ultrasound multi-angle plane wave (PW) imaging, the coherent PW compounding (CPWC) method provides limited image quality because of its conventional delay-and-sum beamforming. The delay-multiply-and-sum (DMAS) method is a coherence-based algorithm that improves image quality by introducing signal coherence among either receiving channels or PW transmit angles into the image output. The degree of signal coherence in DMAS is conventionally a global value for the entire image and thus the image resolution and contrast in the target region improves at the cost of speckle quality in the background region. In this study, the adaptive DMAS (ADMAS) is proposed such that the degree of signal coherence relies on the local characteristics of the image region to maintain the background speckle quality and the corresponding contrast-to-noise ratio (CNR). Subsequently, the ADMAS algorithm is further combined with minimum variance (MV) beamforming to increase the image resolution. The optimal MV estimation is determined to be in the direction of the PW transmit angle (Tx) for multi-angle PW imaging. Our results show that, using the PICMUS dataset, TxMV-ADMAS beamforming significantly improves the image quality compared with CPWC. When the p value is globally fixed to 2 as in conventional DMAS, though the main-lobe width and the image contrast in the experiments improve from 0.57 mm and 27.0 dB in CPWC, respectively, to 0.24 mm and 38.0 dB, the corresponding CNR decreases from 12.8 to 11.3 due to the degraded speckle quality. With the proposed ADMAS algorithm, however, the adaptive p value in DMAS beamforming helps to restore the CNR value to the same level of CPWC while the improvement in image resolution and contrast remains evident.


  • Open Access

    Ultrasound Ultrafast Power Doppler Imaging with High Signal-to-Noise Ratio by Temporal Multiply-and-Sum (TMAS) Autocorrelation

    by Che-Chou Shen, Feng-Ting Guo

    Coherent plane wave compounding (CPWC) reconstructs transmit focusing by coherently summing several low-resolution plane-wave (PW) images from different transmit angles to improve its image resolution and quality. The high frame rate of CPWC imaging enables a much larger number of Doppler ensembles such that the Doppler estimation of blood flow becomes more reliable. Due to the unfocused PW transmission, however, one major limitation of the Doppler estimation in CPWC imaging is the relatively low signal-to-noise ratio (SNR). Conventionally, the Doppler power is estimated by a zero-lag autocorrelation which reduces the noise variance, but not the noise level. A higher-lag autocorrelation method such as the first-lag (R(1)) power Doppler image has been developed to take advantage of the signal coherence in the temporal direction for suppressing uncorrelated random noises. In this paper, we propose a novel Temporal Multiply-and-Sum (TMAS) power Doppler detection method to further improve the noise suppression of the higher-lag method by modulating the signal coherence among the temporal correlation pairs in the higher-lag autocorrelation with a tunable pt value. Unlike the adaptive beamforming methods which demand for either receive–channel–domain or transmit–domain processing to exploit the spatial coherence of the blood flow signal, the proposed TMAS power Doppler can share the routine beamforming architecture with CPWC imaging. The simulated results show that when it is compared to the original R(1) counterpart, the TMAS power Doppler image with the pt value of 2.5 significantly improves the SNR by 8 dB for the cross-view flow velocity within the Nyquist rate. The TMAS power Doppler, however, suffers from the signal decorrelation of the blood flow, and thus, it relies on not only the pt value and the flow velocity, but also the flow direction relative to the geometry of acoustic beam. The experimental results in the flow phantom and in vivo dataset also agree with the simulations.


  • Open Access

    Effect of Dialysis Modalities on All-Cause Mortality and Cardiovascular Mortality in End-Stage Kidney Disease: A Taiwan Renal Registry Data System (TWRDS) 2005–2012 Study

    by Po-Cheng Su, Cai-Mei Zheng, Chien-Chou Chen, Li-Yun Chiu, Hao-Yun Chang, Meng-Hsu Tsai, Chia-Te Liao, Chih-Chin Kao, Yung-Ho Hsu, Che-Chou Shen, et al.

    Introduction: End-stage kidney disease (ESKD) patients who need renal replacement therapy need to face a dialysis modality decision: the choice between hemodialysis (HD) and peritoneal dialysis (PD). Although the global differences in HD/PD penetration are affected by health-care policies, these two modalities may exert different effects on survival in patients with ESKD. Although Taiwan did not implicate PD as first policy, we still need to compare patients’ outcomes using two modalities in a nation-wise database to determine future patients’ care and health policies. Methods: We used the nationwide Taiwan Renal Registry Data System (TWRDS) database from 2005 to 2012 and included 52,900 patients (48,371 on HD and 4529 on PD) to determine all-cause and cardiovascular mortality among ESKD patients. Results: Age-matched survival probability from all-cause mortality was significantly lower in patients on PD than in those on HD (p < 0.05). The adjusted hazard ratios of 3-year and 5-year all-cause and cardiovascular mortality were significantly higher in PD compared with HD. The presence of comorbid conditions including myocardial infarction, coronary artery disease (CAD), diabetes mellitus (DM), hypoalbuminemia, hyperferritinemia and hypophosphatemia was related with significantly higher all-cause and CV mortality in PD patients. No significant difference was noted among younger patients <45 years of age regardless of DM and/or comorbid conditions. Conclusion: Although PD did not have the survival advantage compared to HD in all dialysis populations, PD was related with superior survival in younger non-DM patients, regardless of the presence of comorbidities. Similarly, for younger ESKD patients without the risk of CV disease, both PD and HD would be suitable dialysis modalities.


  • Golay-Encoded Ultrasound Monitoring of Simultaneous High-Intensity Focused Ultrasound Treatment: A Phantom Study

    by Che-Chou Shen, Ri-Cheng Lin, Nien-Hung Wu

    Ultrasound (US) imaging has high potential in monitoring high-intensity focused US (HIFU) treatment due to its superior temporal resolution. However, US monitoring is often hindered by strong HIFU interference, which overwhelms the echoes received by the imaging array. In this study, a method of Golay-encoded US monitoring is proposed to visualize the imaged object for simultaneous HIFU treatment. It effectively removes HIFU interference patterns in real-time B-mode imaging and improves the metrics of image quality, such as peak signal-to-noise ratio (PSNR), structural similarity (SSIM), and contrast ratio (CR). Compared to the pulse-inversion sequence, the ${N}$ -bit Golay sequence can boost the echo magnitude of US monitoring by another ${N}$ times and, thus, exhibits higher robustness. Simulations show that a sinusoidal HIFU waveform can be fully eliminated using Golay decoding when the bit duration of the ${N}$ -bit Golay sequence ( ${N}$ is the power of 4) coincides with either odd (Case I) or even (Case II) integer multiples of the HIFU quarter period. Experimental results also show that the Golay decoding with Case II can increase the PSNR of US monitoring images by more than 30 dB for both pulse- and continuous-wave HIFU transmissions. The SSIM index also effectively improves to about unity, indicating that the B-mode image with HIFU transmission is visually indistinguishable from that acquired without HIFU transmission. Though Case I is inferior to Case II in the elimination of even-order HIFU harmonic, they together enable a more flexible selection of imaging frequencies to meet the required image resolution and penetration for Golay-encoded US monitoring.