JBJens Buck

Jens Buck

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jens Buck has a total of 123 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Photon-shot-noise-limited transient absorption soft X-ray spectroscopy at the European XFEL

    by Loïc Le Guyader, Andrea Eschenlohr, Martin Beye, William Schlotter, Florian Döring, Cammille Carinan, David Hickin, Naman Agarwal, Christine Boeglin, Uwe Bovensiepen, et al.

    Femtosecond transient soft X-ray absorption spectroscopy (XAS) is a very promising technique that can be employed at X-ray free-electron lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here, a dedicated setup for soft X-rays available at the Spectroscopy and Coherent Scattering (SCS) instrument at the European X-ray Free-Electron Laser (European XFEL) is presented. It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and unexcited sample, as well as to monitor the incoming intensity. Since these three intensity signals are detected shot by shot and simultaneously, this setup allows normalized shot-by-shot analysis of the transmission. For photon detection, an imaging detector capable of recording up to 800 images at 4.5 MHz frame rate during the FEL burst is employed, and allows a photon-shot-noise-limited sensitivity to be approached. The setup and its capabilities are reviewed as well as the online and offline analysis tools provided to users.


  • Open Access

    High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

    by Alberto De Fanis, Markus Ilchen, Alexander Achner, Thomas M. Baumann, Rebecca Boll, Jens Buck, Cyril Danilevsky, Sergey Esenov, Benjamin Erk, Patrik Grychtol, et al.

    A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s −13p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ∼0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.


  • Open Access

    Element-Specific Magnetization Dynamics of Complex Magnetic Systems Probed by Ultrafast Magneto-Optical Spectroscopy

    by Clemens von Korff Schmising, Felix Willems, Sangeeta Sharma, Kelvin Yao, Martin Borchert, Martin Hennecke, Daniel Schick, Ilie Radu, Christian Strüber, Dieter W. Engel, et al.

    The vision to manipulate and control magnetism with light is driven on the one hand by fundamental questions of direct and indirect photon-spin interactions, and on the other hand by the necessity to cope with ever growing data volumes, requiring radically new approaches on how to write, read and process information. Here, we present two complementary experimental geometries to access the element-specific magnetization dynamics of complex magnetic systems via ultrafast magneto-optical spectroscopy in the extreme ultraviolet spectral range. First, we employ linearly polarized radiation of a free electron laser facility to demonstrate decoupled dynamics of the two sublattices of an FeGd alloy, a prerequisite for all-optical magnetization switching. Second, we use circularly polarized radiation generated in a laboratory-based high harmonic generation setup to show optical inter-site spin transfer in a CoPt alloy, a mechanism which only very recently has been predicted to mediate ultrafast metamagnetic phase transitions.


  • Open Access

    A zone-plate-based two-color spectrometer for indirect X-ray absorption spectroscopy

    by Florian Döring, Marcel Risch, Benedikt Rösner, Martin Beye, Philipp Busse, Katharina Kubiček, Leif Glaser, Piter S. Miedema, Jakob Soltau, Dirk Raiser, et al.

    X-ray absorption spectroscopy (XAS) is a powerful element-specific technique that allows the study of structural and chemical properties of matter. Often an indirect method is used to access the X-ray absorption (XA). This work demonstrates a new XAS implementation that is based on off-axis transmission Fresnel zone plates to obtain the XA spectrum of La0.6Sr0.4MnO3 by analysis of three emission lines simultaneously at the detector, namely the O 2p–1s, Mn 3s–2p and Mn 3d–2p transitions. This scheme allows the simultaneous measurement of an integrated total fluorescence yield and the partial fluorescence yields (PFY) of the Mn 3s–2p and Mn 3d–2p transitions when scanning the Mn L-edge. In addition to this, the reduction in O fluorescence provides another measure for absorption often referred to as the inverse partial fluorescence yield (IPFY). Among these different methods to measure XA, the Mn 3s PFY and IPFY deviate the least from the true XA spectra due to the negligible influence of selection rules on the decay channel. Other advantages of this new scheme are the potential to strongly increase the efficiency and throughput compared with similar measurements using conventional gratings and to increase the signal-to-noise of the XA spectra as compared with a photodiode. The ability to record undistorted bulk XA spectra at high flux is crucial for future in situ spectroscopy experiments on complex materials.


  • Progress report on the XUV online diagnostic unit for the highly accurate determination of SR properties

    by Jens Buck, Kai Bagschik, Leif Glaser, Frank Scholz, Jörn Seltmann, Jens Viefhaus

    Recent results from simultaneous long-term stability measurements of the beam position and photon energy of the synchrotron beam at the soft X-ray beamline P04 at PETRA III (DESY, Hamburg) are presented. The data was obtained by operating the built-in, non-invasive diagnostic unit directly upstream the beamline focus in parallel with a user experiment. We demonstrate that a sophisticated data evaluation based on principal component analysis results a high positional accuracy better than a few micron and a stable photon energy measurement with an uncertainty in the low ppm regime. Even subtle effects caused by abnormalities in the electron storage ring operation (e.g. short interruptions of the electron injection) are revealed hereby. Utilizing online diagnostic data for feedback controls will enable unprecedented stability of beamline operation at synchrotrons and FEL sources in the future.